Loading...
HomeMy WebLinkAboutProduct Approval CBUCK Engine0ring IN I Spec1cslty Structural Englneerinq CBUCK,Inc.Certificate of Authorization#8064 RECEIVED OCT 0:3 2017 0 Evaluation Report PERMITTIN ti z "Ultra HT Wind & Water SeaIT11" St. Lucie Coun 'F O aF, Roof Underlayment j Ca V W rie Manufacturer: MFM Building Products Corp. p� 525 Orange Street o o Coshocton, Ohio 43812 o �- ki (740) 622-2645 \� La. �' a aW, on ca . THESE PLANS AND ALL PROPOSED WORK for 5 "r -r• ARE SUBJECT TO ANY CORRECTIONS �� +� i O REQUIRED BY FIELD INSPECTORS THAT Florida Product Approval , , �, MAY BE NECESSARY IN ORDER TO # F L 11842.5 R3 COMPLY WITH ALL APPLICABLE Congo, Florida Building Code 5th Edition (2014) Method: 1 - D ' CONCEALED FASTENERS OR ATTACHMENTS Category: Roofing Sub - Category: Underlayment ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD Product: "Ultra HT Wind &Water SealTM11 Description: Self-Adhered Underlay ent iPrepared by: James L. Buckner, P.E.,SECB Florida Professional Engineer#31242 Florida Evaluation ANE ID: 1916 ��`�E5 L; Buc,� Project Manager: Diana Galloway ��Q • '��cENSF '�'F,Q�% Report No. 15-115-UHT-ER No31242 (Revises 13-161-UHT-ER,FL16562.1) Date: 4/02/15 iu 0T STATE OF 2�` Contents: %,��,' •FcORIOP •' C� Evaluation Report Pages 1—5 IONA1,e\\\ 6.ex �. CBUCK,Inc. File Copy iOigiatty Signed by.James L Buckner,P.E. 1399 N.Killian Drive,Suite 4,West Palm Beach,Florida 33403 2015.04.1613:38:50-04'00' Phone:(561)491-9927 Fax:(561)491-9928 Website:www.cbuckinc.net i t�? Ai. r BCLS Home Log In I User Replst.V,m I Hot T.PJ.I Submit surcharge I Stets&Facts I publlraUom I FSC Sbfl I BCLS site Map Links I Search I Or Product Approval USER:publicU— ProauR Aooroval Menu>prOLuct or Aoolla[lan Search>Apollcatlan Llst>ADpUmtlm Detail I „ FL# FL11842-R3 Application Type Revislon Code Version 2014 Application Status Approved Comments Archived ❑ Product Manufacturer MFM Building Products Corp. Address/Phone/Email 525 Orange St. P.O.Box 340 Coshocton,OH 43812 (740)622-2645 wcroR@mfmbp.com Authorized Signature James Buckner Jimmy@cbuckinc.net Technical Representative Whit Cron Address/Phone/Email PO Box 340 Coshocton,OH 43812 (740)622-2645 Ext 118 wcroR@mfmbp.com I Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments I I Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑Evaluation Report-Hardcupy Received I Florida Engineer or Architect Name who developed the Evaluation Report James L.Bucker,P.E.@ CBUCK Engineering Florida License PE-31242 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 12/31/2019 Validated By Steven M.Urlch,PE 0 Validation Checklist-Hardcopy Received Certificate of Independence FL11842 R3 COI CertOtlndeo odf Referenced Standard and Year(of Standard) Standard Vear ASTM D 1970 2009 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL11842 R3 Fouly Test Standard Eauly.odf I I Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/16/2015 Date Validated 04/23/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/22/2015 Date Revised 08/10/2017 Summary of Products l I FL# Model,Number or Name Description 11842.1 1-"IB3","IB3 StormStopper",1133 Shingle Self-Adhered Roof Underlayments attached to Plywood Deck Startee,"IB4 StormStopper"&"Shingle Starter" Limits of Use Installation Instructions Approved for use in HVHZ:No FL11842 R3 li 1 IB3Family EVALREPORT.odf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK,.Inc P.E.#31242 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Refer to Evaluation Report for(imitations and Conditions of Use.Refer to FL11842 R3 AE 1 IB3Famlly EVALREPORT.odf Manufacturer's Installation Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes 11842.2 2-"Peel&Seal" Self-Adhered Roof Underlayment attached to Plywood Deck I I I 1 I Limits of Use Installation Instructions Approved for use in HVHZ:No FL11842 R3 II 2 PS EVALREPORT.Ddf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK,Inc P.E.