Loading...
HomeMy WebLinkAboutNotice of Acceptance (2) REC ED SEP252017 mukm PERMITTING MIA MI-DADE COUNTY 1�'iIv St.Lucie County, FLPRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 111805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy i Polyglass USA Inc. 1111 W.Newport Center Drive Deerfield Beach,FL 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami=Dade-County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. J This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION'of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.14-0717.08 and consists of pages 1 through 8. The submitted.documentation was reviewed by Gaspar J Rodriguez. %jANOA No:: 15-0410.04 Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 1 of 8 MANUFACTURING PLANTS: - 1. Hazelton,PA 2. Winter Haven,FL EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Revort Date Trinity ERD P10870.09:08-R1 TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798&G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798&G155 09/01/11 P37300.10.11 TAS 11.0/ASTM D4798&D1970 10/19/11 P40390.08.12-2 ASTM D 1623 08/07/12 P37590.07.13-1 ASTM D6164 07/02/13 P45270..05.14 TAS 103,TAS 110&ASTM D1623 05/12/14 P46520.10.14 ASTM D1623 10/03/14 P44360.10.14 TAS 103&TAS 110 10/07/14 P43290.10.14 ASTM D 1970&TAS 110 10/17/14 PLYG-SC10130.06.16-3 TAS 103&TAS 110 06/21/16 PLYG-10130.06.16-1 ASTM D1970 &TAS 110 06/27/16 PRI Asphalt Technologies PUSA-035-02-01 TAS 103 09/29/06 PUSA-055-02-02 TAS 103 12/10/07 PUSA-089-02-01 TAS 103/ASTM D4798&G155 07/06/09 Momentum Technologies,Inc. JX201­17A TAS 103/ASTM D4798&G155 04/01/08 RX14E8A TAS 103/ASTM D4798&�G155 11/09/09 DX23138B TAS 103/ASTM D4798&IG155 02/18/10 DX23D8A TAS 103/ASTM D4798&IG155 02/18/10 LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city and state of manufacturing facility and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI.OIADE COUNTY ,...• s BUILDING PERMIT REQUIREMENTS: ' Application for building permit shall be accompanied by copies of the following: 1.This Notice of Acceptance. 2.Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 15-0410.04 °E C° Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 3 of 8 INSTALLATION REQUIREMENTS-i 1. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose deck panels,and sweep the deck thoroughly to remove any.dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS.l l l: 3. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum'lof 3'/2" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley,start at the Iow point and work to the high point,rolling the membrane from the.center outward in both directions. 5. For ridge applications,center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface,giving special attention to lap areas. 7. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6"piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. GENERAL LBUTATIONS: 1. Fire classification is not art of this acceptance. P P 2. Polystick Dual Pro,Polystick Tile Pro,Polystick TU Plus,Polystick MTS and Polystick MTS Plus may be used in asphaltic shingles,wood shakes and shingles,non-structural metal roofing,roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing. Polystick IR Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems. Polystick TU Max may be used in non-structural metal.roofing and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS and Polystick MTS Plus shall be applied to a smooth,clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU . Plus,Polystick.MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR Xe,Polystick Dual Pro,Polystick Tile Pro,.Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application.-Polyglass reserves the right to revise or alter product exposure.times; not to exceed the preceeding maximum time limitations. Ex osure Limitations a s MTS IR-Xe Elastoflex TU TU P Tile Pro Dual Pr`i TU Max MTS Plus S6 G Plus Winter Haven,FL 180 90 180 180 180 180 180 1 180 180 Hazelton,PA N/A 90 N/A 180 N/A N/A N/A 180 N/A NOA No.: 15-0410.04 aE[ Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 5 of 8 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,.Polystick MTS,Polystick HIS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe,Polystick Dual Pro, Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS Plus or,Elastoflex S6.G as a component part of an assembly in-the Notice of Acceptance. If Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G are not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products,winJ uplift resistance,and fire testing results. POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. . 2. All rolls,with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type,applied with,a minimum 1 %"metal disk as required in Miami-Dade County or simplex type nail as otherwise allowable in other regions,at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked"nail area,area para clavar"on the face of membrane,with the above stated nails and/or disks.The head lap membrane is to cover the area being back-nailed.(Please refer to applicable local building codes prior to installation.) 3. All seal lap seams(selvage laps)must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric;,and granule over granule end laps,shall have a 6" wide,uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement,Polyglass PG500 MB Flashing Cement,applied in between the application of the lap.The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlaymentS.Rlefer to the Polyglass Tile Loading Guidelines. See General Limitations#9 and#10. 