Revision - plans
PARTITION LEGEND " v NORTH DENOTES c a ' MAR 0 2 20% LJ_LLLLLLLL111LLL1. TYP. EXTERIOR WALL - 5/8" STUCCO ON 8" CONC. BLOCK FIRST FLOOR PLAN TRANSFORMER. /!� A3.10 ELECTRIC FROM NEW A6.00 A6.00 �) t -- TRANSFORMER. REFER ,. f /.- / ST, LUCIB County, Permitting EXTERIOR SIDE. 5/8" GYP. BD. SMOOTH FINISH ON R-4.1 DTO E L DRAWINGS FOR DETAAILS, CONTRACTOR C.U. 4 C.U. B FOIL BACK RIGID INSULATION ON 1" PT WD. FURRING ® 24" SCALE: 3/16" = 1 °-0" TO COORDINATE \` `' O.C. INTERIOR SIDE, PAINT BOTH SIDES rI I V VOLD ARYCHITECTURE, INC. -- -- - TYPICAL INTERIOR PARTITION WALL - DD � Y ni 5/8" GYP. BD. SMOOTH FINISH EACH SIDE ON 3 5/8' TRELLIS DESIGN --- ----- METAL STUDS (25 GA. MIN) ® 24" O.C. W/P.T. BOT. PLATE, GREEN WALL RDEN/SHOW t W-118 W 117 j 8000 N. FEDERAL HWY. SUITE 118 PAINTED. REFER To INT W w W W _ ` BOLA RATON, FL 33487 ELEVATIONS - -- --- --� o a N .,, - --- H.B. e - ----- - 1/ - ,�__- P. 561 306 4286 F. 561 9535210 TYPICAL SOUND PARTITION - DENOTES O fi H.B.���� w°o8 L k T-tte w-tts w 123 l; i7 ALU ES LICENSE # A A 26002586 5/8 GYP. BD. SMOOTH FINISH EACH SIDE ON 3 5/8' eRACKETs..............................TT ��I r� TW METAL STUDS (25 GA. MIN) ® 24" O.C. WITH 3-1/2" D10B W,LC. -iEF BAIT INSULATION, W/P.T. BOT. PLATE, PAINTED. r-n9 v goo i ....., .. TYP. 42" HI. EXTERIOR GUARD WALL - 5/8" STUCCO ON D � F- ----- - Il ti p p ALLDES GNSAND DETAILS INDICATED OR H NE FL .` CONC.' BLOC WALLS E�TF§RIOR R-4 1, REPRESENTED BY THIS DRAWING ARE FOR THE USE ON B" CONC. BLOCK, SMOOTH FINISH, PAINT BOTH SIDES. _ z n ... AND INcowuNcnoNwlrH THE sPEanED DENOTES LINE __ _ _ D121 , '` `" \4..G>� L� "LS A, . 7fI46- SLOPE CAP TO EXTERIOR Ya". ES B O v13 1xJAc T R-q l j" PROJECT. TIHS RE, ITHENC. PROPERTY N TRNNVOUD USED OF ROOF ABOVE PRESS BA NCE 1: % , LINEAR ONNHOOKUSHOWER ND DIVERTS L;lI� I,1 �y� 4 L `FL USS- OILING " , t��. R- ',' ARCHrrEcruRE.INc.AND SHAUNo7eEUSEDOR ' I }I REPRODUCED WHOLE OR IN PARTWRH-OUT DENOTES COLUMN WITH CONCRETE BLOCK BASE AND j DRAIN 10'6 --- '. ` " WRITTEN PERMISSION OR BE LIABLE FOR THE FULLEST MASTER BATHi ' I 1�iOF ... Lfi�QER ATTIC 1CYNENE4; R. o �. STEEL COLUMN WITH DECORATIVE WRAP (TYP). r-72o w-12o o CLGv F STONE FL. LEGAL RECOURSE. THE coNTRAcroesHAu VERIFY 0 ERO EDGE ' x• `.' f r ' �`• ""'�Y '� �• ' " I, Ftr` ~ YY ALL EXISTING CONDITIONS AND DIMENSIONS AND OPAQUE1 RAIN SHO R 1Vo CLG. �I j� .,J` -/ ' : (` �A/IlN, 1N ULATION' AS PER,_.ENERGY CA �.,. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES "'.�... PRESS BA NCE '-' T SLR Ti4, f . ' 1 t -`,� 1 PRIOR TO THE EXECUTION OF THE WORK. V man MASTER SUITE v "Al _ __ _ Olt- NO DIVERTS !-'`� �., x ,. -- 4 8L`NGN' R. 10'6 , SYMBOLS LEGEND K ���R_ - L - HAND HE SHOVER`. - r Z -il12Y ' i t 0 CLG. CLG. i1 •� `- l ® NEW DOOR SYMBOL __,_ _,.,..,. L, L ..............•-'......_._.___, __,_, _��.,_ _ _,. _,D W 124 / OPAQUE U �`y/ 0 NEW WINDOW SYMBOL I r-12t w-i2t W.LC, �,, O1 y,.. v 0��� 1 . -. ES Y _ E 10'0 CLG. 1 t ' r ! :, ,: L. .,` .� . �. Pa ` WOOD FLOOR f © FLOOR OUTLINE t.� , \ A �' ` DENdiES,•�ECONp t - GVALL ANTS CEIL FINIS 3 MALL HAVE A FLAME SPREAD INDEX ELEVATION MARK V�` 1.�. SPREAD,- -w• ;ABOV; s i' OF NOT a vo.p 2 INTERIOR ELEVATION MARK j GREAT A - DENotEs TRaY i 2) SMOKE �. DEVE� THAN Ex"5 \\ WALL AND CEILING FINISHES SH DENOTES MAJESTIC WOOD O I =.,.- .,,�, OTE `-T'VkICAL �' `' `,: - /`�.. �,, -_ �' ....:,. .- G 5.L HAVE A SMOKE -DEVELOPED IIIIIIIIIIIIjIIIIIIIIIIIIIIIIId .y 0 F CEI ING SS BLI' 3 r-t2z w-t22 W.LC. I BURN s1DEs.°°LACE ON �� /` � P ICJ .,,/C? "�`Ki. R t'SPREAD �ND» -IVPREAD 0. Y wITN,pEcoenAVE L "INDEX OF NOT'ER THAN 4 X WOOD FLOOR BURNING FIREPLACE oN tVELOPED INDEX FOR INSULATION ELEVATION TARGET ----- ---O'D ----------I ALTERNATE GAS VENTLEss ASSEMBLIES, CRAWL SPACES AND X / O T_12a L BL OVER cDNc. ATTCCS SHALL HAVE, A FLAME INDEX NOT TO EXCEED 25 FIREPLACE -O OYMER Dffi7 j ' SECTION MARK R 00 Dn9 PRIOR BuaD-ouT - srensE mTM TH' 7�N A¢O ° Gyp R1 SMODEVELOPED INDEX NOT TO "1I ___� IVENEER `..•• r r�\ WI',, OF3IPA, SOPS 8" PER FT. J BL j 6• C CONSTRUCTION 0 CONSTRUCTION I , J KEYNOTES j JOINT Y PF �E I JOINT EE ____ ___ ZO PLACrE/TV 2IT [ - - _. _. - __ _ _ _L/ FIRE-. 36" HT, 24" DEEP BASE CABINETS V !, i A _ TOR - - - 0 O P PORCH ST j m WIDTHS VARY. SEE PLANS D ° j z0 I STONE FL � J `. OB 36" HT KITCHEN ISLAND/ BAR T-too w-toD Otto WOOD STONE FLOOR. VARIES CLG. t. ............. OPEN 2 STORY O 24"K48" ATTIC ACCESS W/PULLDOWN LADDER, PROVIDE 100 rl VOLUME j 0'-8 25.d NAVD);r \t O S.F. AREA OF 5/8" PLYWOOD AROUND ATTIC ACCESS FOR t22 L OPt3'-o' R cH N. FL OPORCH STORAGE SUPPORT e" j \ / 6" 0 MIN. 9-pE: 1f• PER Fi.FULL HT TILE BAGKSPLASH, TYPICAL ( O _ __ _ j VAULTED CLG.O 7.09• D SINK WITH DISPOSAL 6' COV ENTRY FOYER I BEAMS �, .. OtOD EXPOSED WOOD t �,' FO TRIMMED OPENING wooD FLOOR O 12" DEEP UPPER CABINETSlto 11 0 CLG. STONE VENEER AND 'i 6" SOFFIT EI HT TO WOOD SIDING WALL. 6. H PRE-FAB WATERPROOFED SHAMPOO CUBBY 36 HEIGHT MiL HAND �� V VAULTED CLG RA6' NEIGH MTL HAND 1 OF DETAILS _ dl �.. '� J\ �•..,.., �1'r -1, EXPOSED WOOD BEAMS REFER TO ID ". NO Ki �ORO 'J ROVGH FIN. FIL DRAWINGS FOR O W� DIMENSIONS AND , . , ""-CONSTRUCTION 0108t - t DWGSAPPRFOR ARCHITECT �� SHOWER AND TUB AREA TO HAVE FULL HEIGHT TILE SURROUNDS TO Otto JOINT - sAPE / O PROVIDE BLOCKING AS REQUIRED FOR ART WORK EXPOSED SJOPE`ERAS SPHROV SUBMIT SHOP O F J \ T 101 W-101 STAIOS WOOD F REFER TO K 30 H 24 DEEP BASE CABINET MAKE UP CPUNTER � � I j ° O CEILING, PROVIDE GREEN BOARD AND RED PAINT WATERPROOF AS REQ'D. g i s a O SHOWER BENCH. SIZE VARIES. REFER TO FLOOR PLAN. WATER PROOF AND I AND GETAILS(J J; s LL_ SLOPE AS REQUIRED. I% I - - - --- �L O RECESSED MEDICINE CABINET _ J /I D105 - O TEMPERED GLASS FRAME -LESS SHOWER ENCLOSURE j 100 SOFFR F� F Q _ o N C9 FIRE PLACE W TV ABOVE. STONE VENEER AND CUSTOM MANTLE. REFER " j s"• -- x� Q O TO IE. COORDINATE FIREPLACE TYPE -GAS VENTLESS OR WOOD BURNING L P 24" HT WALL WITH TEMPERED GLASS SHOWER ENCLOSURE ABOVE K WINE PROVIDE BLOCKING FOR PLASMA SCREEN TV, & OUTLET & CABLE CONNECTIONj ROOM o_ ottl o Q' 05'-0" A.F.F. COORDINATE LOCATION IN FIELD WITH HOMEOWNER. j O o O ALUMINUM DRYER VENT 3 N j " O SUMMER KITCHEN BUILT-IN. STL MT STUDS WITH DURAROCK AND STUCCO AIV Ir'WAY I 11 I j CONSTRUCTION O INSTALL GAS TANKLESS WATER HEATER WITH THERMOSTATIC CONTROL VALVES PAVERS T toz w toz BATHVIP 2r i, PORCHSTONE FLOOR JaNT FOR HOT WATER AS REQUIRED. WA°0E I I j DINING ROOM a; VAULTED CLG O TOILET PAPER HOLDER 3Y OTHERS) I I'D CL . ® O III WOOD FLOOR N 1 TILE O A CoI I' T&G W DECORATIVE lip j l FJ-'FLORCH V TOWEL BAR j I l I RAFTERS o I o'- " zs D' FL 6 D I I z1 j 0104 W BEVELED MIRROR ------- ---T y7, STEEL COL. REFER 3 X BUILT-IN WINDOW SEAT WITH STORAGE BELOW. REFER TO I.E. BAR TO STRUCTURAL � � I WIC I WOOD FLO I l j FOR DETAILS (TYP) O CUSTOM BUILT -OUT CLOSET SYSTEM/SHELVES 1 I /- D III STEEL I BEAM ABOVE, DWGS FOR DETAILS Z CUSTOM OD FLOOR ---- ab-SOFR1--- STRUCTURAL ; D103 Q AA PERMANENT ISCREEN SLLIIDI GO DOORS ANDELEVATIONS PANELS AT PORCH /' 0 CLG. r i a w� � iS' _____ __ L E - --REFER TO STRU ..................... ............. ......i F ... ----- --- B N IN MIRROR ®BATHROOMS ,,/ © EE ---- -- - r-------------- �'\ W PER FT. CC MISTING SYSTEM ®SUMMER KITCHEN j� Q ona HALL STONE VENEER AND SOPS STONE FLOOR WOOD SIDING WALL DO GAS APPLIANCES AND EQUIPMENT r T-t03 EO3 I STEEL I BEAM ABOVE. MODULAR WANE RACK I STEEL I BEAM ABOVE. REFER TO ID Dxn REFER TO STRUCTURAL TEMP OPERABLE FRAME REFER TO STRUCTURAL DRAWINGS FOR EE INTERIOR STRUCT.STEEL COLUMN. REFER TO STRUCTURAL FOR DIMS AND DETAILS DWGS FOR DETAILS O LESS ETA GLASS DOOR DWGS FOR DETAILS DIMENSI SONS AND W-114 r-itf w I DISPLAY WALL J Z _ - E 02 O O VENDEN�FREETES MFlREPPIRE GAS FIRED FLOOR PLAN NOTES o "B CURITY NL, VEST " KITCHEN B COORDINATE SELECTION WITH Q " B _ VIP GUEST D113 II'D CLG. VAULTED STONE FLOOR PWNER O S 1. GLAZING WITHIN 36 HORIZONTALLY AND 60" VERTICALLY OF SHOWERS/TUBS SHALL BE ------ - --.- ------•--•--•- / 1 STONE FLOOR O-------_. .