HomeMy WebLinkAboutCreekside Lot 22 Code 128 (2).pdf[BUNIVERSAL
ENGINEERING SCIENCES
INSPECTION RESULTS
Inspection Date: (} �0 - 9(", �( Permit No
Project: Cq OUY/AJ.,00_0
Address: 3 Y 1 IR-- 1�
Check one:
Regular Inspection:
❑ Reinspection Date of Initial Inspection:
Inspection Type Requested (check):
BUILDING/STRUCTURAL
ELECTRICAL
PLUMBING
MECHANICAL
Footing
Underground
Underground
Duct Rough -In
Slab
Floor Rough -In
Rough -In
Steam Piping & Test
Masonry
Wall Rough -In
Stack Piping & Test
HW Piping & Test
Wall/Ceiling
Ceiling Rough -In
Water Piping & Test
CHW Piping & Test
Framing
Panel/Feeder
Gas Piping & Test
Cond. Piping & Test
Structural
Service/Ground
Storm Piping & Test
Insulation
Sheet Rock
Appliance/Equipment
Fixtures
I Wall & Ceiling
Roofing
Lighting Protection
Equipment
Equipment
Re -inspection
Re -inspection
Re -inspection
Re -inspection
Final Building
Final Electrical I
I
Final Plumbing
Final Mechanical
Other Inspection Type:
Area Inspected/Code:0 8 -
Inspection Results:4P-Approved ❑ AE-Approved with Exceptions ❑ DA-Disallowed
❑ DP -Disapproved ❑ Not Ready
Conditions/Comments: i n"Oro-W aa/
1. 12/ Cl-L �Tb%c--G
2. t'
3.
4.
5.
6.
7.
Inspector's Name: Lic.#: (/✓/v �2, 2,
OFFICES THROUGHOUT FLORIDA
607 NW Commodity Cove, Port St. Lucie, Florida 34986 • (772) 924-3575 • (772) 924-3580 (fax)
www.teamgfa.com
October 19, 2021
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave.
Fort Pierce, FI.34982
(772)462-2172
RE: Permit #
D.R. Horton Homes
Creekside Phase 2 Lot 22
To Whom It May Concern,
We were notified of the existing field conditions of the CMU overhanging the slab at the
above listed project.
Please refer to the following repair below.
H) Masonry Walls Overhanging Foundation A/2" to 4-1/2". In locations where exterior
masonry walls are overhanging the foundation, contractor shall install 2-1/2" Tapcons into the
side of the foundation 12" O.C. Horizontally and 8" O.C. Vertically staggered with 3" space
between top row and top of slab. Retain 1/8"-114" gap between the head of the Tapcon and the
face of the foundation. Using formboards, apply concrete bonding agent and use 3000 psi non
shrink grout to fill the overlap space below the wall the full height of the footer.
Sincerely,
signed
1.10.19
0 �/oARoa 4:47:32-04'00'
Michael C. Anderson
Florida Architect #AR17305
2194 Hwy A I A • Indian Harbour Beach, FL 32937 • Phone: (321) 802-3591
AA0003325
www.abdesigngroup.com