HomeMy WebLinkAboutSurvey�5 L c, P
21r,5- �
RECEIVED
S E P 3 0 2021"°r,
-3t. Lucie COUntY
'P2Ra�aItaTTp
(70
G-1
R=780.00' N.R.
L=3q.18'
A=2'52'42'
GB=N73'40'5G'W
GD=3q.18'
G-2
R=410.00' N.R.
L=82.00'
A=11'27'34'
GB=N77'5B'22'W
GD=81.87'
L-1
NOO'41'2G'W 183.82'
2' CURB
FND
DRAINAGE DITC11
50' F.P.F.W.C.D. CANAL w-
TOP OF BANK
GO' DRAINAGE R/W
89*19'07"E 118.00' FN NORTH LIMITS OF PLAT
Cm
10' PUBLIC U+D E5MT.i
I �
I �
� I
I I a
I
I
I
Wa
I
I WELL
I
+
lT
s-N
I
m
GONG
GENERATOR
I
C\
P
O
I
24.
WELL
PUMP
w
(�
PLASTIC ON BLKS
N
3
A/C� 2.2•
GONG.
FASTNG
LOT 25
A/NG
I
•
DONE
0.4' WEST
I GARAGE
1 STORY
C
.1 .` % ,
EL20.w
�21.8_
CBS
25
1I
Q
2q,3,
#3407
In
F.F.EL.=21.2'
37'14•
i.
0,7.
a " EXISITNG,
23.2•
•_
�I CONC.DR
I
FND
A�
2' CURB
- ADDITION
F.F.EL.=21.24' f
I
m f
b-
I.R.
`✓ `-z 10
PUBLIC U+f
FND G. ESMr.
NT
w VARIFS ' .0
PAVPM£N
2' CURB
THIS SURVEY MAP AND REPORT OR C❑PIES THEREOF ARE -
NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED
SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER.
WI LIAM E. I-IAYI-IVItST
r:eormasIONAr, XAxn Num myo as M"PEIs
MolemA RZOlaTRATION RO 4410
LOT 24
FND G.M. wV
CATCH wv
D4 wv wV
C PRIVATE R/W)
8�,
G
MANHOLE
' CURB
I_{ , I' 23
KNJ[A Engineering & Surveying, LLC
{
Consulting Engineers & Surveyors
.. 234514th Ave. Suite 3 Vero Beach, Fl. 32960
Phone: (772) 569-6680 Fax: (772) 770-3446 E-Malil: survey@kmafl.com
ENGINEERING & S(JRVEYING Certificate of Authorization Number: L.B.8351
LEGEND
OF SURVEY ABBHEVIATIDNS
HEAD WALL
A
DELTA ANGLE
H.W.
A/C
AIR CONDITIONER
L.
LENGTH
AVE.
AVENUE
7;I
LIGHT POLE
AVG.
AVERAGE
M.
MEASURED
R&
BEARING BASE
M.H.
MANHOLE
It
BASELINE
M.H.W.L. MEAN HIGH WATER LINE
B.M.
BENCH MARK
MON.
MONUMENT
BLK.
BLOCK
N&D
NAIL 6 DISK
BLVD.
BOULEVARD
N.
NORTH
B.S.L.
BUILDING SETBACK LINE
No.
NUMBER
C.
C.B.
CURVE
CHORD BEARING
N.IC.
NOT INCLUDED
C.B.S.
CONCRETE BLOCK
O.H.W.
OVERHEAD WIRES
STRUCTURE
pG.
PAGE
D.
CHORD DISTANCE
P.K.
PARKER KALON NAIL
CENTERLINE
PP.C.
PLAT
C.L.F.
CHAIN LINK FENCE
POINT OF CURVATURE
C.D.
CHORD DISTANCE
P,C,P,
PERMANENT CONTROL POINT
C.M.
CONCRETE MONUMENT
pI
POINT OF INTERSECTION
C.MP.
CORRUGATED METAL PIPE p
PROPERTY LIFE;
C.
CONCRETE
P.M.
POWER METER
C.R. R.
COUNTY ROAD
P,O,B.
PONT OF BEGINNING
CT.
COURT
P,O,C,
POINT OF COMMENCEMENT
C/S
CONCRETE SLAB
PRC
POINT OF REVERSE CURVE
CDR,
CORNER
PAX
PERMANENT REFERENCE MONUMENT
D.
DEED
PROP.
