Loading...
HomeMy WebLinkAboutAPPROVED Soprema_17084.1-R9_CV2020_W-29 wood deck no taper(1)1/21/2021 Florida Building Code Online www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv2aBQpHpQQe9gmYq%2bqxZ1umwAHfht%2fugw%2fus%2f7DTuqgQ%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL17084-R9 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer RESISTO, a division of Soprema, Inc. Address/Phone/Email 1675 rue Haggarty Drummondville, NON-US 00000 (819) 478-2400 Ext 3327 memathieu@soprema.ca Authorized Signature Marc Mathieu memathieu@soprema.ca Technical Representative Marc Mathieu Address/Phone/Email 1675 rue Haggarty Drummondville, NON-US 00000 (819) 478-2400 Ext 3327 memathieu@soprema.ca Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/06/2022 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL17084_R9_COI_2020_01_COI_NIEMINEN.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D1970 2015 ASTM D4601 2012 ASTM D6163 2015 ASTM D6222 2011 ASTM G155 2013 FM 4470 2016 FM 4474 2011 Equivalence of Product Standards Certified By 1/21/2021 Florida Building Code Online www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv2aBQpHpQQe9gmYq%2bqxZ1umwAHfht%2fugw%2fus%2f7DTuqgQ%3d%3d 2/2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/19/2020 Date Validated 09/22/2020 Date Pending FBC Approval 09/29/2020 Date Approved 12/16/2020 Date Revised 12/16/2020 Summary of Products FL #Model, Number or Name Description 17084.1 RESISTO Modified Bitumen Roof Systems SBS modified bitumen roof systems Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-135 Other: 1.) The design pressure noted herein pertains to one assembly. Refer to ER Appendix for all assemblies and maximum design pressures. 2.) Refer to ER Section 5 for Limits of Use. Installation Instructions FL17084_R9_II_2020_09_18_FINAL_A1_ER_RESISTO_MODBIT_FL17084- R9.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL17084_R9_AE_2020_09_18_FINAL_ER_RESISTO_MODBIT_FL17084- R9.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R9 for FL17084-R9 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 9: 09/18/2020 ©2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 1 of 6 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 2 1B Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 3 1C Wood New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 3 1D Wood New, Reroof (Tear-Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 4 1E Wood New or Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 4-5 1F Wood New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 6 1G Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 6 The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: Min. 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non- wind-uplift-related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). 6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions. ➢ RESISTOBOND: Continuous 0.5 to 0.75-inch wide ribbons, max. 12-inch o.c. ➢ DuPont INSTA STIK Quik Set Insulation Adhesive (INSTA STIK): Continuous 0.75 to 1-inch wide ribbons, max. 12-inch o.c. ➢ OMG OlyBond 500: Continuous 0.75 to 1-inch wide ribbons, max. 12-inch o.c. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7 Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. 8 For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). 9 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed c ritical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R9 for FL17084-R9 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 9: 09/18/2020 ©2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 2 of 6 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data She et 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15 For bonded membrane applications, refer to the tables herein. The following are acceptable alternates to the listed membranes. ACCEPTABLE ALTERNATES RESISTO Product Alternate RESISTO LB1236 Beacon Roofing “TRI-BUILT Sand-R SA Shingle Underlayment” PrimeSource Building Products “Grip-Rite Eave & Valley Protector” SRS Distribution “TopShield ICE & WATER DEFENDER” 16 A slip-sheet of Modified Sopra-G or other approved ASTM D4601, Type II fiberglass base sheet may be loose laid atop the wood deck prior to the installation of overlying mechanically fastened components with no adverse effect on system performance. 17 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer(s) Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-1. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, min. 15/32” APA rated plywood or nominal 1” T&G wood plank Min. 1.5-inch ACFoam II, SOPRA- ISO s, H-Shield or SOPRA-ISO r RESISTOBOND, INSTA STIK or OlyBond 500, 12” o.c. (Optional) Additional layers(s) base insulation RESISTOBOND, INSTA STIK or OlyBond 500, 12” o.c. (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self- adhering (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -52.5 W-2. