Loading...
HomeMy WebLinkAboutProduct Approval (2) i RECEIV'D SEP 22 2017 BCIS Home Login I User Registration Hot Topic I Submit Surcharge Stats fl Facts Publications FBC Staff I`BQS Site Map j Links I Search Pflrida {� +�i r Product Approval I �,� ��USER:Public User Product Aooroval Menu>Product or Application Search>Application List>Application Detail I FL# FL17022-R6 Application Type Revision Code Version 2014 Application Status Approved I Comments Archived Product Manufacturer Extreme Metal Fabricators,LLC. Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 tara@extrememetalfabricators.com I Authorized Signature James Buckner jimmy@cbuckinc.net I Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 richard@emfab.net I Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed James L.Buckner,P.E. @ CBUCK,Inc. the Evaluation Report Florida License PE-31242 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Michael John Riemer,P.E. i7 Validation Checklist-Hardcopy Received i Certificate of Independence FL17022 R6 COI CertOfIndeo.odf Referenced Standard and Year(of Standard) Standard Year TAS 125 2003 UL 1897 2004 UL 580 2006 Equivalence of Product Standards Certified By I Sections from the Code I File Co i Product Approval Method Method 1 Option D Date Submitted 10/21/2016 Date Validated 12/29/2016 Date Pending FBC Approval 10/24/2016 Date Approved 01/01/2017 Summary of Products FL# Model,Number or Name Description 17022.1 1-"5V Crimp"(R6) 26 Gauge steel,3/8"rib height,24"wide lapped roof panel mechanically attached to Wood Deck with screws Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 1 5VCrimo 26ga WoodDeck EVALREPORT R6.odf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports i Other:Refer to evaluation report for conditions FL17022 R6 AE 1 5VCrimo 26aa WoodDeck EVALREPORT R6.odf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17022.2 2-"SV Crimp"(116) 0.032"Aluminum,3/8"Rib height,21"wider lapped roof panel, mechanically attached to wood deck with exposed screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 2 5VCrimo 032A1um Wo IdDeck EVALREPORT R6.odf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 2 5VCrimo 032A1um WoodDeck EVALREPORT R6.odf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17022.3 3-"1.5"Mechanical Seam" 1.5"rib height,16"wide,24 gauge steel,standing seam roof panel (115) mechanically attached to wood deck with clips and screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 3 1.5 MechSeam 24aa WoodDeck EVALREPORT.odf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 3 1.5 MechSeam 24aa WoodDeck EVALREPORT odf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. i 17022.4 4-"1.5"Mechanical Seam" 1.5"rib height,16"wide,0.032"aluminum;standing seam roof panel (RS) mechanically attached to wood deck with clips and screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 4 1.5 Approved for use outside HVHZ:Yes MechSeam 032A1um WoodDeck EVALREPORT.odf Impact Resistant:No Verified By:James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242 Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes Other:Refer to evaluation report for conditions Evaluation Reports and limitations of use.Install the assembly in FL17022 R6 AE 4 1.5 compliance with the installation method listed in MechSeam 032A1um WoodDeck EVALREPORT.pdf this report and applicable code sections of FBC. Created by Independent Third Party:Yes Refer to manufacturer's installation instructions as a supplemental guide for attachment. i 17022.5 5-"1 in.Nail Strip"(RS) 1"rib height,16"wide,26 gauge steel,standing seam roof panel mechanically attached to wood deck with screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 5 1NailStri6 26ga WoodDeck EVALREPORT.pdf Approved for use outside HVHZ:Yes Verified By:James L Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions I I and limitations of use.Install the assembly in FL17022 R6 AE 5 1NailStri12 26ga Wood eck EVALREPORT Ddf compliance with the installation method listed in Created by Independent Third Party:Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. i 17022.6 6-"1 in.Nail