HomeMy WebLinkAboutP0.1 REV2 PLUMBING FIXTURE SCHEDULE I PLUMBING NOTES PLUMBING SHEET INDEX Project: HANDICAP/DRINKING FOUNTAIN, ELKAY BI-LEVEL WALL MOUNTED 'I 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY FOR THE SHEET# DESCRIPTION HDF/DF BARRIER FREE MODEL # EZSTL8C.7.8 GPH, WADE 440-AM11-M36 I INSTALLATION OF A COMPLETE SCOPE OF WORK. ALL WORKMANSHIP AND MATERIALS SHALL BE IN CARRIER AS REQUIRED. 115V, 4.5 A, MUST MEET A.D.A. CODE. I STRICT ACCORDANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION (2020) - PLUMBING, P0.1 PLUMBING NOTES, LEGENDS, AND DETAILS POOL DF/HDF I APPLICABLE LOCAL CODES, RULES, AND ORDINANCES. GENERAL NOTES: �, DRAIN I P2.1 PLUMBING PLAN (1) - FIXTURES SHALL BE AS SHOWN OR EQUAL. 2. PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL (2) - ALL FIXTURES SHALL COMPLY WITH TABLE 604.4 OF FBC 2020 S� EXISTING CONDITIONS. (3) - ALL FIXTURE TRIM PACKAGES INCLUDING BUT NOT LIMITED TO TRAP, ANGLE STOP, FLUSH VALVE, 3. ALL MATERIALS SHALL BE NEW AND OF GOOD QUALITY. SUPPLY TUBES, AND CLEANOUT COVER PLATES SHALL BE OF THE SAME FINISH AS THE ABOVE RENOVATION SPECIFIED FAUCET AND PER ARCHITECTURAL FINISH SCHEDULE. (4) - ALL FIXTURES SHALL BE ROUGHED IN PER MANUFACTURER CUT SHEET TO MAINTAIN UNIFORMITY. 4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY-OPERATIONAL. ALL EXCAVATION PLUMBING LEGEND FOR AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS ' CONTRACT. 6" POOL DRAIN LINE TO STORM, 5. REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR FOR PROTECTION CO CLEAN OUT �� SANITARY SEWER PIPING EYE I AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. WASH I COORDINATE FINAL CONTENDER TERMINATION POINT 6. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTS. S.O.V. SHUT-OFF VALVE - - - VENT PIPING WITH CIVIL/SITEPLAN. PLUMBING CONTRACTOR SHALL OBTAIN PERMIT AND APPROVED SUBMITTALS PRIOR TO BEGINNING WORK OR ORDERING EQUIPMENT. PLUMBING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS COTC CLEAN OUT TO GRADE - DOMESTIC COLD WATER PIPING BOATS OF HIS WORK BY REGULATORY AUTHORITIES. FS FLOOR SINK -- HOT WATER PIPING (110') 2" EYE WASH DRAIN LINE TO STORM, 7. CONTRACTOR SHALL SUBMIT TO ARCHITECT/ENGINEER, FOR REVIEW & APPROVAL, FIVE (5) SETS OF CW DOMESTIC COLD WATER --- HOT WATER PIPING (140') COORDINATE FINAL TERMINATION MANUFACTURER'S CUT SHEETS FOR EACH FIXTURE, PIPING/FITTING MATERIAL AND EQUIPMENT ITEM POINT WITH CIVIL/SITEPLAN. WITH ASSOCIATED CONTROLS, THAT ARE INCLUDED IN THE CONTRACT. HW DOMESTIC HOT WATER --- HOT WATER RECIRCULATING PIPING 8. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING, HWR DOMESTIC HOT WATER RECIRCULATING CDC CONDENSATE PIPING 5701 ENVIRONMENTAL DRIVE EQUIPMENT, ETC. � ST. LUCIE COUNTY, FLORIDA 9. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE HB HOSE BIBB 5--CA COMPRESSED AIR PIPING PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ARCHITECT/ENGINEER PRIOR TO VTR VENT THRU ROOF BEGINNING CONSTRUCTION. �T&P� TEMPERATURE AND PRESSURE RELIEF SANITARY ISOMETRIC N.T.S. 10. VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERT ELEVATIONS OF ALL EXISTING UTILITIES GATE VALVE SD---- STORM DRAIN PIPING QPRIOR TO BEGINNING OF CONSTRUCTION. ADVISE ARCHITECT/ENGINEER OF ANY DISCREPANCIES. GLOBE VALVE G GAS PIPING 11. WATER DISTRIBUTION PIPING ABOVE AND BELOW GROUND SHALL BE TYPE "L" COPPER. ALTERNATE N CHECK VALVE S--(�s PIPE RISE UP PIPING & FITTING MATERIALS MAY BE USED IN ACCORDANCE WITH FLORIDA BUILDING CODE 7TH CODE REFERENCES UPDATED EDITION (2020) - PLUMBING, TABLES 605.3, 605.4 & 605.5, WHEN APPROVED BY ENGINEER OF GAS SOLENOID VALVE PIPE DOWN OR DROP TO FBC 7TH ED. 2020 RECORD AND LOCAL AUTHORITY HAVING JURISDICTION. PROVIDE ALTERNATE FOR CPVC PIPING & FITTINGS EQUAL TO LUBRIZOL CORZAN OR FLOW-GUARD GOLD. PROVIDE ALTERNATE FOR PEX TYPE i GAS COCK CAPPED END OF PIPE 'A' PIPING & FITTINGS EQUAL TO UPONOR. ALTERNATES ARE PERTINENT FOR WATER SERVICES # 1-1/2" DOMESTIC WATER KNOWN OR DETERMINED TO HAVE ACIDIC CHARACTERISTICS OR OTHER PARTICULAR CIRCUMSTANCES 4 WATER HAMMER ARRESTER (PDI No.) POINT OF CONNECTION LINE TO EXISTING SYSTEM, AS DEEMED APPROPRIATE BY DIRECTIVE FROM THE OWNER. CONTRACTOR SHALL PERFORM A WATER T PROVIDE FALL FLOW TEST TO DETERMINE WATER CHEMISTRY PRIOR TO ANY WORK OR PIPING INSTALLATION AND SHALL ® FLOOR DRAIN P-TRAP VALVES, FIELD VERIFY SUBMIT TEST RESULTS TO THE ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL. DISINFECTION OF FD EXACT COORDINATION / POTABLE WATER SYSTEM SHALL COMPLY WITH FLORIDA BUILDING CODE 7TH EDITION (2020) - POINT PRIOR TO ROUGH-IN. "I( I PLUMBING, SECTION 610. ALL WATER PIPING & FITTINGS SHALL BE OF DOMESTIC MANUFACTURE; SPECIFICALLY IN THE UNITED STATES OF AMERICA. Issues: I HB � 12. SOIL, WASTE, VENT, AND RAINWATER (DWV) PIPING & FITTINGS SHALL BE CAST IRON OR PVC, WHERE No,: Date: Description: CODE ALLOWS. PVC MAY NOT BE USED THRU RATED ASSEMBLIES OR IN PLENUMS. PVC PIPING EYE SHALL BE SOLID-CORE ONLY; FOAM-CORE PIPING SHALL NOT BE ACCEPTED. CAST IRON PIPING & A. PROVIDE TEST TEE WASH I FITTINGS SHALL BEAR THE CISPI-301 MARK. ALL DWV PIPING & FITTINGS SHALL BE OF DOMESTIC WITH SCREWED COUNTER- I I �I MANUFACTURE; SPECIFICALLY IN THE UNITED STATES OF AMERICA. I I COLUMN OR PARTITION „ SUNK ABS PLASTIC PLUG: I I AS SHOWN ON FLOOR PLAN 2 DOMESTIC WATER LINE TAPERED-THREAD WITH i I CLEANOUT FACE SHALL S\ TO EXISTING SYSTEM, 13. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE ANGLE STOPS AND APPROPRIATELY I „ MARKED ACCESS PANELS WHERE REQUIRED). COORDINATE LOCATIONS WITH GENERAL CONTRACTOR TFE JOINT COMPOUND. I I BE WITHIN 4 OF WALL PROVIDE FALL FLOW ( ) _� (A VALVES, FIELD VERIFY PRIOR TO INSTALLATION. WHERE CLEANOUT TEE _ PIPE EXTENSION VIIDEREQUIRED. EXACT COORDINATION POINT IS CONCEALED IN' A I I PRIOR TO ROUGH-IN. 14. PROVIDE APPROVED WATER HAMMER ARRESTORS FOR ALL (GROUP) PLUMBING FIXTURES, SIZED & CHASE OR PARTITION, LOCATED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS & PDI-WH2O1. I PROVIDE A ROUND 18 EYE 15. PROVIDE DIELECTRIC COUPLINGS OR FLANGES BETWEEN ALL DISSIMILAR METALS IN PIPING AND GAUGE STAINLESS STEEL WASH I COVER WITH BEVELED �I EQUIPMENT CONNECTIONS. I DF/HDF EDGES AND FLATHEAD I J 16. ISOLATE COPPER PIPING FROM METALLIC HANGERS OR SUPPORTS WITH ISOLATOR PADS OR MACHINE SCREW. i I NON-CONDUCTIVE MATERIAL. a c ° 17. