Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED ENERGY CALCS & MANUAL J - 31 ECUADOR WAY(1)
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type01432.0 sgft.) Insu€ation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft2 Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 208.00 ft23. 4. Number of Bedrooms 3 c. NIA d. N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling Types (1783.0 sgft.) R_ ft2 Insulation Area 6. Conditioned floor area above grade (ft2) 1753 a. Under Attic (Vented) b. Knee Wail (Vented) R=30.0 1753.00 ft2 R=19.0 30.00 ft2 Conditioned floor area below grade (fife) 0 c. NIA R= ft2 7. Windows(151.4 sqf -) Description Area 12. Ducts R ft2 a. U-Factor Sgl, U=1.02 111 36 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 195 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40,00 ft2 SHGC: SHGC=0.27 13. Cooling systems kBtu/hr Efficiency c. U-Factor: NIA ft2 a. Central Unit 34.8 SEER:15.00 SHGC: Area Weighted Average Overhang Depth: 2_880 ft, 14. Heating systems k6tu/hr Efficiency Area Weighted Average SHGC: 0.285 a. Electric Heat Pump 34.8 HSPF:8.50 S. Skylights Area c. U-Factor.(AVG) NIA ft2 SHGC(AVG): NIA 15. Hot water systems 9. Ffoor T es 1753.0 s ft. yp ( g ) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features EF: 0.970 b. N/A R' ft2 Norte c. NIA R= ft2 16. Credits None Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49.38 Total Baseline Loads: 50.69 PASS I hereby certify that the plans and specifications covered by Review of the and this calculation are in compliance with the Florida Energy plans specifications �E Code, covered by this calculation indicates compliancezz PREPARED BY: with the Florida Energy Code. DATE: 1-12-20121 Before construction is completed this building will be inspected for 7y v compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/ NT: DATE: BUILDING OFFICIAL: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.'I. - Compliance requires an Air Barrier and Insulation Inspection envelope leakage test report with envelope leakage Checklist in accordance with R402.4.1.1 and this project requires an no greater than 5.00 ACH50 (R402.4.1.2). 1/12/2021 1:15 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Winter Summer Degree Days Moisture Daily Temp Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiI ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 5 LAUDRY 6 BEDROOM 2 7 DINING/GREAT R 8 KITCHEN 9 BATH 61 488 No 0 36 288 No 0 180 1440 No 0 588 4704 No 2 209 1672 Yes 0 50 400 No 0 1 1 1 1 1 1 1 Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type 1 Slab -On -Grade Edge Insulatio Space Perimeter Perimeter R-Value MASTER BEDRO 37 It 0 Area 224 It- Joist R-Value _ Tile Wood 0 1 Carpet 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 _ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH , 8 ft 0 56 ft2 _ 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 fF 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 _ 0 1 0 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - F1aRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6SIab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 — 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN lift 0 209 ft2 _ 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 It 0 50 ft2 — 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 — 0 1 0 11Slab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 -_- 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 