Loading...
HomeMy WebLinkAboutAPPROVED ENERGY CALCS & MANUAL J - 14351 AMAPOLA(1)FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St_ Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$1432.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insuf, Exterior R=4.1 1224.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 208,00 ft2 c. NIA R= ft2 4. Number of Bedrooms 3 d. NIA R= ft2 5. Is this a worst case? Yes 11. Ceiling Types (1783.0 sqft.) Insulation Area 6. Conditioned floor area above grade (ft2) 1753 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 1753.00 ft2 R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Windows(151.4 sqft.) Description Area 12. Ducts R ft2 a. U-Factor. Sgl, U=1.02 111.36 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 195 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 SHGC: 13. Cooling systems kBtulhr Efficiency SHGC=0.27 c. U-Factor: NIA a. Central Unit 34.8 SEER:15.00 ft2 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. 14. Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.285 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor(AVG) NIA ft2 SHGC(AVG): NIA 15. Hot water systems 9. Floor Types (1753.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features EF: 0.970 b. NIA R= ft2 None c. NIA R= ft2 16. Credits None Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49.38 Total Baseline Loads: 50.69 PASS I hereby certify that the plans and specifications covered by are in compliance Review of the plans and Cadcalculation with the Florida Energy specifications covered by this calculation indicates compliance PREPARED BY: with the Florida Energy Code. DATE: 1-12-20121 Before construction is completed this building will be inspected for f compliance with Section 553.908 W hereby certify that this building, as designed, is in compliance Florida Statutes. * with the Florida Energy Code. `S +00 W's E RI�NT: BUILDING OFFICIAL: DAT_ DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure certified factory -sealed in accordance with R403.3.2.1. qualifies as - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). this project requires an 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angie: 180 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 W 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 If ___ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft- 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft' -__ 0 1 0 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INF'U 15UMMAKY GHtGKL15I KCPUKI FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft' — 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft' _ 0 1 0 8Slab-On-Grade Edge Insulatio KITCHEN 11 ft 0 209 fP _ 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft' _ 0 1 0 10SIab-On-Grade Edge Insulatio HALL t ft 0 25 ft- — 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 It 0 92 ft' _ 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft. -_ 0 1 0 ROOF Roof Gable Roof Red Solar $A Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft' 0 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft- N N CEILING # Ceiling Type Space R-Value Ins Type . Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft' 0.1 Wood _ 2 Under Attic (Vented) WIC 30 Blown 63 fP 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 fN 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft- 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 it- 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 fY 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 fF 0.1 Wood _ 9 Under Attic (Vented) BATH 30 Blown 50 ft' 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft- 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 fY 0.1 Wood 13 Knee Wall (Vented) DINING/GREAT 19 Blown 30 ft- 0.11 Wood WALLS Adjacent Space