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, a ° SMOKE AND WATER PENETRATION BY FILLING ANNULAR SPACE BETWEEN PIPING AND SLEEVES WITH DOM. WATER ISOMETRIC INTUMESCENT CAULK, TO ACHIEVE THE SAME RATING AS WALLS OR FLOORS, AS PART OF THE CONCRETE PLUMBING CONTRACTOR'S WORK. FLOOR N.T.S. SLAB 18. PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE BY OWNER. SHUT-OFF VALVE CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED. 19. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES. ACCESS PANELS IN RATED WALLS SHALL NOTE: 1-1/4" COLD WATER MAINTAIN THE SAME RATING AND SHALL MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED. PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES SUPPLY LINE. NOT SERVED WITH A FLOOR CLEANOUT: LOCATE ABOVE FIXTURE FLOOD RIM 20. PROVIDE COMBINATION CLEANOUT PLUG AND COVER PLATE OR ACCESS PANEL FOR ALL WALL WITHIN 4' OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. K�z CLEANOUTS. FINISH TO MATCH NEARBY FIXTURE TRIM. 1" STAINLE 21. NO COMBUSTIBLE MATERIAL SHALL BE INSTALLED IN MECHANICAL ROOMS NOR IN CEILING SPACES STEEL STAY-OPEN WHERE USED AS RETURN AIR PLENUMS. BALL VALVE. STAINLESS 22. NO WATER, SANITARY OR DRAINAGE PIPING SHALL BE INSTALLED IN ELECTRICAL OR ELEVATOR STEEL PULL-ROD. EQUIPMENT ROOMS. WALL CLEANOUT DETAIL 23. ALL CONTROL VALVES SHALL BE TAGGED AND MARKED. A REPRODUCIBLE DIAGRAM LOCATING ALL NOT TO SCALE 1/2" STAINLESS 1-1/4" FEMALE VALVES SHALL BE FURNISHED FOR OWNER/OPERATOR. STEEL STAY-OPEN INLET (PLUGGED). 24. CONDENSATE DRAIN PIPING SHALL BE TYPE "L" COPPER WITH ARMAFLEX INSULATION AND A BALL VALVE. VAPOR-BARRIER JACKET PER FLORIDA BUILDING CODE 7TH EDITION (2020) - ENERGY SHOCK ARRESTOR SCHEDULE CONSERVATION, TABLE C403.2.8. PVC WITHOUT INSULATION IS ACCEPTABLE FOR RISERS AND BELOW GRADE PIPING. WHEN USED IN A RETURN AIR PLENUM, PVC PIPING WITH INSULATION IS ACCEPTABLE P.D.I. DESIGNATION MANUF. & MODEL FIXTURE UNITS CONNECTION NOTE: IN LOCATIONS WHERE ALLOWED BY LOCAL CODES. CONDENSATE PIPING SHALL NOT DRAIN ONTO THE EMERGENCY EYE WASH & SHOWER SAFETY ROOFING SYSTEM NOR ANY OF ITS COMPONENTS. CONDENSATE PIPING ARRANGEMENT IS EXEMPT A SIOUX CHIEF 652-A 1-11 1 2" STAINLESS STEEL BOWL STATION SHALL BE A BRADLEY MODEL #S19-310, FROM MINIMUM EQUIPMENT CLEARANCE REQUIREMENTS PER FLORIDA BUILDING CODE 7TH EDITION / CORROSION RESISTANT AND ALL-STAINLESS (2020), SECTION 1522.3.5. ALL HORIZONTAL RAINWATER PIPING RUN ABOVE FINISHED FLOOR THAT B SIOUX CHIEF 653-B 12-32 3/4" STEEL. SAFETY STATION TO BE AS SPECIFIED RECEIVES CONDENSATE DISCHARGE SHALL BE INSULATED WITH ARMAFLEX AND A VAPOR-BARRIER OR APPROVED EQUAL. JACKET. C SIOUX CHIEF 654-C 33-60 1" 25. HOT WATER PIPING INSULATION SHALL BE PROVIDED IN ACCORDANCE WITH FLORIDA BUILDING CODE SIOUX CHIEF SHOCK ARRESTORS APPROVED FOR INSTALLATION WITH NO 7TH EDITION (2020) - PLUMBING, TABLE 607.5 & FLORIDA BUILDING CODE 7TH EDITION (2020) - ACCESS DOOR REQUIRED. CONFORMS TO ANSI/ASSE 1010 STANDARDS. 