f12 0 1 0 ROOF / Roof Gable Roof Red Solar $A Emitt Emitt Deck Pitch t/ # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC i V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood _ 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 R2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 13 Knee Wall (Vented) DINING/GREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block - Int InsMASTER BE 4.1 16 0 8 0 128.0 tt2 0 0 0.3 0 2 SW=>NE Exterior Concrete Block - Int InsMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 _ 3 NW=>SE Exterior Concrete Block- Int InsMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHF_C:KI VAT RFPART WALLS Adjacent Space Cavity Width Height Sheathing Framing _ Solar Below , 4 NE=>SW Exterior Concrete Block - Int InsMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 5 NE=>SW Exterior Concrete Block - Int Insul M. BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.3 0 6 NE=>SW Exterior Concrete Block - Int Ins®EDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.3 0 7 SW=>NE Exterior Concrete Block- Int InsIDINING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.3 0 8 NW=>SE Exterior Concrete Block - Int Ins(DINING/GRE 4.1 20 0 8 0 160.0 W 0 0 0.3 0 9 SW=>NE Exterior Concrete Block- Int Insul KITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 10 NE=>SW Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 11 SE=>NW Exterior Concrete Block - Int Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 12 SW=>NE Exterior Concrete Block- Int Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 13 NE=>SW Exterior Concrete Block- Int InsBIEDR00M 3 4.1 13 0 8 0 104.0 ft' 0 0 0.3 0 14 SW=>NE Exterior Concrete Block - Int Ins81EDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 15 N=>S Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft' 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated FOYER None .39 3 3 6 8 21.7 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.02 0.29 Y 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>SW 5 Metal Low-E Single Yes 1.02 0.29 Y 6.9 ft' 1 ft 0 in 1 ft 4 in None None 3 NE=>SW 6 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft' 1 ft 0 in 1 ft 4 in None None 4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29 Y 39.8 ft' 1 ft 0 in 1 ft 4 in None None 5 NW=>SE 8 Metal Low-E Single Yes 1.11 0.27 Y 40.0 ft' 8 ft 0 in 1 ft 4 in None None 6 NE=>SW 13 Metal Low-E Single Yes 1.02 0.29 Y 16.2 W 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft' 26 ft 8 ft 11 INFILTRATION Method SLA CFM 50 ELA EWhSo'lehpouse EgLA ACH ACH 50 Proposed ACH(50) .000254 1168.7 64.12 120.37 .0902 5 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cent # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / — Supply — -- Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 195 ft2 Attic 55 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Feb VenDec ting L 1 Jan Feb Mar [ ]X Mar Apr Apr € May Jun Jul Aug 4[x�1Novlx1j Sep OctO N Dec [ N� l l Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.fL 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Defauk(8 lbs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8 lbs/sq.ft. i ft2 ft 0.3 M. BATH Default(81bs/sq.ft. ft2 ft 0.3 LAUDRY Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.fL ft2 ft 0.3 DINING/GREAT R Default(8 lbs/sq.ft. ft2 ft 0.3 riTrucni 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft- ft 0.3 HALL Default(S lbs/sq.ft. ft- ft 0.3 FOYER Default(8 