Loading...
HomeMy WebLinkAboutProduct Approval ,•�9/25/2017 V Florida Building Code Online -- Fix BCIS Home I Log In I User Registration Hot Topics Submit Surcharge l Stats&Facts I Publications FBC Staff B i Florida * Product Approval R E C E I v'E D S E P 2 5 2017 USER: Public User Product Approval Menu> Product or Application Search>Application List>Application Detail i t s" C=i =v FL# FL21383 Application Type New Code Version THFSL•PLANS AND ALL PROPOSED WORK 20114 Application St l SU-�T.OT TO ANY CM-f-G7100S Approved"����'.��FASTENERS 8��1�� RHOUIRED�sY FIEL0 I�.N-V.G Oft Tli� cb�4��d�� Comments MAY BE NECESSARY IN AI' F 7'f39 �- ��������P�NSI�I�flYYOF THE Archived COMPLY WITH APPWC..�LECODES, ��q�p��`�Y���eQe�,�,� Product Manufacturer Sunlast Metal Address/Phone/Email 2120 SW Poma Drive Palm City, FL 34990 (772) 223-4055 fivalidation@yahoo.com fl 97 Authorized Signat a ST. LUCIE COUNTY a Kapron BUILDING DIVISION fiva dation@yahoo.com REVIEWED F0OI3 !r®IY'1 OC Technical Represe ahWIEWED BY Add ress/Phone/E MATE D — PLANS AND PERMIT MUST BE KEPT ON JOB OR Quality Assurance eprfg0al1tl8%WTION WILL BE MADE Address/Phone/Email �,.. CA)p Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Arc Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed James Biagi the Evaluation Report Florida License PE-37467 F Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 03/02/2026 Validated By Locke Bowden i Validation Checklist - Hardcopy Received i Certificate of Independence FL21383 RO COI James Biagi.P.E. Certificate c I https://www.floridabuilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgve007nSKOaGOtHld%2bwQOEnpeB!KF3uZl OkWyizvE°/a2bvrg%3d°/a3d 1/3 9/25/2017 Florida Building Code Online Referenced Sta*d and Year (of Standard) Stam-rd UL 580 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/16/2016 Date Validated 12/16/2016 Date Pending FBC Approval 12/22/2016 Date Approved 02/07/2017 Summary of Products FL# Model, Number or Name Description 21383.1 ECONO LINE 1.0 CLIPLESS NAIL 26GA STEEL OVER 15/32" 4 PLY CD: STRIP Limits of Use Installation Instructions Approved for use in HVHZ: No FL21383 RO II ECONO LINE SERIF Approved for use outside HVHZ: Yes 26GA ss-Final.odf Impact Resistant: N/A Verified By: Architectural Testing, Ii Design Pressure: +n/a/-71PSF Created by Independent Third Part) Other: -71PSF @6"O.C. INSTALL PER MANUFACTURER'S Evaluation Reports DETAILS AND IN COMPLIANCE WITH FBC 2014. FL21383 RO AE ECONO LINE SERI 26GA ss-Final.odf Created by Independent Third Part) i 21383.2 ECONO LINE 1.0 NAIL STRIP ALUM .0321 ALUM OVER 15/32" 4-PLY CDX Limits of Use Installation Instructions Approved for use in HVHZ: No FL21383 RO II ECONO LINES SER Approved for use outside HVHZ: Yes ALUM ss.FINALpdf Impact Resistant: N/A Verified By: Architectural Testing, Ii Design Pressure: +N/A/-78PSF Created by Independent Third Part) Other: -78PSF @6"O.C. INSTALL PER MANUFACTURER'S Evaluation Reports DETAILS AND IN COMPLIANCE WI 20 4.. FL21383 RO AE ECONO LINES SEI *ZUJ MM ss.FINAL. df ted by Independent Third Part%t " )r 0 21383.3 ECONO LINE PBR 26GA STEEL OVER 15/32" 4-PLY CD Limits of Use Installation Instructions Approved for use in HVHZ: No FL211383 RO II ECONO LINE SERI[ Approved for use outside HVHZ: Yes Verified By: Architectural Testing, Ii Impact Resistant: N/A Created by Independent Third Part) Design Pressure: +N/A/-76.75 Evaluation Reports Other: -76.75PSF @ 24" O.C. Additional fastening for panel FL2,1383 RO AE ECONO LINE SERI overlaps @4"O.C. spacing Install per FBC 2014 and Created by Independent Third Part) manufacturer's details. Baci< tVt�;i https://www.floridabuilding.org/pr/pr app dti.aspx?param=wGEVXQwtDgve007nSK0aGOtHld%2bwQOEnpeBiKF---JQkWyizvE%2bvrg%3d%3d 2/3 i 9/25/2017 Florida Building Code Online Contact Us:: 2601 Blair Stone Road.TallahasseelFL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida. :I Privacy Statement:: Accessibility Stat Under Florida law,email addresses are public records.If you do not want your e-mail addrel s released in response to a public-reca mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.4; 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If y address,please provide the Department with an email address which can be made available to the public.To determine if you are; please click here Product Approval Accepts: Credit Card Safe FIL ' Clk"I I I i i https://www.floridabuilding.org/pr/pr app_dfl.aspx?param=wGEVXQwtDgve007nSKOaGOtHld%2bwQOEnpeB!KF3uzJQkWyizvE%2bvrg%3d%3d 3/3 I .,._5,.Un/ast Meta/ Palue Engineered Meta/Roofing Tm O . D , PRODUCTAPPROVAL E ONO LINE ( + LIPLE PIS NAP LOCK, L . } 26 ,GA 16"COVERAGE IIDTf-i R®OF PANEL 04ER 15/32":PLY:WO®® FLORIDA PRODUCT APPROVAL N0 21383 1 ,. - SERIEP Product Evaluation Report 1"[LIPLESS WAIL STRIP 26GA.Roof Panel over.l5/32"Plywood Florida:Product.Approval# 21383.1 Florida Building Code 2014 Per Rule 61G20-3 method:1—D Category:Roofing Subcategory:Metal Roofing Compliance Method: Rule 61G20-3 ` NON-HVHZ -Product Manufacturer: 7. Sunlast Metal 2120 SW Poma Drive Palm City,Florida 34990 Eneineer Evaluator James Biagi,P.E.FL#31467 1915-NE 45"'ST.