Cavity Wig Height Sheathing Framing Solar Below 0 1 NE=>SW Exterior Concrete Block - Int InsMASTER BE 4.1 16 0 8 0 128.0 ft` 0 0 0.3 0 2 SW=>NE Exterior Concrete Block- Int InsMASTER BE 4.1 7 0 8 0 56.0 ft' 0 0 0.3 0 3 NW=>SE Exterior Concrete Block - Int InSWASTER BE 4.1 14 0 8 0 112.0 ft' 0 0 0.3 0 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHFrKI IST RFPART WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 4 NE=>SW Exterior Concrete Block - Int Ins&IIASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 5 NE=>SW Exterior Concrete Block - Int Insul M. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 6 NE=>SW Exterior Concrete Block - Int InSBIEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 7 SW=>NE Exterior Concrete Block - Int InsaINING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.3 0 8 NW=>SE Exterior Concrete Block - Int InsaINING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.3 0 9 SW=>NE Exterior Concrete Block - Int InsulKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 _ 10 NE=>SW Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 11 SE=>NW Exterior Concrete Block - Int Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 12 SW=>NE Exterior Concrete Block - Int Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 13 NE=>SW Exterior Concrete Block - Int InsElEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 14 SW=>NE Exterior Concrete Block - Int InsENEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 15 N=>S Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated FOYER None .39 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.02 0.29 Y 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>SW 5 Metal Low-E Single Yes 1.02 0.29 Y 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 NE=>SW 6 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft2 1 ft 0 in 1 ft 4 in None None 4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29 Y 39.8 ft2 1 ft 0 in 1 ft 4 in None None 5 NW=>SE 8 Metal Low-E Single Yes 1.11 0.27 Y 40.0 ft2 8 ft 0 in 1 ft 4 in None None 6 NE=>SW 13 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION Method SLA CFM50 ELA EWhSclhpouse EgLA ACH ACH 50 Proposed ACH(50) .000254 1168.7 64.12 120.37 .0902 5 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing[ SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cent # Company Name System Model # Collector Model # Area Volume FEF None None ft, DUCTS — supply— — Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 195 ft2 Attic 55 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [) Jan [ ] Feb Heating EX]) Jan EX)1 Feb [ ] Mar Mar Apr Apr (7() [X] May [ 7 Jun Jun ] Jul Aug Sep r Oct Nov Nov Dec Dec VenOct ting Jan Feb ILXxJJ Mar May I 1 Jun E 1 Jul AuSep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.fL 0 ft2 0 ft 0.3 MASTER BEDROO Defautl(8 lbs/sq.ft. ft2 ft 0.3 WIC Defaults lbs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft2 ft 0.3 M. BATH Default(8 lbs/sq.fL ft2 it 0.3 LAUDRY Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 DINING/GREATR Default(8 lbs/sq.ft. ft2 ft 0.3 KITC:HFN 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. ft. it 0.3 BATH Default(8 lbs/sq.ft. ft' It 0.3 HALL Default(8 lbs/sq.ft. ft= it 0.3 FOYER Default(8 Ibs/s .ft. ft' ft 0.3 BEDROOM 3 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRe$2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL Permit Number: Y Owner: Jurisdiction: w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceilin soffit 9/ Yair the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed, per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned Spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids ,,, auV-VJI, I.JQVUVUVII V i rvg wanes audu uc III du:umduce wLLn me Provisions Or IuuY UU. 1/12/2021 1:15 