lbsts.ft. ft2 ft 0.3 BEDROOM 3 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE W INDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: r Owner: Jurisdiction: w Design Location: FL, Fort Pierce x O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and anygaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door iambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including above -garage insulation. maintain permanent contact with the underside of and cantilevered subfloor decking, or floor framing cavity insulation floors) shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be out to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be out neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall ���Laod wiring Shower/tub The air barrier installed at exterior wails adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids .. o In additi..n Inenani'rnn of Inn u��11c n6.J1 ti�:....___-�____.._.� �_ ___ , ..... ..... . __...,. . 1-1-1 ... .... a .. .--1-1 —,,, awvwai iw wiui u1v yiovisans of IhU4uv. 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-202C ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (fF) 7. Windows" Description a. U-Factor: Sgl, U=1.02 SHGC: SHGC=029 b. U-Factor. Sgl, U=1.11 SHGC: SHGC=0.27 c. U-Factor: N/A SHGC: d. U-Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): WA THE WINDSOR, FT. PIERCE, FL, New (From Plans) 10. Wall Type and Insulation Detached a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Adjacent 1 c. N/A 3 d. WA Yes 11. Ceiling Type and insulation level a. Under Attic (Vented) 1753 b. Knee Wall (Vented) Area c. N/A 111.36 ft- 12. Ducts, location & insulation level a. Sup: Attic, Ret Attic, AH: Attic 40.00 ft2 13. Cooling systems ft2 a. Central Unit Gii 2.850 ft. 0.285 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft- b. N/A R= ft2 c. N/A R= ft2 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: `� Date: Address of New Home:3\ � C V Q lX \ -J 0.i( City(FL Zip: , �,-efts F`-t3yg 5 � Insulation Area R=4.1 1224.00 ft2 R=11.0 208.00 ft- R= fF R= ft2 Insulation Area R=30.0 1753.00 ft2 R=19.0 30.00 ft2 R= ft2 R ft2 6 195 kBtu/hr Efficiency 34.8 SEER:15.00 kBtu/hr Efficiency 34.8 HSPF:8.50 Cap: 40 gallons EF: 0.97 None *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 Project Summary �1 Wrightsiofit® Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Ptrne 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM Project Information For. WYNNE DEVELOPMENT THE W INDSOR, FT. PIERCE, FL Notes: Design Information Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21542 Btuh Structure 16420 Btuh Duds 6191 Central vent (0 cfm) 0 Btuh Btuh Ducts Central vent (0 clin) 9337 0 Btuh Btuh none Humidification 0 Btuh (none ) Blower 0 Btuh Piping 0 Btuh Equipment load 27734 Btuh Use manufacturer's data n Infiltration Rate/swin multiplier Equipment load 0.95 sensible 24470 Btuh Method Simplified Construction quality Average Latent Cooling Equipment Load Sizing Fireplaces 0 Structure 2495 Btuh Ducts 2546 Btuh Central vent (0 dm) 0 Btuh Heatingg Area(fe) Cool' (none) 1753 1753 Equipment latent load 5041 Btuh Volume (ft') 16478 16478 Airchanges/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 29511 Btuh Equiv.AVF (cfm) 104 55 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536A'030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point= 36 OF 8.5 HSPF 34600 Btuh @ 47-F 27 OF 1160 cfm 0.042 Cfm/Btuh 0 in H2O Backup: Input=7kW, Output=23009Btuh. 