Loading...
HomeMy WebLinkAboutProduct Approval RECEIVEAEP 25 2017 I� KUHN ENGINEE { 1 [STRUCTURAL F*Nr=1NE:F 1NE53 Certificate of Authorization #30464 1 Product Evaluation Report Min. 29 Ga. AG Roof Panel Over 15/32 Plywood Florida Product.Approval# 19041.1 Florida Building Code 2014 (5t"Edition) Per Rule 61G20-3 Method: 1-D =ME FASIENERS 4R ATTACHMM ARE THE RESMSULffy V THE Category: Roofing 0 3-7 2 Mad CTOROMMM) Subcategory:':Metal Roofing ST. LUCIE COUNTY BUILDING DIVISION Compliance Method:61G20-3.005(1)(d) REVIEWED Zone: Non HVHZ FOR COMPI. CE REVIEWED BY DATE I/^In "7 Product Manufacturer: PLANS AND PERMIT 1St Coast Metal Roofing Supply MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE 186."State Road 2o7 P.O. Box 177 - - East Palatka, FL 32131 Engineer Evaluator: %.�`P�1�Et- S• fr-U�,, Daniel S. Kuhn, P.E. �• �,1GE/V THESE PLANS AND ALL PROPOSED WORK Kuhn Engineering, LLC. ARE SUBJECT TO ANY COMPECTIONS FL PE#75519 *: No. 75519 REGURED W RRO INW-MAS THAT FL Evaluation ANE ID: 10743 MAY 01 NECE98ARY IN DER TO OVATE OF �Q 00MPI,Y WITH wwo-ARIX 00D6S, ? Validator: '�,�F.• < p R i o P.• ,�t�'': Locke Bowden, P.E., FL#49704 , S %` 9450 Alysbury Place �'�is�0(VAj_FN %t�� Montgomery,AL 36117 /0�28�2_o/S Contents: Evaluation Report: Pages 1-4 Py:.- f1 i IJ KUHN ENGINEERING Compliance Statement: The product as described in this report has demonstrated compliance with the FBC 2014(5`h Edition),Sec.1504.3.2 and 1504J. Product Description: AG.Roof panel, Min. 29 Ga.Steel, 36"Coverage,thro gh fastened roof panel over minimum 15/32" plywood decking. Non-structural application. Panel Material/Standards: Material: Minimum 29 Ga.,ASTM A792 Aluminum-zinc coated steel (Optional Paint Finish) Steel Grade: Min.Grade 80 Corrosion Resistance: Panel material shall comply with FBC 2014,Sec. 1507.43. Panel Dimension(s): Material Thickness: 29 Ga. Minimum Width: 36"'(Coverage) Rib Height: %" Major Rib at 9"01.c. Panel Seam: Lap sealant must be used for slopes less than 3:12 Panel.Rollformer: Cidan Machinery, Inc. Panel Fastener: #10-15 X 1-1/2" HiLo Woodgrip.w/sealer washer or pproved equal 1/4" minimum penetration through plywood. Corrosion Resistance: Per FBC 2014,'Sec. 1506.6 and 1507.4.4 Minimum Slope Range: Minimum slope 1/2:12 and shall comply with FBC 2014,Sec. 1507.4.2 and 1504.7,as well as in accordance with Manufacturer's recommendations. Underlayment.(Optional): Shall comply with Florida Building Code 2014,Sec. 1507.4.5.1 and 1507.4.5.2. Panel Substrate: Minimum 15/32" Plywood. Plywood Support: Roof framing must be spaced at 2Vo.c. maximum. Design of roof rafters/trusses, plywood, and plywood attachmentJnailing pattern are outside the scope of this report. Kuhn Engineering, LLC. 954.552.4500 FL#19041.1 www.KuhnEngineering.com info@KuhnEngineering.com Page 1 of 4 KUHN ENGIN.- EERINLz Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Installation: Install as per manufacturer's installation instructions and recommen ded details. Refer to Table"A" below for fastener pattern and spacing. Table"A" Maximum Total Uplift Design _78 5 psf" -108.5 psf* Pressures: Fastener Pattern: 9"-9,"-9":9" 6"-3" 6"-3"-6"-3"-6" Fastener Spacing(max.): 24"o.c. I 2404o.c. *Allowable(ASD)Design.Pressure Includes a;FS=2.0 Installation over Existing Shingles(Optional): AG panel may be installed over a single laver of existing roof shingles in accordance with the standards listed in FBC 2014,Section 1510.3. Attach panels directly over existing shingles and fasten into the decking material with a minimum 1/2" penetration through plywood.All five items listed under See. 1510.3 must be checked and i erified. Design Procedure: Based on the dimensions of the structure,appropria{a wind loads are determined using Chapter 16 of the FBC 2014 for roof cladding wind loads.These component wind loads for roof cladding are compared to the allowable pressures listed above.The design professional shall select the appropriate erection details to reference ip his drawings for proper fastener attachment to his stru d nalyze the panel fasteners for pullout and pullover.Su rmi u compliance with FBC 2014(5t'edition) ++!, .h , ,, LL Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the FBC,as relates to Rule 61G20-3.001. Limitations and Conditions of Use: 1. Scope of"Limitations and Conditions of use"fo I this evaluation: This evaluation report for"Optional Statewide Appri vats"contains technical documentation,specifications and installation method(s), which include"Limitations and Conditions of Use"throughout the Kuhn Engineering, LLC. 954.552.4500 FL#19041.1 www.KuhnE.ngineering.com info@Kuhhtngineering.com Page 2 of 4 KUHN . ENG r report in accordance with Rule 611320-3.005.Per RuleI61G20-3.004,the Florida Building Commission is the authority to.approv a products under "Optional Statewide Approval". 2. Option for application outside "Limitations and Conditions of Use": Rule 611320-3.005(1)allows engineering analysis for"project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code".Any modification of the product as evaluated in this repo j and approved by the Florida Building Commission is outside the scope lof this evaluation and will be the responsibility of others. 3. This product is not for use in the High Velocity HL rricane Zone sections. 1 1 Performance Standards: The product has been tested in accordance with: • UL 580-94—Test for Uplift resistance of Roof Assemblies— with Revisions through February 1998 • UL1897-98—Uplift Test for Roof Covering Systems Reference Data: Tests performed by Force Engineering&.Testing, Inc. (FBC Organization#TST-5328): • UL 1897-98-Uplift Test for,Roof Covering g Systems Test report No.384-0030T40A, B/593-00310T-10A, B. (Dated 03/29/10) j • FM 4471; Sec. 5.4 Foot Traffic Resistance Test Report.No.384-003OT-10E/593-0030T�10E (Dated 03/29/10) Certificate of Independence by: • Daniel S. Kuhn, P.E. (FL#75519) at Kuhn Engineering, LLC. (FBC Organization#ANE ID:,10743) Test Standard Equivalence: 1.-UL 580-94 test standard is equivalent to UL 580-06 test standard. 2. UL 1897-98 test standard is equivalent to UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established.compliance of roof panel products in accordance with the Florida Building Code and Rule i61G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Kuhn Engineering, LLC. 954.552.4500 FL#19041.1 www.KuhnEngineering.com info@KuhnEngineering.com Page 3 of 4