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft= b. Frame - Wood, Adjacent R=11.0 208.00 ft- 3. Number of units, if multiple family 1 c N/A R= ft 4. Number of Bedrooms 3 d. N/A R= ft= 5. Is this a worst rase? Yes 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft- 6. Conditioned Floor area (fl=) 1753 b. Knee Wall (Vented) R=19.0 30.00 ft= 7. Windows" Description Area c. N/A R= ft' a. U-Factor. Sgl, U=1.02 111.36 ft= 12. Ducts, location & insulation level R ffz SHGC: SHGC=0.29 a. Sup: Attic, Ret: Attic, AH: Attic 6 195 b. U-Factor. Sgl, U=1.11 40.00 ft= SHGC: SHGC=0.27 13. Cooling systems kBtu/hr Efficiency c. U-Factor: WA ft= a. Central Unit 34.8 SEER:15.00 SHGC: d U-FaWA SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.850 ft a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.285 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): WA ft= a. Electric Cap: 40 gallons SHGC(AVG): N/A EF: 0.97 9. Floor Types Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft= None b. N/A R= it, Credits (Performance method) None c. N/A R= fP I certify that this home has complied with the Florida Energy Efficiency Cade for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: iy�j`j �.tv�c{ ���{ City/FL Zip: 7 e c *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 wrightsoft® Project Summary Entire House BY QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKC4LCS@AOL.COM Project Information For. WYNNE DEVELOPMENT THE W INDSOR, FT. PIERCE, FL Notes: Design Information Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db Inside db 70 OF Inside db 75 °F Design TD 28 OF Design TO 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21542 Btuh Structure 16420 Btuh Ducts 6191 Central vent (0 cfm) 0 Btuh Btuh Duds Central vent (0 clim) 9337 Btuh 0 Btuh (none) e) 0 Btuh Blower 0 Btuh Pi In Equipment load 27734 Btuh Use manufacturers data n Infiltration Rate/swingg multipplier Equipmentsensibleload 0.95 24470 Btuh Method Simplified Construction quality Average Latent Cooling Equipment Load Sizing Fireplaces 0 Structure 2495 Btuh Duds 2546 Btuh Central vent (0 c1m) 0 Btuh Heatingg Area Coolingg (none) (ft2) 1753 Volume (ft') 16478 1753 16478 Equipment latent load 6041 Btuh Airchanges/hour 0.38 Equiv.AVF (dm) 104 0.20 55 Equipment Total Load (Sen+Lat) 29511 Btuh Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A 030 Cond 25HBC536A 030 AHRI ref 7914585 Coil FX4DN(B,F)037 Efficiency 8.5 HSPF AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Heating input Heating output 34600 Btuh@47°F Sensiblecooling Latent000ling 24360 Btuh 10440 Btuh Temperature rise 27 Actual air flow 1160 OF clam Total cooling Actual air flow 34800 Btuh 1160 cfirl Airflowfador Static 0.042 pressure 0 dm/Btuh in H2O Airflowfador Static 0.045 dhvBtuh Space thermostat pressure Load sensible heat ratio 0 in H2O 0.84 Capacity balance point = 36 OF Backup: Input=7kW, Output =23009 Btuh. 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wr7gh*s ft— 202t-Jan1213:18:18 RigftSUte6l Unwrsal 201919.021 RSU08101 ...DOa rtslWdglts ftWAGWYNNE-THE WINDSORn Calc=M18 FrOMDuorfaces: N Page i }► wrightsofr Right,J® Worksheet Job., Entire House Date: QUICK CALCS, INC. By. 317 ST.. LUCIE LN., Fr. PIERCE, FL 34946 Phore: 772-466-6799 Faz 77246"796 Emil: QUICKCALCS AOL.COM 1 Room name Entire House BEDROOM 2 E-cosedwalI 207.6 ft 41D It 3 Room height 9.4 ft d 9.4 ft heatl000l 4 Room dimensions 14.0 x 20.0 f 5 Room area 1753.0 ft' 280.0 ft' Ty Construrbon U-value Or HTM Area Load Area number (BWhfiF-°F) (ev or perimeter (ft) (Btih) or perimeetter (ft) (BWh) Heat Cool Grose NIPS Heat Cool Gras N/PS Heat Cool 6 13A4o s 0.143 n 4.00 2.55 649 596 2386 1517 66 66 263 167 1Aatom 1270 n 3556 34.77 15 0 533 522 0 0 0 - 0 4A5-2om 0.770 n 21.56 1931 38 0 815 730 0 0 0 0 W 13A4os 0.143 ne 4.00 2.55 27 27 106 68 0 0 0 