-_ CAT. II SAFETY GLASS PER 2405.2 FBC. As.oD O SUITE AHu#, 2. GLAZING ON EXT. DOORS AND SIDELIGHTS SHALL BE CAT. II SAFETY GLASS AS PER wooD FLOOR D116 2411.3.1.3. FBC. 0 3. SHOWERS/TUBS SHALL HAVE FLOORS AND WALLS TO 70" OF NON -ABSORBENT MATERIALS VAULTED CLG o� RDa U1XKE110E on2 10 - © SUMMER U r-1041°a`' o KITCHE7AS PER 1204.3 FBC. ----Y FAMILY o °4,WALL HUNG FIXTURES AND CABINETS SHALL BE SUPPORTED AS PER 2510.5 FBC. 20 GA \ - I to STONE FLOOR B AREA o MTL STUDS 0 16" D.C. W/ HORIZ. REINF. LAUNDRY PANTRY I VAULTED CLc STONE FLOOR w ; I T- i w 5, BUILDING SHALL HAVE PRE -CONSTRUCTION TREATMENT PROTECTION AGAINST TERMITES AS WITH EXPOSED VAULTED CLG II STONE FLOOR _____ RAFTERS. T&G oa cJPER 1816.1.7 FBC. t o cLc. E W-6 �D' r 6. MIN. CEILING HEIGHT SHALL BE T-0" AS PER 1203.2.E FBC. i srortFFl look oo o ATH #6 D4 AND RIDGE FL 7. PROVIDE GROUTED CELL OR COLUMN AT BEARING POINT OF EACH GIRDER TRUSS. ; i 11 ° �� 1'\ io"o cL°c. ' __-___- I °a ®" STONE VENEER ANDR�T 8. ALL EGRESS WINDOWS TO COMPLY WITH F.B.C. AN OUTSIDE WINDOW OR DOOR OPERABLE ;' Qo D WOOD SIDING WALL REFER TO ID FROM THE INSIDE WITHOUT THE USE OF TOOLS AND PROVIDING A CLEAR OPENING OF o u c� V Oo DRAWINGS FOR NOT LESS THAN 20" WIDE X 24" HIGH AND 5.7 SQ. FT. THE BOTTOM OF THE OPENING Q i 1 O DIMENSIONS AND W-113 T-113,' DETAILS SHALL NOT BE MORE THAN 44" ABV. THE FLOOR, T-tos w-1as 1 I 2 DD W 9, EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM A Q I --------- THE INSIDE OF THE CLOSET. ;' A o3 A i w 10. EVERY BATHROOM DOOR LATCH SHALL BE DESIGNED TO PERMIT THE OPENING OF THE % II A I ° G E '- - o 05 [ ,il Q FM i LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY. - - " _ il. EVERY SLEEPING ROOM SHALL HAVE AN EMERGENCY ESCAPE AND RESCUE OPENING AT A " MAINE 6 U w-mB Q w-tD7 ISC w-no w-Itt w-t12 LLI MAXIMUM HEIGHT OF 44 TO SILL. FBC R310.1 ALSO READ NOTE #8 THIS SHEET. H.B. 0 01 - +- ; C.U.1 C.U. 2 .U. 3 tos H-B 12. OPERABLE WINDOWS WITH A SILL LESS THAN 36" A.F.F.,WHERE THE FLOOR HAS A DROP T ° - - --- � - - -- ---- -- - -- T-112 � OFF MORE THAN 4'-O", REQUIRE SAFEGUARDS AT NOT LESS THAN 42" IN HEIGHT CL - �� aare DR�YWELL B G (CHECK FOR REQUIRED ESCAPE OPENING DIMENSIONS WHEN THIS CONDITION) FBC TO CA 2411.4.1 f ---- AVERS, DOWNSPOUT. ATE FINAL ZD 13. ALL PRE -FABRICATED BUILDING ELEMENTS TO HAVE ENGINEERED SHOP DWGS, SUBMITTED PAVERS I - COORDINATE '"^- `'� --' LOCATION WITH UW-1 D8 W- N GUTTER COMPANY wI TO THE VILLAGE OF PINECREST BLDG. DEFT. FOR REVIEW AND APPROVAL PRIOR TO -- i TYPICAL FABRICATION & INSTALLATION. I / 1 C D A NOTES TO CONTRACTOR J A6.0 A3.10 A6.00 O z 1. GLAZING IN WINDOWS AND DOORS, FIXED GLASS, ETC. SHALL BE z IMPACT RESISTANT OR COMPLY SFBCR SECTION 4410.4 0 2. IF STORM SHUTTERS ARE USED, THEY SHALL BE APPROVED BY x - PRODUCT CONTROL SECTION AND SHALL BEAR THE NAME OF THE `, BREEZEWAY `, ' \ 1 ` i>... ,, ;,:.._..�, EXPOSED RAFTERS ,.w K- . COMPANY GRAVED IN EVERY SECTION OF THE SYSTEM. (COMPLY WITH T&G;' 19'O, ii. , 11 . y✓-`jti„.., t, §f a SECTION 4410.4 SFBCR - t, COORDINATE COLOR TO MATCH PA�p 3. WHEN OUTLETS ARE IN BACKNA SPLASH, R �7� _ f TYP. '� � �( ,I �% '� n (r ' / FL ORCH _-. - 0 4. ALL CABINET BOXES TO BE CONSTRUCTED OF PLYWOOD. NO PARTICLE �� r x / 3 BOARD CABINET BOXES. B NEW RESIDENCE FOR MR. CESPEDES PARCEL ID 3224-111-0002-000-2 C-24 CANAL RD SAINT LUCIE COUNTY ��j '�; Q_-ay C-A4�-��� l 2.27.17 1701 A REVISIONS _ B PERMIT SET 11, A6.o REVISION 6.6.17 PER BLDG DEPT.COMMENTS 0 REVISION 10.16.17 OWNER REQUESTED REVISION AND CLARIFICATION © REVISION 11.14.17 OWNER REQUESTED REVISION Awl �:. YJ IFS �4� d w A i C" 1 1 ST. FLOOR PLAN W NOTES A2.00 PARTITION LEGEND IIIIIIII TYP, EXTERIOR WALL - 5/8" STUCCO ON 8" CONC. BLOCK U w EXTERIOR SIDE. 5/8" GYP. BD. SMOOTH FINISH ON 1 21•-0" FOIL BACK RIGID INSULATION ON 1" PT WD. FURRING 0 24" _p" 20•_0•• O.C, INTERIOR SIDE, PAINT BOTH SIDES j77��rJ TYPICAL INTERIOR PARTITION WALL - 5/8" GYP. BD. SMOOTH FINISH EACH SIDE ON 3 5/8" METAL STUDS (25 GA. MIN) 0 24" O.C. W/P.T. BOT. PLATE, PAINTED. ? N TYPICAL SOUND PARTITION - n 5/B" GYP. BD. SMOOTH FINISH EACH SIDE ON 3 5/8" METAL STUDS (25 GA. MIN) ® 24" O.C. WITH 3-1/2" BATT INSULATION, W/P T B OT. PLATE PAINTED, TYP. 42" HI. EXTERIOR GUARD WALL - 5/8" STUCCO ON B" CONC. BLOCK, SMOOTH FINISH, PAINT BOTH SIDES. SLOPE CAP TO EXTERIOR Y4". a DENOTES COLUMN WITH CONCRETE BLOCK BASE AND STEEL COLUMN WITH DECORATIVE WRAP t �nM H SYMBOLS LEGEND X NEW DOOR SYMBOL r ® NEW WINDOW SYMBOL N ELEVATION MARK " ' ` PG 4 Pc.i 2 INTERIOR ELEVATION MARK p ELEVATION TARGET O TEMPERED GLASS FRAME -LESS SHOWER ENCLOSURE 0 FIRE PLACE W TV ABOVE. STONE VENEER AND CUSTOM MANTLE. REFER O OR WOOD BURNINGr TO E. COORDINATE FIREPLACE TYPE -GAS VENTLESS d op 24" HT WALL WITH TEMPERED GLASS SHOWER ENCLOSURE ABOVE CI) PROVIDE BLOCKING FOR PLASMA SCREEN TV, & OUTLET & CABLE CONNECTION N w ® 05'-0" A.F.F. COORDINATE LOCATION IN FIELD WITH HOMEOWNER. (N - O ALUMINUM DRYER VENT n OS SUMMER KITCHEN BUILT-IN. STL MT STUDS WITH DURAROCK AND STUCCOS O INSTALLTANKLESS WATERHEATER WITH THERMOSTATIC CONTROL VALVES SWATERAS REQUIRED. Chi TOILET PAPER HOLDER V) TOWEL BAR 3 W BEVELED MIRROR r�i X BUILT-IN WINDOW SEAT WITH STORAGE BELOW. REFER TO LE, L > Y CUSTOM BUILT -OUT CLOSET SYSTEM/SHELVES L Z CUSTOM BUILT-IN. REFER TO INTERIOR ELEVATIONS m AA PERMANENT SCREEN SLIDING DOORS AND PANELS AT PORCH o B TV IN MIRROR 0 BATHROOMS �m N J�� n o^ CC MISTING SYSTEM 0 SUMMER KITCHEN w DD GAS APPLIANCES AND EQUIPMENT n E INTERIOR STRUCT.STEEL COLUMN. REFER TO STRUCTURAL FOR DIMS AND DETAILS 0 Z FLOOR PLAN NOTES B 1, A8.00 GLAZING WITHIN 36" HORIZONTALLY AND 60" VERTICALLY OF SHOWERS/TUBS SHALL BE o CAT. II SAFETY GLASS PER 2405.2 FBC. Q 2. GLAZING ON EXT. DOORS AND SIDELIGHTS SHALL BE CAT. II SAFETY GLASS AS PER 2411.3.1.3. FBC. w i 3. SHOWERS/TUBS SHALL HAVE FLOORS AND WALLS TO 70" OF NON -ABSORBENT MATERIALS oAS PER 1204.3 FBC. 4. WALL HUNG FIXTURES AND CABINETS SHALL BE SUPPORTED AS PER 2510.5 FBC. 20 GA w I STUDS 0 16" O.C. W/ HORIZ. REINF. 'yiI 5. BUILDING SHALL HAVE PRE -CONSTRUCTION TREATMENT PROTECTION AGAINST TERMITES AS >> PER 1816.1.7 FBC. 6. MIN. CEILING HEIGHT SHALL BE 7'-0" AS PER 1203.2.6 FBC. 7. PROVIDE GROUTED CELL OR COLUMN AT BEARING POINT OF EACH GIRDER TRUSS. i B. ALL EGRESS WINDOWS TO COMPLY WITH F.B.C. AN OUTSIDE WINDOW OR DOOR OPERABLE Q FROM THE INSIDE WITHOUT THE USE OF TOOLS AND PROVIDING A CLEAR OPENING OF z NOT LESS THAN 20" WIDE X 24" HIGH AND 5.7 SQ. FT. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" ABV. THE FLOOR. 14 0 9. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM O w THE INSIDE OF THE CLOSET. i 10. EVERY BATHROOM DOOR LATCH SHALL BE DESIGNED TO PERMIT THE OPENING OF THE u' LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY w 11, EVERY SLEEPING ROOM SHALL HAVE AN EMERGENCY ESCAPE AND RESCUE OPENING AT A p MAXIMUM HEIGHT OF 44" TO SILL FBC R310,1 ALSO READ NOTE #8 THIS SHEET. 04 12. OPERABLE WINDOWS WITH A SILL LESS THAN 36" A.F.F.,WHERE THE FLOOR HAS A DROP a OFF MORE THAN 4'-0", REQUIRE SAFEGUARDS AT NOT LESS THAN 42" IN HEIGHT (CHECK FOR REQUIRED ESCAPE OPENING DIMENSIONS WHEN THIS CONDITION) FBC 2--1 2411.4.1 13. ALL PRE -FABRICATED BUILDING ELEMENTS TO HAVE ENGINEERED SHOP DWGS. SUBMITTED 8'-6 TO THE VILLAGE OF PINECREST BLDG. DEPT. FOR RENEW AND APPROVAL PRIOR TO i+ = u FABRICATION & INSTALLATION. Q NOTES TO CONTRACTOR Z 1. GLAZING IN WINDOWS AND DOORS, FIXED GLASS, ETC. SHALL BE o IMPACT RESISTANT OR COMPLY SFBCR SECTION 4410.4 a = 2. IF STORM SHUTTERS ARE USED, THEY SHALL BE APPROVED BY SCALE: 3/16" = V-0" PRODUCT CONTROL SECTION AND SHALL BEAR THE NAME OF THE LID - COMPANY GRAVED IN EVERY SECTION OF THE SYSTEM. (COMPLY WITH SECTION 4410.4 SFBCR 3. WHEN OUTLETS ARE IN BACK -SPLASH, COORDINATE COLOR TO MATCH, 0 TYP. 0 4. ALL CABINET BOXES TO BE CONSTRUCTED OF PLYWOOD. NO PARTICLE T3 BOARD CABINET BOXES. 19 t � l'" C A3.10 � � - 10'-0" 15:_1:, � 29'-10" '-D" 4'-9" 9 -4`V - •• `-�• �, `,�` '� LF N V O L H I T E CT U R E INC. � P w `r )EN/SHOW I8 � , ; 8000 N. FEDERAL HWY. SUITE 1 WJw --- -- a ,JNSU�ATIQN VAL ES I -- --------- '\w 10'-9' ,r i 1 7 BOCA RATON, FL 7 H.B. P. 561 306 4286 F. 561 953 5210 y1. ICENSE # A A 26002586 W.I.0 m E CtyN�C� g�&TERIOR " `, R,ti 4.1 - y ------- ------------ ------ -- -- - - \. -=,�{ C',}vc..-. LDICK WA�.LS JACENT R „s.1" s y ( ALL DESIGNS AND DETAILS INDICATED OR / REPRESENTED BY THIS DRAWING ARE FOR THE USE ON A'.-U(\ 4 °�`... /!. ,R ,.-.....-.. L TRUSSES-- C 7 ING k. � •'�"` .. \,,..,.•.... �, ,�i-19 AND IN cowuNQloR PER THE SPECIFIED ________ ___ ________ ,� 5 ' PROJECT. THIS IS THE PROPERTY OF FINNVOLD - - ARCHITECTURE, INC. AND LL T BE USED li A /,i REPRODUCED WHOLE OR IINAPA TOWITH WITH- f /� T\ j`, , ,/ /X� ?W ! 