Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2021-0167E5-1-E5-1
EX. FPL VAULT MAIN ELECTRICAL ROOM Project: 6 SETS - 4-400MCM & 1#2/OG - 3-1/2" RENOVATION OSERVICE ENTRANCE RATED F O R 2000A 65K 2 SETS - 4-350MCM & 1#1 G - 3" 4800/277V 30Ll ` MSBEll VAULT CONTENDER TRANSFORMER MDP1 PANEL MDP2 MDP3 PANEL MDP4 PANEL MDP5 PANEL 75KVA 75KVA 75KVA 75KVA "D" "A" „C" „B„ BOATS 200A Ell STEPDOWN STEPDOWN STEPDOWN STEPDOWN TRANSFORMER TRANSFORMER TRANSFORMER TRANSFORMER 800A Ell SPARE GRADE EN 5701 ENVIRONMENTAL DRIVE ST. LUCIE COUNTY, FLORIDA 4-#4/0 & 1#2G 1 2-1/2" J4-#4/0 & 1#2G IN 2-1/2" 4-#4/0 & 1#2G IN 2-1/2" 4-#4/0 & 1#2G IN 2-1/2" 1 2G 1#2G 1#2G 1#2G 1 3#2 & 1#6G IN 1-1/4" = 2 SETS - 4-600MCM & 1#3/OG - 4" 3#2 & 1#6G IN 1-1/4" = 3#2 & 1#6G IN 1-1/4" = 3#2 & 1#6G IN 1-1/4" 2 SETS - 4-3/0 & 1#2G - 2-1/2" G 6 ELECTRICAL RISER NOTES G G O 1# 3/0 GROUNDING ELECTRODE CONDUCTOR C/W IN 1" SCHEDULE 40 PVC CONDUIT. EXOTHERMIC CONNECTION. ELECTRICALLY CONT- G G INUOUS STEEL REINFORCING BAR IN BOTTOM OF BUILDING FOUNDATION IN DIRECT CONTACT WITH EARTH. 4 3 10 FT. LONG x 3/4" DIAMETER COPPER DRIVEN S S U e S G GROUND ELECTRODE. No,: Date: Description: 3 O EXOTHERMIC CONNECTION. (TYPICAL) A. - - O MAKE CONNECTION TO METALLIC COLD WATER 10'-0„ ENTRANCE PIPE BEFORE FIRST VALVE WITH HEAVY DUTY BRONZE GROUND CLAMP. O PROVIDE 1# 3/0 BONDING JUMPER AROUND FIRST VALVE. O CONTRACTOR TO COORDINATE VAULT STUB GEAR & TOP- HAT WITH EQUIPMENT SUPPLIER. MAON ELEC TF-1 COAL F-1 SEG1 NOT TO SCALE SCHEDULE OF DISTRIBUTION PANEL "MDP4" SCHEDULE OF BRANCH CIRCUIT PANEL "D" SCHEDULE OF BRANCH CIRCUIT PANEL "A" MAIN: 400 AMP / 3 POLE, MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE SPEC: SQUARE D OR APPROVED EQUIVALENT AIC SYMM: 65,000 MAIN: 200 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 208/12OV, 30, 4 WIRE MAIN: 200 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 208/12OV, 30, 4 WIRE CIRCUIT BREAKER A PHASE B PHASE C PHASE SPEC: SQUARED OR APPROVED EQUIVALENT SPEC: SQUARE D OR APPROVED EQUIVALENT DESIGNATION DESCRIPTION FRAME TRIP POLES FEEDER KVA KVA KVA NOTES MOUNTING: SURFACE AIC SYMM: 22,000 MOUNTING: SURFACE AIC SYMM: 22,000 MDP4-1 WELDER - 20 3 3#12 & 1#12 G - 1/2" 4.4 4.4 4.4 DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE B PHASE C PHASE CKT. TRIP COND. GND. WIRE DESCRIPTION DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE B PHASE C PHASE