Entegra Roof Tile,LLC
1289 NE 9h Ave
Okeechobee,FL 34972
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product
or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION:Bella"high S"Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer,or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-1120.05 and consists of pages 1 through 5.
The submitted documentation was reviewed by Gaspar J Rodriguez.
MIAMI•DADECOUNTY FARCOPY2.06
Expiration Date:07/13/21
Approval Date:02/25/16
Page 1 of 5
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Roofing Tiles
Material: Concrete
Deck Type: Wood
1. SCOPE
This approves a roofmg system using Entegra Bella"High S"concrete roof tile as manufactured in Okeechobee,
FL and described in Section 2 of this Notice of Acceptance. For use in locations where,the pressure requirements,
as determined by applicable Building Code,do not exceed the design pressure values obtained by calculations in
compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be
prepared as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
Bella"High S" Length= 16 '/2" TAS 112 High profile,interlocking,extruded concrete roof tile
Width= 13-'/4" Type 2 equipped with two nail holes. For mechanical,mortar
Thickness= 'h" Class H or adhesive set applications.
Trim Pieces 1=varies TAS 112 Accessory trim,concrete roof pieces for use at hips,
w=varies rakes,ridges and valley terminations.
varying thickness
2.1 MANUFACTURING LOCATION
1. Okeechobee,FL
2.2 EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
The Center for Applied Engineering, 25-7094-(3, 6& 9) Static Uplift Testing Oct. 1994
Inc. TAS 102
The Center for Applied Engineering, 25-7120-(1 &2) Static Uplift Testing Nov. 1994
Inc. TAS 102
The Center for Applied Engineering, 25-7183-(3 &4) Static Uplift Testing Feb. 1995
Inc. TAS 102
The Center for Applied Engineering, 25-7214-(3,4,&7) Static Uplift Testing March, 1995
Inc. TAS 102
The Center for Applied Engineering, 25-7804-4 Static Uplift Testing Sep. 1996
Inc. TAS 102
Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998
Testing Services TAS 101
Celotex Corporation 520191-2-1 Static Uplift Testing March 1999
Testing Services TAS 101
Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999
NOA No.: 16-0112.06
MIAMI•DADE COUNTY Expiration Date:07/13/21
Approval Date: 02/25/16
Page 2 of 5
2.2 EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Reuort Date
Walker Engineering,Inc. Calculations Restoring Moment June 2007
IBA Consultants,Inc. 2421-94 ASTM C 1167 June 2006
American Test Lab of South Florida RT1210.03-15 TAS 112-95 Dec 2015
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications,a static field uplift test in accordance with TAS 106 may be
required,refer to applicable building code.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112,appendix`A'. Such testing shall be submitted to the Miami-Dade Product
Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
4. INSTALLATION
4.1 Entegra Sales, Inc.'s Bella "High S" concrete roof tile and its components shall be installed in strict
compliance with Roofing Application Standard RAS 118,RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
I
Table 1: Average Weight (W) and Dimensions (I x w)
Tile Profile Weight-W(lbf) Length-I (ft) Width-w (ft)
Bella "High S"Tile 10.5 1.375 j 1.08
I
Table 2: Aerodynamic Multipliers -A (ft3)
Tile A (ft3) A (ft3)
Profile Batten Application Direct Deck Application
Bella "High S"Tile 0.349 0.378
Table 3: Restoring Moments due to Gravity- M9 (ft-lbf)
Tile 211:12" 3":12" 4":12" 5":12" 6"1211 Greater than
Profile 7":12"
Bella"High Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
S"Tile Deck Deck Deck Deck Deck Deck
6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13
NOA No.: 16-0112.06
MIAMI•DAD,COUNTY Expiration Date: 07/13/21
Approval Date:02/25/16
Page 3 of 5
Table 4: Attachment Resistance Expressed as a Moment-Mf(ft-lbf)
for Nail-On Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" plywood) (min. 19/32" plywood)
Bella "High 2-10d Ring Shank Nails 28.6 41.2 19.4
S"Tile 1-10d Smooth or Screw 5.1 6.8 2.8
Shank Nail
2-10d Smooth or Screw 6.9 9.2 7.3
Shank Nails
1 #8 Screw 20.7 20.7 18.1
2#8 Screw 43.2 43.2 29.8
1-10d Smooth or Screw 23.1 23.1 19.0
Shank Nail Field Clip)
1-10d Smooth or Screw 29.3 29.3 24.0
Shank Nail Eave Clip)
2-10d Smooth or Screw 27.6 27.6 38.6
Shank Nails Field Clip)
2-10d Smooth or Screw 38.1 38.1 41.8
Shank Nails Eave Clip)
2-10d Ring Shank Nails' 33.1 48.1 50.9
1. Installation with a 4"the headlap and fasterners are located a min. of 2'/2"from head of tile.
I
Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf)
for Two Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Bella "High S"Tile Adhesive 29.32
1 See manufactures component approval for installation requirements.
2 Flexible Products Company TileBond Average weight per patty 10.7 grams.
3M-2-Component Foam Roof Tile Adhesive AH-160 Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment -Mf'(ft-lbf)
for Single Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Bella"High S"Tile 3M' 2-Component Foam Roof Tile Adhesive AH-160 66.53
3M' 2-Component Foam Roof Tile Adhesive AH-160 38.74
3 Large patty placement of 63 rams of 3W 2-Component Foam Roof Tile Adhesive AH-16,0.
4 Medium patty placement of 24 rams of 3M' 2-Component Foam Roof Tile Adhesive AH-1160.
Table 7: Attachment Resistance Expressed as a Moment -Mf(ft-lbf)
for Mortar Set Systems
Tile Profile Tile Application Attachment Resistance
Bella"High S"Tile Mortar Sets 24.5
5 Tile-Tite Roof Tile Mortar.
NOA No.: 16-0112.06
=MIAMIk-DADE COUNTY Expiration Date:07/13/21
Approval Date:02/25/16
Page 4 of 5
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen in detail
below, or following statement: "Miami-Dade County Product Control Approved"1.
OR
7��7
ENTEIRRR
ENTEGRA SALES BELLA"HIGH S"CONCRETE TILE LABEL
(LOCATED UNDERNEATH TILE)
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or the applicable Building Code in order to properly evaluate the
installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit.
PROFILE DRAWING
I
2
END OF THIS ACCEPTANCE
NOA No.: 16-0112.06
MIAMI•DAD;COUNTY Expiration Date:07/13/21
Approval Date:02/25/16
Page 5 of 5
I