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, min. 15/32” APA rated plywood or nominal 1” T&G wood plank Min. 1.5-inch ACFoam II, SOPRA- ISO s, H-Shield or SOPRA-ISO r RESISTOBOND, INSTA STIK or OlyBond 500, 6” o.c. (Optional) Additional layers(s) base insulation RESISTOBOND, INSTA STIK or OlyBond 500, 6” o.c. (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self- adhering (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R9 for FL17084-R9 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 9: 09/18/2020 ©2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 3 of 6 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Layer(s) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-3. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, min. 15/32” APA rated plywood or nominal 1” T&G wood plank SA Nail Base 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. at 4- inch wide side laps and 8-inch o.c. at three (3) equally spaced rows in the center of the sheet Min. 1.5-inch ACFoam II, SOPRA-ISO s, H-Shield or SOPRA-ISO r RESISTOBOND, INSTA STIK or OlyBond 500, 12” o.c. (Optional) Additional layers(s) base insulation RESISTOBOND, INSTA STIK or OlyBond 500, 12” o.c. (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self- adhering (Optional) RESISTO BITUTAK MB SMOOTH, torch- applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -30.0* W-4. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, min. 15/32” APA rated plywood or nominal 1” T&G wood plank RESISTOFLEX 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at 4- inch wide side laps and 6-inch o.c. at three (3) equally spaced rows in the center of the sheet Min. 1.5-inch ACFoam II, SOPRA-ISO s, H-Shield or SOPRA-ISO r INSTA STIK, 12” o.c. (Optional) Additional layers(s) base insulation INSTA STIK, 12” o.c. (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self- adhering (Optional) RESISTO BITUTAK MB SMOOTH, torch- applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -37.5* W-5. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, min. 15/32” APA rated plywood or nominal 1” T&G wood plank RESISTOFLEX 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at 4- inch wide side laps and 6-inch o.c. at four (4) equally spaced rows in the center of the sheet Min. 1.5-inch ACFoam II, SOPRA-ISO s, H-Shield or SOPRA-ISO r INSTA STIK, 6” o.c. (Optional) Additional layers(s) base insulation INSTA STIK, 6” o.c. (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self- adhering (Optional) RESISTO BITUTAK MB SMOOTH, torch- applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -75.0 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation (Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply W-6. Min. 15/32-inch APA rated plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, SOPRA-ISO s, H-Shield, SOPRA-ISO r Soprema #12 DP Fasteners with Soprema 3” Metal Insulation Plates 1 per 1.6 ft2 (Optional) RESISTO EXTERIOR PRIMER SA Smooth Ply 40 None SA Cap GR or SA Cap FR GR -67.5 W-7. Min. 15/32-inch APA rated plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, SOPRA-ISO s, H-Shield, SOPRA-ISO r Soprema #12 DP Fasteners with Soprema 3” Metal Insulation Plates 1 per 1.6 ft2 (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self- adhering (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R9 for FL17084-R9 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 9: 09/18/2020 ©2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 4 of 6 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply W-8. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, min. 15/32” APA rated plywood or nominal 1” T&G wood plank One or more layers, min. 1-inch, any combination, loose-laid SA Nail Base Trufast #12 DP with Trufast 3” Metal Insulation Plates 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced center rows RESISTO LB1236, self-adhering (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -82.5 W-9. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, min. 15/32” APA rated plywood or nominal 1” T&G wood plank One or more layers, min. 1-inch, any combination, loose-laid MODIFIED SOPRA-G Trufast #12 DP with Trufast 3” Metal Insulation Plates 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced center rows (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -120.0 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners (Note 11) Attach Base Ply Primer Ply Cap Ply W-10. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced rows in the center of the sheet None RESISTO LB1236, self- adhering None (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -30.0* W-11. Min. 7/16-inch OSB or min. 15/32-inch APA rated plywood SOPRA-G or MODIFIED SOPRA-G 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 6-inch o.c. at the 4-inch laps and 6-inch o.c. at four (4), equally spaced, staggered center rows RESISTO EXTERIOR PRIMER SA Base RESISTO EXTERIOR PRIMER None SA Cap GR or SA Cap FR GR -37.5* W-12. Min. 19/32-inch APA rated plywood SOPRA-G 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 7-inch o.c. at the 4-inch laps and 7-inch o.c. at three (3), equally spaced, staggered center rows RESISTO EXTERIOR PRIMER SA Base RESISTO EXTERIOR PRIMER None SA Cap GR or SA Cap FR GR -37.5 W-13. Min. 15/32-inch APA rated plywood SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced, staggered center rows None (Optional) SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -45.0 W-14. Min. 15/32-inch APA rated plywood SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced, staggered center rows None RESISTO LB1236, self- adhering None (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R9 for FL17084-R9 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 9: 09/18/2020 ©2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 5 of 6 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners (Note 11) Attach Base Ply Primer Ply Cap Ply W-15. Min. 15/32-inch OSB or min. 15/32-inch APA rated plywood SOPRA-G 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 6-inch o.c. at the 4-inch laps and 6-inch o.c. at four (4), equally spaced, staggered center rows RESISTO EXTERIOR PRIMER SA Base RESISTO EXTERIOR PRIMER None SA Cap GR or SA Cap FR GR -45.0 W-16. Min. 15/32-inch APA rated plywood SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at the 4-inch laps and 6-inch o.c. at four (4), equally spaced, staggered center rows None RESISTO LB1236, self- adhering None (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -52.5 W-17. Min. 19/32-inch APA rated plywood or nominal 1” T&G wood plank SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced center rows None (Optional) SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -60.0 W-18. Min. 19/32-inch APA rated plywood or nominal 1” T&G wood plank SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced center rows None RESISTO LB1236, self- adhering None (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -60.0 W-19. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB or min. 15/32- inch APA rated plywood GAP Organic Base Sheet (#43) Simplex MAXX Cap Fastener 6-inch o.c. at the 3-inch laps and 6-inch o.c. at three (3), equally spaced center rows None (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied None (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -60.0 W-20. Min. 19/32-inch APA rated plywood or nominal 1” T&G wood plank SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 0.120” x 1.25” ring shank roofing nails 6-inch o.c. at the 4-inch laps and 6-inch o.c. at three (3), equally spaced center rows None (Optional) SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -90.0 W-21. Min. 19/32-inch APA rated plywood or nominal 1” T&G wood plank SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 0.120” x 1.25” ring shank roofing nails 6-inch o.c. at the 4-inch laps and 6-inch o.c. at three (3), equally spaced center rows None RESISTO LB1236, self- adhering None (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -90.0 W-22. Min. 19/32-inch APA rated plywood or nominal 1” T&G wood plank SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 0.120” x 1.25” ring shank roofing nails 4-inch o.c. at the 4-inch laps and 4-inch o.c. at four (3), equally spaced center rows None (Optional) SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -105.0 W-23. Min. 19/32-inch APA rated plywood or nominal 1” T&G wood plank SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 0.120” x 1.25” ring shank roofing nails 4-inch o.c. at the 4-inch laps and 4-inch o.c. at four (3), equally spaced center rows None RESISTO LB1236, self- adhering None (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R9 for FL17084-R9 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 9: 09/18/2020 ©2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 6 of 6 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners (Note 11) Attach Base Ply Primer Ply Cap Ply W-24. Min. 19/32-inch APA rated plywood or nominal 1” T&G wood plank SA Nail Base Trufast #12 DP with Trufast 3” Metal Insulation Plates 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced center rows None (Optional) SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -127.5 W-25. Min. 19/32-inch APA rated plywood or nominal 1” T&G wood plank SA Nail Base Trufast #12 DP with Trufast 3” Metal Insulation Plates 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced center rows None RESISTO LB1236, self- adhering None (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -127.5 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Notes 1 & 12) Primer Roof Cover (Note 15) MDP (psf) Base Ply Primer Ply Cap Ply W-26. Min. 7/16-inch APA rated OSB or min. 15/32-inch APA rated plywood RESISTO EXTERIOR PRIMER SA Base RESISTO EXTERIOR PRIMER None SA Cap GR or SA Cap FR GR -45.0 W-27. Min. 15/32-inch APA rated OSB None SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -67.5 W-28. Min. 15/32-inch APA rated OSB RESISTO EXTERIOR PRIMER SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -75.0 W-29. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, min. 15/32” APA rated plywood (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self-adhering None (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -97.5 W-30. Min. 15/32-inch APA rated plywood None SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -105.0 W-31. Min. 15/32-inch APA rated plywood RESISTO EXTERIOR PRIMER SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -112.5 W-32. Nominal 1” T&G wood plank (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self-adhering None (Optional) RESISTO BITUTAK MB SMOOTH, torch-applied RESISTO BITUTAK MB SMOOTH or RESISTO BITUTAK MB MINERAL, torch-applied -135.0