CKT. TRIP COND. GND. WIRE DESCRIPTION MDP4-2 WELDER - 20 3 3#12 & 1#12 G - 1/2" 4.4 4.4 4.4 KVA KVA KVA KVA KVA KVA MDP4-3 WELDER - 20 3 3#12 & 1#12 G - , 2 4.4 4.4 4.4 RECEPTACLES #12 #12 1/2-"'-- 20 1 1.0 1.0 2 20 1/2" #12 #12 RECEPTACLES RESIN PUMP 3#8 1#10 1 35 1 2.1 2.1 2 35 1 1#10 3#8 RESIN PUMP MDP4-4 WELDER - 20 3 3#12 & 1#12 G - 1 2 4.4 4.4 4.4 RECEPTACLES 12 12 1 2" 20 3 1.0 1.0 4 20 1 2" 12 12 RECEPTACLES 3 2.1 2.1 4 MDP4-5 WELDER - 20 3 3#12 & 1#12 G - 1/2" 4.4 4.4 4.4 FAN #12 #12 1/2" 20 5 0.3 0.3 6 20 1/2" #12 #12 FAN 3 5 2.1 2.1 6 3 MDP4-6 CRANE FINAL ASSEMBLY - 60 3 3#6 & 1#10G - 1" 13.3 13.3 13.3 FAN 12 12 1/2- 20 7 0.3 0.3 8 20 1/2" 12 12 FAN RESIN AGITATOR 3#12 1#12 1/2" 15 7 0.6 0.6 8 15 1/2" 1#12 3#12 RESIN AGITATOR MDP4-7 LIGHTING - 20 1 1#12 & 1#12G -1/2" 1.2 - - DROP CORD POWER #12 #12 1/2" 20 9 1.0 1.0 10 20 1/2- #12 #12 DROP CORD POWER 9 0.6 0.6 10 MDP4-8 LIGHTING - 20 1 1 12 & 1 12G -1 2" - 1.2 - RECEPTACLES #12 #12 1 2 20 11 0.8 - 12 20 - - - SPARE 3 11 0.6 0.6 12 3 MDP4-9 LIGHTING - 20 1 1#12 & 1#12G -1 2 - - 1.2 POOL PUMP 3#12 1#12 1/2- 20 13 1.2 - 14 20 - - - SPARE TANK 1 WATER PUMP 2#12 1#12 1/2" 1 13 0.8 0.8 14 1 1/2" 1#12 2#12 TANK 2 WATER PUMP MDP4-10 BIG ASS FAN - 15 3 3 12 & 1 12G -1 2" 0.9 0.9 0.9 15 1.2 - 16 20 - - - SPARE 2 15 0.8 0.8 16 2 MDP4-11 BIG ASS FAN - 15 3 3#12 & 1#12G -1 2 0.9 0.9 0.9 3 17 1.2 - 18 20 - - - SPARE TANK 1 WATER HEATER 2#10 1#10 3/4"_::3 17 2.5 2.5 18 3 3/4" 1#10 2#10 TANK 2 WATER HEATER MDP4-12 PANEL "C" VIA XFMR - 110 3 3#2 & 1#6G IN 1-1 4 6.7 6.6 6.1 SPARE - - - 20 19 - - 20 20 - - - SPARE 2 19 2.5 2.5 20 2 45.0 44.9 44.4 KVA PER PHASE SPARE - - - 20 21 - - 22 20 - - - SPARE CHILLER CONTROL 3#6 1#10 1" 60 21 5.8 1.0 22 20 1/2" 12 12 RESIN TANK 1 LOAD CELL J-BOX 162.5 162.1 160.3 AMPS PER PHASE SPARE - - - 20 23 - - 24 20 - - - SPARE 23 5.8 1.0 24 20 1/2" #12 #12 RESIN TANK 2 LOAD CELL J-BO 134.3 TOTAL KVA SPARE - - - 20 25 - - 26 20 - - - SPARE 3 25 5.8 - 26 20 - - - SPARE SPARE - - - 20 27 - - 28 20 - - - SPARE SPARE - - - 20 27 - - 28 20 - - - SPARE SPARE - - - 20 29 - - 30 20 - - - SPARE SPARE - - - 20 29 - - 30 20 - - - SPARE SPARE - - - 20 31 - - 32 20 - - - SPARE SPARE - - - 20 31 - - 32 20 - - - SPARE SPARE - - - 20 33 - - 34 20 - - - SPARE SPARE - - - 20 33 - - 34 20 - - - SPARE SPARE - - - 20 35 M 36 20 - - - SPARE SPARE - - - 20 35 - - 36 20 - - - SPARE SCHEDULE OF DISTRIBUTION