Loading...
HomeMy WebLinkAboutProduct Approval (2) 1 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 TRINITY ERD 353 CHRISTIAN STREET, UNIT QOOXFORD,CT 06478478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Tarco Roofing Evaluation Report 4930.02.14-112 One Information Way,Suite 225 FL16884-R2 Little Rock,AR 72202 Date of Issuance:02/27/2014 Revision 2:06/30/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaulated for compliance with the 5th Edition(2014) Florida Building Code sections noted herein. DESCRIPTION: LeakBarrier EasyLay UDL Synthetic Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance'Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(5) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user.,by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 3. Prepared by: 1�t[il[J[I/Jrry- y,:. v,- Robert J.M.Nieminen P.E. ••p� - The facsimile seal appearing was authorized by Robert Nieminen, j'.�t,S'• 'C?'��i 1� P.E.on 06/30/2015.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 �?G`�o^dQ\,a1- ta:Y;;: document.Signed,sealedhardcopies have been transmitted to the ',°�4++++ Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity)ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved.in the approval process of the product. - f 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. F I L-1� I I i QO;ITRkINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment i Compliance Statement: LeakBarrier EasyLay UDL Synthetic Roof Underlayments, as produced by Tarco Roofing, have demonstrated compliance with the intent of the following sections of the Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.3,1507.5.3,1507.7.3, Unrolling,Breaking Strength,Pliability, ASTM D226 2006 T1507.8,1507.8.3,1507.9.3, Loss on Heating i 1507.9.5 TAS 110 Accelerated Weathering TAS 110 j 2000 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) Physical Properties SC4950.02.14 02/27/2014 UL,LLC(QUA9625) Quality Control Service Confirm,10227624 Exp.02/20/2017 4. PRODUCT DESCRIPTION: f 4.1 LeakBarrier EasyLay UDL 15 consists of a woven-polymeric scrim with a textured fabric on the top surface. It is marketed as an alternate to ASTM D226,Type I or II felt. i 4.2 LeakBarrier EasyLay UDL Basic consists of a woven-polymeric scrim with a textured fabric on the top surface. It is marketed as an alternate to ASTM D226,Type II felt. 4.3 LeakBarrier EasyLay UDL 50 consists of a woven-polymeric scrim with a non-woven fabric on the top surface and a rubberized polymeric coating on the back surface. It is marketed as an alternate to ASTM D226,Type II felt. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory or test report from accredited testing agency for fire ratings of this product. 5.4 LeakBarrier EasyLay UDL Synthetic Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof'covering. 5.5 Allowable roof covers applied atop LeakBarrier EasyLay UDL Synthetic Roof Underlayments are as follows: TABLE 1: ROOF COVER OPTIONS! [I Underlayment Asphalt Wood Shakes& Nail-On Tile Foam-On Tile Metal Slate Shingles Shingles EasyLay UDL 15 Yes No No Yes I Yes Yes EasyLay UDL Basic Yes No No Yes Yes Yes EasyLay UDL 50 Yes No No Yes I Yes Yes COPY I I Exterior Research and Design,LLC. Evaluation Report 4930.02.14-R2 Certificate of Authorization#9503 FL16884-R2 Revision 2:06/30/2015 Page 2 of 3 f I i Q11" TRINITY I ERD 5.6 Exposure Limitations 5.6.1 LeakBarrier EasyLay UDL 15 shall not be left exposed for longer than 30=days after installation. 5.6.2 LeakBarrier EasyLay UDL Basic and LeakBarrier EasyLay UDL 50 shall not be left expo ed for longer than 180-days after installation. 6. INSTALLATION: 6.1 LeakBarrier EasyLay UDL Synthetic Roof Underlayments shall be installed in accordancelwith Tarco Roofing published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.1 LeakBarrier Easvlay UDL 15,UDL Basic or UDL 50: 6.1.1 Shall be installed in compliance with the requirements for ASTM D226,Type I or II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. i 6.1.2 For slopes 4:12(18.4°)or greater: LeakBarrier EasyLay UDL 15 shall be laid horizontally,parallel to the eave with the printed side up,flat and unwrinked and have minimum 4-inch side(horizontal)laps and minimum 8-inch end(vertical) laps. Side(horizontal) laps shall run with the flow of water in a shingling manner. End (vertical) laps shall be offset from course to course not less than 3 feet. 6.1.3 For slopes 2:12(9.4°)to<4:12(18.4°): LeakBarrier EasyLay UDL 15 shall be applied in a double coverage method, flat and unwrinkled. Begin by applying a 24 inch wide starter strip along the eaves. Then place a full-width sheet over the starter,with the lower edge flush to the starter's lower edge. Apply succeeding 48 finch wide courses up the roof slope, overlapping each previous course a minimum of 20-inches in a "shingle fashion with minimum 12-inch end (vertical)laps. End(vertical)laps shall be offset from course to course not less than 3 feet. 6.1.4 Where laps or joints require sealant or adhesive use plastic cement recommended by. arco Roofing. Tarco Roofing recommends sealing all laps and joints where the underlayment will be exposed to wind'Idriven rain. 6.1.5 Attachment: Use corrosion-resistant or stainless steel roofing nails with 3/8-inch diameter heads or low-profile plastic cap-nails with 1-inch diameter heads spaced 9-inch o.c. at all laps and 12-inch o.c. at two(2) staggered rows in the field of the sheet. If wind or rain is expected prior to finished roofing application,use 1-inch diameter plastic cap nails 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for information on plants covered under Rule 61, 20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: i UL,LLC.—QUA9625;(414)248-6409;karen.buchmann@ul.com I -END OF EVALUATION REPORT- I i I i i i Exterior Research and Design,U.C. Evaluation Report 4930.02.14-R2 Certif sate of Authorization#9503 FL16884-R2 Revision 2:06/30/2015 Page 3 of 3 I i