100AFUE Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536XO30 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiencey 12.0 EER,15 SEER Sensiblcooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 Cirri Airflowfactor 0.045 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.84 Calculations approved byACCAto meet all requirements of Manual J 8th Ed -� � wrjspft o`ft^ 2021-Jao-1213:18:18 RNE-S e®NDSO el2019 19.021 RSU08101 �...DowrerlslWrigF�RHVHGYWYNNE-TIiE WINDSORnp CaIc=MIB Frar¢OoorfacesN Paget wrightsoft° RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Ptore: 772-4666799 Fax 772-4666796 Emil: QUICKQ4LCS@ppL.COM 1 Room name Entire House BEDROOM 2 EmosRoom 207.6 ft 41.0 ft 3 n ge i Room deign 9.6 R d 9.4 R heaV000l 4 Room dimensions 74A x 20.0 ft 5 Room area 1753.0 ff 280.0 fF Ty Consrumon U-value Or HTM Area (R') Load Area ( Load number (BWhdF°F) (RWhlftr) or perimeter (ft) (BWh or perimeer (ft) (Bhlh) Heat Cool Gross MPS Heat Cool Gross MPS Heat Cool 6 UI/ 13AA= 0.143 n 4.00 2.55 649 596 2386 1517 66 66 263 167 1A-dom 1270 n 35.56 34.77 15 0 533 522 0 0 0 0 L_CG 4A5-2om 0.770 n 2156 19.31 38 0 815 730 0 0 0. 0 W 13A-0as 0.143 ne 4A0 2.55 27 27 106 68 0 0 0 0 11 13A-4ocs 0.143 a 4.00 2.55 141 100 400 255 0 0 0 0 1Ac1cm 1270 a 35.56 87.06 20 1 711 1741 0 0 0 0 11D0 0.390 a 1092 11.31 21 21 229 238 0 0 0 0 W 13AAM 0.143 se 4.00 2.55 27 27 106 68 0 0 0 0 13A-4= 0.143 s 4.00 2.55 536 530 2121 1349 188 188 753 479 1Actom 1270 s 3556 34.77 6 6 213 2D9 0 0 0 0 13A-4ors 0.143 w 4.00 2S5 320 255 1022 649 132 108 432 275 tAclom 1270 w 35.56 5453 12 1 415 636 12 1 415 636 1Ac1om 1270 w 35.56 54.53 12 1 427 MA 12 1 427 654 4A5-2om 0.770 w 21.56 45.63 41 2 880 1862 0 0 0 0 P 12C-0sv 0.091 - 2.55 128 254 254 647 326 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 1753 1753 1571 4067 280 280 251 650 F 22A-tpl 0.989 - 27.69 0.00 I 1753 208 574E 0 280 41 1135 0 6 c)AEDe=ursor. 397 488 Envelope loss/gain 18331 15285 3676 3349 12 a) Infiltration 3211 905 720 200 b) Roomlenblafion 0 0 0 0 13 Internal gains: Omtpants@ 230 1 230 0 Applianoes(olner 0 0 0 SUbbfal (lines 6In 13) 21542 16420 4405 3554 Lese�mal load 0 0 0 Lewtransler 0 0 0 RedishoLdon 0 0 0 0 14 15 Subtotal Ductloads 21542 16420 0 4405 0 3554 29% 57% 6191 9337 29% 57% 1266 2021 Total loom load 27734 25757 5- ---- Airrequired(Qm) 1160 1160 237 251 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed �A • r wrlg/sEaoTt^ ITigt[Sdte® Uaversel 201919.021 RSU08101 2021-Jarv7213a8a8 ...Do rtMW69ttwft HVACIWVNNE-TI-EWINDSORnp Caic=NJe rrordDoorfares: N Page wrghtsoft- Right-.l® Worksheet Job: Entire House Date: By.QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE. FL 34946 PWne: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC MASTER BATH 2 Exposed wall 0 ft 9.0 ft 3 Room height 9.4 ft heaYcool 9.4 ft heaUc of 4 Room dimentions 7.0 x 9A It 7.0 x 9D ft 5 Room area 63.0 fF 63.0 ff Ty Construction U-value Or HTM Area (f?) Load Area number (BNhW--°Fj (BWhNF) or perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heat Cool Grp WPIS Heat Cool Gros N/R/S Heat Cool 6 13A4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 T 1Ac1om 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 2156 19.31 0 0 0 0 0 0 0 0 W 13A4o's 0.143 ne 4.DO 255 0 0 0 0 0 0 0 0 11 v�1 13A4= 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 �G 1Aclom 1270 a 3556 87.06 0 0 0 0 0 0 0 0 �D 11DO 0.390 a 1092 11.31 0 0 0 0 0 0 0 0 W 13A4ors 0.143 se 4.00 