PANEL "MDP5" SPARE - - - 20 37 - - 38 20 - - - SPARE SPARE - - - 20 37 - - 38 20 - - - SPARE SPARE - - - 20 39 - - 40 20 - - - SPARE SPARE - - - 20 39 - - 40 20 - - - SPARE SPARE - 42 20 - - - SPARE SPARE - - - 20 41 - - 42 20 - - - SPARE MAIN: 400 AMP / 3 POLE, MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE 3.8 5.2 KVA PER PHASE 17.8 13.8 17.2 KVA PER PHASE SPEC: SQUARE D OR APPROVED EQUIVALENT AIC SYMM: 65,000 31.7 43.3 AMPS PER PHASE 148.3 115.0 143.3 AMPS PER PHASE DESIGNATION DESCRIPTION CIRCUIT BREAKER FEEDER A PHASE B PHASE C PHASE NOTES 11.6 TOTAL KVA 48.8 TOTAL KVA FRAME TRIP POLES KVA KVA KVA MDP5-1 5 AXIS CNC - 55 3 3#6 & 1#1 OG IN 1 12.2 12.2 12.2 MDP5-2 CNC VACUUM - 40 3 3 8 & 1#1 OG IN 1" 8.9 8.9 8.9 MDP5-3 UPHOLSTERY ACCESS ELEVATOR - 60 3 3#6 & 1#1 OG IN 1 13.3 13.3 13.3 MDP5-4 PANEL B VIA XFMR - 110 3 3#2 & 1#6G IN 1-1 4 17.5 21.4 15.8 SCHEDULE OF DISTRIBUTION PANEL "MDP1" MDP5-5 LIGHTING - 20 1 ,#12 & 1#12G - , 2 1.2 - - SCHEDULE OF BRANCH CIRCUIT PANEL "B" MDP5-6 LIGHTING - 20 1 1 12 & 1 12G - 1/2- - 1.2 - MDP5-7 CNC VENTILATION - 20 3 3#12 & 1#12G - 1/2" 1.9 1.9 1.9 MAIN: 600 AMP / 3 POLE, MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE MDP5-8 EF-2 - 20 3 3 12 & 1 12G - 1/2" 4.2 4.2 4.2 SPEC: SQUARE D OR APPROVED EQUIVALENT AIC SYMM: 65,000 MAIN: 200 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 208/12OV, 30, 4 WIRE MDP5-9 - - - - - - - - CIRCUIT BREAKER A PHASE B PHASE C PHASE SPEC: SQUARE D OR APPROVED EQUIVALENT DESIGNATION DESCRIPTION FEEDER NOTES MOUNTING: SURFACE AIC SYMM: 22,000 FRAME TRIP POLES KVA KVA KVA 55.0 58.9 52.1 KVA PER PHASE MDP1-1 PANEL "D" VIA XFMR - 110 3 3#2 & 1#6G IN 1-1/4" 3.8 5.2 2.6 DESCRIPTION WIRE GND. COND. TRIP CKT. A KVA KVA B PHAKVASE C PHAKVA CKT. TRIP COND. GND. WIRE DESCRIPTION NOTES: 198.6 212.6 188.1 AMPS PER PHASE MDP1-2 LIGHTING - 20 1 1#12 & 1#12G IN 1/2" 1.2 - - FIBERGLASS CUTTER 3#10 1#10 3/4" 30 1 2.9 3.4 2 30 3/4" 1#10 3#10 FIBERGLASS CUTTER VACUUM 166.0 TOTAL KVA MDP1-3 LIGHTING - 20 1 1#12 & 1#12G IN 1 2 - 1.2 - MDP1-4 LIGHTING - 20 1 1 12 & 1 12G IN 1/2- - - 1.2 3 2.9 3.4 4 MDP1-5 LIGHTING - 20 1 1#12 & 1#12G IN 1/2- 1.2 - - 3 5 2.9 3.4 6 3 MDP1-6 LIGHTING - 20 1 1 12 & 1 12G IN 1 2" - 1.2 - SEWING MACHINE #12 #12 1 2 20 7 0.7 2.9 8 30 3/4" 1#10 3#10 MEZZANINE HVAC MDP1-7 LIGHTING - 20 1 1#12 & 1#12G IN 1/2- - - 1.2 RECEPTACLES 12 12 1 2" 20 9 1.0 2.9 10 SCHEDULE OF