1\, WRITTEN PERMISSION OR BE LIABLE FOR THE FULLEST OOF G1�G :��G ERA%TTIC 'TCYNE /��` 0 MASTER BA / , 04 API J k T10 / _ EN 6y- - ) r;,, N `.,�. r /' LEGAL RECOURSE. THE CONTRACTOR SHALL VERIFY / I / N � �� LCS - • \�/ r r l ALL EXISTING CONDITIONS AND DIMENSIONS AND p p , NpTIFY THE ARCHITECT OF ANY DISCREPANCIES 10'-8° S'-0' 10 8'-9" MASTER SUITE PRIOR TO THE EXECUTION OF THE WORK _ W , t 6'-4" n � ° I A , / W.I.C. � I `� Y I I t 1 16'-7" 12'-0' I 101 l -------- W. ��- I.C. N .;. ..". ___ _ _I C� I� Ti� N. ..., T•, ,1 A P l ------------- _- STAIRS " 1 4•_0•. `1 -10•• 4'_1" B'-0 1 6'_0•: 5._0" 5._ LIVING ,- ...... / VTRY FOYER / / -� 4._1.: " 5'_0" 1'-0" iB'-11"N I � Al y Y - i I , 6 -4,' 6 -6 21 0 OI 1 i am ; -�./ t� � 1 � �� 1/ I8 10 i � r n fir,/\ 4.j \/ ,\ h �,.�� \\-. A30a" --�, rn II m � ® \: . r' P/z ---------- ---- --------------------- -- - -----------------------------------------_--- ---- ------------------ - NEW RESIDENCE WINE 10'-2° u•-6•' 20--0" FOR MR. CESPEDES 411129O°: PARCEL ID " 3224-111-0002-000-2 C-24 CANAL RD N 7'-0' 16 -11 12 10 - , -- PORCH SAINT LUCIE COUNTY VIP GUEST -' r BATH ® ;; DINING ROOM II � ----------- BAR II WIC I I �n 3-2 -- ° ----- -- -- ------ 1701 _- ------------ 36'-9" m a Q - 10'-1" 1'-5" 3'-4" 1`-9" 4'-10" 4'-11" 4'-9" 5'-10" 3'-10" 24'-10" io 1' 5 - ----------- a B KITCHEN REVISIONS VEST , ' VIP GUEST B PERMIT SET c--�-/ -- SUITE HIM T A6•10 Q REVISION 6.6.17 " 6' 8" 5'-D" tOj „. o SUMMER PER BLDG DEPT.COMMENTS r--------------------------- ----- _� ---- - KITCHEN/BBO I --- FAMILY " °� AREA Q REVISION 10.16.17 --- LA UND Y I PANTRY ^, OWNER REQUEST ED 6-2" 47'_a° 20'-`a" REVISION AND %a H , I � I AT 6 CLARIFICATION r REVISION 11.14.1 7 i o e._a,•_ 10•_6•, 27,_4:• , 0 OWNER REQUESTED Ls �� REVISION t3'-10 t/z" T-10 1/2" '� 2'-0' 7' 6" 9-10a��, 8 I m o A' ; I i 4 C.U.1 C.U.2 Sc .U.3 y� w H.B. DS L a K DRYWELL A TO CA POT O y 8' 6 1 2 5-10 1 2 12•_5" 10'-5" 5..d'r -..". 18'-8" 5'-4" 5'-fi" 8'-0" 5'-6"-0' ,I - 130'-0" 4� NORTH A6. A3.10 A6.00 y�iO 0 ._0 -0 5 -0" 34'-5 1/2" 1._0�1 011 I r r BREEZEWAY ., .. � \1 .,-y�_',:,. '� �'': t `: r r 1ST. FLOOR PLAN W DIMENSIONS o RENTS PARTITION LEGEND TYP. EXTERIOR WALL - 5/8" STUCCO ON B" CONC. BLOCK EXTERIOR SIDE. 5/8" GYP, BD. SMOOTH FINISH ON R-4.1 FOIL BACK RIGID INSULATION ON 1" PT WD. FURRING 0 24" O.C. INTERIOR SIDE, PAINT BOTH SIDES TYPICAL INTERIOR PARTITION WALL - 5/8" GYP. BD. SMOOTH FINISH EACH SIDE ON 3 5/8" METAL STUDS (25 GA. MIN) ® 24" O.C. W/P.T. BOT. PLATE, PAINTED. TYPICAL SOUND PARTITION - 5/8" GYP. BD. SMOOTH FINISH EACH SIDE ON 3 5/8" METAL STUDS (25 GA. MIN) ® 24" O.C. WITH 3-1/2" BATT INSULATION, W/P.T. BOT. PLATE, PAINTED. TYP. 42" HI. EXTERIOR GUARD WALL - 5/8" STUCCO ON 8" CONC. BLOCK, SMOOTH FINISH, PAINT BOTH SIDES. CAP TO EXTERIOR Y4". ❑SLOPE ■ DENOTES COLUMN WITH CONCRETE BLOCK BASE AND STEEL COLUMN WITH DECORATIVE WRAP (TYP). SYMBOLS LEGEND ® NEW DOOR SYMBOL 0 NEW WINDOW SYMBOL ELEVATION MARK t 4 Pa,g 2 INTERIOR ELEVATION MARK 3 Xx- ELEVATION TARGET SECTION MARK KEYNOTES O36" HT, 24" DEEP BASE CABINETS WIDTHS VARY. SEE PLANS BO 36" HT KITCHEN ISLAND/ BAR O24"x48" ATTIC ACCESS W/PULLDOWN LADDER, PROVIDE 100 S.F. AREA OF 5/8' PLYWOOD AROUND ATTIC ACCESS FOR STORAGE SUPPORT DO SINK WITH DISPOSAL EO FULL HT TILE BACKSPLASH, TYPICAL FO TRIMMED OPENING OG 12" DEEP UPPER CABINETS O PRE-FAB WATERPROOFED SHAMPOO CUBBY O 30" H 24" DEEP BASE CABINET - MAKE UP CPUNTER O PROVIDE BLOCKING AS REQUIRED FOR ART WORK OK SHOWER AND TUB AREA TO HAVE FULL HEIGHT TILE SURROUNDS TO CEILING, PROVIDE GREEN BOARD AND RED PAINT WATERPROOF AS REQ'D. O SHOWER BENCH. SIZE VARIES. REFER TO FLOOR PLAN. WATER PROOF AND SLOPE AS REQUIRED. O RECESSED MEDICINE CABINET O TEMPERED GLASS FRAME -LESS SHOWER ENCLOSURE FIRE PLACE W TV ABOVE. STONE VENEER AND CUSTOM MANTLE. REFER O TO IE. COORDINATE FIREPLACE TYPE -GAS VENTLESS OR WOOD BURNING 8 24" HT WALL WITH TEMPERED GLASS SHOWER ENCLOSURE ABOVE Q PROVIDE BLOCKING FOR PLASMA SCREEN TV, & OUTLET & CABLE CONNECTION 05'-0" A.F.F. COORDINATE LOCATION IN FIELD WITH HOMEOWNER. ALUMINUM DRYER VENT 8 SUMMER KITCHEN BUILT-IN. STL MT STUDS WITH DURAROCK AND STUCCO T INSTALL GAS TANKLESS WATER HEATER WITH THERMOSTATIC CONTROL VALVES FOR HOT WATER AS REQUIRED. O TOILET PAPER HOLDER V TOWEL BAR W BEVELED MIRROR X BUILT-IN WINDOW SEAT WITH STORAGE BELOW. REFER TO I.E. O CUSTOM BUILT -OUT CLOSET SYSTEM/SHELVES JE CUSTOM BUILT-IN. REFER TO INTERIOR ELEVATIONS PERMANENT SCREEN SLIDING DOORS AND PANELS AT PORCH TVIN MIRROR 0 BATHROOMS MISTING SYSTEM 0 SUMMER KITCHEN GAS APPLIANCES AND EQUIPMENT INTERIOR STRUCT.STEEL COLUMN. REFER TO STRUCTURAL FOR DIMS AND DETAILS FLOOR PLAN NOTES 1. GLAZING WITHIN 38" HORIZONTALLY AND 60" VERTICALLY OF SHOWERS/TUBS SHALL BE CAT. II SAFETY GLASS PER 2405.2 FBC. 2. GLAZING ON EXT. DOORS AND SIDELIGHTS SHALL BE CAT. II SAFETY GLASS AS PER 2411.3.1.3. FBC. 3. SHOWERS/TUBS SHALL HAVE FLOORS AND WALLS TO 70" OF NON -ABSORBENT MATERIALS AS PER 1204.3 FBC. 4. WALL HUNG FIXTURES AND CABINETS SHALL BE SUPPORTED AS PER 2510.5 FBC. 20 GA MTL STUDS 0 16" O.C. W/ HORIZ. REINF. 5. BUILDING SHALL HAVE PRE -CONSTRUCTION TREATMENT PROTECTION AGAINST TERMITES AS PER 1816.1.7 FM 6. MIN. CEILING HEIGHT SHALL BE 7'-0" AS PER 1203.2.6 FBC. 7. PROVIDE GROUTED CELL OR COLUMN AT BEARING POINT OF EACH GIRDER TRUSS. B. ALL EGRESS WINDOWS TO COMPLY WITH F.B.C. AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS AND PROVIDING A CLEAR OPENING OF NOT LESS THAN 20" WIDE X 24" HIGH AND 5.7 SQ. FT. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" ABV. THE FLOOR. 9. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM THE INSIDE OF THE CLOSET. 10. EVERY BATHROOM DOOR LATCH SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY. 11. EVERY SLEEPING ROOM SHALL HAVE AN EMERGENCY ESCAPE AND RESCUE OPENING AT A MAXIMUM HEIGHT OF 44" TO SILL. FBC R310.1 ALSO READ NOTE #8 THIS SHEET. 12, OPERABLE WINDOWS WITH A SILL LESS THAN 36" A.F.F.,WHERE THE FLOOR HAS A DROP OFF MORE THAN 4'-0", REQUIRE SAFEGUARDS AT NOT LESS THAN 42" IN HEIGHT (CHECK FOR REQUIRED ESCAPE OPENING DIMENSIONS WHEN THIS CONDITION) FBC 2411.4.1 13. ALL PRE -FABRICATED BUILDING ELEMENTS TO HAVE ENGINEERED SHOP DWGS. SUBMITTED TO THE VILLAGE OF PINECREST BLDG. DEPT. FOR REVIEW AND APPROVAL PRIOR TO FABRICATION & INSTALLATION. NOTES TO CONTRACTOR 1. GLAZING IN WINDOWS AND DOORS, FIXED GLASS, ETC. SHALL BE IMPACT RESISTANT OR COMPLY SFBCR SECTION 4410.4 2. IF STORM SHUTTERS ARE USED, THEY SHALL BE APPROVED BY PRODUCT CONTROL SECTION AND SHALL BEAR THE NAME OF THE COMPANY GRAVED IN EVERY SECTION OF THE SYSTEM. (COMPLY WITH SECTION 4410.4 SFBCR 3. WHEN OUTLETS ARE IN BACK -SPLASH, COORDINATE COLOR TO MATCH, TYP. 4. ALL CABINET BOXES TO BE CONSTRUCTED OF PLYWOOD. NO PARTICLE BOARD CABINET BOXES. NORTH 2ND FLOOR PLAN SCALE: 3/16" = 1'-0" DENOTES TRELLIS BELOW ALUMINUM BEDROOM 3 WOOD 36" HEIGHT RAILING TO 42" HEK GUARD F REJECT SPHERE. SHOP DI DENOTES DORMER ABOVE. REFER TO BEDROOM 5 WOOD ALUMINUM 3ATH TILE O a ME O WASH"ER TILE A ROOM 2 0 i I I I C D A6.00 A3.10 J D.) WOOD F.F.E. Bzot BEDROOM 4 WOOD 42" HEIGHT 4%. GUARD RAIUNy TO REJECT A 4"01 SPHERE. WIC 2O I:L1 O 2ND FL LIVING ROOM WOOD SLOPE: 1/4" MIN/FT 42" HEIGHT MIL. GUARD TO REJECT A 4"0 SPHEI 5 53 a a GUTTER AREA CALCULATION LOT AREA = 823,802 S.F. (18.91 Acres) 10 % MAIN HOUSE AC AREA 1ST FL. = 5,507 S.F. AC AREA 2ND FL. = 2,270 S.F. CONDITIONED TOTAL AREA = 7,777 S.F. PORTE COCHERE = 371 S.F. FRONT PORCH = 493 S.F. REAR PORCH = 319 S.F. SUMMER KITCHEN = 1,139 S.F. NON -CONDITIONED AREA 1ST. FL. = 2,322 S.F. COVERED BALCONY = 415 S.F. NON -CONDITIONED AREA 2ND. FL. = 415 S.F. COVERED AREA 1ST. FL. = 7,864 S.F. COVERED AREA 2ND FL. = 3,325 S.F. MAIN HOUSE TOTAL COVERED AREA = 11,189 S.F. CUBIC VOLUME CALCULATION -TOTAL 85129.48 CUBICFT FIRST FLOOR FOYER 8806.5 LIVING ROOM 8318 DINING ROOM 7216 KITCHEN 9014.68 7AW17 Room 7671.8 PANTRY 1010 VESTIBULE 360 LAUNDRY 1859 VIP GUEST ROOM 6286 VIP GUEST BATH 1727 BATH #6 520 MASTER BEDROOM 5060 MASTER WIC 1 3399 MASTER WIC 2 1023 2596 POWDER 450 SECOND FLOOR BEDROOM #2 2089 BATH 2 550 WIC 2 250 BEDROOM #3 2217.6 BATH 3 574. WIC 3 287 BATH 4 574.2 WIC 4 287 2150 A 550 6 290 340 2ND FL LIVING ROOM 3800 ALUMINUM GUTTER ■ 1VOLD £HITECTURE, INC. 8000 N. FEDERAL HWY. SUITE 118 BOCA RATON, FL 33487 P. 561 306 4286 F. 561 953 5210 LICENSE # A A 26002586 ALLDESIGNSAND DETAILS INDICATED OR REPRESENTED BY THIS DRAWING ARE FOR THE USE ON AND IN CONJUNCTION WITH THE SPECIFIED PROJECT. THIS 15 THE PROPERTY OF FINNVOLD ARCHITECTURE, INC. AND SHALL NOT BE USED OR REPRODUCED WHOLE OR IN PART WITH- OUT WRITTEN PERMISSION OR BE LIABLE FOR THE FULLEST LEGAL RECOURSE. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO THE EXECUTION OF THE WORK. NEW RESIDENCE FOR MR. CESPEDES PARCEL ID 3224-111-0002-000-2 C-24 CANAL RD SAINT LUCIE COUNTY 2.27.17 1701 REVISIONS PERMIT SET Q REVISION 6.6.17 PER BLDG DEPT.COMMENTS ® REVISION 10.16.17 OWNER REQUESTED REVISION AND CLARIFICATION A REVISION 11.14.17 OWNER REQUESTED REVISION File Copy CONSULTANTS 2ND FLOOR PLAN W NOTES PARTITION LEGEND 1 o'-D" 57' ■ TYP. EXTERIOR WALL - 5/8" STUCCO ON 8" CONC. BLOCK EXTERIOR SIDE. 5/8" GYP. BD. SMOOTH FINISH ON R-4.1 FOIL BACK RIGID INSULATION ON 1" PT WD. FURRING ® 24" O.C. INTERIOR SIDE, PAINT BOTH SIDES TYPICAL INTERIOR PARTITION WALL - 5/8" GYP. BD. SMOOTH FINISH EACH SIDE ON 3 5/8" METAL STUDS (25 GA. MIN) ® 24" O.C. W/P.T. BOT. PLATE, PAINTED. TYPICAL SOUND PARTITION - 5/8" GYP. BD. SMOOTH FINISH EACH SIDE ON 3 5/8" METAL STUDS (25 GA. MIN) ® 24" O.C. WITH 3-1/2" BATT INSULATION, W/P.T. BOT. PLATE, PAINTED. TYP. 42" HI. EXTERIOR GUARD WALL - 5/8" STUCCO ON 8" CONC. BLOCK, SMOOTH FINISH, PAINT BOTH SIDES, SLOPE CAP TO EXTERIOR Y4". ■ DENOTES COLUMN WITH CONCRETE BLOCK BASE AND STEEL COLUMN WITH DECORATIVE WRAP (TYP). SYMBOLS LEGEND ® NEW DOOR SYMBOL ® NEW WINDOW SYMBOL Pc. ELEVATION MARK 1 4 Pc.g 2 INTERIOR ELEVATION MARK 3 xX ELEVATION TARGET L SECTION MARK KEYNOTES O36" HT, 24" DEEP BASE CABINETS A WIDTHS VARY. SEE PLANS O 36" HT KITCHEN ISLAND/ BAR O24"x48" ATTIC ACCESS W/PULLDOWN LADDER, PROVIDE 100 S.F. AREA OF 5/W PLYWOOD AROUND ATTIC ACCESS FOR STORAGE SUPPORT DO SINK WITH DISPOSAL EO FULL HT TILE BACKSPLASH, TYPICAL FO TRIMMED OPENING 12" DEEP UPPER CABINETS O PRE—FAB WATERPROOFED SHAMPOO CUBBY O 30" H 24" DEEP BASE CABINET — MAKE UP CPUNTER JO PROVIDE BLOCKING AS REQUIRED FOR ART WORK OK SHOWER AND TUB AREA TO HAVE FULL HEIGHT TILE SURROUNDS TO CEILING, PROVIDE GREEN BOARD AND RED PAINT WATERPROOF AS REQ'D. LO SHOWER BENCH. SIZE VARIES. REFER TO FLOOR PLAN. WATER PROOF AND SLOPE AS REQUIRED. O RECESSED MEDICINE CABINET O TEMPERED GLASS FRAME —LESS SHOWER ENCLOSURE O FIRE PLACE W TV ABOVE. STONE VENEER AND CUSTOM MANTLE, REFER O TO IE. COORDINATE FIREPLACE TYPE —GAS VENTL.ESS OR WOOD BURNING 8 24" HT WALL WITH TEMPERED GLASS SHOWER ENCLOSURE ABOVE p PROVIDE BLOCKING FOR PLASMA SCREEN TV, & OUTLET & CABLE CONNECTION 05'-0" A.F.F. COORDINATE LOCATION IN FIELD WITH HOMEOWNER, ® ALUMINUM DRYER VENT O SUMMER KITCHEN BUILT—IN. STL MT STUDS WITH DURAROCK AND STUCCO OINSTALL GAS TANKLESS WATER HEATER WITH THERMOSTATIC CONTROL VALVES FOR HOT WATER AS REQUIRED. O TOILET PAPER HOLDER V TOWEL BAR W BEVELED MIRROR X BUILT—IN WINDOW SEAT WITH STORAGE BELOW. REFER TO I.E. IE CUSTOM BUILT —OUT CLOSET SYSTEM/SHELVES CUSTOM BUILT—IN. REFER TO INTERIOR ELEVATIONS PERMANENT SCREEN SLIDING DOORS AND PANELS AT PORCH TV IN MIRROR ® BATHROOMS MISTING SYSTEM ® SUMMER KITCHEN GAS APPLIANCES AND EQUIPMENT INTERIOR STRUCT.STEEL COLUMN. REFER TO STRUCTURAL FOR DIMS AND DETAILS FLOOR PLAN NOTES 1. GLAZING WITHIN 36" HORIZONTALLY AND 60" VERTICALLY OF SHOWERS/TUBS SHALL BE CAT. II SAFETY GLASS PER 2405.2 FBC. 2. GLAZING ON EKE DOORS AND SIDELIGHTS SHALL BE CAT. II SAFETY GLASS AS PER 2411.3.1.3. FBC. 3. SHOWERS/TUBS SHALL HAVE FLOORS AND WALLS TO 70" OF NON -ABSORBENT MATERIALS AS PER 1204.3 FBC. 4. WALL HUNG FIXTURES AND CABINETS SHALL BE SUPPORTED AS PER 2510.5 FBC. 20 GA MTL STUDS 0 16" O.C. W/ HORIZ, REINF. 5. BUILDING SHALL HAVE PRE -CONSTRUCTION TREATMENT PROTECTION AGAINST TERMITES AS PER 1816.1.7 FBC, 6. MIN, CEILING HEIGHT SHALL BE 7'-0" AS PER 1203.2.6 FBC. 7. PROVIDE GROUTED CELL OR COLUMN AT BEARING POINT OF EACH GIRDER TRUSS. 8. ALL EGRESS WINDOWS TO COMPLY WITH F,B.C. AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS AND PROVIDING A CLEAR OPENING OF NOT LESS THAN 20" WIDE X 24" HIGH AND 5.7 SQ. FT, THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" ABV. THE FLOOR. 9. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM THE INSIDE OF THE CLOSET. 10. EVERY BATHROOM DOOR LATCH SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY. 11. EVERY SLEEPING ROOM SHALL HAVE AN EMERGENCY ESCAPE AND RESCUE OPENING AT A MAXIMUM HEIGHT OF 44" TO SILL FBC R310.1 ALSO READ NOTE #8 THIS SHEET. 12. OPERABLE WINDOWS WITH A SILL LESS THAN 36" A.F.F.,WHERE THE FLOOR HAS A DROP OFF MORE THAN 4'-0", REQUIRE SAFEGUARDS AT NOT LESS THAN 42" IN HEIGHT (CHECK FOR REQUIRED ESCAPE OPENING DIMENSIONS WHEN THIS CONDITION) FBC 2411.4.1 13. ALL PRE -FABRICATED BUILDING ELEMENTS TO HAVE ENGINEERED SHOP DINGS. SUBMITTED TO THE VILLAGE OF PINECREST BLDG. DEPT. FOR REVIEW AND APPROVAL PRIOR TO FABRICATION & INSTALLATION. NOTES TO CONTRACTOR 1. GLAZING IN WINDOWS AND DOORS, FIXED GLASS, ETC. SHALL BE IMPACT RESISTANT OR COMPLY SFBCR SECTION 4410.4 2. IF STORM SHUTTERS ARE USED, THEY SHALL BE APPROVED BY PRODUCT CONTROL SECTION AND SHALL BEAR THE NAME OF THE COMPANY GRAVED IN EVERY SECTION OF THE SYSTEM. (COMPLY WITH SECTION 4410.4 SFBCR 3, WHEN OUTLETS ARE IN BACK -SPLASH, COORDINATE COLOR TO MATCH, TYP. 4. ALL CABINET BOXES TO BE CONSTRUCTED OF PLYWOOD. NO PARTICLE BOARD CABINET BOXES. i I 1 I I I I I —J L_ BEDROOM 14'-8" V-11 BA H 5 o 0 N BATH 0 a m I I I � I BRI GE EO. I1 0 4'-4" „ EQ. ®may 311p]1;7 C Im. a s BEDROOM 4 16'- 5T9 q T1 b—fe7m 17'-9" 2ND FL LIVING ROOM -3" Q �1 N iV a I 0 e N LCO SECOND FLOOR PLAN SCALE: 3/16" = 1'-0" NV�OLD ARCHITECTURE, INC. 8000 N. FEDERAL HWY. SUITE 118 BOCA RATON, FL 3 3 4 8 7 P. 561 306 4286 F. 561 953 5210 LICENSE # A A 26002586 ALL DESIGNS AND DETAILS INDICATED OR REPRESENTED BY THIS DRAWING ARE FOR THE USE ON AND IN CONJUNCTION WITH THE SPECIFIED PROJECT. THIS 13 THE PROPERTY OF FINNVOLD ARCHITECTURE, INC. AND SHALL NOT BE USED OR REPRODUCED WHOLE OR IN PART WITH -OUT WRITTEN PERMISSION OR BE LIABLE FOR THE FULLEST LEGAL RECOURSE. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO THE EXECUTION OF THE WORK. 'M ff NEW RESIDENCE 1 FOR MR. CESPEDES PARCEL ID 3224-111-0002-000-2 I C-24 CANAL RD II I i, SAINT LUCIE COUNTY 2.27.17 1701 REVISIONS PERMIT SET 0 REVISION 6.6.17 PER BLDG DEPT.COMMENTS ® REVISION 10.16.17 OWNER REQUESTED REVISION AND CLARIFICATION © REVISION 11.14.17 OWNER REQUESTED REVISION File COPY CONSULTANTS I 'd A 2ND FLOOR PLAN ■ CEILING NOTES 1. ALL CEILINGS SHALL BE MIN. 5/8" TYPE-X DRYWALL 2. ALL LIGHTS SHOULD BE ON DIMMERS, EXCEPT, CLOSET, LAUNDRY AND EXTERIOR LIGHTS. SEE ELEC. DWGS FOR EXACT PLACEMENT OF DIMMERS. 3. ALL SWITCHES TO BE "DECORA" WHITE PUSH PLATE, SLIDE, OR APPROVED EQUAL. 4. EXISTING CEILINGS TO REMAIN. REMOVE POPCORN CEILING OR REPLACE AS REQUIRED. COORDINATE WITH OWNER. 5. REFER TO ELECTRICAL PLAN FOR NEW LIGHTING. COORDINATE FINAL LOCATION WITH OWNER. 6. CONTRACTOR SHALL PROVIDE DURABLE PLACARD STATING: GENERATOR SEQUENCE OF OPERATION 1. DISCONNECT ALL PANEL BREAKERS EXCEPT: - KITCHEN OUTLETS - KITCHEN LIGHTS - MASTER BEDROOM - REFRIGERATOR 2. AUTOMATICALLY CHANGE TRANSFER SWITCH FROM NORMAL POWER TO GENERATOR UNLESS OTHERWISE NOTED. THIS PLACARD SHALL BE INSTALLED ON GENERATOR AND APPROVED BY BUILDING OFFICIAL. 