HomeMy WebLinkAboutEngineering C lJCEngin erin cli
SpeK-laity Structural EnginPerinq CdUCK,Inc.Certificate of Authorization#8064
REG"IVED
Evaluation Report
"Ultra HT Wind & Water Seal,"I" OCT 01 Z017
I
Roof Underlayment PERMITTINGSt,Lucie County,FL
HESE PLANS AND ALL PROPOSED WORK O
:RE SUBJECT TO ANY CORRECTIONS Manufacturer: ti
REQUIRED BY FIELD INSPECTORS THAT 1. Z
MAY BE NECESSARY IN ORDER TO MFM Building Products Corp. o
COMPLY WITH ALL APPLICABLE cODES. 11711 a W
525 Orange Street t�
Coshocton, Ohio 43812 \ w
(740) 622-2645
for
FASTENERS ORa7TCH�4iaA Florida Product Approval F•
ARE THE RESPONS,81LdTy OF TS THE
CWRACToaOF # FL 11842.5 Ri c w
RECORD
Florida Building Code 5th Edition (2014)
1:. ww
Method: 1 - D
w
1 —� » �.,
Category: Roofing I � �; � .,, �, r
Sub - Category: " Underlaymient
i
I I
Product: "Ultra HT Wind &Water SeaITMJ)
Description: Self-Adhered Underlayment
I I
Prepared by:
James L. Buckner, P.E.,SECB
Florida Professional En ineer#31242 �
g
Florida Evaluation ANE ID: .1916 1 .�` �• BU '�,
Project Manager: Diana Galloway �P.• ;\cENSF
Report No. 15-115-UHT-ER = * No31242
(Revises 13-161-UHT-ER,FL26562.1)
Date: 4/02/15 LU
STATE OF _��
Contents: /,`S/ON.....
Evaluation Report Pages 1—5 i '1 i r,,, W
r .
CBUCK,Inc. Digitally Signed by.James L Buckner,P.E-
1399 N.Killian Drive,Suite 4,West Palm Beach,Florida 33403
1 2015.04.1613:38:50-04'00'
Phone:(561)491-9927 Fax:(561)491-9928 Website:www.cbuckinc m-t
"Ile Copy
FL#: FL 11842.5 R3
Date: 4/2/15
C VC n eerie" Page Report No.:2 -11 55-UHT-ER
I
I
SpeK-_ldlty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
I.
I
Manufacturer: MFM Building Products Corp.
I' I
Product Name: "Ultra HT Wind&Water SeaITM"
i
Product Category: Roofing
I,
Product Sub-Category Underlayment
Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d)
Product Description: "Ultra HT Wind &Water SeaITM" is self-adhering membrane composed of a white,
non-slip cross-laminated polymer film, laminated to a rubberized asphalt adhesive
with a split release liner designed for use as a roof' underlayment in high
temperature conditions.
Product Material/ Material Type: Styrene Butadiene Styrene(SBS)
Standards: Material shall comply with ASTM D 1970 per Florida Building Code FBC 5th Edition
(2014),Chapter 15.
Product Dimension(s) Roll Size:36 in.x 67 ft. rolls
Thickness:45 mils (nominal)
Substrate(s): "Ultra HT Wind & Water SealTM" has been evaluated {for application to the
following substrates(Design of support is outside the scope of this evaluation):
• Plywood
• Dens Deck
Installation: General Installation Instructions:
"Ultra HT Wind & Water Seal" shall be installed in accordance with the
attached installation method and in compliance with applicable code sections of
the FBC 5th Edition (2014), subject to the ;Limitations and Conditions of Use
listed in this Evaluation Report. i
I
Refer to installation details at the end of this report. Refer to manufacturer's
installation instructions as a supplemental guide for attachment.
I
� I
II
'
I' I
{
FL1#: FL 11842.5 R3
Date: 4/2/15
CSUCIG n in� =rinq Page rt No.:3 of 55-UHT-ER
I
Specialty Structural Enginemerinq
CBUCK,Inc.Certificate of Authorization#8064
a
Performance Standards: The product described herein has demonstrated compliance with:
• ASTM. D 1970-09 — Specification Self-adhering Polymer Modified
Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam
Protection
Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the
prescribed standards in ASTM D 1970-09 1,standard version adopted by the
Florida Building Code 5th Edition (2014)for'use as evaluated in this report.