0 7 t 13A = 0.143 a 4.00 2.55 141 100 400 255 0 0 0 0 IAcIom 1270 a 3556 97.06 20 1 711 1741 0 0 0 0 71DO 0.390 a 10s2 1131 21 21 229 238 0 0 0 0 W 13A-4cce 0.143 se 4.00 2.55 27 27 106 68 0 0 0 0 Yt/ 13A-4ws 0.143 s 4.00 2.55 536 530 2121 1349 188 188 753 479 �C 1Aaiom 1270 s 3556 34.77 6 6 213 209 0 0 0 0 13A-4= 0.143 w 4.00 255 320 255 1022 649 132 108 432 275 IA-c1om 1270 w 35.56 54.53 12 1 415 636 12 1 415 636 1A,c1om 1270 w 35.56 54.531 12 1 427 654 12 1 427 654 4A5-2om 0.770 w 21.56 45.63 41 2 880 1862 0 0 0 0 P 12C-O v 0.091 - 2,55 128 254 254 647 326 0 0 0 0 C 16AJOmd 0.032 0.90 2. 1753 1753 1571 4067 280 280 251 650 F 22A-tpi 0.989 - 27.69 0.00 1753 208 5748 0 280 41 1135 0 6 C)AED e=irsion 488 Ernelope loss/gain 18331 0230 3676 3349 12 a) InfiltrWon 3211 729 205 b) Room ventilation 0 0 0 13 Intemal gains: Oavpan6@ 230 t 0 0 Aoplianoadother 0 Subbtal(lines6 to 13) 21542 16420 1 4405 3554 LesseMemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal', 21542 16420 4 75 DUCioads 29% 57% 6791 9337 29% 57% 1266 266 2021 2021 Total room load 27734 25751 5671 5575 Air required (Qm) 1160 1160 237 251 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed .ri'LPs -rw wWSWIIV APoft- Rigtt.Suta@ Uriversel 201919.021 RSU08101 2021- larF1213:18:18 ...Do rtslWdgttoft HUAC\WYNNE-THEWINDSORnq CaIc=WB Frord Doorfdces: N Page wrightsofr Right-M Worksheet Job: Entire House Date'` QUICK CALCS, INC. BY 317 ST. LUCIE LN.,FF.. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Emil: QUiCKCALCS@AOL.COM 1 I Room name WIC MASTER BATH 2 Dposedwall 0 ft 9D It 3 Room height 9A It heaV000l 9.4 It heatlmol 4 Room dimensions 7.0 x 9.0 ft 7.0 x 9.0 it 5 Room area 63.0 fF 63.0 IF Ty Constructor, U-value Cr HTM Area ( Load Area (if) Load number (Bluh4F--°F) (BLI MF) or perimeter (ft) (Btlh) or perimeter (ft) (Bluh) Heat Cool Gros NIPS Heat Cool Gross NIPS Heat Cool 6 y/ 13A-0ors 0.743 n 4.00 2.55 0 0 0 0 0 0 0 0 {�-GC 1Aalom 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 W 13A4ors 0.143 ne 4.00 255 0 0 0 0 0 0 0 0 11 13A4= 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 F-C 1Aclom 1270 a 35.56 87.06 0 0 0 0 0 0 0 0 �D 11DO 00% a 10.92 11.31 0 0 0 0 00 0 0 IN4ocs 13A 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 V}/ I13A4ors 0.143 a 4A0 2S5 0 00 0 85 85 339 215 -G 1Ac1om 1270 s 3556 34n 0 0 0 0 0 0 0 0 13A4o s 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1A-clam 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 tAclom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 4AS2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P 12C-0sv 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 63 63 56 146 63 63 56 146 F 22A-tpl 0989 - 27.69 0.00 63 0 0 0 63 9 249 - 0 6 c)AEDe rion -10 ErwalopeioWgain 56 136 644 12 a) Infiltrator, 0 0 160 b) Roomlentlaton 0 1334 0 0 13 IMemalgains: Oaupan5@ 230 p p p ApPlianceslother p Subtotal(Ilnes6t)13) 56 136 804 379 Les external load 0 0 Lestrarder 0 0 0 0 RedistibWon 0 0 0 0 0 14 Subtotal 56 136 831 0 379 15 DUQloads 29% 57% 16 77 29% 57% 231 216 Total loom load 73 214 1043 95 527 Air required(c1m) 3 10 43 27 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed - wrlghisoTC- 2021-Jan-1213:18:18 A RigI1Sute®Unversa1201919.021 RSUC8101 Page2 ...Downers\Wngtiroft HVACWYNNE-THEWINDSORAp Calc=M18 FrontDoorfaces:N -1� wrightsoft° RighW@ Worksheet °yDat Entire House QUICKCALCS, INC. ey. 317 ST. LUC12 LN., Fr. PIERCE, FL 34946 Phone: 772466-6799 Fax: 772-466-6796 Emit: OUICKCALCS@AOL.COM 1 Room name PABATH KITCHEN 2 ExoosEdvrall 8.0 ft 8.0 ft 3 Room height 9.4 ft heat/ocol 9A ft heati:ool 4 Room dimensions 7.0 x 8.0 ft 1A x 172A ft 5 Room area 56.0 T 172.0 ff Ty Construction U-value Or HTM Area Load Area number (BWh4l=-°F) (BWh41� or perimeter (ft) (Btuh) or perimeter (ft) (Bhlh) Heat Cool Gras NIPS Heat Cool Gras NIPS Heat Cool 6 vr! 