MAIN SWITCH BOARD "MSB" MDP1-8 CRANE _ 60 3 3 & 1 10 - 1" 134 1 .4 1 .4 RECEPTACLES #12 #12 1/2" 20 11 1.0 2.9 12 3 Architect: MDP1-9 COMPRESSER 20 3 3#12 & 1#12G - 1/2- 4.4 4.4 4.4 RECEPTACLES 12 12 1/2- 20 13 1.0 1.0 14 20 1/2- 12 12 RECEPTACLES MDP1-10 COMPRESSER - 20 3 3 12 & 1 12G - 1/2- 4.4 4.4 4.4 AHU-1 2#6 1#10 3/4" 6 15 5.6 2.9 16 4 3/4" 1#10 2#8 CU-1 MAIN: 2000 AMP / 3 POLE, MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE MDP,-11 VACUUM PUMP - 20 3 3#12 & 1#12G - 1/2" 4.4 4.4 4.4 2 17 5.6 2.9 18 2 SPEC: SQUARE D OR APPROVED EQUIVALENT AIC SYMM: 65,000 MDP,-12 POOL CRANE - 60 3 3#6 & 1 10 - 1" 13.3 13.3 13.3 AHU-2 2#6 1#10 3/4" 6 19 5.6 (2.9) 20 4 3/4" 1#10 2#8 CU-2 CIRCUIT BREAKER A PHASE B PHASE C PHASE MDP,-13 EXHAUST FAN - 20 3 3#12 & 1#12G - 1/2" 1.9 1.9 1.9 2 21 5.6 2.9 22 2 DESIGNATION DESCRIPTION FEEDER NOTES MDP,-14 EXHAUST FAN 20 3 3 12 & 1 12G - 1 2 1.9 1.9 1.9 SPARE - - - 20 23 - - 24 20 - - - SPARE FRAME TRIP POLES KVA KVA KVA SPARE - - - 20 25 - - 26 20 - - - SPARE MSB-1 MDP1 - 600 3 - - - 49.8 51.2 48.6 49.8 51.2 48.6 KVA PER PHASE SPARE - - - 20 27 - - 28 20 - - - SPARE MSB-2 MDP2 - 600 3 - - - 6.8 8.0 6.8 NOTES: 179.8 184.8 175.5 AMPS PER PHASE SPARE - - - 20 29 - - 30 20 - - - SPARE MSB-3 MDP3 - 800 3 2 SETS - 4-600MCM & 1 3 OG - 4 69.9 65.9 69.3 149.6 TOTAL KVA SPARE - - - 20 31 - - 32 20 - - - SPARE MSB-4 MDP4 - 400 3 2 SETS - 4-3 40 & 1 2G - 2-1 2 45.0 44.9 44.4 SPARE - - - 20 33 - - 34 20 - - - SPARE D O N A D I O MSB-5 MDP5 - 400 3 2 SETS - 4-3/0 & 1 2G - 2-1/2'- 55.0 58.9 52.1 SPARE - - - 20 35 - - 36 20 - - - SPARE MSB-6 SPARE - 800 3 2 SETS - 4-600MCM & 1 3 OG - 4 - - - SPARE - - - 20 37 - - 38 20 - - - SPARE MSB-6 TVSS - 2-1/2-- - - SPARE - - - 20 39 - - 40 20 - - - SPARE & Associates, Architects P.A. 211.5 228.6 221.2 KVA PER PHASE SCHEDULE OF DISTRIBUTION PANEL "MDP2" SPARE - - - 20 41 - - 42 20 - - - SPARE 20019thAvenue,Suite308 811.9 676.6 792.8 AMPS PER PHASE 17.5 21.4 15.8 KVA PER PHASE Vero Beach,FL 32960 676.6 TOTAL KVA 145.8 178.3 131.7 AMPS PER PHASE Te1.772.794.2929 MAIN: 600 AMP / 3 POLE, MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE 54.7 TOTAL KVA Fa.dona www.donadio-arch.com SPEC: SQUARE D OR APPROVED EQUIVALENT AIC SYMM: 65,000 License no.AArch.23 License No.AA0002238 DESIGNATION DESCRIPTION CIRCUIT BREAKER FEEDER A PHASE B PHASE C PHASE NOTES FRAME TRIP POLES KVA KVA KVA SCHEDULE OF DRY-TYPE