Loading...
HomeMy WebLinkAboutPolyglas - PSLFlorida Building Code Online Business Professional • i gulation ek ; SCIS Home 1�g In I User Re istration ' N 9 I of Topics i Submit Surcharge Stats 9 Facts Publications !, Conta t Us BCIS Site Map j L r,ks , Search bProduct 4411f� Approval a)r USER: Public Use - Product App.avy_,,, 1 1" '1 > Product or F�plicati�n Search > Ilcation , > 8p_p�� Application Detail FL # -• ". .- FL5259-R33 Application Type Revisior. Code Version 2020 Application Status Approved Comments Archived P-oduct Manufacturer POLYGLASS USA Address/?hone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1330 Ext 242 malpert@polyglass.com Authorized Signature Maury Alpert malpert@polyglass. com Technical Representative TECH .REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (866)802-8017 L�spolyglasstechnical @polyglass,com Quality Assurance Representative QA REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (888) 410-1375 ::spolyglasstechnical@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LL C Quality Assurance Contract Expiration Date 12/23/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL5259 R33 COI 2021 07 COI NIEhtI�N %qf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6163 2015 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 20i5 https:liftoridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDcvbSgAaZp3Crk2vS%2feg01ipIoQ53LIfLDSdir7nKfKN%2bQ%3d%3d 1/2 10/25/21, 2:33 PM Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Summary of Products Florida Building Code Online FM 4474 FRSA/TRI, Sixth Edition. TAS 103 UL 1897 Method 1 Option D 04/07/2021 04/12/2021 04/14/2021 06/08/2021 10/15/2021 2011 2018 2020 2015 FL # i Model, Number or Name Description 5259.1 Polyglass Roof Underlayments i ;(HVHZ) Polyglass roof underlayments for use in FBC HVHZ jurisdictions. Limits of use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER Section 5 for Limits of Use. Installation Instructions FL5259 R33 II 2021 04 07 FINAL ER PLYG UNDERLAYM=NTS FL5259 133 (HVHZ).p f Verified By: Robe t Memi.ner. PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL5259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS F-5259- R33 (HVH _pdf Created by Independent Third Party: Yes 5259,2 Polyglass Roof Underlayments (ron-HVHZ) Polyglass roof underlayments, for use in FBC non-HVHZ jurisdictions. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-622.5 Other: 1.) The design pressure in this application relates to one particular underlayment system for use in the roof systems. Refer to ER Section 5.8.3 for other systems and associated maximum design pressures. 2.) Refer to ER Section 5 for other limits of ::se. Installation Instructions FL5259 R33 II 202! 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259 R33 (NON-HVHZ;pddf Verified By: Robert Nieminen PE-59166 Created by independent Third Party: Yes Evaluation Reports FL5259 R33 AE 2021 04 07 FINAL ER PLYG UNDERI AYMENTS P 5259- R33 (NON-HVHZI,pdf Created by Independent Third Party: Yes Zack tvext Contact Us :: Z621 $lair stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. 99J2yri9ht 2007.2013 State of Florida :; Privacy Statement :: ACCGsIbiIILV $$ atcment :: Refund statement Under Florida law, emai! addresses are public records. If you do not want your e-mail address releasee in response to a public -records request, do not send electronic mail to this entity. ir•read, contact the office by phone or by traditional mail. I` you have any questions, please contact 850.487.1395. 'Pursuant to Section 455,275(1), Florida statutes, en ive October 1, 2012, licensees licensed under Chapter 4S5, ES, must provide the Department with an email address If they have one. The emaHs pro,ded may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personat address, please Provide the Department with an email address which can be made available to the public. 