#31242 Impact Resistant:N/A Created by Independent,Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Refer to Evaluation Report for Limitations and Conditions of Use.Refer to FL11842 R3 AE 2 PS EVALREPORT.Ddf Manufacturer's Installation Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes 11842.3 3-"Wind&Water Seal+" Self-Adhered Roof Underlayment attached to Plywood Deck Limits of Use Installation Instructions Approved for use in HVHZ:No FL11842 R3 II 3 WWS EVALREPORT.odf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK,Inc P.E.#31242 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Refer to Evaluation Report for Limitations and Conditions of Use.Refer to FL11842 R3 AE 3 WINS EVALREPORT.ndf Manufacturer's Installation Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes 11842.4 14-"STS" Self-Adhered Roof Underlayment attached to Plywood Deck Limits of Use Installation Instructions Approved for use in HVHZ:No FL11842 R3 II 4 STS EVALREPORT.odf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK,Inc P.E.#31242 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Refer to Evaluation Report for Limitations and Conditions of Use.Refer to FL11842 R3 AE 4 STS EVALREPORT.Ddf Manufacturer's Installation Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes 11842.5 5-"Ultra HT Wind&Water Seal—' Self-Adhered Roof Underlayment attached to Plywood Deck Limits of Use Installation Instructions Approved for use in HVHZ:No FL11842 R3 II 5 Ultra HT EVALREPORT.Ddf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.P.E.#31242 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Refer to Evaluation Report for Limitations and Conditions of Use.Refer to FL11842 R3 AE 5 UltraHT EVALREPORT.Ddf Manufacturer's Installation Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes I Beal Heat i I Contact Vs:;2601 Blab Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AVEEO employer.C...d.ht 2007.2Ol3 Stet.of Florida.::PrI,a Statement::A c slblllty Statement::ReNnd statement I under norlda law,email addresses are public records.list,do not want your e-mall address released In response to a public-records request,do not send electmnlc mall N this'shbty.Instead,contact the once by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to section 455.275(1),Florida statutes,effeciAm October 1,2022,Ilcznsess Ilcensed under Chapter 455,F.S.must provlde the Department with an mall address Ifthey have one.The:malls provided may be used for,Md,l communication with the licensee.However mall addresses are public record.try,,do natwlsh to supply a personal address,please provlde the Department with an mall address which con be made avallable to the public To detem los If you are a licensee under Uapter 455,F.S.,please alckbi 3 P�rvduRApproval AA,capee; Credit Card Safe I I I i I I i i I I „ I i I i I i i l i FL#: FL 11842.5 R3 Date: 4/2/15 �� Page Report No.:2 of 55-UHT-ER N . 1 CB CK ngineer° SpeeclaIN Structural &nglne%-ring CB LICK,Inc.Certifcote of Authorization#8064 Manufacturer: MFM Building Products Corp. Product Name: "Ultra HT Wind&Water Seal•""" Product Category: Roofing j Product Sub-Category Underlayment Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) I Product Description: "Ultra HT Wind &Water Seal'""" is self-adhering membrane composed of a white, non-slip cross-laminated polymer film, laminated to a rubberized asphalt adhesive with a split release liner designed for use as a roof underlayment in high temperature conditions. Product Material/ Material Type: Styrene Butadiene Styrene(SBS) Standards: Material shall comply with ASTM D 1970 per Florida Building Code FBC 5th Edition (2014),Chapter 15. Product Dimension(s) Roll Size:36 in.x 67 ft. rolls Thickness:45 mils (nominal) Substrate(s): "Ultra HT Wind & Water Sea IT"°" has been evaluated ifor application to the following substrates(Design of support is outside the scope of this evaluation): • Plywood • Dens Deck Installation: General Installation Instructions: "Ultra HT Wind & Water SealTM11 shall be installed in accordance with the attached installation method and in compliance with applicable code sections of the FBC 5th Edition (2014), subject to the Limitations and