TRANSFORMERS MDP2-1 LIGHTING _ 20 1 1#12 & 1#12G IN 1/2" - 1_2 _ Consultant: MDP2-2 LIGHTING 20 , , 12 & , 12G IN 1/2- 1.2 SCHEDULE OF BRANCH CIRCUIT PANEL "C" MDP2-3 LIGHTING - 20 1 1#12 & 1#12G IN 1/2" - 1.2 VOLTAGE SECONDARY FEEDER MDP2-4 LIGHTING - 20 1 1#12 & 1#12G IN 1/2- - - 1.2 MARK KVA PRIMARY SECONDARY MOUNTING MARK BREAKER FEEDER NOTES MDP2-5 BIG ASS FAN - 15 1 1 12 & 1 12G -1/2- 0.9 0.9 0.9 T1D 75 480 VOLT 208/120 VOLT - T1D-1L O 4#4/0 & 142G - MDP2-6 BIG ASS FAN - 15 1 1#12 & 1#12G -1/2- 0.9 0.9 0.9 MAIN: 200 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 208/12OV, 30, 4 WIRE 30,3W 30,4W IN 2-1/2 MDP2-7 EXHAUST FAN - 20 3 3 12 & 1 12G - 1 2" 1.9 1.9 1.9 SPEC: SQUARE D OR APPROVED EQUIVALENT - - - - - - - - MDP2-8 EXHAUST FAN - 20 3 3#12 & 1#12G - 1/2- 1.9 1.9 1.9 MOUNTING: SURFACE AIC SYMM: 22,000 RISER DIAGRAM MDP2-9 EF-1 - 20 3 3 12 & 1 12G - 1/2- 4.2 4.2 4.2 DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE B PHASE C PHASE CKT. TRIP COND. GND. WIRE DESCRIPTION MDP2-10 - - - - - - - - KVA KVA KVA NOTE: 6.8 8.0 6.8 KVA PER PHASE DROP CORD POWER 12 12 1 2 20 1 1.0 1.0 2 20 1 2 12 12 DROP CORD POWER NOTES: 24.5 28.9 24.5 AMPS PER PHASE DROP CORD POWER #12 #12 1/2" 20 3 1.0 1.2 4 20 1/2" #12 #12 HYDRAULIC BENDER Q PANEL MAIN BREAKER IS TRANSFORMER SECONDARY BREAKER. SAW 12 12 1 2" 20 5 1.2 1.2 6 20 1 2" 12 12 GRINDER 21.6 TOTAL KVA SAW #12 #12 1/2" 20 7 1.2 1.2 8 20 1/2" #12 #12 GRINDER SAW 12 12 1/2- 20 9 1.2 1.2 10 20 1/2" 12 12 GRINDER SAW #12 #12 1/2" 20 11 1.2 1.2 12 20 1/2" #12 #12 GRINDER RECEPTACLES 12 12 1 2" 20 13 1.0 1.0 14 20 1 2" 12 12 RECEPTACLES SCHEDULE OF DISTRIBUTION PANEL "MDP3" RECEPTACLES 12 12 1 2 20 15 1.0 1.0 16 20 1 2 12 12 DROP CORD POWER RECEPTACLES #12 #12 1/2" 20 17 1.0 0.3 18 20 1/2" #12 #12 FAN FAN 12 12 1/2- 20 19 0.3 0.3 20 20 1/2" 12 12 FAN MAIN: 800 AMP / 3 POLE, MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE SPARE - - - 20 21 - - 22 20 - - - SPARE SPEC: SQUARE D OR APPROVED EQUIVALENT AIC SYMM: 65,000 SPARE - - - 20 23 - - 24 20 - - - SPARE SPARE - - - 20 25 - - 26 20 - - - SPARE CIRCUIT BREAKER A PHASE B PHASE C PHASE SPARE - - - 20 27 - - 28 20 - - - SPARE DESIGNATION DESCRIPTION FEEDER NOTES SPARE - - - 20 29 - - 30 20 - - - SPARE FRAME TRIP POLES KVA KVA KVA Drawing Title: MDP3-1 PANEL A VIA XFMR - 110 3 3#2 & 1#6G IN 1-1 4 17.8 13.8 17.2 SPARE - - - 20 31 - - 32 20 - - - SPARE