Strip"(RS) 1"rib height,16"wide,0.032"aluminum,standing seam roof-panel mechanically attached to wood deck with screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 6 1NailStrip 032A1um Wool dDeck EVALREPORT Ddf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 6 1NailStrip 032A1um WoodDeck EVALREPORT.odf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. I 17022.7 7-"1.5 in.Nail Strip"(R5) 1.5"rib height,19"wide,26 gauge steel,standing seam roof panel mechanically attached to wood deck with screws. Limits of Use Installation Instructions I Approved for use in HVHZ:No FL17022 R6 II 7 1.SNailStriD 26ga WoodDeck EVALREPORT.odf Approved for use outside HVHZ:Yes Verified By:James L Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 7 1.5NailStrio 26ga WoodDeck EVALREPORT.Ddf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. I I 17022.8 8-"EMAX Rib"(R5) 29 gauge steel,lapped roof panel mechanic i liy attached to wood deck with exposed screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 8 EMAX Rib 29ga WoodD ck EVALREPORT.odf Approved for use outside HVHZ:Yes Verified By:James L Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 8 EMAX Rib 29ga WoodDeck EVALREPORT.Ddf and limitations of use.Install the assembly in Created by Independent Third Party:Yes ! compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17022.9 T -"PBR MAX"(R5) 26 gauge steel,lapped roof panel mechanically attached to wood deck with exposed screws. Limits of Use Installation Instructions Approved for use in HVHZ:NO FL17022 R6 I1 9 PBR Rib 26ga WoodDel k EVALREPORT.Ddf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 9 PBR Rib 26ga WoodDeck EVALREPORT.odf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. I Back Next I I Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824I The State of Florida is an AA/EEO employer.Coovrieht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement I Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 8501487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If youl do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455,F.S.,please dick hem-. Product Approval Accepts: ®®® sLtxt i CBUCK Engineering Specialty Structural Enc2lneerinq CBUCK,Inc.Certificate of Authorization#8064 Evaluation Report "54 Crimp" Metal Roof Assembly Manufacturer: Extreme Metal Fabricators, LLC. 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 for Florida Product Approval ## FL 17022.1 R3 Florida Building Code 5th Edition (2014) Per Rule 61G20-3 Method: 1 - D Category: Roofing Sub - Category: Metal Roofing ! Product: 5-V Crimp Roof Panel, Material: Steel Panel Thickness: 26 gauge' Panel Width: 24" Support: Wood Deck Digitally signed by James L Buckner,P.E. Electronically signed and sealed documents shall comply with the provisions of FAC Rule Prepared by: 61G15-23 `XX11111111/,' ems!L. eUct ti James L. Buckner, P.E.,SECB � ��.••��cENs -' c�,p Florida Professional Engineer#31242 =*' No 31242 Florida Evaluation ANE ID: 1916 _ y� Project Manager:Youry Demosthenes tu= Report No. 15-217-5V-S6W-ER ;�.(� STATE OF :'2� ID (Revises 15-176-5V-S6W-ER) sS.FCO.... �;`� Date: 12/18/15 ''•,0NALe," t Contents: Evaluation Report Pages 1—7 �� v� 2015.12.1810:53:51 -05'00' CBUCK,Inc.,Palm Beach County,Florida Phone:(561)491-9927•Email:cbuck@cbuckinc.net-Website:www.cbuIckinc.net FL#: FL 17022.1 R3 Date: 12/18/15 CBUCK Engineering Report No.:2 of 27-SV-S6W-ER Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Manufacturer: Extreme Metal Fabricators,LLC. I Product Name: S-V Crimp Product Category: Roofing Product Sub-Category Metal Roofing Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) i Product/System 5-V Crimp Roof Panel, 26 gauge steel, 24" wide panel mechanically attached to Description: Wood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & Evaluated: standards: 1. Roof Panel 2. Fasteners 3. Underlayment 4. Insulation Board(Optional) Support: Type: Wood Deck (Design of support and.its attachment to support framing is outside the scope of this evaluation.) Description: • 15/32"or greater plywood, • or Wood plank(min.specific gravity of 