255 0 0 0 0 0 0 0 0 Vj/ 13A4os 0.143 s 4.00 2.55 0 0 0 0 85 85 339 215 `G 1Actom 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A4ors 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 IA-clom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 1Achom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 45.631 0 0 0 0 0 0 0 0 P 12C-Ow 0.091 - 2.55 1.281 0 0 0 0 0 0 0 0 C 16A90md 0.032 - 0.90 2.32 63 63 56 146 63 63 56 146 F 2244131 0.989 27M 0.00 63 0 0 0 63 9 249 0 6 c)AEDeuursion -10 -28 Envelopeiossfon 56 136 644 334 12 a) MIt aeon 0 0 160 45 b) Roomvenfllafion 0 0 0 0 0 13 Internal gains Occupants@ 230 0 p p Appliancs/other 0 0 0 Sublotal(lines6m13) 56 136 804 379 Lesealemalload 0 0 0 0 Les transfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subhrtal Ductloads 136 804 379 29% 57% 16 77 29% 57% 231 216 Total room load 73 214 1036 595 Air required(rim) 3 10 43 27 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed wri9MLsoP[- - A&A Right-Suferg 202tJarv1213:18:18 Unversal 201919,021 RSUD8101 Page 2 ..wne .DortslWdgttsoftHVAQWYNNE-THEWINDSORnp Cal'=MI8 Front DoorfarzsN -r{i- wrightsoft- RighWO Worksheet Date: t° Entire House QUICK CALCS, INC. ey 3175T. LUCIE UN, FL PIERCE, FL 34946 Piers: 772-466-6799 Pax 772-466E796 Email: QUICKCALCS@AOL.COM 1 Room name ABATH KITCHEN 2 Exoosedwall 8.0 It 8D It 3 Room height 9.4 it heatlmol 9.4 it heaNcnol 4 Room dimensions 7D x 8D It 1.0 x 172.0 It 5 Room area 56.0 ff 172.0 ft' Ty Constuclion U-value Cr HTM Area Load (fly Load number (Bbrhill °T) (BWhAF) or perimeter (ft) (Bhfi) oorperimeter (it) (Bt/h) Heat Cool Gross N/P/8 Heat Cool Gross WP5 Heat Cool 6 y/ 13AA= 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 I�-GG tAclom 1270 In 35.56 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 W 13A4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 4y 13A-4= 0.143 a 4A0 2.55,0 0 0 0 0 0 0 0 1Ac1om 1270 a 35.55 87.06 0 0 0 0 0 0 0 0 I�-DG 11D0 0.3M a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4ocs 0.143 se 4.00 2,55 0 0 0 0 0 0 0 0 t-G 13A4ocs 0.143 s 4.00 2M 75 69 277 176 0 0 0 0 1Aclom 1270 s 3556 34.77 6 6 213 209 0 0 0 0 13AA= 0.143 w 4.00 2S5 0 0 0 0 0 0 0 0 I--G 1Actom 1270 w 36.56 5453 0 0 0 0 0 0 0 0 1Aclom 1270 w 35.56 51.53 0 0 0 0 0 0 0 0 4A5-2om O.nO w 21.56 45.63 0 0 0 0 D 0 0 0 P 12C-0sa 0.091 - 2.55 128 0 0 0 0 75 75 192 96 C 16A-30md 0A32 - 0.90 2,32 56 56 50 130 172 172 154 399 F 22A-tpl 0.989 - 27.69 1.00 56 I 8 222 0 172 8 222 0 6 c)AEDe=;rsion 38 34 Envelope lossrgain 7sz an 567 462 12 a) MItaton I 142 40 0 0 b) Roomventlaton 0 0 0 0 13 Internal gains: Ooorpants@ 230 p p p Appliances/otter 0 p 0 SubbbI (lines 6 to 13) 904 517 1 567 462 Lessextemal load 0 0 0 0 Lestansier 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 904 517 5662 15 Duo:loads 29% 57% 260 294 29% 57% 163 263 Total room load 1164 811 730 725 Air required (am) 49 37 31 33 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed wrMgl�MOT!- 9 A RigtSae9.021 RSU08W1 2021-Jan1213:18:18 _.COurts\WrgftroftVACWYNNE-THEWINDORw CBIc=MB FrordDoorfacesN Page -L wrightsoft° Right-M Worksheet '°a Entire House Dfit QUICK CALCS, INC. By. 317 ST. LUCIE LN.. FT. PIERCE. 