7b determine if you are a iicensee untler Chapter 455, Rs., please click here . Product Approval Accepts: x ®L=1 Credit Card Safe https:/ifloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQMDgvbSgAaZp3Crk2vS%2fegOliploQ53LIfLDSdir7nKfKN%2bQ%3d%3d 2/2 TRINITY ERD EVALUATION REPORT Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 98408 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report P12060.02.09-115 FL5259-R10 Date of Issuance: 02/24/2009 Revision 5: 06/25/2010 SCOPE: This Evaluation Report is issued under Rule 9B-72 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2007 Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized E DF = by Robert Nieminen, P.E. on 06/25/2010 This does not serve as an electronically signed document. Signed, sealed hardco ies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code (non-HVHZ) through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4, 1507.2.9.2, 1507.3.3, 1507.5.3, 1507.6.3 Physical Properties ASTM D1970 2001 1507.2.3, 1507.3.3, 1507.5.3, 1507.7.3, 1507.8.3, 1507.9.3, 1507.9.4 Physical Properties ASTM D226 1997 1507.11.2 Physical Properties ASTM D6164 2000 1507.11.2 Physical Properties ASTM D6222 2002 1504.6 Accelerated Aging ASTM G154 2000 1504.6 Accelerated Aging ASTM G155 2004 1504.3.1 Wind Uplift FM 4470 1992 3. REFERENCES: Entity Examination Reference Date PRI (TST 5878) Physical Properties PRIO1111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties JX20H7A 04/01/2008 MTI (TST 2508) Physical Properties RX14E8A 01/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD (TST 6049) Physical Properties P33360.06.10 06/25/2010 ICC-ES (EVL 2396) IBC Compliance ESR-1697 01/01/2005 ICC-ES (EVL 2396) IBC Compliance ESR-1160 03/01/2005 Miami -Dade (CER 1592) HVHZ Compliance NOA Current Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 UL (QUA1743) Quality Control File No. R14571, Vol 1 Exp. 11/30/2012 Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R5 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 2 of 9 TRINITY ERD 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlayments: 4.1.1 ELASTOBASE is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 ELASTOBASE P is a polyester -reinforced, SBS modified bitumen base sheet. 4.2 Self -Adhering Underlayments: 4.2.1 POLYSTICK MTS is a rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface. �7 4.2.2 POLYSTICK IR-Xe is a rubberized asphalt waterproofing membrane, glass fiber reinforced, with a sand surface. 4.2.3 POLYSTICK TU is a rubberized asphalt waterproofing membrane, glass fiber reinforced, with a granular surface. 4.2.4 POLYSTICK TU Plus is a rubberized asphalt waterproofing membrane, glass fiber reinforced, with a high strength polyester fabric surface. 4.2.5 POLYSTICK TU P is a rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface. 4.2.6 POLYFLEX SAP, POLYFLEX SAP FR, MULE -HIDE SA-APP CAP SHEET AND MULE -HIDE SA-APP CAP SHEET (FR) are a polyester reinforced, APP modified bitumen cap sheets. 4.2.7 DUAL PROTM is a dual -layer rubberized asphalt waterproofing membranes, fiberglass reinforced, with a high strength polyester fabric surface. 4.2.8 TILE PROTM is a dual -layer rubberized asphalt waterproofing membranes, fiberglass reinforced, with a high strength polyester fabric surface. 4.3 Mechanically Fastened and/or Bonded Underlayments: 4.3.1 ELASTOFLEX S6G AND ELASTOFLEX S6G FR are polyester reinforced, SBS modified bitumen cap sheets. 4.3.2 POLYFLEx G AND POLYFLEx G FR are polyester reinforced, APP modified bitumen cap sheets. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop the underlayments are as follows: Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R5 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 3 of 9 TRINITY ERD Table 1: Roof Cover Options Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal Wood Shakes & Shingles Slate Elastobase Yes Yes No Yes Yes Yes Elastobase P Yes Yes No Yes Yes Yes Polystick MTS Yes Yes (Batten only) No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU Yes Yes Yes No Yes Yes Polystick TU P Yes Yes Yes No Yes Yes Polystick TU Plus Yes Yes Yes Yes Yes Yes Dual Pro Yes Yes No Yes Yes Yes Tile Pro Yes Yes No Yes Yes Yes Elastoflex S6G or S6G FR Yes Yes Yes No Yes Yes Polyflex G or G FR Yes Yes Yes No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes No Yes Yes Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Yes Yes Yes No Yes Yes 5.4.