7.EXHAUST FAN SHOULD BE SILENT TYPE W/TIMER OPERABLE ON MAIN LIGHT SWITCH. FAN TO CONTINUE TO RUN FOR TWO MINUTES AFTER LIGHT IS TURNED OFF. LIGHTING SYMBOL LEGEND FLUORESCENT FIXTURE RECESSED 4" LED HI -HAT �EB EYEBALL FIXTURE/ART LIGHT © M MINI HI HAT W/ LED LAMP YP VAPOR PROOF HI HAT -0- WALL MOUNTED FIXTURE SM SURFACE MOUNTED FIXTURE -� PENDANT MOUNTED FIX URE \�p CHANDELIER J-BOX FOR FAN/ PENDANT/CHANDELIER UNDER CABINET LIGHTING U/C COVE/ROPE LIGHTING {�- EXHAUST FAN/ LIGHT COMBO FLOOD/SECURITY LIGHTS PADDLE FAN 1 GARAGE DOOR OPENER S/C COMBINATION SMOKE DETECTOR CARBON MONOXIDE DETECTOR �F ALL FIXTURES MUST BE UL LISTED ELECTRICAL SYMBOL LEGEND 6 110V RECEPTACLE EXHAUST FAN 6 110V SWITCHED RECEPTACLE TELEPHONE BOARD 4 QUAD-PLEX RECEPTACLE @ THERMOSTAT 6WP WATER PROOF RECEPTACLE El 04 THERMOSTAT W/ REMOTE ALARM TEST STATION 6GFI GROUND FAULT CIRCUIT INTERRUPTER $ SWITCH 220V RECEPTACLE 3 3-WAY SWITCH ® FLOOR RECEPTACLE $4 4-WAY SWITCH 0 JUNCTION BOX DIMMER SWITCH d COLLECTION BOX FOR CONDUCTORS TIME CLOCK ABOVE CEILING - NO ACCESS IS REQUIRED TV CABLE COAX TV OUTLET TELEPHONE/DATA PORT TELEPHONE JACK U.C. UNDER COUNTER --� Q DATA PORT C.M. CEILING MOUNTED 11 A.F.F. ABOVE FINISHED FLyIORII EEL`FUSE DISCONNECT / FRAME SIZE MEMA ENCLOSURE) IF POLES 30 KVA TRANSFORMERI FUSE SIZE ® CEILING MOUNTED --J ELECTRICAL CIRCUIT BREAKER 0 # POLES - BREAKER SIZE (NEMA END) ELECTRICAL METER 0 ELECTRICAL PANEL �^T s CAT 5 COMPUTER CABLE 0 MAIN DISTRIBUTION PANEL NOTE, ALL SYMBOLS MAY NOT BE USED FOR THIS PROJECT ** PROVIDE 3/4"C WITH PULL WIRE. STUB ABOVE CEILING. NOTE RECEPTACLES ARE TO BE MOUNTED AT 15" ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED. SWITCHES ARE TO BE MOUNTED AT 48" ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED. NOTE: ALL HI -HATS LIGHTS PLACED MORE THAN 12'-0" ABOVE FIN FLOOR SHALL HAVE LED TYPE LIGHTING. PRE-FAB TRUSSES 7aLED ROPE/TAPE LIGHTING INVERTED DROPPED CEILING 0 MASTER BATH , AND WIC METAL FRAIMING in CEILING DETAIL "All SCALE: 1-1/2" = 1'-0" 19 J BEDROOM 3 10�o GAG. ,N 1 BATH 3 10'0 CLGI— S) L BATH 4 � 0'0 CLG. 101 %isn WIC 4 J I BEDROOM 4 h 10'0 CLG_ PRE-FAB TRUSSES LED ROPE/TAPE LIGHTING INVERTED DROPPED CEILING O MASTER BATH AND WIC METAL FRAIMING CEILING DETAIL "B" SCALE: 1-1/2" = 1'-0" fvmm DROYWELL METAL FRAMING METAL FRAIMING CEILING DETAIL "C" SCALE: 1-1/2" = 1'-0" INNVOLD ARCHITECTURE, INC. V 8000 N. FEDERAL HVVY. SUITE 118 BOCA RATON, FL 3 3 4 8 7 NORTH P. 561 306 4286 F. 561 953 5210 SECOND REFLECTED CEILING PLAN(]['� LICENSE # A A 26002586 SCALE: 3/16" = 1'-0" DID CROWN MOLDING. PROFILE NTH OWNER B. BOARD OVER 1/2" MTL STUDS. (B" MAX) OR BOXED OUT BEAM PAINT UNDERSIDE EXPOSED CEILING, COORDINATE COLOR WITH OWNER. CEILING DETAIL "D" SCALE: 1-1/2 11 = 1'-Q" ALL DESIGNS AND DETAILS INDICATED OR REPRESENTED BY THIS DRAWING ARE FOR THE USE ON AND IN CONJUNCTION WITH THE SPECIFIED PROJECT. THIS IS THE PROPERTY OF FINNVOLD ARCHITECTURE, INC. AND SHALL NOT BE USED OR REPRODUCED WHOLE OR IN PART WITH- OUT WRITTEN PERMISSION OR BE LIABLE FOR THE FULLEST LEGAL RECOURSE. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO THE EXECUTION OF THE WORK. NEW RESIDENCE FOR MR. CESPEDES PARCEL ID 3224-111-0002-000-2 C-24 CANAL RD SAINT LUCIE COUNTY 2.27.17 1701 REVISIONS PERMIT SET A REVISION 6.6.17 PER BLDG DEPT.COMMENTS Q REVISION 10.16.17 OWNER REQUESTED REVISION AND CLARIFICATION Q REVISION 11.14.17 OWNER REQUESTED REVISION CONSULTANTS File C v 2ND FLOOR REFLECTED CEILING PLAN 1-A217 ■ +32'-5" -----JOPQF1tIDGE-------------------------------.------------- -- --------- EXTERIOR ELEVATIONS "ri< SCALE: 3/16" = l'-0" .-,�I2ND FL TOP OF TB MEN 111�l11'I1111 .• • 4il• _ ai II (Top ropon OF TB) NUNN— rlr�r� li■i1 WEST ELEVATION SCALE: 3/16" = 1'-0" r .I� .11■I■�7 DENOTES STANDING SEAM METAL ROOF IONZE FINISH (TYP) ® ❑ r III 1= v ong 111 DENOTES STANDING SEAM METAL ROOF FINNVOLD ARCHITECTURE, INC. BRONZE FINISH (TYP) 8000 N. FEDERAL 33 SUITE 118 BOC BOCA RATON, FL 3 3 4 8 7 P. 561 306 4286 F. 561 953 5210 LICENSE # A A 26002586 _DOOR NOTE: __________ _ ** IT IS THE RESPONSIBILITY OF THE DOOR SUPPLIER TO COORDINATE ALL REQUIRED OPENINGS WITH THE CONTRACTOR PRIOR TO ANY WORK, THE DOOR SUPPLIER IS RESPONSIBLE FOR CODE COMPLIANCE OF HIS PRODUCTS. ALL SLIDING GLASS DOORS SHALL HAVE BRONZE ESP FINISH ----------_---------- DENOTES STANDING SEAM METAL ROOF � DENOTES STONE VENEER BRONZE FINISH (TYP) I (TYPICAL) W-204 DENOTES SMOOTH STUCCO AND (CAST) STONE LEDGE HEADER (CAST) IM-3 ■ DECORATIVE_ — — — --- — — — — DENOTES STONE — _ — —DENOTES BRACKETS HEAOER(TYPICAL) == d DENOTES STEEL COLUMN - - ` DENOTES STONE SILL WITH DECORATIVE WRAP _. . ,.. (TYPICAL) AND CONIC BASE WITH yr T STONE VENEER (TYPICAL) DENOTES STONE VENEER DENOTES STONE VENEER . T-104 1-.105 (TYPICAL) (TYPICAL) W 104 W-1p5 WES-T-ELEVATION- — — — — - ---- ---- -- --------------------------------------------------- A 4✓ SCALE: 3/16" = 1'-0" 12 i I. +32'-5" — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -- V Top -. DEN07ES FIRE PLACE NEW STANDING SEAM METAL ROOF. BRONZE FIMSH 427 HEIGHT MTL GUARD RAILING TO '* REECT A 00 SPHERE. ALLDESIGNSAND DETAILS INDICATED OR REPRESENTED BY THIS DRAWING ARE FOR THE USE ON AND IN CONJUNCTION WITH THE SPECIFIED PROJECT. THIS IS THE PROPERTY OF FINNVOLD ARCHITECTURE, INC AND SHALL NOT BE USED OR REPRODUCED WHOLE OR IN PART WITH OUT WRITTEN PERMISSION OR BE LIABLE FOR THE FULLEST LEGAL RECOURSE. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO THE EXECUTION OF THE WORK. NEW RESIDENCE FOR MR. CESPEDES PARCEL ID 3224-111-0002-000-2 C-24 CANAL RD SAINT LUCIE COUNTY 2.27.17 1701 REVISIONS PERMIT SET Zt REVISION 6.6.17 PER BLDG'DEPT.COMMENTS 0 REVISION 10.16.17 OWNER REQUESTED REVISION AND CLARIFICATION © REVISION 11.14.17 OWNER REQUESTED REVISION CONSULTANTS Copy )� 1 _s 1, T O EVATIONS F_ — — — — — — — — — — — — — — — — EXTERIOR ELEVATIONS SCALE: 3/16" = 1'-0" I I 111 42" HIGH RAILING TO REJECT 4" SPHERE AND HALF PARTITION --J9.'L OE.HM----- — — — — — --- — — — — — - — — — — — — — — _ — — — — — — — — — — --- —`--' — — --- -o I --TOP OF BM -------------------------,.--- �. — — +/-0'-0" (+25.5'NGVDO — lulul ------4 TOP OF3RIDGE---------------- ------------------------ y DENOTES SMOOTH I g ; _ STUCCO AND (CAST) STONE LEDGE HEADER DOOR NOTE: ** IT IS THE RESPONSIBILITY OF THE DOOR SUPPLIER TO COORDINATE ALL REQUIRED OPENINGS WITH THE CONTRACTOR PRIOR TO ANY WORK, THE DOOR SUPPLIER IS RESPONSIBLE FOR CODE COMPLIANCE OF HIS PRODUCTS. ALL SLIDING GLASS DOORS SHALL HAVE BRON7E ESP FINISH. tl �� DENOTES STONE VENEER (TYPICAL) DENOTES CAST DSTONE --- ------ -- —-------------- - - DENOTES DEORATIVE - - SHUTTER DENOTES STANDING m — SEAM METAL ROOF w-stt m -- W-213 W-214 II I I I ------------- —�—"—° I: � � 1L- , ng , TOP OF BM — — — — ---- I' --------------------- — �POBT�OCHERE — — — — ._ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — i -------------- $TOP —0" _. —------------------ TOP OF BM gs m, I STEEL COLUMN WITH INN � �_®z= I DENOTES �1� l �m ■ FINNVOLD ARCHITECTURE, INC. C NORTH ELEVATION O SCALE: 3/16 = 1 -0 NEW STANDING SEAM METAL —BRONZE ROOF. BRONZE FINISH _-------------------------------- --- I. +32'-5"---------------- _-------------- --_.— TOP OF RIDGE _ NEW STANDING SEAM METAL ROOF. BRONZE FINISH - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- ---- - - - - - - - - - - - - - - - - - - - - - - - - - — ------------------- NEW STANDING SEMI METAL ROOF. .. BRONZE FINISH DENOTES STONE — VENEER VENE (TYPICAL) 1I I. � I; DENOTES STONE VENEER IIR,I - 1 I� pgpyp ICI I , II 12 (TYPICAL) I II � I MM ipt qJ D SOUTH ELEVATION OSCALE: 3/16" = 1'-0" 2 + -----------------------------------------� 12 4 ,u w 2os kt+ 12 I 12 16'-0• T.O.TIE BM 0 I � I � E BATTING CAGE Y la I I 15'-0" T.O.TIE BM _—_—_—_ —_ —_ -- _ --_ —— — —— — —— — — — — _5TBY_9TB.U.CTUB __ _ _ ___ ___ ___ ___ ___ -� _ — — — — _ — — — — — — — — — — — — — — — — — — — —— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —._.— ._ — _. ..� _. — — — — — — — — — — — — — — — — — — — — - ---------------- — : : : _.. - 10'-6" TDB -- + m ` w +/-0'-0" (+25.5'NAVD}�---------------------------_----------------------------------------------------------------------------------------------- ------ — +/-0'-0" (+25.5'NAVD% — _—. vvFFFl g EAST ELEVATION OSCALE: 3/16" = 1'-0" 8000 N. FEDERAL HWY. SUITE 118 BOCA RATON, FL 3 3 4 8 7 P. 561 306 4286 F. 561 953 5210 LICENSE # A A 26002586 ALL DESIGNS AND DETAILS INDICATED OR REPRESENTED BY THIS DRAWING ARE FOR THE USE ON AND IN CONJUNCTION WITH THE SPECIFIED PROJECT. THIS IS THE PROPERTY OF FINNVOLD ARCHITECTURE, INC. AND SHALL NOT BE USED OR REPRODUCED WHOLE OR IN PART WITH- OUT WRITTEN PERMISSION OR BE LIABLE FOR THE FULLEST LEGAL RECOURSE. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO THE EXECUTION OF THE WORK. NEW RESIDENCE FOR MR. CESPEDES PARCEL ID 3224-111-0002-000-2 C-24 CANAL RD SAINT LUCIE COUNTY 2.27.17 1701 REVISIONS PERMIT SET 0 REVISION 6.6.17 PER BLDG DEPT.COMMENTS 0 REVISION 10.16.17 OWNER REQUESTED REVISION AND CLARIFICATION 0 REVISION 11.14.17 OWNER REQUESTED REVISION CONSULTANTS NS I 4" GALVANIZED METAL EXHAUST DUC TO TERMINATE THROUGH ROOF OR EAVE. SEE DETAIL M-3 I I I I I I I I I I I I I I I I I I I I I r------------------------------ I I ----------------------------- I I I I I I I I I I COV. ENTRY I I I I I I I I I I I I I I I I I I I I _______________________________ ___ L_J - - - - - - - - - - - - - - - - - -._ - - - - - _ _ _ _ i _ _ _Tr _ I I I I I 4" GALVANIZED METAL EXHAUST DUCT TO TERMINATE --4HR0U GH--ROBF-OR_- EAVE. SEE DETAIL M-3 7/8" FRIGERANT LII 3/9"j2ESUCTION LINE O M R �TH I I II 11100 c s° II %V FOYER -- 4" GALVANIZED METAL EXHAUST DUCT TO TERMINATE THROUGH ROOF OR EAVE. SEE DETAIL VIP GUEST IIIIIII ._ tranfer 4r� VIP GUEST �UITE I.RI9 I � I / \ a M / I CONDENSATE DRYWELL PER DETAIL M-3 CL m C zoXzo tranfer m r------------------- I I I I � I I MASTER SUITE ® I I I I I I I I I I I I I I I I I� I I Y�llW I 14x14 tranfer — J ------- I I I I 100 I I I I I LIVING I I I I I I I I I I I I I I I I I I I a I I I I I CONNECT TO CONDENSATE DRYWELL PER II DETAIL M-3 I I 3/4" PVC CONDENSATE DRAIN LINE II I I s"a II I 50c DINING ROOM x1 I I 100cf 1 I I 8"a BAF 11 125cf 9� 30s18 I ra ' CAI �- 16 r- T I � I Pill i I 11 NEW 59" X 25" FIXED GLASS 6"d 00 CF REMOVED 16'X 10' SLIDER �/� N9" X 25" FIXED 1 GLASS l21 / NEW "X10' FIXED GLASS 0 1R GENERAL MECHANICAL NOTES 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF A COMPLETE SYSTEM IN ACCORDANCE WITH THESE DRAWINGS, THE APPLICABLE BUILDING CODE AND ALL OTHER APPLICABLE STATE, COUNTY AND LOCALORDINANCES AND THE LATEST ADDITION OF THE FOLLOWING PUBLICATIONS; SMACNA, ASHRAE, NFPA 90A, 90B, 91 & ANSI B-9.1 MECHANICAL REFRIGERATION. ALL DUCTWORK SHALL BE FABRICATED, INSTALLED AND SUPPORTED AS PER SMACNA STANDARDS. 2. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK. 3. THE CONTRACTOR SHALL VISIT THE SITE AND COORDINATE WORK WITH OTHER TRADES. TO INSURE AN ORDERLY PROGRESS OF THIS WORK. 4, ALL MATERIAL SHALL BE NEW OF GOOD QUALITY. ALL WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SKILLED WORKMAN. 5. ALL NON —EXPOSED SUPPLY AND RETURN AIR DUCTWORK SHALL BEMINIMUM R-6 FIELD FABRICATED FIBERBOARD DUCT OR INSULATED ROUND SPIRAL DUCT AS SHOWN. 6. ALL EXHAUST DUCTS AND OUTSIDE AIR DUCTS SHALL BE GALVANIZED SHEET METAL WITH SEALED SEAMS AND JOINTS. 7. DUCT SIZES SHOWN ARE INSIDE DIMENSIONS. 8. ALL AIR DEVICES (DIFFUSERS, REGISTERS AND GRILLES) SHALL BE ALL ALUMINUM CONSTRUCTION WITH EXPOSED SURFACE OFF WHITE BAKED ENAMEL FINISH OR AS SPECIFIED BY ARCHITECT. DEVICES SHALL BE TITUS, METALAIRE, AIRGUIDE. PROVIDE OPPOSED BLADE DAMPERS AT ALL DIFFUSERS AND REGISTERS. 9. THERMOSTAT SHALL BE COMBINATION COOLING/HEATING, WITH SYSTEM "COOL —AUTO —HEAT —OFF" AND FAN "ON —AUTO" SELECTOR SWITCHES. PROVIDE PROGRAMMABLE TYPE THERMOSTAT. " CONTRACTOR SHALL FULLY INSTRUCT OWNER ON HOW TO PROPERLY PROGRAM INSTALLED THERMOSTATS. t PROGRAMMABLE THERMOSTAT SHALL BE BY MANUFACTURER OF INSTALLED AIR HANDLING UNIT. IT IS RECOMMENDED THAT DURING OCCUPIED HOURS, THE FANS BE SET TO "ON" IN LIEU OF "AUTO". 10. PROVIDE NEW FILTERS FOR ALL AIR CONDITIONING EQUIPMENT BEFORE STARTING THEM. REPLACE THEM PRIOR TO FINAL ACCEPTANCE BY OWNER. 11. MECHANICAL PLANS IN GENERAL, ARE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ IN CONJUNCTION WITH ARCH. PLUMBING, ELECTRICAL AND STRUCTURAL PLANS AND SHALL BE CONSIDERED AS ONE SET OF DOCUMENTS. DUCT AND PIPING OFFSETS, BENDS AND TRANSITIONS WILL BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE FUNCTIONAL SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 12. CONTRACTOR SHALL INSTALL ALL OUTDOOR EQUIPMENT TO WITHSTAND WIND LOADING FORCES AS REQUIRED BY LOCAL CODES. REFER TO STRUCTURAL PLANS BY OTHERS FOR STRUCTURAL DETAILS. 13. PROVIDE ALL NECESSARY CONTRACTORS, RELAYS, ETC., FOR A COMPLETE OPERATING A/C UNIT 14. IF ANY ERRORS, DISCREPANCIES OR OMISSIONS APPEAR IN THE DRAWINGS, SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING OF SUCH ERROR OR OMISSION. IN THE EVENT OF THE CONTRACTOR FAILING TO GIVE SUCH NOTICE BEFORE CONSTRUCTION AND/OR FABRICATION OF THE WORK, HE WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS, DISCREPANCIES OR OMISSIONS AND THE COST OF RECTIFYING SAME. PORCH 0p WW9 8"d 150cf 125cf 125cf KITCHE FAM I LY e°a -------- - --- O------------------------------- JL ° luau 150cf 1L 12x12 GRILL TO SOFFIT W/ AUTO DAMPER MECHANICAL PLAN me = r-o• \ ------------- 4- I I I I I I I I I I I / I I / \.\ SU"ER \\KITCHEN/BBQ �REA I o I File Copy REVISIONS BY OWNER CHANGE 10-24-17 Q OWNER CHANGE 10-24-17 © AS BUILTS 2-20-18 00 I� N d- r� I w a z O X O J Lm J a in w IR¢0Nw _ � u7 Q U (/] J Ld o W EL DRAWN BY: CAFWS VRACA 1000 S DIXIE HWY. WEST POMPANO BEACH FLA. 33060 PHONE:561- 445- 9661 EMAIL: car1oav11aca2®GmaII.cam DATE 1+17 SCALE: 146'=r-w PROJECT: NOR'OR%-CFSPMffl UEIAIL M—G 3/4" PVC CONDENSATE MECHANICAL PLAN me = r-T SPIT SYSTEM - AIR HANDLING UNIT AIR CONDITIONING EQUIPMENT SCHEDULE z UNIT TAG MANUFACTURER & MODEL # TONS CFM KW HEAT 0 H Z 2 _ 0 AHU-1 RHEEM OR EQUAL RCF-4821JA 4.0 1,600 10 KW HEAT PUMP a AHU-2 RHEEM OR EQUAL RCF-4821JA 4.0 1,600 10 KW HEAT PUMP AHU-3 RHEEM OR EQUAL RCF-6021JA 5.0 2,000 1OKW HEAT PUMP AHU-4 RHEEM OR EQUAL RCF-2421JA 2.0 800 5KW HEAT PUMP AHU-5 RHEEM OR EQUAL RCF-3621JA 3.0 1200 7.5 KW HEAT PUMP SPIT SYSTEM - CONDENSING UNIT AIR CONDITIONING EQUIPMENT SCHEDULE z� UNIT TAG MANUFACTURER &MODEL # TONS CFM SEER Z= ACU-1 RHEEM OR EQUAL RP1748AJ 4,0 1,600 17 0 U ACU-2 RHEEM OR EQUAL RP1748AJ 4,0 1,600 17 ACU-3 RHEEM OR EQUAL RP1760AJ 5.0 2,000 17 ACU-4 RHEEM OR EQUAL RP1724AJ 2,0 800 17 ACU-5 RHEEM OR EQUAL RP1736AJ 3.0 1200 17 File Copy REVISIONS BY CO 6-2H1 AS BUILTS 2-20-18 DRAWN BY: CARLOS VnACA POMPANOXBEACHYFLWEST 33060 PHONE:561- 445- 9661 EMAIL, carloaviloca200mall,com DATE 3-1-17 SCALE: Y16' = P-0" PROJECT : NOMFE-CE MES E�ETl1�l SCREW FASTENERS IN DUCTS S" DIA. OR LAR3ER SCALE: N.T.S. 51RANCN T,4<E -OFF 4 D�41"Ii�ER ASS'I"• EXTERNAL POSITION INDICATOR AND OPERATOR NOTE; ALL DUCTWORK IN UNCONDITIONED AREAS TO HAVE MIN, R=6 INSULATION I" INSULATED �L-LAY-IN CEIL'G SCALE. N.T.S. INSULATED FLEX DUCT <SEE PLAN FOR SIZE) -DRAW RAND TOUND RAP EGG CRATE V SUPPLY AIR LIQUID & SUCTION LINES OVERHEAD RISE IN o AHU CLOSET WITH INSULATION AS PER FBCM 2007 EDITION, DROP IN GWB CHASE . FIRE CAULK EXTERIOR WALL OPENINGS. SIZE VARIES, SEE PLAN. 4" CLEAR ON ALL SIDES OF UNIT AIR HANDLER ADJUSTABLE AIR HANDLER UNIT METAL BASE WITH DISPOSABLE INTERNAL FILTER SD CONDENSATE DRAIN AUX, DRAIN PAN. 1 1 2" DEEP LINE THRU X 1" LARGER THAN UNIT IN CONDENSATE PUMP LENGHT AND WIDTH. TO RAISE ABOVE FLOAT SWITCH IN PAN CEILING LEVEL. SLOPE TO DRAIN THUMB SCREWS THRU EXTERIOR RETURN WALL INTO AIR RUBBER MOUNTS CONDENSATE PIT VERTICAL AIR HANDLER APPLY "HAROCAST" SEALER STRIPS TO SPIN -IN FITTING (TYR) SUPPLY pUCT MANUAL VOLUME DAMPER CLAMP o EACH END OF FLEXIBLE DUCT ATTACH TO STRUCTURE W/BOLTED CONN. 2" FORMED SHEET METAL BAND CLAMP FLEXIBLE DUCT iCEILING GRID =)Ir=r=L4>EfRI N ®Ufi 1� fi41 SCALE. N.T.S. 2"x3/411 2® a. SUPPORT CHANNEL"OR FAN. ATTACH TO CEILINGSUPPORT GRID. (2 REQUIRED) SEAL AROUND OPEN CEILING EXHAUST GRIL SCALE: N.T.S EXHAUST FAN - SEE DRAUJING FOR DUCT SIZE NQTE, ALL HANGING STRAPS SHALL BE A MINIMUM OF 1-1/2 WIDE 26 GA, GALVINIZED STEEL CONSTRUCTION WITH A 9 FT. MAXIMUM SPACING 4LL CAP kULK ALL AROUND METHODS OF HANGING DUCTS CONTROL DAMPER 456 5140ETAP W/ TRANSITION TO ROUND. INSULATE I I I I I I I I I I I I I I f I I I I I I AIRFLOLU I I I I I PROVIDE STEEL SLEEVE AT PENETRATION AND SEAL ENDS WATERTIGHT PROTECT REFRIGERANT LINES UP ALONG WALL WITH LINE COVER AND PAINTED TO MA I CH ARCH I I=C I URI= LINE COVER SHALL BE 22 GA. SHEET METAL WEATHERPROOF FASTEN TO WALL WITH 1/8'41 CONCRETE NAIL WASHER (2)Ys' PLASTIC COATED STEEL CABLE SECURE TO SLAB W/ 5,5. TURNBUCKLES. CONDENSING UNIT PER FBCM 301. 