Code Compliance: The products described herein have demoinstrated compliance with ASTM D
1970-09 of Florida Building Code 2010.
Evaluation Report Scope: This product has been evaluated in compliance with ithe building envelope
requirements of the Florida Building Code,:as related to the scope section to
Florida Product Approval Rule 61G20-3.001
Product Limitations and • Deck shall be in compliance with applicable building code.
Conditions of Use: • Minimum slope shall be 2:12 or greater.
• Installation is limited to use with approved roof coverings that are
mechanically fastened through the underlayment ;and is attached to the
sheathing or rafters.
• Not to be applied over active solvents or sealants, EPDM rubber or
products containing silicone.
• Do not expose product to direct sunlight for more than 60 days.
General Limitations and • Scope of"Limitations and Conditions of Use"for this'evaluation:
Conditions of Use: This evaluation report for "Optional Statewide Approval' contains
technical documentation, specifications and install'ation method(s) which
include "Limitations and Conditions of Use" throughout the report in
accordance with Rule 611320-3.005. iPer Rule 61620-3.004, the Florida
Building Commission is the authority to approve products under
"Optional Statewide Approval".
• Option for application outside"Limitations and Conditions of Use"
Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with
the alternate methods and materials authorized in the Code". Any
modification of the product as evaluated in this report and approved by
the Florida Building Commission is outside the scope of this evaluation
and will be the responsibility of others
r
• Fire Classification is outside the scope of,;Rule 61G20;3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use oflthis product for use in
the High Velocity Hurricane Zone code section. (Dade & Broward
Counties)
I' I
I
I
FL'#: FL 11842.5 R3
Date: 4/2/15
CBUCK nlneerl Page port No.:4 of 55-UHT-ER
ONI
Spe--iait j Structural Engineerinci CBUCK,Inc.Certificate of Authorization l8064
I
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 161G20-3.0005 (3) for
manufacturing under a quality assurance 'program audited by an approved
quality assurance entity through Keystone Certifications, Inc. (FBC
Organization ID#QUA 1824).
Referenced Data: 1. ASTM D 1970-01 Test
By PRI Construction Materials Technologies, Inc.
(FBC Organization ID#TST 1556)
Report No. MFM-039-02-01, Date: 8/1 I 5/13
I
2. Equivalency of Test Standard Certification. !
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization#ANE 1916)
i
3. Quality Assurance I
Keystone Certifications, Inc. (FBC Organization ID#QUA 1824)
MFM Building Products Corp. Licensee,;#335
4. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization#ANE 1916)
I
l; I
I �
i
i
I !
' I
I
I' I
I, ,
1
F i M FL 11842.5 R3
Date: 4/2/15
CBUCK n ineerin� Page No.:5 of 55-UHT-ER
9
Specialty Structural Engineering CBUCK,Inc.Certifcate of Authorization#�8064
I
INSTALLATION METHOD
MFM Building Products Corp.
Ultra HT Wind & Water Seal
Self-Adhered Roofing Underlayment
General Installation Instructions:
I
• Product to be applied directly to a clean dry surface.
• Prime any weathered surfaces. Dens Deck must be primed with asphalt base primer.
• Starting at the low point of the deck, peel back 12"of the release liner, align the membrane and press
into place onto roof deck.
• Adhesive is pressure-activated, so press firmly into place using uniform pressure with a 2-3" heavy
steel or rubber roller to seams and overlap.
• Overlap end laps a minimum of 6".Side laps must be a minimum of8".
• Store product in the carton in a dry place until ready to use. Keep product out of direct sunlight.
• Apply membrane only in fair weather when the air, surface and membrane are at a minimum
temperature of: 50' F
• Not to be applied over active solvents or sealants, EPDM rubber or pr"oducts containing silicone.
I.
• Do not expose product to direct sunlight for more than 60 days.
Refer to the manufacturer's installation instructions as a supplemental guide forattachment.
Product Illustrations
V U LTRA HT
WIND&WATER SEAL
Cal
k Y '
2_
I
I3
f
i