9- 34946 Prore: 772-466-6799 Fax 772-466.6796 Email: QUICKC4LC8@,AOLCOM 1 Room name BATH BEDROOM2 2 Eposedwall 5.0 ft 42B ft 3 Room height 9.4 ft heaV=l 9.4 ft heaNmol 4 Room dimensions 9.0 x 5.0 t 1.0 x 204A ft 5 Room area 45.0 R2 204.0 ft2 Ty Consbucion U-value Or HTM Area (fF) Load number (I3UhMF-'9 (BU Mt2) or perimeter(R) (Btih) oorpedmeeer (ft) (Bluh) Heat Cool Gross NIPS Heat Cool Gros NIPS Heat Cool 6 VII 13A4as 0.143 n 4.00 2.55 47 47 188 120 132 132 527 335 1Ac1an 1270 n 35M 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 W 13A4o s 0.143 ne 4.00 2.55 0 0 0 0 27 27 106 68 11 13A� 0.143 a 4.00 2.55 0 0 0 0 85 65 259 164 1Ac1am 1270 a 3556 87.06 0 0 0 0 20 1 711 1741 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 w 13AAo 0.143 se 4.00 2.55 0 0 0 0 27 27 106 68 vpr _ 13AAM 0.143 s 4.00 2.551 0 0 0 0 132 132 527 335 �--c� 1Aclom 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A4a 0.143 w 4.00 2551 0 0 0 0 0 0 0 0 IA-dom 1270 w 3556 54.531 0 0 0 0 0 0 0 0 1Actom 1270 w 3556 54M 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 45M 0 0 0 0 0 0 0 0 P 12C-Ow 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 45 45 40 104 204 204 183 473 F 22A-tpl 1 0.989 27.69 0.00 45 5 138 0 204 43 1179 0 6 c)AEDe=raon -17 -99 Envelope losslgain 367 207 3599 3085 12 a) Infiltralion b) Roomaentlaton 89 5 750 214 0 02 0 0 13 Intemalgains: O=pants@ 230 0 0 0 Appliancestofher 0 0 0 Subbtal(lines6to13) 4� 232 4357 3--- Lesexfernal load 0 0 Les4ansfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Sublogl Ductloads 456 232 0 4357 0 3299 29% 57% 131 132 29% 570/c 1252 1876 Toil room load Air required (cfm) 587 364 5609 5175 25 i6 235 233 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed Af...RgFSE021 RS 2021-JarF1213:18:18 CowrislWdgSoftHAQW7NNE-THWINDSORrLp Calc=M8 FrortDDorho=sN Page wrighWoft Right-J® Worksheet Jo' Entire House Date: QUICK CALCS, INC. BY 317 ST. LUCIE LN., FL PIERCE, FL 34946 Ptone 772466.6799 Fax T 2466-6796 Email: OUICKCALCSC&AOL.COM 1 Room name ENTRY LAUNDRY 2 Bpomdwall 18.0 ft 13.0 R 3 Room heigtc 9.4 R heaV=f 9.4 R heatwol 4 Room dimensons 1.0 x 92.0 ft 710 x 6.0 R 5 Room area 92.0 IF 42.0 fF TY Construction U-value Or HTM Area Load number (BWh/flz-* r) (BWh4F) or pedme�r (R) (BWh) oorperimeeies (ft) (BWh) Heat Cool Gros N/P/S Heat Cool Gross NIPS Heat Cool 6 6p/ 13A-4ors 0.143 It 4.00 2.55 0 0 0 0 0 0 0 0 1Aciom 1270 n 3556 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 W 13A4ors 0.143 no 4.00 2.55 0 0 0 0 0 0 0 0 11 VLI13A4o s 0.143 a 4.00 2.55 56 35 142 90 0 0 0 0 1Ac1an 1270 a 3556 87.06 0 0 0 0 0 0 0 0 11D0 0.390 a 1092 11.31 21 21 229 238 0 0 0 0 W 13A4o s 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 VI/ 13A4os 0.143 s 4.00 2.55 0 0 0 0 56 56 226 144 L-c 1Actam 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A4= 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Aciom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 1Aclom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 4AS2om 0.7 o w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C-Dsw 0.091 2.55 128 113 113 287 145 66 66 168 84 C 16Aa0md 0.032 - 090 2.321 92 92 82 213 42 42 38 97 F f 22Ag1I 0.989 - 27.69 0.00 92 18 498 0 42 13 360 0 6 c)AEDesanson 49 -24 Envelope loss�9ain 1239 637 791 301 12 a) Infiltraton 107 30 107 30 b) Room erriiaton 0 0 0 0 13 Internal gains: Omlpants@ 230 t 0 0 0 0 Applianoes(other 1 0 0 Subtotal (fines 6to 13) 1346 667 898 331 Less eternal loac 0 0 0 0 Less transfer 0 0 0 0 RedisiibuBon 0 0 0 0 14 Sublotal 1346 667 898 331 15 Dud loads 29% 57% 387 379 291 57% 258 788 Total mom load 1733 1047 1156 520 Airrequired(dm.) 72 47 48 23 Calculations approved bvACCAto meet all requirements of Manual J 8M Ed 2021-Jan-121318:18 RgttTHE WINDSOPRpversal GaI9.021R