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ➢ Polyfoam PolyPro AH160: Polystick TU, Polystick TU P, Polystick TU Plus, Elastoflex S6G, Elastoflex S6G FR, Polyflex G, Polyflex G FR, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR). ➢ Dow TileBond: Polystick TU P or Polyflex SAP 5.4.1.1 The maximum design pressure for direct -bond Polystick self -adhering applications to plywood or primed plywood is -135 psf. This is pertinent for foam -on tile systems only, where the bonded underlayment forms part of the load -path. 5.4.2 For nail -on tile systems over Polystick MTS, battens are required for both loading / staging of the tile and tile installation; direct -to -deck nail -on tile applications are not permissible with Polystick MTS. 5.4.3 For mechanically attached metal and nail -on tile, an underlayment system consisting of Polystick MTS followed by Polystick MTS, TU, TU P or TU Plus or Polystick SAP is permissible. 5.5 Allowable substrates are noted below: 5.5.1 Direct -Bond to Deck: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ASTM D41 primed structural concrete; OSB; Southern Yellow Pine; New untreated plywood; existing plywood primed as needed with ASTM D41 primer; or Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). ➢ Dual Pro or Tile Pro self -adhered to: New untreated plywood; or existing plywood primed as needed with ASTM D41 primer. ➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D41 primed structural concrete. ➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R5 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 4 of 9 TRINITY ERD 5.5.1.1 The maximum design pressure for direct -bond Polystick self -adhering applications to plywood or primed plywood is -135 psf. This is pertinent for foam -on tile systems only, where the bonded underlayment forms part of the load -path. For other substrates, consult Polyglass USA, Inc. 5.5.2 Bond -to -Insulation: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or SECUROCK Gypsum -Fiber Roof Board. ➢ Elastoflex S6G or S6G FR in hot asphalt to: DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. ➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4470, Appendix K or TAS 114, Appendix J. 5.5.3 Bond to Mechanically Attached Base Layer: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Polyflex G or G FR torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. 5.6 Exposure Limitations: 5.6.1 Elastobase, Elastobase P, Dual Pro or Tile Pro shall not be left exposed for longer than 30- days after installation. 5.6.2 Polystick IR-Xe shall not be left exposed for longer than 90-days after installation. 5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be left exposed for longer than 180-days after installation. 5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. 5.6.5 Elastoflex S6G or S6G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 180 days. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-115 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 5 of 9 TRINITY ERD 5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following: Table 2: Tile System Options for Roof Underlayments per FRSA/TRI 07320/8-OS System Underlay Option Section Reference Product(s) 1 3.02A Modified Cap Sheet Elastoflex S6G or S6G FR; Polyflex G or G FR 2 3.02B No. 30 / Modified Cap Elastobase; Elastobase P / Elastoflex S6G or S6G FR or Sheet Polyflex G or G FR System One: Mechanically 3 3.02C No. 30 / Modified Cap Sheet Elastobase; Elastobase P /Elastoflex 56G or 56G FR Fastened Tile, 4 3.02D No. 30 Elastobase; Elastobase P Unsealed or Sealed Self -Adhered Polystick MTS (batten only); TU; TU P; TU Plus; Polyflex Underlayment 5 3.02E Underlayment SAP or SAP FR; Mule -Hide SA-APP Cap Sheet or SA-APP System Cap Sheet (FR); Dual Pro; Tile Pro Elastobase; Elastobase P; Mule -Hide Nail Base / Polystick 6 3.02F No. 30 / Self -Adhered MTS (batten only); TU; TU P; TU Plus; Polyflex SAP or Underlayment SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Dual Pro; Tile Pro 1 3.02A Modified Cap Sheet Elastoflex S6G or S6G FR; Polyflex G or G FR 2 3.02B No. 30 / Modified Cap Elastobase; Elastobase P / Elastoflex S6G or S6G FR or Sheet Polyflex G or G FR System Two: Mechanically 3 3.02C No. 30 / Modified Cap Sheet Elastobase; Elastobase P / Elastoflex S6G or S6G FR Fastened Tile, Sealed Self -Adhered Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Underlayment 4 3.02D Underlayment Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); System Dual Pro; Tile Pro Elastobase; Elastobase P; Mule -Hide Nail Base / Polystick 5 3.02E No. 30 / Self -Adhered TU; TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA- Underlayment APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro; Tile Pro 1 3.02A Modified Cap Sheet Elastoflex S6G