MDP3-2 CRANE - 60 3 3#6 & 1#10 - 1 13.3 13.3 13.3 SPARE - - - 20 33 - - 34 20 - - - SPARE MDP3-3 SPRAY BOOTH EXHAUST - 20 3 3 12 & 1 12G - 1/2- 0.8 0.8 0.8 SPARE - - - 20 35 - - 36 20 - - - SPARE EXISTING CONDITIONS MDP3-4 SPRAY BOOTH EXHAUST - 20 3 3#12 & 1#12G - 1/2- 0.8 0.8 0.8 SPARE - - - 20 37 - - 38 20 - - - SPARE MDP3-5 SPRAY BOOTH EXHAUST - 20 3 3 12 & 1 12G - 1 2" 0.8 0.8 0.8 SPARE - - - 20 39 - - 40 20 - - - SPARE EXTERIOR ELEVATIONS MDP3-6 SPRAY BOOTH EXHAUST - 20 3 3#12 & 1#12G - 1/2- 0.8 0.8 0.8 SPARE - - - 20 41 - - 42 20 - - - SPARE MDP3-7 SPRAY BOOTH EXHAUST - 20 3 3 12 & 1 12G - 1/2- 0.8 0.8 0.8 6.7 6.6 6.1 KVA PER PHASE MDP3-8 SPRAY BOOTH EXHAUST - 20 3 3#12 & 1#12G - 1/2" 0.8 0.8 0.8 55.8 55.0 50.8 AMPS PER PHASE MDP3-9 SPRAY BOOTH VENTILLATION - 20 3 3#12 & 1#12G - 1/2- 0.8 0.8 0.8 19.4 TOTAL KVA Reference North MDP3-10 SPRAY BOOTH VENTILLATION - 20 3 3 12 & 1 12G - 1 2" 0.8 0.8 0.8 MDP3-11 SPRAY BOOTH VENTILLATION - 20 3 3#12 & 1#12G - 1/2- 0.8 0.8 0.8 MDP3-12 SPRAY BOOTH VENTILLATION - 20 3 3 12 & 1 12G - 1 2" 0.8 0.8 0.8 MDP3-13 SPRAY BOOTH VENTILLATION - 20 3 3#12 & 1#12G - 1/2- 0.8 0.8 0.8 MDP3-14 SPRAY BOOTH VENTILLATION - 20 3 3 12 & 1 12G - 1 2" 0.8 0.8 0.8 MDP3-15 DUST COLLECTION - 40 3 3#8 & 1#1OG - 1 6.9 6.9 6.9 MDP3-16 DUST COLLECTION - 40 3 3 8 & 1#1 OG - 1" 6.9 6.9 6.9 MDP3-17 DUST COLLECTION - 40 3 3#8 & 1#10G - 1" 6.9 6.9 6.9 Drn: Drawing File: MDP3-18 DUST COLLECTION - 40 3 3#8 & 1#10G - 1" 6.9 6.9 6.9 Digitally signed by Bradly L ISSUED FOR PERMIT ONLY 06-23-21 MT MDP3-19 SPRAY BOOTH LIGHTING - 20 3 3#12 & 1#12G - 1/2- 0.8 0.8 0.8 NOT FOR PRICING OR CONSTRUCITON Chd: XREF File: MDP3-20 SPRAY BOOTH LIGHTING - 20 3 3 12 & 1 12G - 1/2 0.8 0.8 0.8 Bradly L Brown P.E. 69.. 65.. 69.. KVA PER PHASE D N: c n=B ra d I L Brown P.E., KAMM CONSULTING PROJECT#: 2021-0167 AJ D NOTES: 252.3 237.9 250.2 AMPS PER PHASE y PROJECT MANAGER: JOHN MAYR Project No.: Plot File: 205.1 TOTAL KVA o=Kamm Consulting Inc., 2020-33 Brown 14rt Orange Avenue OU=FL# rJ8232, Fort Pierce,Florida 34950 Sheet No.: 954.448.0792 Cert. No.. 12456 e m a i l=j m ay r@ ka m m co n s u l t i jmayr@kammconsulting.com 011s11 Ilg Certification of Authorization#8189 ng.eom, e=U$ PRINCIPAL 08-12-21POEO Date Signed: Brad: L Brown Florida License#58232 E591 Date: 2021 .08.1215:16:05 y date -04'00' signed Copyright ©2020,Donadio&Associates,Architects,P.A.,All Rights Reserved