NOTICE OF ACCEPTANCE MA) Vn►1.miamidade.Lo _v/economv
Interwrap,Inc. THESE PLANS AND ALL PROPOSED WORK
32923 Mission Way ARE TO ANY CORRECTIONS
8UBJECT
Mission,BC,Canada V2V-6E4 REQUIRED I3Y FIELD INSPECTORS THAT.
MAY I3E NECESSARY IN ORDER TO
SCOPE: COMPLY WITH ALL APPUCA13 CODES-
SCOPE:
NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where.allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control
Section(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)reserve the right to
have this product or material tested for quality assurance purposes.If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County.Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Titanium®UDL-25 PLUS,Titanium®UDL-30,Titanium'UDL-50,L'DL TT,UDL TF,
UDL TTMC-300,RhinoRoof U10,RhinoRoof U15,RhinoRoof U20,Ti_j um UDL25,and
RhinoRoof RSA Synthetic Underlayments
LABELING:Each unit shall_bear a permanent label with the manufacturer's name or logo,city,state and following
statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and th Ire has been no change
in the applicable building code negatively affecting the performance of this product
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, .
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami Dade County,Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer cr its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 13-0610.01 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
,•
4-0 603.18
wwwaoEcournYQ ��A1
� xpiYsfion Date: 08108118
j'9►-pproval Date: 06/11/15
Page 1 of 5
RhinoRoof UIS 42"x 286'rolls ASTM D226 . Woven"synthetic polymer underlayment with two
Manufacturing Type I and II sides coated with UV protected and slip resistant
Location #3 polymer stabilized polypropylene on both sides.
RhinoRoof U20 42"x 286'rolls ASTM D226 Woven synthetic polymer underlayment with two
Type I and 11 sides coated with UV protected and slip resistant
Manufacturing Location 0 1
polymer stabilized polypropylene on both sides.
TitamnmUDLZS 48"-x 250':iolIs: ASTM D226 Woven synthetic polymer underlayaicnt with two,
�1lanufacttirangLocaaon3 Type I and II sides coatedv�th UV prote cted ands
hp resistant"
polymer stabilized polypropylene on both sides;"
RhinoRoof RSA 36"x 67'rolls ASTM D1970 Unreinforced polymer mo&fied bitumen material
Manufacturing-Location#4 adhered to the underside of a polymer-coated,
synthetic woven sheet. The underside is backed
I
with a release film.
MANUFACTURING LOCATIONS:
1. MLl
2. ML2
3. ML3
4. ML4
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Reyort Date
Intertek Testing Services #3031783 TAS 104 02/19/03
3119607COQ-003B ICC-ES AC48 02/20/08
.3124826-01 ASTM El08 02/19/08
3124826=-007 ASTM E108 02/25/08
311801000Q-003 ASTM D226 02/20108'
3130639COO-002A ASTM D226 02/20/08
3146738COQ-003A ASTM D226 06/20/11
3146738COQ-003B ASTM D 1876/TAS 117 03/28/08
101465036COQ-001 ASTM D1970 06/27/14
100539395COQ-006 ASTM D226 06/02/14
101863861COQ-OOIA ASTM D226 10/28/14
10 1823107COQ-0 I I ASTM D226 12/09/14
Trinity ERD I15010.05.10 ASTM D4798/D226 05/14/10
138010.08.11 ASTM D226 08/11/11
135520.08.11 ASTM D2523/D1781 08/17/1.1
NOA No.:14-0603.18
Expiration Date: 09/08/18
Approval Date: 06/11/15
Paae 3 of 5
LIMITATIONS:
1. Fire.classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for
fire ratings of this product
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. Titaniure UDL-25 PLUS, Titaniure UDL-30, Titanium UDL-50, UDL TTMC-300, UDL TT, UDL TF,
RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhirioRoof RSA Synthetic
Underlayments shall be applied to a smooth,clean and dry surface with deck free of irregularities.All nails in
the deck shall be carefully checked for protruding heads. Re-fasten any loose decking;panels. Sweep the deck
thoroughly to remove any dust and debris prior to application. 1
4. Titaniumt UDL-25 PLUS, Titanium' UDL-30, Titaniurre UDL-50, UDL TTMC 300, UDL TT, UDL TF,
RhinoRoof U10, RhinoRoof UIS, RhinoRoof U20, Titanium UDL25, and RhittoRoof RSA Synthetic
Underlayments shall not be hot mopped,refer to manufacturer's published literature for product compatibility.
5. Titanium'* UDL-25 PLUS, Titanium* UDL-30, Titaniume UDL-50, UDL TTMC-300, UDL Tr, UDL TF,
RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic
Underlayments shall not be applied over an existing roof membrane as a recover syst*
6. Titaniums UDL-25. PLUS, Titanium' UDL 30, Titanium UDL-50, UDL TTMC 300, UDL TT,UDL TF,
RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, gad Rhino f RSA Synthetic
Underlayments shall not be left exposed as a temporary roof for longer than 30 days of application.
7. UDL TTMC-300 Synthetic Underlayment shall not be left exposed as a temporary roof for longer than I80
days of application.
8. Titanium® UDL-25 PLUS, Titanium's UDL-30, Titanium's UDL-50, UDL TTMC-300, UDL TT, UDL TF,
RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium .UDL25, and RhinoRoof RSA Synthetic
Underlayments are components used in roof system assemblies.Roof system assemblies are approved under a
specific Notice of Acceptance. Refer to Prepared Roofing system Product Control Notice of Acceptance for
listed approval of this product with specific prepared roofing products.
9. Titaniure UDL-25 PLUS, Titanium* UDL-30, Titanium" UDL-50, UDL TTMC-300, L'DL TT, UDL TF,
RhinoRoof Ul% RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic
Underlayments may be used with any approved roof covering Notice of Acceptance listing Titaniume UDL25
PLUS, Titaniume UDL_-30, Titanium UDL-50, UDL TTMC 300, UDL TT, UDL TF, RhinoRoof U10,
RhinoRoof U15, RhinoRoof U20, Titanium UDL25. and RhirioRoof RSA Synthe�c Underlayments as a
component part of an assembly in the Notice of Acceptance. If Titanium*UDL-25 PLUS,Titanium*'UDL-
30, Titanium's UDL 50, UDL TTMC-300,.UDL TT, UDL TF, RhinoRoof U10, oRoof U15,RhinoRoof
U20,Titanium UDL25,and RhinoRoof RSA Synthetic Underlayments-are not listed,ja request may be.made
to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for
approval provided that appropriate documentation is provided to, detail compatibility of the products, wind
uplift resistance,and fire testing results.
10. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo
and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County
Product Control Sea]as shown below.
' ro�EancEcot�rrY
11. All products listed herein shall have.a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20 3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
Hw�tnanaoot�rr
NOA No..14-0603.18
Expiration Date: 08/08/18
Approval Date: 06/11/15