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 II--G 1Aclom 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 G13A4ors 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 W 13A-4ors 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 IN 13AAo s 0.143 a 4A0 2.55 0 0 0 0 0 0 0 0 1-G Ural= 1270 a 35.56 87.06 0 0 0 0 0 0 0 0 I-D 11DO 0.3% a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4o s 0.143 se 4.00 2,55 0 0 0 0 0 0 0 0 W 13Aslors 0.143 s 4.00 255 75 69 277 176 0 0 0 0 Y-G 1Aclom 1270 s 351% 34.77 6 6 213 209 0 0 0 0 moors 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 to-ctom 1270 w 35.56 54,53 0 0 0 0 0 0 0 0 1Actom 1270 w 35.56 5453 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 215% 45.63 0 0 0 0 0 0 0 0 P QUON 0.091 - 2.55 128 0 0 0 0 75 75 192 96 C 16A-30md 0.032 - OR) 2.32 56 56 50 130 172 172 154 399 F 22A-gl 0.989 - 27.69 0.00 56 8 222 0 172 8 222 0 6 c)AEDenvrson -34 Envelope lostgain j 762 477 567 462 12 a) Infiltration 142 40 0 0 b) Roomy rdiaffon 0 0 0 0 13 Internal gains: Oavpanls@ 230 0 0 0 0 Appliances(other 0 0 Subtotal Illness to 13) 904 517 567 462 lesexemalload 0 0 0 0 Letransler s 0 0 0 0 Redistribution 0 0 0 14 Subblal 904 517 560 6 15 Duct lows 29% 57% 260 294 29% 57% 163 263 Total loom load 1 1164 811 725 Airrequired(cim) 49 37 31 33 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed Zre- FagltSut Uriversa1201919.021 RSU08101 2021Jan121318tl8 ...Doarnerts\WdgHvoftHUADWV NE-THEWINOSOPn Catc=NW FrortDoorfaces: N Page 1 wrightsoft• Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST LUCIE LN., FT. PIERCE, FL 34946 PFore: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@4OL.COM 1 Room name BATH SEDROOM2 2 Bposed wall 5.0 It 42.6 It 3 Room heigIr 1 9.4 ft heaVcool 9.4 It heat(=[ 4 Roomdimensors 9.0 x 5A a 1A x 204A It 5 Room area 45.0 iF 204.0 ft Ty Construction U-Malue Or HTM Area Load number (Bhrh/tt'-°Fj (BWhfiF) or perimeter (ft) (BNh) oorperimeteter (ft) (Bluh) Heat Cool Gros N/P/S Heat Cool Gross N/P/S Heat Cool 6 V[13AA= 0.143 n 4.01C 2.55 47 47 188 120 132 132 527 335 _-GG 1Ac1om 1270 n 3556 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 W 13A4oa 0.143 ne 4.00 2.55 0 0 0 0 27 27 106 68 11 16 13A4oa 0.143 a 4.00 2.55 0 0 0 0 85 65 259 164 1Ac1om 1270 a 35M 87.06 0 0 0 0 20 1 711 1741 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 D w 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 27 27 106 68 Vil �G 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 132 132 527 335 1Aciom 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A4o s 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 IA-dom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 1Actom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P 12C-O r 0.091 - 2,55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 45 45 40 104 204 204 183 473 F 22A-tpI 0289 - 27.69 0.00 45 5 138 0 204 43 1179 0 6 c)A rson -17 -99 Ernelope sslgain ooelo 367 207 3599 3085 12 a) Infiltration 89 25 b) Rcomventla4on 0 758 214 0 0 0 13 Intm lgains Oaupants@ 230 0 0 0 Applianres/olher 0 0 0 Subto4l(lines6to13) 456 232 4357 3299 Lesextamalload 0 0 Lestransrer 0 0 0 0 Redistibut, 0 0 14 15 Subtotal DuHioads 456 230 0 4357 0 3299 29% 57% 131 132 29% SM 1252 1876 Total room bad Air required(cfm) 567 w 5609 5175 25 i6 235 233 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed - wragtiCaof!- .Rigti321RSU08101 2021-JarF1213:18:IS ..�mr6\WngrfsoftHJACiWYNNE-1}EWIND5ORxLp Calc=M18 FrorGDoorfacesN Page ! wrightsoft RighWO Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Piro.: 772466-6799 Fa 7 2C66-6796 Emil: OUICKCALCS@AOLCOM 1 Room name ENTRY LAUNDRY 2 Exoosedvall 18A ft 13.0 It 3 Room heiglra 9.4 It heaV000l 9.4 ft heatl000l 4 Room dimensa.