12 WIND LOAD. I FBCB 130-1 . I, 1620, A5CE7-10 SECURE CONDENSING UNIT TO CONCRETE PAD WITH I' WIDE GALVANIZED SHEETMETAL STRAPS RATED FOR 170+ MPH HURRICANE FORCE WINpS (TYPICAL.) FIN. SLAB ELEV. = 40'-0' ELEV. 7. ( 0' N.VfSD. PROVIDE 3/4' LAG -BOLT TO TIE DOWN CONDENSING UNIT t0 SLAB (TYPICAL OF 4) FIBERGLASS OR STEEL SUPPLY DUCT APPLY SPIN -IN FITTING W/ VOLUME CONTROL DAMPER (INSULATE) CONTROL DAMPER INSULATED FLEXIBLE DUCT RUN (TYP.) 5TAIINLE55 STEEL DRAUJ BAND CONICAL BELLMOUTH FITTING FITTING FLEX. MASTER SERIES 4000 MODEL DC-0 CONCRETE BLOCK FILL SLEEVE WITH 51LIC SEALANT FOAM CTG FR n >3 KEEP REFRIGERANT L I HIGH AND TIE TO TRU5 MEMBERS STEEL U BAR IMBEADE THE CONCRETE. -NEOPRENE VIBRATION ISOLATORS CONCRETE HOUSEKEEPING PAD CONDENSING UNIT MOUNTING DETAIL NTS BAC PVC SCHED 40 CONDENSATE A 121DIAM xIB'DEEP E, FILLED V/GRAVEL IED, FOR (PREFAB 5GAL MIN DRYV IVIED EQUAL GALVANIZED EXAUST ROOF CAP W/BACKDRAFT DAMPER SLOPED ROOF CAP. WIRE MESH SCREEN INSTALLED SLOPED 2x4 WOOD BLOCKING 4' GALV. METAL DUCT 26 GA. BACKDRAFT D PER NUTONE EXH. FAN — CEILING GRILLE SIZE AS PER k,AIR MFR, SPEC'S �V-I A l l CT 7 A NI nE_TA I I N.T.S. DRY WELL DETAIL File Copy 4� 1 MECHANICAL DETAILS lwlul` REVISIONS BY AS BUILTS 2-20-18 �D-rRAWWNM BYE : 1000 S D�IX`IE HWY.V�J CA POMPANO BEACH FLA. 33060 PHONE:561- 445- 9661 EMAIL carloevllaca203moll.com DATE 3-1-17 SCALE: 3/16' - Nr PROJECT NOTORLS-CESPEDES TO POOL PAVILION SEPTIC REVISIONS BY © AS BUILTS 2-20-18 DRAWN BY: CARLOS VIIACA POMPANOXBEACH FLA. 33060 PHONE:561- 445- 9661 EMAIL: corlo vlacaMmall.com DATE 3-1-1% SCALE: 3/16' = r-W PROJECT : NOMPE-CE MES PLUMBING PLAN wo - r-v WATER & SANITARY PIPING MATERIAL MATERIAL NOTE: WATER SERVICE PIPING CHLORINATED POLYVINYL CHLORIDE (CPVC) PER FBC 2010 TABLE 605.3 WATER DISTRIBUTION PIPING COPPER PER FBC 2010 TABLE 605.4 SANITARY & VENT PIPES POLYVINYL CHLORIDE (PVC) PER FBC 2010 TABLE 702.1 TABLE 702.2, TABLE 702.3, TABLE 702.4 CERAMIC TILE BOND COAT REINFORCED WALL MORTAR BED OLID BACKING 0 CERAMIC TILE INTEGRATED DRAIN BONDED FLANGE SHOWER PAN LINER CRUSHED TILE SLOPED REINFORCED FLOOR OR STONE AROUND MORTAR BED 1"-1 3/4' THICK WEEP HOLES SHOWER DETAIL N.T.S. TILE REOI our. k, WATER SIZE LINE FOR THE WHOLE HOUSE INCLUDING THE ADDITIONAL FIXTURES IS REQUIRED TO BE 1" FIXTURE CONNECTION SCHEDULE FIXTURE TYPE C.W. CONN. H.W. CONN. TRAP SIZE F.U. COUNT FLOW RATE REMARKS WATER CLOSET 1/2" - 3" 3.0 GPM LAVATORY 1/2" 1/2" 1-1/4" 2.0 GPM BATHTUB 1/2" 1/2" 1-1/2" 4.0 GPM SHOWER 1/2" 1/2" 1-1/2" 3.0 GPM SINK 1/2" 1/2" 1-1/4" 2.0 GPM WASHER 1/2" 1/2" 1-1/2" 2.5 GPM DISHWASHER 1/2" 1/2" — — VACUUM BREAKER & ALVE IN THE VERTICAL NOTE: PLUMBING FIXTURES, FAUCETS AND FIXTURE FITTINGS TO COMPLY WITH REFERENCED STANDARD AS PER FBC TABLE P2701.1. tile in bath and shower should be brought up to the levels shown A SKIM COAT OF ADHESIVE COMPLYING WITH ANSI A 136.1, AMERICAN NATIONAL STANDARD FOR ORGANIC ADHESIVES FOR INSTALLATION OF CERAMIC TILE, TYPE I OR TYPE II, SHALL BE APPLIED OVER ALL SURFACES THAT HAVE BEEN FINISHED WITH JOINT COMPOUND AND ALLOWED TO CURE BEFORE THE APPUCATION OF TILE BEGINS. CUT EDGES AND OPENINGS AROUND PIPES AND FIXTURES SHALL BE CAULKED FLUSH WITH WATERPROOF, FLEXIBLE SEALANT OR ADHESIVE COMPLYING WITH ANSI A 136.1, AMERICAN NATIONAL STANDARD FOR ORGANIC ADHESIVES FOR INSTALLATION OF CERAMIC TILE, TYPE I OR TYPE II. THE TILE, WALL PANEL, OR OTHER SURFACING MATERIAL MANUFACTURER'S SPECIFICATIONS SHALL BE FOLLOWED, TILE OR WALL PANELS SHALL BE APPLIED DOWN TO THE TOP SURFACE OR EDGE OF THE FINISHED SHOWER FLOOR, RETURN, OR TUB AND SHALL OVERLAP THE TOP LIP OF THE RECEPTOR, SUB —PAN, OR TUB AND SHALL COMPLETELY COVER THE AREAS SPECIFIED IN SECTIONS A.1.2.3 (a) through A.1.2.3(e). (see figure) (a) TUBS WITHOUT SHOWERHEADS — SURFACING MATERIAL SHALL EXTEND NOT LESS THAN 6 IN ABOVE THE RIM OF THE TUB. (b) TUBS WITH SHOWERHEADS — SURFACING MATERIAL SHALL File COPY EXTEND NOT LESS THAN 5 FT ABOVE THE RIM OF THE TUB OR 6 IN. ABOVE THE HEIGHT OF THE SHOWERHEAD, WHICHEVER IS HIGHER. SURFACING MATE%Y� HiyEXT60' ,trL (c) SHOWER STALLS— Not IES$.i THAN 6 FT. ABOVE THE SHOWER DANt ON` IN AB*jHEj T4 OF THE SHOWERHEAD, WHICHEVER IS IGH Ntp',� 1 (d) GYPSUM BOARD WINDOW SILLS AND InT�W{ R ti 1 TUB ENCLOSURES SHALL BE COVERED ST'0 LbGHT i� L* r {) ¢r .� THAN AS SPECIM,FED FOR THE WALL : Kw 1 ,. i L11 r (a) SURFACING MATERIAL SHALL BE APLL SPECIFIED HOGHT F OR A OF LESS TAN 4 IN. (100 mm) CORNERNOT BEYOND AN OUTSDENCE NTS BEARE EXCLUDED. REVISIONS BY AS BUILTS 2-20-1 CAM OS DRAWN �� BY: W AAA 1000 S DIXIE HWY. WEST POMPANO BEACH FLA. 33060 PHONE:561- 445- 9661 EMAIL, canoe AIaca2®Gmail.00m DATE 1+17 SCALE: '�r�Lu ��w J/ iV 6 1s V PROJECT : NOMPE-CE MDES 5 ELECTRICAL PLAN -me = mr INSTALL ALL ELECTRICAL WIRING AND COPONENTS AS PER PLAN. ARC FAULT INTERRUPT TYPE OUTLETS SHALL BE INSTALLED IN ALL BEDROOMS . SMOKE DETECTORS THAT ARE HARD WIRED, INTERCONNECTED AND HAVE A BATTERY BACKUP ARE 70 BE INSTALLED IN ALL BEDROOMS AND A COMBINATION SMOKE/C 70 BE INSTALLED WW14N 10' OF SLEEPING AREAS GFT RECEPAQfS ARE TO BE INSTALLED IN KITCHEN AND ALL BATHROOMS. ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION CLG. MOUNTED LIGHT 46� SECURITY SPOT LIGHTS WALL MOUNTED LIGHT .4 TELEPHONE JACK SWITCH I[}v + TELEVISION / INTERNET SWITCH 3 WAY L_T SMOKE DETECTOR RECEPTACLE CARBON MONOXIDE DETECTOR GROUND FAULT INDIC EXHAUST FAN UNDER COUNTER LIGHT LED HI —HAT CAMERA ® LED HI —HAT (MINI) 220 VOLT RECEPTACLE ELECTRICAL METER ELECTRICAL PANEL DISCONNECT ® SPECIAL RECEPTACLE p PENDANT LIGHT ELECTRICAL NOTES: 1 OFTH EN.E.C. 2011RK AND LOCAL GOVERNING THE REVISION 2. ALL WIRING TO BE COPPER UNLESS OTHERWISE NOTED. 3. ALL MATERIALS, WHERE APPLICABLE, SHALL BE U.L. LABELED 4. ALL OPENINGS REQUIRED BY ELECTRICAL CONTRACTOR TO BE CLOSED TO MATCH FINISH AND FIRE RATED BY ELECTRICAL CONTRACTOR. 5. INSTALLATION HEIGHTS ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED: WALL HUNG TELEPHONE 56" A.F.F. TELEPHONE JACKS 12" A.F.F. LIGHT SWITCHES 48" A.F.F. RECEPTACLES 12" A.F.F. TELEVISION JACKS 12" A.F.F. 6, CO-ORDINATE ALL CONDUIT RUNS AND EQUIPMENT INSTALLATION WITH OTHER TRADES TO AVOID CONFLICTS PRIOR TO FABRICATION, INSTALLATION AND ERECTION. 7. ELECTRICAL CONTRACTOR TO VERIFY ALL HVAC UNIT CONNECTIONS WITH HVAC CONTRACTOR PRIOR TO INSTALLATION. 6. ALL METERS, METER CENTERS AND DISCONNECTS TO BE APPROVED BY FLORIDA POWER AND LIGHT. 9. LOCATION OF ELEC. REC. SHALL COMPLY W/ NEC-210-52 AND RECEPTACLE SPACING SHALL COMPLY WITH NEC 210-72. LIGHTING OUTLETS SHALL COMPLY WITH NEC-210-8 10. ALL NEW CIRCUITS TO BE ARC FAULT PROTECTED NEC 2008 210.12 11. ALL NEW RECEPTICLES TO BE TAMPER RESISTANT NEC 406.11 File Copy ggfa p REVISIONS BY Q OWNER CHANGE 10-24-17 © AS BUILTS 2-20-18 DRAWN BY: CARLOS VIIACA 1000 S DIXIE HWY. WEST POMPANO BEACH FLA. 33060 PHONE:561- 445- 9661 EMAIL, carloaWaca2Mmail.com DATE 3-1-17 SCALE: 3AIS' = Nr ROJECT : NOMRS-CFRMFS SHEET 1- E1 INSTALL ALL ELECTR/CAL WRING AND COPON£NTS AS PER PLAN. ARC FAULT INTFRRUPT TYPE OUTLETS SHALL BE INSTALLED IN ALL BEDROOMS . SMOKE DETECTORS THAT ARE HARD WRED, INTERCONN£CTEO AND HALF A BATTERY BACKUP ARE TO BE INSTALLED IN ALL BEDROOMS AND A COMBINATION SMOKE/C TO BE INSTALLED W11N 10' OF SLEEPING AREAS GFI RECEPTTCLES ARE TO BE INSTALLED IN KITCHEN AND ALL BATHROOMS . ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION MOUNTED LIGHT SECURITY SPOT LIGHTS EB LED RECESSES EYE BALL .4 TELEPHONE JACK SWITCH [rv}+ TELEVISION / INTERNET SWITCH 3 WAY SMOKE DETECTOR RECEPTACLE �° CARBON MONOXIDE DETECTOR GROUND FAULT INDIC EXHAUST FAN UNDER COUNTER LIGHT O LED HI -HAT D. CAMERA ® LED HI -HAT (MINI) 220 VOLT RECEPTACLE ELECTRICAL METER ELECTRICAL PANEL DISCONNECT ® SPECIAL RECEPTACLE p PENDANT LIGHT ELECTRICAL NOTES: 1 OFLTHE N?ETC. 2011RKAND LOCAL GOVERNING CODES REVISION 2. ALL WIRING TO BE COPPER UNLESS OTHERWISE NOTED. 3. ALL MATERIALS, WHERE APPLICABLE, SHALL BE U.L. LABELED 4. ALL OPENINGS REQUIRED BY ELECTRICAL CONTRACTOR TO BE CLOSED TO MATCH FINISH AND FIRE RATED BY ELECTRICAL CONTRACTOR. 5, INSTALLATION HEIGHTS ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED: WALL HUNG TELEPHONE 56" A.F.F. TELEPHONE JACKS 12" A.F.F. LIGHT SWITCHES 48" A.F.F. RECEPTACLES 12" A.F.F. TELEVISION JACKS 12" A.F.F. 6. CO-ORDINATE ALL CONDUIT RUNS AND EQUIPMENT INSTALLATION WITH OTHER TRADES TO AVOID CONFLICTS PRIOR TO FABRICATION, INSTALLATION AND ERECTION. 7. ELECTRICAL CONTRACTOR TO VERIFY ALL HVAC UNIT CONNECTIONS WITH HVAC CONTRACTOR PRIOR TO INSTALLATION. g ALL METERS, METER CENTERS AND DISCONNECTS TO BE APPROVED BY FLORIDA POWER AND LIGHT. 