Franc D1 Page5 ...WamerfslWngtbIRHVACWYNNE-TFIE WINDSORnp CaIc=MIB FrontDoorfacesN F�I wrightsar Right-M Worksheet Jcb*. Entire House Date: QUICKCALCS, INC. By. 317 ST. LUCIE LN., FL PIERCE, FL 34946 Phore: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 I Room name GREAT/DINING Room7 2 Evosedwall 50.0 ft 13.0 It 3 Room height 9.4 It heat/mol 9.4 It heaVmol 4 Room dimensions 1.0 x 567.0 ft 13A x 13.0 It 5 Room area 567.0 ff 169.0 ft' Ty Construction U-value Or HTM Area (et Load Area (" Load number (BWMP-°F) (BGihfi[� or perim�r (ft) (BWh) or perimeter (ft) (BNh) Heat Cool Gross N/P/S Heat Cool Gross WP5 Heat Cool 6 lQ/ ! 13A-0ois 0.143 n 4.00 2S5 282 244 978 622 122 107 429 273 II--GG 1Aclom 1270 n 35.56 34.77 0 0 0 0 15 0 533 522 4A5-2om 0.770 n 21.56 1931 38 0 815 730 0 0 0 0 W 13A-4= 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 13A fors 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 tAclom 1270 a 35.56 87.06 0 0 0 0 0 0 0 0 11DO 0.390 a 10.92 1131 0 0 0 0 0 0 0 0 w 13A4o s 0.143 se 4.00 255 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 tA<tom 1270 s 35.56 34.77I 0 0 0 0 0 0 0 0 13A4ors 0.143 w 4.00 2S5 188 147 589 375 0 0 0 0 1Actom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 1Aclom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 4A5.2om 0.770 w 21M 45.63 41 2 880 1862 0 0 0 0 P 12C-0sx 0.091 255 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 232 567 567 508 1315 169 169 151 392 F 22A-Ipl 0.989 - 27.69 0.00 567 5( 1385 0 169 13 360 0 6 C)AED excursion -100 Envelope loss/gain 1474 1086 12 a) Infittralion 231 65 b) Roomvenolation 0 0 13 hberrlal gains O=pants@ 230 01 M=29% Applianombilher 230 0 Sublotal(Ilrles6 b 13) 1705 1387LesexaYmalload0 Les4ans(erRedistributian 0 0 0 14 Subtotal 0 0 15 Duct loads 29°, 5M. 1705 1381 29% 57°/ 490 785 Total room load Airrequired(dn:) 7780 8566 2195 2167 325 386 92 98 Calculaflons approved bvACCA to meet all requirements of Manual J 8th Ed 2021Ja 1213:18:18 .4 A RigkSEWINDSOR 2) C-lc021 RSU08107 ...Doamer6\Wngtb�ft HVAgWYNNE-THE WINOSORnp CaIc=M16 Fror¢WortarQs:N Page ® Duct System Summary Job.' Date: Entire House BY QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34W Phore:772-466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 1160 clam 0 ft Supply Branch Detail Table Cooling 0 in H2O 0 in H2O 0 in H2O 0.000 /0.000 in H2O 0 in/100ft 1160 cfln Name Design (Btuh) Fh Htg (Clm) Clg (Cfrn) Design FR Diam (in) H x W (in) Dud Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 364 25 16 0 0 Ox 0 ShMt 0 0 BEDROOM C 2788 119 126 0 0 OXO ShMt 0 0 BEDROOM2 h 2587 117 117 0 0 Ox0 ShMt 0 0 BEDROOM2-A h 2587 117 117 0 0 OXO ShMt 0 0 BEDROOM -A c 2788 119 126 0 0 Ox0 ShMt 0 0 ENTRY h 1047 72 47 0 0 Ox0 ShMt 0 0 GREATIDINING c 2855 108 129 0 0 Ox 0 ShMt 0 0 GREATIDINING-A C 2855 108 129 0 0 OXO ShMt 0 0 GREATAINING-B C 2855 108 129 0 0 Ox0 ShMt 0 0 KrrCHEN C 725 31 33 0 0 Ox0 ShMt 0 0 LAUNDRY h 520 48 23 0 0 OxO ShMt 0 0 M. BATM h 811 49 37 0 0 Ox 0 ShMt 0 0 M4STERSATH h 595 43 27 0 0 Ox0 ShMt 0 0 Room7 C 2167 92 98 0 0 Ox 0 ShMt 0 0 wlc C 214 3 10 1 0 0 Ox 0 ShMt 0 0 Return Branch Detail Table Name Grille Size (in) Htg (dm) Clg (C(n) TEL (ft) Design I FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening(in) Dud Mat Trunk rb1 0x0 1160 1160 O 0 0 0 Ox 0 ShMt .� & wrightsoft= 2021-Jam1213:18:19 •w...-. v.P.. FbgF(Sute®Unversa1201919.021 RSUOStOt ...D a r6lWngftmttHVAC1WYNNE-THEWINDSORrL4) Calc=M18 Front .Ifaces: N Page