#107 Fort Lauderdale,FL 33308 954- 176-8004F,. tF ` lup Vali ator• Locke Bowden,P.E:,FL#49704. 9450 Alysbury Place Montgomery,AL 36117 1�'�r o-�J ` •���EC:,cr VVl ��. Evaluation Report 1-4 ! James Biap.E.. FL# 46`3 C__ TAT r- OF ,���``ter,•.... �� (,w.�, Page 1 of 4 Compliance Statement:The product as described in this report has demonstrated compliance with the Florida Building Code 2014,Sections 1504.3.2,1507.4.3, Product Description:26GA Nail Strip/Snap Lock Metal Panel,16"Coverage Width,Roof panels,1.0 Rib height Panel restrained with#10 x 1"Pancake Head fasteners into 15/32"4 ply CDX Plywood decking. Non-structural Application. FOR USE IN NON-HVHZ. Material:26GA metal conforming to Florida Building Code 2014 Section 1507.4.3 Yield Strength:40KSI Corrosion Resistance:Panel Material shall comply with Florida Building Code 2014,Section 1506.6,1507.4.3,1507.4.4 Panel Dimensions:Panel Width:16"coverage width Fastener:#10 X 1"Pancake-Head wood fasteners or equivalent. Corrosion Resistant per Florida Building Code 2014 Section 1506.7. 3/16"minimum penetration through plywood Corrosion Resistance:Per Florida Building Code 2014,Section 1506.6, 1507.4.4 15/32"4ply CDX plywood,plywood supports at maximum 24'O.C.Design of plywood and plywood;supports are outside the scope of this evaluation.Must be designed in accordance w/Florida Building Code 2014. Design Uplift Pressures:Uplift Design Pressure:with Safety Factor of 2 TABLE A Max Design Pressure -71psf Field Fastener Spacing 6"from panel ends and 6"o.c. Fastener Size #10 Female leg of panel snap fit to the male leg of the adjacent panel. Quality Assurance:In accordance with FBC 2014 and Rule#61620-3:Keystone Certification, Inc.QUA 1824 Test References: I Architectural Testing Inc(TST 1527)#F8542.01-450-44 UL 580-06 Code Compliance:The product described herein demonstrated compliance with The Florida Building Code(FBC)2014 Section 1504.3.2.The product evaluation is limited to compliance with the structural wind load requirements of the FBC 2014,as relates to Rule 61G20-3. Minimum Slope Range 2/12 Minimum Slope per Florida Building Code 2014,and in accordance with Manufacturers recommendations. Installation:Install per manufacturer's recommended details in compliance with FBC 2014. Underlayment:Per Manufacturer's installation guidelines per Florida Building Code 2014 Roof Panel Fire Classification:No classification. FILE COFY Shear Diaphragm:values are outside the scope of this report. Design Procedure:Based on the dimensions of the structure,applicable wind loads are determined using Chapter 16 of the Florida Building Code 2014 for roof cladding wind loads.These component wind loads for roof claddi g are compared to the allowable pressure listed above.The design professional shall select the applicable erection details to reference in drawings for correct fastener attachment to his structure and analyze the panel fasteners for pullout and pullover)Support framing must be Page 2 of 4 i i compliant with Florida Building Code 2014 Chapter 22 for steel,Chapter 23 for wood and Chapter 16 for structural loading. Required wind loads shall be determined per project per FBC 2014 and any rational analysis computation shall be prepared by a licensed design professional. Certificate of Independence:James Biagi,P.E.does not have nor will acquire financial interest in any company manufacturing or distributing products under this evaluation.James Biagi,P.E.is not owned or operated or controlled by any company manufacturing or distributing product under this report. I I I i i f . PRODUCT EVALUATION REPORT i i C Page 3 of 4 i r 5 unlast Metal Value Engineered Meta/Roofing r"' ,FLO.R10A PRODUCT APPROVAL ECONO LINE (26GA CLIPLESS 1 .0 NAIL STOIP/SNAP LOCK) INSTALL DETAILS Fastener:#10 Pancake Head Wood Fastener Sunlast Econo 1" Clipless PANEL PROFILE O 0 1" Striations Optional �26 GAUGE 6 OC SCREW SPACING (Flat Shown) F1 Copvf Sunlast Econo 1 " Clipless PANEL PROFILE T 1" t � Striations Optional 26GAUGE (Flat Shown) Page 4 of 4