9. LOCATION OF ELEC. REC. SHALL COMPLY W/ NEC-210-52 AND RECEPTACLE SPACING SHALL COMPLY WITH NEC 210-72. LIGHTING OUTLETS SHALL COMPLY WITH NEC-210-8 10. ALL NEW CIRCUITS TO BE ARC FAULT PROTECTED NEC 2008 210.12 11. ALL NEW RECEPTICLES TO BE TAMPER RESISTANT NEC 406.11 ELECTRICAL PLAN 3/18' = T-0' File Copy 1 PXMIONS BY © AS BUILTS 2-20-18 P. CV m b 0 .. (D a4�� A! 0 0 x Q loll " C) Q M C'4 �$ �i LLJ d �b� bff log b DRAWN BY: CAlWW V�1CA 1000 S DIXIE HWY. WEST POMPANO BEACH FLA. 33060 PHONE:561— 445— 9661 EMAIL• carImAlaca203mall.com DATE 3-1-17 SCALE: 3/16' = r-O' PROJECT: NOMFIS-UMMM NEW ELECTRICAL PANEL A NEW ELECTRICAL PANEL B 200A M.C.B PANEL 120 / 240v 1� 3W(SURFACE) CKT SERVES CB P KW WIRE-COND. CKT SERVES CB P KW WIRE-COND. 02 AC 2,3,4 100 2 29.0 _rROTINn Ol POWDER RM. LIGHTS 15 1 .8 # 14 04 SUB PANEL T 03 POWDER RM. GFCI RECEPT 20 1 1.5 # 12 06 GAS OVEN STARTER 20 1 1.0 # 12 D5 VIP GUEST BATH GFI 20 1 1.5 # 12 08 GAS OVEN STARTER 20 1 1.0 # 12 07 VIP GUEST BATH LIGHTS 15 1 .8 # 14 10 MASTKR BATH GFI 20 1 1.5 # 12 09 VIP GUEST BED LIGHTS 15 1 .8 # 14 12 MASTER BATH GFI 20 1 1.5 # 12 11 VIP GUEST BED RECEPT 15 1 .8 # 14 14 MASTER LIGHTS 15 1 .8 # 14 13 BAR GFI RECEPTACLES 20 1 1.5 If 12 16 MASTER BATH LIGHTS 15 1 .8 # 14 15 BAR LIGHTS 15 1 .8 # 14 18 MASTER BATH TUB 20 1 1.6 # 12 17 DINING RMM, RECEPTACLES 20 1 1.5 # 12 20 MASTER RECEPTACLES 15 1 B # 14 19 DINING RM. LIGHTS 15 1 .8 # 14 22 FOYER LIGHTS 15 1 .8 # 14 21 BATH 16 GFCI RECEPT 20 1 1.5 # 12 24 FOYER RECEPTACLES 15 1 .8 # 14 23 BATH #6 LIGHTS 15 1 .8 # 14 26 LIVING LIGHTS 15 1 .8 # 14 25 SMOKE DETECTORS 15 1 .8 # 14 28 LIVING RECEPTACLES 15 1 .8 # 14 27 GRILL LIGHTS 15 1 .8 # 14 30 PORCH LIGHTS 15 1 .8 # 14 29 Fig RM. RECEPT 15 1 .8 # 14 32 PORCH WP/GFCI RECEPT 20 1 1.5 # 12 31 FAMILY RM. LIGHTS 15 1 .8 # 14 34 GRILL WP/GFCI RRCEPT 20 1 1.5 # 12 33 SPARE -- -- 38 TANKLESS WH GAS #1 20 1 1.0 # 12 35 SPARE -- -- 38 TANKLESS WH GAS #2 20 1 1.0 # 12 37 SPARE -- -- 40 99 SPARE -- -- 41 SPARE -- -- 46.9 15.5 CALCULATIONS TOTAL CONNECTED LOAD FIST 10 XT 0 100% a/e 27.5111 0 65% REST @ 40% - 41.86 X 1000 240 = 173.67 AMPS TOTAL CONNECTED LOAD 62.4 200A M. C. B PANEL 120 / 240v 1N 3W (SURFACE) CKT SERVES CB P KW WIRK-COND. CKT SERVES CB P KW WIRE-COND. 02 AC #1,4/POOL 60 10.5 3 #6 - 1 #BG 01 SECURITY RECEPTACLES 15 1 .8 # 14 04 SUB PANEL "2 03 DRYER #1 30 2 6.0 # 10 OB PAVILION SUB 60 2 11.4 3 -#6 -1 #BG 05 08 SUB PANEL "3" 07 DRYER #2 30 2 5.0 # 10 10 LAUNDRY RM. GFI 20 1 1.5 # 12 09 12 LAUNDRY RM. LIGHTS 15 1 .8 # 14 11 WASHER # 1 20 1 1.0 # 12 14 KITCHEN GFCI RECEPTACLE 20 1 1.5 # 12 13 WASHER # 2 20 1 1.0 # 12 16 KITCHEN GFCI RECEPTACLE 20 1 1.5 # 12 15 BATH #25 GFCI RECEPT 20 1 1.5 # 12 18 KITCHEN GFCI RECEPTACLE 20 1 1.5 # 12 17 BED/BATH #2 LIGHTS 15 1 .8 # 14 20 KITCHEN LIGHTS 15 1 .8 If 14 19 BED RM. #2 RECEPTACLES 20 1 1.5 # 12 22 MICROWAVE 20 1 1.0 # 12 21 BED/BATH #3 GFCI RECEPT 20 1 1.0 # 12 24 MICROWAVE 20 1 1.0 # 12 23 HID/BATH #3 LIGHTS 15 1 .8 # 14 26 FREEZER #1 20 1 1.0 # 12 25 BED RM. #3 RECEPTACLES 20 1 1.0 # 12 28 FREEZER #2 20 1 1.0 12 27 BED/BATH #4 GFCI RECEM 20 1 1.0 If 12 30 REFRIGERATOR #1 20 1 1.0 12 29 BED/BATH #4 LIGHTS 15 1 .8 # 14 32 REFRIGERATOR #2 20 1 1.0 12 31 BED RM. #4 RECEPTACLES 20 1 1.0 # 12 34 DISPOSAL 20 1 1.5 # 12 33 LIVING #2 LIGHTS 15 1 .8 # 14 36 GAS STOVE STARTER 15 1 .8 14 35 LIVING #2 RECEPTACLES 20 1 1.0 # 12 38 HOOD 20 1 1.5 # 12 37 BAR #2 RECEPTACLES 20 1 1.5 # 12 40 GAS OVEN STARTER 15 1 .8 # 12 39 WELL PUMP 20 1 1.5 # 12 42 GAS OVEN STARTER 15 1 .8 # 12 41 SPARE -- -- 49,7 26.5 CALCULATIONS TOTAL CONNECTED LOAD 78.2 xW 62.4 KW FAST 10 KW 0 100% 10.0 KI 10.0 KW a/c 15 KW 6 65 9.76 KW 17.88 KW RRSf 51.6 0 40% 22.58 ET 18.80 KW 31.94 KW 41.86 XW NEW ELECTRICAL PANEL D GYM 200A M. C. B PANEL 120 / 240v 1N 3W(SURFACE)_ CKT SERVES CB P KW WIRE-COND. CKT SERVES CB P KW TIRE-COND. 02 BATTING CAGE RECEPT 20 1 1.5 # 12 01 BATTING CAGE LIGHTS 15 1 .8 # 14 04 BATTING CAGE RECEPT 20 1 1.5 # 12 03 BATTING CAGE LIGHTS 15 1 1 .8 # 14 06 BATTING CAGE RECEPT 20 1 1.5 # 12 05 BATTING CAGE LIGHTS 15 1 .8 # 14 08 AC COMPRESSOR 7 45 V -- # 8 07 AHU #7 60 1 10.0 # 6 10 (NON -CONCURRENT) 09 12 AHU #8 80 1 10.0 # 6 11 AC COMPRESSOR 8 (NON -CONCURRENT) KITCHEN GFCI 45 2 -- # 8 1¢ 13 16 EXTERIOR RECEPTACLES 20 1 1.5 # 12 15 20 1 1.6 # 12 IB REFRIGERATOR 20 1 1.0 # 12 17 KITCHEN GFCI 20 1 1.5 # 12 20 WATER BEATER #1 20 1 1 1.5 # 12 19 EICHEN/HALLWAY LIGHTS GYM LIGHTS GYM LIGHTS 16 1 .8 # 14 22 ICE MACHNCE 20 1 2.0 # 12 21 15 1 1 .8 # 14 24 23 15 1 .8 # 14 26 BATHROOM GFCI 20 1 1.5 # 12 25 BATHROOM LIGHTS BATHROOM LIGHTS 16 1 .8 # 14 28 HOT TUB 20 1 2.0 # 12 27 15 1 .8 # 14 30 7 29 TUB ROOM LF(HTS 15 1 .8 # 14 32 GYM RECEPTACLES 20 1 1.5 # 12 31 GARAGE CARPORT 60 2 12.2 3 #6 - i flOG 34 GYM RECEPTACLES 20 1 1.5 # 12 33 SUB PANEL I 38 GYM RECEPTACLES 1 20 1 1.5 # 12 35 -- -- 38 SPARE -- -- 37 SPARE -- -- 40 SPARE -- -- 39 SPARE -- -- 42 SPARE -- -- 41 SPARE -- -- 28.5 32.4 CALCULATIONS TOTAL CONNECTED LOAD FOIST 10 ET 0 IDOX a/c 20 0 66% REST 18.7040X TOTAL DEMAND WAD TOTAL CONNECTED LOAD 60.9 60.90 KW 10 ET 13 KW 15.10 KT 30.48 ET 38.16 x 1000 38,160 = 159 AMPS 240 GYM/BATTING GAGE TOTAL 76.2 42.33 x 1000 2� = 178.98AYP5 HOUSE PANELS A/C 114 / POOL SUB PANEL #2 60A M.C.B PANEL 120 / 240v 1N 3W(SURFACE) CKT SERVES CB P KW WIRE-COND. CKT SERVES KW WIRE-COND. 01 AC COMPRESSOR 1 (4 TON) 50 203 -- # 8 02 AHU #1 2 10.0 #6 04 JBP 05 ABU #4 30 2 5.0 # B 06 AC COMPRESSOR 4 (2 TON 2 -- # 10 07 08 09 POOL PUMP 20 1 1.0 # 12 10 EXTERIOR WP GFI 20 1 1.5 # 12 11 POOL FILTER 20 1 1.0 # 12 12 SPARE -- I -- 7.0 TOTAL 11.5 TOTAL TOTAL CONNECTED LOAD 18.5 A/C 1,4 /POOL SUB PANEL #2 A/C 2,3,5 SUB PANEL #E 100A M.C.B PANEL 120 / 240v 1N 3W(SURFACE) CKT SERVES CB P Elf WIRE-COND. CKT SERVES CB P KW WIRE-COND. Ol COMPRESSOR 2 (4 ton) -- # 8 02 ABU #2 60 2 10.0 # 6 03 xz 04 05 AHU #3 60 2 10.0 # 6 OB AC COMPRESSOR 3 (5TON) 50 2 -- # 8 07 08 09 AC COMPRESSOR 5 (3 TON) 50 2 __ # 8 10 AHU #5 60 2 7.5 # 6 11 12 13 SPARE -- -- 14 E MMOR WP/GFI 20 1 1.5 # 12 15 SPARE -- -- 16 SPARE -- -- 10.0 19 TOTAL CONNECTED IAAD 29.0 AC 2,3,5 SUB PANEL E GARAGE/CARPORT SUB PANEL #1 60A M. C. B PANEL 120 / 240v 1N 3W (SURFACE) CKT SERVES CB P KW WIRE-COND. CKT SERVES CB P ET WINE-COND. OS GENERAL LIGHTS 15 1 .8 # 14 02 WP/GFCI RECEPTACLES 20 1 1.5 # 12 03 GENERAL LIGHTS 15 1 .8 # 14 04 WP/GFCI RECEPTACLES 20 1 1.5 # 12 05 GENERAL LIGHTS 15 1 .8 # 14 06 WP/GFCI RECEPTACLES 20 1 1.5 # 12 07 GENERAL LIGHTS 15 1 .8 If 14 08 WP/GFCI RECEPTACLES 20 1 1.5 # 12 09 GARAGE DOOR OPN'R #1 20 1 1.5 # 12 10 GARAGE DOOR OPN R #2 20 1 1.5 # 12 11 SPARE -- -- 12 SPARE -- -- 13 SPARE -- -- 14 SPARE -- -- 15 SPARE -- -- 18 SPARE -- -- 17 SPARE -- -- 18 SPARE -- -- 19 SPARE -- -- 20 SPARE -- -- 4.7 7.5 TOTAL TOTAL CONNECTED LOAD 12.2 GARAGE/CARPORT SUB PANEL #1 NEW ELECTRICAL "PAVILION" SUB -PANEL 3 100A M. C. B PANEL 120 / 240v 1N 3W (SURFACE) CKT SERVES CB P KW WIRE-COND. CKT SERVES CB P KW WIRE-COND. 02 FAN/LIGHT 15 1 .8 # 14 01 WP/GFCI RECEPTACLES 20 1 1.5 # 12 04 GENERAL LIGHTS 15 1 .8 # 14 03 WP/GFCI RECEPTACLES 20 1 1.5 # 12 06 RESTROOM LIGHTS 15 1 .8 # 14 05 WP/GFCI RECEPTACLES 20 1 1.5 # 12 08 POOL LTGS -- -- 07 RESTROOM GFCI REM 20 1 1.5 # 12 10 POOL PUMP -- -- 09 WATER FALL PUMP 20 1 1.5 # 12 12 POOL FILTER -- -- 11 ICE MAKER 20 1 1.6 # 12 14 JACUZZI PUMP -- -- 13 SPARE -- 16 SPARE -- -- 15 SPARE -- -- 18 SPARE -- -- 17 SPARE -- -- 20 1 SPARE -- -- 19 SPARE -- CO24 9-0 File PY- TOTAL CONNECTED WAD 11.4 PAVILION SUB PANE r , 'ry h 1 s REVISIONS BY AS BUILTS 2-20-18 DRAWN BY: CARLOS VILACA POMPANOxBEACHYFLWEST 33060 PHONE:561- 445- 9661 EMAIL,• corlos Alaca2®GmatLcom DATE 34-17 SCALE: 3/16" = P-0" PROJECT : NOMM-CE FMIES 3-#6, 1-#8 G, IN 60 A SU PNL-1 GA CARPORT 42 CIR. FROM OUTSIDE INTERSYSTEM BONI AS PER NEC 25C 3-#6, 1-#8 G, IN 1-1/2" CU. 60 A SUB PNL-2 AC A / POOL 16 R. NEW HOME NEW HOME PANEL B PANEL A 42 CIR. 42 CIR. 200 AMP 200 AMP 3- If 2[0 3-12[0 2' ADDUIT 2' ADUIT FROM OUTSIDE FROM OUTSIDE INSIDE HOUSE PANELS ,: e . , M a A7/A OUTSIDE HOUSE PANELS DRIVEN 8' DEEP N TS 3-#6, 1-#8 G, IN 1-1/2" CU. 60 A SUB PNL-3 PAVILION 42 CIR. 100 AMP PANEL E AC #2,3,&5 3 3-THWN 1- 8 GRQUND IN -1/2 CONDUIT Cu GROUND IN 1" PVC TO 2-5/8" x 10' C.U. ROD SOOP(MIN2 0 FOUNDATION ELECTRICAL RISER REVISIONS BY %L AS BUILTS 2-20-18 File COPY tag s .. � INOO A! o J I x �7 181 �� NQ " awe �a MH Jill 6 d' /1�� N 1^ � I rM � d " a z X F+�1 O O w� FF'+vriM J W O W � N I wm ONO U O I� m �w m o w a DRAWN BY: CAUDS VRACA 1000 S DIXIE HWY. WEST POMPANO BEACH FLA. 33060 PHONE:561- 445- 9661 EMAIL: carloadlacaMmaO.com DATE M-1% SCALE: Y18' = Mr PROJECT :