6. Battens and/or Counter-battens,as required by the tile manufacturers NOA, must be used on all projects for pitch/slopes of 7"/12"or greater. It is suggested that on pitch/slopes in excess of 6 '/<"/12",precautions should be taken,such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation&before loading of roofing tiles is Forty-Eight(48)Hours. 8. Polystick membranes may not be used in any exposed application such as crickets,exposed valleys,or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,XtraFlex 50 Premium Modified Wet/Dry Cement,Polyglass PG500 MB Flashing Cement to the area in need of repair!followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair.Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. NOA No.: 15-0410.04 e � Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 7 of 8- EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION `26.GA.IMAGE II PANEL' RECEIVE® SEP 2 5 2817 PERMITTING FLORIDA BUILDING CODE 5T"EDITION(2014) St.Lucie County, FL FLORIDA PRODUCT APPROVAL FL 11560.5-112 ROOFING METAL ROOFING Prepared For: Metal Sales Manufacturing Corporation 545 South 3r,Street,Suite 200 Louisville,KY 40202 Telephone: (502)855-4300 Fax: (502) 8554290 Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer#62240 1216 N Lansing Ave.,Suite C Tulsa,OK 74106 Telephone: (918)492-5992 FAX: (866)366-1543 This report consists of . Evaluation Report(3 Pages including cover) Installation Details (1 Page) %%+`$.%gOCK,4tZJ# No 62240 Report No. C2009-5 STATE OF •.��/� Date: 3.27.15 ' O.�• ,off P • � �� �0e S .....••�C? till File Copy • FL 11560.57R2 C2009-5 3.27.15 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation .Product Name: Image II Panel Description: Max. 16" wide coverage with 1"high ribs Materials: Min. 26 ga., 50 ksi'steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel(ASTM A792)or painted steel(ASTM A755). Deck Description: Min. 19/32" plywood for new and existing constructions. Designed and installed as per FBC 2014. Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c. (Minimum) in the plywood field and edges Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1 Slope: 2:12 or greater in accordance with FBC 20.14 Section 1507.4.2 Design Uplift Pressure: 84.25 psf @ fastener spacing of 24" o.c. (Factor of Safety=2) 102.7 psf @ fastener spacing of 6" o.c. 139.1 psf @ fastener spacing of 6" o.c. with 3/8 bead adhesive in panel sidelap Fastener Pattern: At panel seam #10-12 pancake head screws along panel seam. Fastener shall be of sufficient length to penetrate through the deck a minimum of 1/a". Sidelap Adhesive: Schnee-Morehead SM7108 Permathane adhesive Test Standards: Roof assembly tested in. accordance .with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2014 Section 1507.4 Product Limitations: Design wind loads shall be determined;for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA for use of this product in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2014 Section 1505 'and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. i !� FL 11560.5-R2 C2009-5 3.27.15 Page 3 of 3 Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T241-07,Reporting Date 7/23/07 Hurricane Test Laboratory,LLC . HTL Report M 0103-0714-09,Reporting Date 9/1/09 es os wm: utc SEE DETAIL 1 MAX. 16" PANEL FASTENER aizv,e ROOF PANEL SPACING PER ALLOWABLE / PRESSURE TABLE. 3 . ................... 77" r IL PLYWOOD UNDERLAYMENT SHALL BE INSTALLED 8d x 2.5" LONG RING SHANK NAIL 19/32" THICK (MIN.) AS PER MANUFACTURER'S INSTALLATION: #GUIDELINES OR 8 x 2" LONG WOOD SCREWS MIN. 2X_ WOOD RAFTER/JOIST/ SPACED ® 6" O.C. IN THE FIELD & TRUSS AT MAX. 24" O.C. AT PLYWOOD EDGES FASTENING PATTERN 1 7004 SEE DETAIL 2 ADHESIVE IN THE MAX. 16" PANEL FASTENER ROOF PANEL —\� PANEL SIDELAP SPACING PER ALLOWABLE / PRESSURE TABLE. c4 0 �aoo Lo / UNDERLAYMENT SHALL BE INSTALLED 8d x 2.5" LONG RING SHANK NAIL 1IYWO IL 9/32�DTHICK (MIN.) AS PER MANUFACTURER'S INSTALLATION GUIDELINES OR x 2 #8 " LONG WOOD SCREWS �o � � OT MIN. 2X_ WOOD RAFTER/JOIST/ SPACED ® 6" O.C. IN THE FIELD & o0 TRUSS AT MAX. 24".O.C. AT PLYWOOD EDGES In FASTENING PATTERN 2 n TYPICAL PANEL INSTALLATION X—SECTIONS 14 MIN 26 GA. PANEL ALLOWABLE UPLIFT PRESSURE o #10-12 X 1" LONG FASTENING FASTENER ADHESIVE PRESSURE a. CL m PANCAKE SCREWS PATTERN SPACING BEAD SIZE (PSF) DETAIL AT MAX. 6" O.C. (IN) W A 1 24 NONE 94.2514 { 1 6 NONE 102.7 h N� UNDERLAYMENT PLYWOOD 19/32" THICK (MIN.) 2 6 3/8" 139.1 a —SIDELAP_ADHESIVE_M=_ •SIDEUP ADHESIVE IN THE PANEL SIOELAP NOM. 3/8" BEAD MIN 26 GA. PANEL #10-12 X 1" LONG GENERAL NOTES: PANCAKE SCREWS — 1.ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE AT MAX. 6" O.C. SIDEIAP ADHESIVE FLORIDA BUILDING CODE VC). DETAIL 2 LOCATION 2. ROOF PANELS SHALL BE IN. 26 GA (! = 0.0167'). MAX: EFFECTIVE COVERING WIDTH OF PANEL= 16. 3.THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING&STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS UNDERLAYMENT 5.ALL FASTENERARE GREATER S MUST BE N THE OWABLE WIND LOADS ACCORDANCE WITH THISECIFIED DRAWINGN&THIS THEDRAWING. FLORIDA DRAWING ND PLYWOOD BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM 2009-5 19/32" THICK (MIN.) REQUIREMENTS OF THIS DRAWING&THE CODE,THE CODE SHALL CONTROL 6. RAFTRS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS PACE NO. REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. 1 OF 1