or S6G FR; Polyflex G or G FR System Four "A": 2 3.02B No. 30 / Modified Cap Elastobase; Elastobase P / Elastoflex S6G or S6G FR or Adhesive -Set Tile, Sheet Polyflex G or G FR Unsealed or Sealed 4 3.02D Self -Adhered Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Underlayment Underlayment Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) System No. 30 / Self -Adhered Elastobase; Elastobase P; Mule -Hide Nail Base / Polystick 5 3.02E Underlayment TU; TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA- APP Cap Sheet or SA-APP Cap Sheet (FR) 1 3.02A No. 30 / Modified Cap Elastobase; Elastobase P / Elastoflex S6G or S6G FR or System Four "B": Sheet Polyflex G or G FR Adhesive -Set Tile, 3 3.02C Self -Adhered Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Sealed Underlayment Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Underlayment System No. 30 / Self -Adhered Elastobase; Elastobase P; Mule -Hide Nail Base / Polystick 4 3.02D Underlayment TU; TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA- APP Cap Sheet or SA-APP Cap Sheet (FR) 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R5 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 6 of 9 TRINITY ERD 6.3 Elastobase, Elastobase P or Mule -Hide Nail Base: 6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 For use in non -tile applications: 6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings 6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex S6G or S6G FR in hot asphalt or Polyflex G or G FR, torch applied. 6.3.3 For use in tile applications, reference is made to Polyglass published installation instructions in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.4 Polystick MTS, IR-Xe, TU, TU P or TU Plus, Polyflex SAP or SAP FR, Mule -Hide SA- APP Can Sheet or SA-APP Cat) Sheet (FR), Dual Pro or Tile Pro: 6.4.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 For non -tile applications: 6.4.2.1 All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam as per Polyglass / Mule -Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back -nailed 6.4.2.2 All seal lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). View of Ovelap Seam of Dual Pro and Tile Pro Exterior Research and Design, LLC. Evaluation Report P12060.02.09-115 Certificate of Authorization #9503 FL5259-RIO Revision 5: 06/25/2010 Page 7 of 9 TRINITY ERD 6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. 6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details 6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. 6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 For tile applications (not allowed for Polystick IR-Xe): 6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for both loading / staging of the tile and tile installation; direct -to -deck nail -on tile applications are not permissible with Polystick MTS. 6.5 Elastoflex S6G or S6G FR: 6.5.1 Elastoflex S6G or S6G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications, reference is made FRSA/TRI 07320/8- 05 Installation Manual, Fourth Edition, and Table 2 herein. 6.5.2 Elastoflex S6G or S6G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 Polyflex G or G FR: 6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications, reference is made FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.6.2 Polyflex G or G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R5 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 8 of 9 TRINITY ERD 6.7 Tile Staging: 6.7.1 A maximum of 6 tiles per stack are allowed when loading tile directly onto the underlayments. Refer to the Polyglass Tile Loading Guidelines. l I Fbof Deck prepared with POLYSnCKTU Plus 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI 07320/8- 05 must be used on all roof slopes of 7:12 or greater. For roof slopes in excess of 6�/4:12, precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 6.7.3 For nail -on tile systems over Polystick MTS, battens are required for both loading / staging of the tile and tile installation; direct -to -deck nail -on tile applications are not permissible with Polystick MTS. 6.7.4 The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9B-72 QA requirements 10. QUALITY ASSURANCE ENTITY: Underwriters Laboratories - QUA1743 (847) 664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R5 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 9 of 9