PROPOSED
D.B,
DEED BOOK
Cla)
POWER PaE
DEP
DEPARTMENT OF
RAD.
RADIAL OR RADIUS
ENVIRONMENTAL PROTECTION
R/W
RIGHT OF WAY
DIST,
DISTANCE
S.
SOUTH
DNR
DEPARTMENT OF
SEC.
SECTION
NATURAL RESOURCES
SQFT.
SQUARE FEET
DR.
DRIVE
S.R.
STATE ROAD
E.
EAST
ST.
STREET
ESMT.
EASEMENT
STA.
STATION
ELEC.
ELECTRICAL
STRUC.
STRUCTURE
EL
ELEVATION
SUB.
SUBDIVISION
E.O.W.
EDGE OF WATER
T.B.M.
TEMPORARY BENCH MARK
F.F.
FINISHED FLOOR
TELE.
TELEPHONE
FND,
FOUND
T.O,B,
TOP OF BANK
'a
FIRE HYDRANT
TOPO.
TOPOGRAPHICAL
F,P.L.
FLORD7A POWER IL LIGHT
TR.
TRACT
I.P.
IRON PIPE
TWSP,
TOWNSHIP
I.R.
IRON ROD
U & D
UTILITY & DRAINAGE
INV.
INVERT
U.R.
UNREADABLE
IRR,
IRRIGATION
W.
WEST
GOV'T
GOVERNMENT
CM
WATER METER
GR.
GRADE
WV
WATER VALVE
GND.
GROUND
A—
COMBINED LOTS
HORZ. HORIZONTAL
N.P. HIGH POINT
LEGAL DESCRIPTION: ALL OF LOT 25
MONTE CARLO COUNTRY CLUB UNIT ONE
ACCORDING TO THE PLAT THEREOF AS RECORDED
IN PLAT BOOK 23, PAGE 25 OF THE PUBLIC
RECORDS OF ST. LUCIE CO.. FLORIDA. SAID LANDS
LYING IN ST. LUCIE CO., FLORIDA.
CONTAINING 0.54 ACRES MORE OR LE55
1. LANDS SHOWN HEREON WERE NOT ABSTRACTED
FOR RIGHTS -OF -WAY AND/OR EASEMENTS OF
RECORD.
2. THIS SURVEY IS CERTIFIED ONLY TO THE BELOW
NAMED INDIVIDUALS.
3. LEGAL DESCRIPTION SUPPLIED BY CLIENT.
4. SQ. FT. OF HOUSE (IF SHOWN) SUPPLIED BY
CLIENT.
5. NO STRUCTURES OR UTILITIES THAT ARE
BENEATH THE SURFACE HAVE BrEiv LOCATED.
6. ALL SET CAPS LABELED PSM WEH 4416 ARE
SUPPORTED WITH AN 18" LONG #5 REBAR.
ALL FOUND CAPS ARE A 5/8" ROD WITH A CAP
AS LABELED ON SURVEY.
ALL FOUND REBAR ARE A 5/8" ROD UNLESS
OTHERWISE NOTED.
7. ALL LOT DIMENSIONS ARE PLAT AND MEASURED
UNLESS OTHERWISE NOTED.
8. BEARING BASE ON WEST LINE OF LOT 25
CERTIFIED TO:
FELIX DENMON
SURVEY TYPE:
FLOOD ZONE: X
BOUNDARY/TOPO
DATE:
REVISIONS:
BY:
EFFECTIVE DATE: 02/15/12
PNL NO.: 12111CO160 J
CHECKED BY: W.E.H.
03/09/16
PROPOSED ADDITION
KKB
07/12/21
FORMBOARD LOCATION
JPL
DRAWN BY: K.K.B.
08/31/16
REVISED SURVEY
LEH
09/27/21
AS -BUILT SURVEY
SMD
FIELD BOOK: 348
04/26/17
REVISED HOUSE PLAN
LEH
150 ® INDICATES EXISTING ELEVATION
INDICATES PROPOSED ELEVATION
INDICATES AS -BUILT ELEVATION
ELEVATIONS ARE FOR CALC,
PURPOSES ONLY,
PAGE NO 79
06/21/17
REVISED PER REQUEST
BDR
FIELD DATE: 01 14 16
12/21/17
REVISED PER REQUEST
JDJ
SCALE: 1 "-30,
05/17/21
UPDATED SURVEY
LEH
JOB NO: 21--2371
EF�118-015
O6/22/Z1
UPDATED SURVEY
SMD