Loading...
HomeMy WebLinkAboutEngineering C lJCEngin erin cli SpeK-laity Structural EnginPerinq CdUCK,Inc.Certificate of Authorization#8064 REG"IVED Evaluation Report "Ultra HT Wind & Water Seal,"I" OCT 01 Z017 I Roof Underlayment PERMITTINGSt,Lucie County,FL HESE PLANS AND ALL PROPOSED WORK O :RE SUBJECT TO ANY CORRECTIONS Manufacturer: ti REQUIRED BY FIELD INSPECTORS THAT 1. Z MAY BE NECESSARY IN ORDER TO MFM Building Products Corp. o COMPLY WITH ALL APPLICABLE cODES. 11711 a W 525 Orange Street t� Coshocton, Ohio 43812 \ w (740) 622-2645 for FASTENERS ORa7TCH�4iaA Florida Product Approval F• ARE THE RESPONS,81LdTy OF TS THE CWRACToaOF # FL 11842.5 Ri c w RECORD Florida Building Code 5th Edition (2014) 1:. ww Method: 1 - D w 1 —� » �., Category: Roofing I � �; � .,, �, r Sub - Category: " Underlaymient i I I Product: "Ultra HT Wind &Water SeaITMJ) Description: Self-Adhered Underlayment I I Prepared by: James L. Buckner, P.E.,SECB Florida Professional En ineer#31242 � g Florida Evaluation ANE ID: .1916 1 .�` �• BU '�, Project Manager: Diana Galloway �P.• ;\cENSF Report No. 15-115-UHT-ER = * No31242 (Revises 13-161-UHT-ER,FL26562.1) Date: 4/02/15 LU STATE OF _�� Contents: /,`S/ON..... Evaluation Report Pages 1—5 i '1 i r,,, W r . CBUCK,Inc. Digitally Signed by.James L Buckner,P.E- 1399 N.Killian Drive,Suite 4,West Palm Beach,Florida 33403 1 2015.04.1613:38:50-04'00' Phone:(561)491-9927 Fax:(561)491-9928 Website:www.cbuckinc m-t "Ile Copy FL#: FL 11842.5 R3 Date: 4/2/15 C VC n eerie" Page Report No.:2 -11 55-UHT-ER I I SpeK-_ldlty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 I. I Manufacturer: MFM Building Products Corp. I' I Product Name: "Ultra HT Wind&Water SeaITM" i Product Category: Roofing I, Product Sub-Category Underlayment Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product Description: "Ultra HT Wind &Water SeaITM" is self-adhering membrane composed of a white, non-slip cross-laminated polymer film, laminated to a rubberized asphalt adhesive with a split release liner designed for use as a roof' underlayment in high temperature conditions. Product Material/ Material Type: Styrene Butadiene Styrene(SBS) Standards: Material shall comply with ASTM D 1970 per Florida Building Code FBC 5th Edition (2014),Chapter 15. Product Dimension(s) Roll Size:36 in.x 67 ft. rolls Thickness:45 mils (nominal) Substrate(s): "Ultra HT Wind & Water SealTM" has been evaluated {for application to the following substrates(Design of support is outside the scope of this evaluation): • Plywood • Dens Deck Installation: General Installation Instructions: "Ultra HT Wind & Water Seal" shall be installed in accordance with the attached installation method and in compliance with applicable code sections of the FBC 5th Edition (2014), subject to the ;Limitations and Conditions of Use listed in this Evaluation Report. i I Refer to installation details at the end of this report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. I � I II ' I' I { FL1#: FL 11842.5 R3 Date: 4/2/15 CSUCIG n in� =rinq Page rt No.:3 of 55-UHT-ER I Specialty Structural Enginemerinq CBUCK,Inc.Certificate of Authorization#8064 a Performance Standards: The product described herein has demonstrated compliance with: • ASTM. D 1970-09 — Specification Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the prescribed standards in ASTM D 1970-09 1,standard version adopted by the Florida Building Code 5th Edition (2014)for'use as evaluated in this report. Code Compliance: The products described herein have demoinstrated compliance with ASTM D 1970-09 of Florida Building Code 2010. Evaluation Report Scope: This product has been evaluated in compliance with ithe building envelope requirements of the Florida Building Code,:as related to the scope section to Florida Product Approval Rule 61G20-3.001 Product Limitations and • Deck shall be in compliance with applicable building code. Conditions of Use: • Minimum slope shall be 2:12 or greater. • Installation is limited to use with approved roof coverings that are mechanically fastened through the underlayment ;and is attached to the sheathing or rafters. • Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone. • Do not expose product to direct sunlight for more than 60 days. General Limitations and • Scope of"Limitations and Conditions of Use"for this'evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and install'ation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 611320-3.005. iPer Rule 61620-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval". • Option for application outside"Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others r • Fire Classification is outside the scope of,;Rule 61G20;3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use oflthis product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) I' I I I FL'#: FL 11842.5 R3 Date: 4/2/15 CBUCK nlneerl Page port No.:4 of 55-UHT-ER ONI Spe--iait j Structural Engineerinci CBUCK,Inc.Certificate of Authorization l8064 I Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 161G20-3.0005 (3) for manufacturing under a quality assurance 'program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID#QUA 1824). Referenced Data: 1. ASTM D 1970-01 Test By PRI Construction Materials Technologies, Inc. (FBC Organization ID#TST 1556) Report No. MFM-039-02-01, Date: 8/1 I 5/13 I 2. Equivalency of Test Standard Certification. ! By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) i 3. Quality Assurance I Keystone Certifications, Inc. (FBC Organization ID#QUA 1824) MFM Building Products Corp. Licensee,;#335 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) I l; I I � i i I ! ' I I I' I I, , 1 F i M FL 11842.5 R3 Date: 4/2/15 CBUCK n ineerin� Page No.:5 of 55-UHT-ER 9 Specialty Structural Engineering CBUCK,Inc.Certifcate of Authorization#�8064 I INSTALLATION METHOD MFM Building Products Corp. Ultra HT Wind & Water Seal Self-Adhered Roofing Underlayment General Installation Instructions: I • Product to be applied directly to a clean dry surface. • Prime any weathered surfaces. Dens Deck must be primed with asphalt base primer. • Starting at the low point of the deck, peel back 12"of the release liner, align the membrane and press into place onto roof deck. • Adhesive is pressure-activated, so press firmly into place using uniform pressure with a 2-3" heavy steel or rubber roller to seams and overlap. • Overlap end laps a minimum of 6".Side laps must be a minimum of8". • Store product in the carton in a dry place until ready to use. Keep product out of direct sunlight. • Apply membrane only in fair weather when the air, surface and membrane are at a minimum temperature of: 50' F • Not to be applied over active solvents or sealants, EPDM rubber or pr"oducts containing silicone. I. • Do not expose product to direct sunlight for more than 60 days. Refer to the manufacturer's installation instructions as a supplemental guide forattachment. Product Illustrations V U LTRA HT WIND&WATER SEAL Cal k Y ' 2_ I I3 f i