Conditions of Use listed in this Evaluation Report. Refer to installation details at the end of this report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. I FL#: FL 11842.5 R3 Date: 4/2/15 P CBUCK Engineering Report No.:3 of 55-UHT-ER Specialty Structural Engin�rinq CBUCK,Inc.Certifii ate of Authorization n8064 I Performance Standards: The product described herein has demonstrated compliance with: • ASTM D 1970-09 — Specification Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection i Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the prescribed standards in ASTM D 1970-09 standard version adopted by the Florida Building Code 5th Edition (2014)for use as evaluated in this report. Code Compliance: The products described herein have demonstrated compliance with ASTM D 1970-09 of Florida Building Code 2010. Evaluation Report Scope: This product has been evaluated in compliance with ithe building envelope requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Product Limitations and • Deck shall be in compliance with applicable building code. Conditions of Use: • Minimum slope shall be 2:12 or greater. • Installation is limited to use with approved roof coverings that are mechanically fastened through the underlayment land is attached to the sheathing or rafters. • Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone. I • Do not expose product to direct sunlight for more than 60 days. General Limitations and • Scope of"Limitations and Conditions of Use"for this'evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval". • Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida BuildingCommission is outside the scope pe of this evaluation and will be the responsibility of others. • Fire Classification is outside the scope of Rule 61G2013, and is therefore not . included in this evaluation. • This evaluation report does not evaluate the use oflthis product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) I I 1 F LI#: FL 11842.5 R3 Date: 4/2/15 PReport No.:4 of 55-UHT-ER i .N Speclaltj Structural Englneerinq CBUCK,Inc.Certificate of Authorization#8064 Quality Assurance: The manufacturer has demonstrated compliance of of panel products in accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for manufacturing under a quality assurance grogram audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID#QUA 1824). I Referenced Data: 1. ASTM D 1970-01 Test By PRI Construction Materials Technologies, Inc. (FBC Organization ID#TST 1556) Report No. MFM-039-02-01, Date: 8/15/13 2. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#AN 1916) 3. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID#QUA 1824) MFM Building Products Corp. Licensee'#335 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) i i I f, I j i FL#: FL 11842.5 R3 Date: 4/2/15 CBUCI< ngineer ng P Report No.:5 of 55-UHT-ER I i Specialty Structural Engineerinq CBUCK,Inc.Certifcate of Authorization#8064 INSTALLATION METHOD MFM BuildingProducts Corp. p Ultra HT Wind & Water Seal Self-Adhered Roofing Underlayment i General Installation Instructions: • Product to be applied directly to a clean dry surface. • Prime any weathered surfaces. Dens Deck must be primed with asphalt base primer. • Starting at the low point of the deck, peel back 12"of the release liner, align the membrane and press into place onto roof deck. • Adhesive is pressure-activated, so press firmly into place using uniform pressure with a 2-3" heavy steel or rubber roller to seams and overlap. • Overlap end laps a minimum of 6".Side laps must be a minimum of 3". • Store product in the carton in a dry place until ready to use. Keep product out of direct sunlight. • Apply membrane only in fair weather when the air, surface and membrane are at a minimum temperature of: 50° F • Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone. • Do not expose product to direct sunlight for more than 60 days. i Refer to the manufacturer's installation instructions as a supplemental guide for attachment. Product Illustrations ;:;ULTRA HT ♦ WIND&WATER SEAL I I