1-1/4" OUTLET ENERGY CONSERVATION, TABLE C403.2.8. CONTRACTOR SHALL USE ARMAFLEX OR EQUAL WHERE �TO FLOOR DRAIN. APPLICABLE. WHERE DOMESTIC WATER TEMPERATURES CAN CAUSE SWEATING, ALL COLD WATER PIPING SHALL BE INSULATED WITH ARMAFLEX INSULATION AND A VAPOR-BARRIER JACKET, PER SLOPE OF HORIZ. DRAINAGE PIPE STAINLESS STEEL FLORIDA BUILDING CODE 7TH EDITION (2020) - ENERGY CONSERVATION, TABLE C403.2.8. FLOOR FLANGE. SIZE (inches) MINIMUM SLOPE (inch per foot) 26. AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO VENT PIPING THRU ROOF WHERE ACCEPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION. INSTALLATION METHODS SHALL BE IN 2-1/2 or less 1/4 FINISHED FLOOR ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND REQUIREMENTS. 27.PROVIDE ANGLE STOPS ON ALL WATER SERVICE LINES TO FIXTURES FOR INDIVIDUAL 3 to 6 1/8 SHUT-OFF. 28.STUDOR MINI/MAXI AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO 8 or larger 1/16 VENT PIPING THRU ROOF WHERE ACCEPTABLE BY THE PLUMBING OFFICIAL AND LOCAL CODES. INSTALLATION SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS. TABLE 704.1 OF THE FLORIDA PLUMBING CODE 2020 EYE WASH AND SHOWER DETAIL 29.ALL HORIZONTAL RAINWATER PIPING THE RECEIVES CONDENSATE DISCHARGE FROM AIR Architect: CONDITIONING EQUIPMENT SHALL BE INSULATED WITH 1" THK. ARMAFLEX. NOT TO SCALE 30.PLUMBING PLANS IN GENERAL, ARE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ IN CONJUNCTION WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, FIRE SPRINKLER, STRUCTURAL AND CIVIL PLANS AND SHALL BE CONSIDERED AS ONE SET OF DOCUMENTS. PIPING MODIFICATIONS SUCH AS OFFSETS, BENDS, TRANSITIONS, AND SIZES SHALL BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE FUNCTIONAL SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. CHANGES IN PIPE SIZES AND ROUTING SHALL BE REQUIRED BY THE CONTRACTOR TO AVOID CONFLICTS AND TO ADAPT TO EXISTING FIELD CONDITIONS PROVIDED THAT INSTALLATION MEETS ALL APPLICABLE CODES. 31. SUPPLY TRAP PRIMER FOR ALL FLOOR DRAINS, FLOOR SINKS, HUB DRAINS, ETC. SHOWN ON PLANS. D O N A D I O 32.CONTRACTOR TO FIELD VERIFY ALL SUPPLY PRESSURE REQUIREMENTS AND LIMITATIONS. PROVIDE PRESSURE REDUCING VALVE IF REQUIRED. & Associates, Architects P.A. 2001 91h Avenue,Suite 308 Vero Beach,FL 32960 Tel.772.794.2929 Fax.772.562.8600 www.donadio-arch.com License No.AA0002238 Consultant: ABLDG DEPT 2021-09-02 PLUMBING NOTES Digitally signed by Bradly L Brown Drawing Title: P.E. R DN: cn=Bradly L Brown P.E., o=Kamm EXISTING CONDITIONS EXTERIOR ELEVATIONS m m Consulting Inc., ou=FL# 58232, email=jmayr@kammconsulting.com, Reference North Consulting c=us Date: 2021 .09.02 09:32:56 -04'00' Di Drawing File: ISSUED FOR PERMIT ONLY 06-23-21 MT NOT FOR PRICING OR CONSTRUCITON Chd: XREF File: AJ D KAMM CONSULTING PROJECT#: 2021-0167 Project No.: Plot File: PROJECT MANAGER: JOHN MAYR 1408 Orange Avenue 2020-33 m Fort Pierce,Florida 34950 Sheet No.: okAPhone 954.448.0792 Cert. No.: 12456 jmayr@kammc onsulting.com Comm 11g Certification of Authorization#8189 Date Signed: PRINCIPAL 09-02-21 P 0 Brad: L Brown Florida License#58232 Y date signed Copyright ©2020,Donadio&Associates.Architects,P.A.,All Rights Reserved