0.42) Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable code sections and in accordan a with manufacturer's recommendations. Performance: Wind Uplift Resistance: • Design Uplift Pressure(ASD): Refer to Table A (Refer to"Table A" attachment details herein) I i i i FL#: FL 17022.1 R3 Date: 12/18/15 CSUCIK EnglneerinQ Page rt No.:3 - 77-5V-S6W-ER Specialty Structural Enginvering CBUCK,Inc.Certificate of Authorization#8064 Performance The product described herein has demonstrated compliance with: Standards: • UL580-06—Test for Uplift Resistance of Roof Assemblies • UL 1897-04—Uplift test for roof covering systems • TAS 125-03—Standard Requirements for Metal Roofing Systems Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 5th Edition (2014), Section 1504.3.2. 1 Evaluation Report This product evaluation is limited to compliance with the structural requirements Scope: of the Florida Building Code, as related to the scope{section to Florida Product Approval Rule 61G20-3.001. Limitations and . Scope of"Limitations and Conditions of Use"for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation methods) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval'. • Option for application outside"Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analiysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and-materials authorized in the+Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope Iof this evaluation and will be the responsibility of others. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade I Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA 1824). I I FL#: FL 17022.1 R3 Date: 12/18/15 g Page rt No.:4 of 77 5V-56W-ER CE3UCK Engineerin I Specldltty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 I Components/Materials Roof Panel: 5-V Crimp (by Manufacturer): Material: Steel Thickness: 26 gauge (min.) i Panel Widths: 24" (max.) Coverage Rib Height: 5/8" Yield Strength: 40 ksi min. Corrosion Resistance: Per FBC Section 1507.4.3 i ! Fastener: FASTENER 1 Used for Attachment Method 1 Type: Hex Washer Head Wood Screw Size: #9 x 1-1/2" (min.) Corrosion Resistance: Per FBC Section 1506.6 and�1507.4.4 Standard: Per ANSI/ASME B18.6.1 FASTENER 2 Used for Attachment Method 2,3 &4 Type: Hex Washer Head Wood Screw Size: #10 x 1-1/2"(min.) Corrosion Resistance: Per FBC Section 1506.6 and,1507.4.4 Standard: Per ANSI/ASME B18.6.1 I Components&Materials: Underlayment: (by Others) Material and application shall be in compliance with FBC Section 1507.4.5.1 and 1507.4.5.2, applicable codes and in accordapIce with manufacturer's recommendations. ' I Insulation(Optional): Type: Rigid Insulation Board Thickness: 3" (max.) Properties: Density: 2.25 pcf(Ibs/ft3) min. Or Compressive Strength: 20 psi min. Insulation Notes: • Rigid Insulation shall meet minimum density OR comp l Lsive strength. • Insulation shall comply with FBC Section 1508.When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". i ' I i ! • FL#: FL 17022.1 R3 Date: 12/18/15 CBUCKEn jneertn Report No.:5 of 7 -5V-S6W-ER ® g! ® q Page 5 of 7 Specidtty Structural emoneerinq 'CBUCK,Inc.Certificate of Authorization#8064 Installation: Installation Method: (Refer to"TABLE A"below and drawings at the end of tfiis evaluation report.) ■ Fastener Spacing: Refer to"TABLE A" Below (attached to the tops of the V's for a total of 3 scri ws across the width of the panel.) ■ Row Spacing: Refer to"TABLE A" Below (along the length of the panel) ■ Minimum fastener penetration thru bottom of support, 3/16". ■ For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE"A" ALLOWABLE LOADS METHOD 1: METHOD 2: METHOD 3: METHOD 4: Design Pressure(ASD)*: -86 PSF -93.5 PSF -101 PSF -228 PSF Row Spacing: 16"o.c. 16"o.c. 8"o.c. 6"o.c. Fastener Spacing(across panel width): 12"o.c. 12"o 1c. 12"O.C. 12"o.c. Fastener Size: #9 #10� #10 #10 I *Allowable design pressure(s)for allowable stress design(ASD)with a margin of safety of 2 to 1. Install the 5-V Crimp roof panel assembly in compl 1 iance with the installation method listed in this report and applicable code sections of FBC 5th Edition (2014). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: 1. UL 580-06 &UL 1897-04—Uplift Test By Architectural Testing, Inc. -West Palm Beach, FL (FBC Organization#TST ID: 1527) Report No.: D5893.01-450-18, Date: 05/02/14 Report No.: F3366.01-450-18, Date: 12/18/15 2. TAS 125—Uplift Test By Architectural Testing, Inc.-West Palm Beach, FL (FBC Organization#TST ID: 1527) Report No.: D5893.02-450-18, Date: 07/22/14 3. Quality Assurance Keystone Certifications, Inc.(FBC Organization ID#QUA 1824) Extreme Metal Fabricators, Inc. Licensee#974 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) I I FLi#: FL 17022.1 R3 Date: 12/18/15 CBUCK Engineering Pa port No.:6 - 17-5V-S6W-ER Speclall'y Structuresi Engineerinq CBUCK,Inc.Certificate of Authorization#8064 Installation Method Extreme Metal Fabricators, 5-V Crimp (26 gauge steel) Roof Panel attached to Wood Deck Drawings i 24" Maximum Net Coverage 5/8' i Panel Profile i Nomnai 1r o c. Nwinel 1r ma I Faelenem j NO x 1-1rZ Mn. or #10 x 1-1 i Min,perTli6ie W Fla Wtather Head Smow Panel Overlep Rdw to T&e W fbr Sp@MVAkwo panel Lero I i Dedc - IVJr or Greeter Plywood,ar - Wood Plank Typical Assembly Profile View (Typical Fastening Pattern Accross Width - Interior) i ssp FLU#: FL 17022.1 R3 Date: 12/18/15 CSUCK Enginserl Pagert No.:7 of 5V-S6W-ER eclalft j Structural EnQb'1QPrI1-IQ CBUCK,Inc.certificate of Authorization#8064 Installation Method t Extreme Metal Fabricators,,LLC. 5-V Crimp (26 gauge steel) Roof Panel attached to Wood Deck Fasteners- #9 x 1-1/2"Min. or #10 x 1-1/2"Min. per Table"A" 5-V Crimp Roof Panel Hex Washer Head Wood Screws Qj ,iti v� `vim I Deck: 15/32"or greater Plywood,or -Wood plank Typical Roof Assembly Isometric View (Optional) Rigid Insulation Board per Page 4 of this report TABLE"A" ALLOWABLE LOADS 1 METHOD 1: METHOD 2: METHOD 3: METHOD 4: Design Pressure(ASD)*: -86 PSF -93.5 PSF -101 PSF -228 PSF Row Spacing: 16"o.c. 16"o.c.' 8"o.c. 6"o.c. Fastener Spacing(across panel width): 12"o.c. 12"o.c. 12"o.c. 12"o.c. Fastener Size: #9 #10 #10 #10 i *Allowable design pressure(s)for allowable stress design(ASD)with a margin of safety of 2 to 1. i Table 201.1 are deemed to comply with the requirements of Section 507.2.2 3 11.3,of the 2004 Florida Budding Code,Existing Building. Board roof decking secured with at least two 8d nails into roof framing members shall be deemed to be sufficiently connected. Board roof decking secured with smaller fasteners than 8d nails or with fewer than two 8d nails per board shall be deemed sufficiently connected if two 8d clipped head,round head,or ring shank nails are in place on each framing member. Supplemental fasteners as required by Table'201.1 shall be 8d ring shank nails with round heads and the following minimum(fimensions: 1.0.113 inch nominal shank diameter" 2.Ring diameter of 0.012 over shank diameter 3. 16 to 20 rings per inch 4.0.280 inch full round head diameter 5.2-1/4 inch nail length i Table 201.1 Suplement Fasteners at Panel Edges and Intermediate Framing Existing Existing spacing Wind speed 110 mph Wind speed greater fasteners or less than I110 mph supplemental supplemental fastening shall be fastening shall be no geater than no eater than Staples or 6d An 6"o.c. 6"o.c. . 8d clipped head, 6"o.c.or less None necessary None necessary round head,or IjRg shank 8d clipped head Greater than 6"o.c a 6"o.c. or round head 6"o.c. 8d round head Greater than 6"o.c a 6"o.c a ring shank 6"O.C. a. Maximum spacing determined based on existing fasteners and supplemental fasteners. b. Maximum spacing determined based on supplemental fasteners only. 201.2 Roof secondary water barrier for site-built single family residential structures. A secondary water barrier shall be installed using one of the following methods when roofing replacement when reroofin& a) All joints in roof sheathing or decking shall be covered with a minimum 4 in.wide strip of self-adhering polymer modified bitumen tape applied directly to the sheathing or decking. The deck and self adhering polymer modified bitumen tape shall be covered with one of the underlayment systems approved for the parEicul Lr roof covering to be applied to the roof 2