-s 1.0 x 92.0 ft 7.0 x 6.0 It 5 Room area 92.0 fF 42.0 tF Ty Constructon U-value Or HTM Area Load (T) Load number (BWh%F-'g (Bhlhdg or perim� (ft) (BWh) oorperimeter (ft) (Btuh) Heat Cool Gros NIPS Heat Cool Gros N/P/S Heat Cool 6 VI/ 13AAM 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 127C n 3556 34.77 0 0 0 0 0 0 0 0 t�-GC 475-2om 0.770 n 21.56 1931 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 W 13A-4= 0.143 a 4.00 2.55 56 35 142 90 0 0 0 0 �G 1Aa1an - 1270 e 35.56 87.06 0 0 0 0 0 0 0 0 1-D 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A4a 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 13A-0ots 0.143 s 4.00 2.55 0 0 0 0 56 56 226 144 1Actom 1270 S 35M 34.77 0 0 0 0 0 0 0 0 13A4= 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 tAclom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 1Ac1om 1270 w 35.56 54.53 0 0 0 00 0 0 0 4A5-2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P 12C-0sry 0.091 - 255 128 113 113 287 145 66 66 168 84 C 16A-30md 0.032 0.90 2.32 92 92 82 213 42 42 38 97 F 22A4pI 0.989 - 27.69 0.00 92 18 498 0 42 13 360 0 6 c)AED exwrson 49 -24 Envelope lossgain 1239 637 791 301 12 a) Infiltration 107 30 30 b) Roomverdiation 0 0E 0 13 Internal gains: O=pants@ 230 t 0 00 Applianoes(other 00 Subtoml(lines6to 13) 1346 667 331 Less external loac 0 0 0 Lestranser 0 0 0 RedistiMNan 0 0 0 14 Sditel 1346 667 W1 15 Ductloads 29% 57% 387 379 188 Toml room bad 1733 1047Alrrequired(aftr.) 520 72 47 23 Calculations approved bV ACCA t0 meet all requirements of Manual J 8th Ed wr�9hlsofS^ 2021-Jan-1213:18.18 Aft Rigt-THEWILS Universal201919.=M FMIt o Page5 ...DoomerslWngf�ift HVAQWYNNE-THE WINDSORnp CaIc=NIB FmrdDoorfacesN t wrightsofi RighWO Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE UN, Fr. PIERCE, FL 34946 Ptnre: 772-466-6799 Fax 772466-6796 Emil: QUICKCALCS AOL.COM i 1 Room name GREATAINNG Room7 2 Exposed well 50.0 It 13.0 ft 3 Room height 9.4 It heai/mol 9.4 It heakool 4 Room dimensions 1.0 x 567D It 13.0 x 13.0 It 5 Room area 567.0 ft' 169.0 IF Ty Construction U-value Or HTM Area (fl') Load Area Load number (SNhM�°Fj (BWh4h'0 or perimeter (ft) (Stuh) or perimeter (ft) (BWh) Heat Cool Gross WPS Heat Cool Gross NIPS Heat Cool 6 Vy G 13A-0as 0.143 n 4.00 2.55 282 244 978 622 122 107 429 273 1Aclom 127C n 3556 34.77 0 0 0 0 15 0 533 522 L�-GG 4A52om 0.770 n 21M 1931 38 0 815 730 0 0 0 0 W 13A-0acs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 13A4ccs 0.143 e 4.00 2.55 0 0 0 0 0 0 0 0 �C 1Ac1an 1270 a 3556 87.06 0 0 0 0 0 0 0 0 �D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 w 13A-4ocs 0.143 se 4.00 2.551 0 0 0 0 0 0 0 0 y/ 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 t-G 1Ac1cm 1270 a 3556 34.771 0 0 0 0 0 0 0 0 ia44ccs 0.143 w 4.00 2.55 188 147 589 375 0 0 0 0 IA-dom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 1Aclom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 4AS2om 0.770 w 2156 45.63 41 2 880 1862 0 0 0 0 P 12C-Ow 0.091 255 128 0 0 0 0 0 0 0 0 C 16A30md OA32 - 0.90 2.32 567 567 508 1315 169 169 151 392 F 22A-tpl 0.989 - 27B9 0.00 567 50 1385 0 169 13 360 0 6 c)AEDexcursion 307 100 Envelope loss/gain 5154 5210 1474 7086 12 a) Infiltration 889 251 231 65 b) Roomventilation 0 0 0 0 13 Intamal gains: Oovpants@ 230 0 0 1 Applimcle (other 230 0 0 Subttal(lines66113) �, 5461 705 7381 Lessextemaiload 0 Lesstrans+er 0 0 0 Redisfibutial 0 0 14 15 Subtotal Dudloads ;6D43 0 0 1705 0 1381 29% 57% 3105 29% 57% 490 785 Total room load 8556Airrequired(dm} 2195 216l 386 92 98 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed 2021Jar,1213:18:18 A Rigt-THEWINDSOal20tCalc= tRSrort Do ...Doarrzrfs\WrigILOR FNAgWVNNE-hIE WINOSORnp CaIc=M18 Fror¢�ortaces:N Page Duct System Summary Job' Date: Entire House BY QUICK CALCS, INC. 317 ST LUCIE LN., Fr. PIERCE, FL 34946 PMre: 772-466-6799 Fa 772466-6796 Email: 0UICKCALCS a�1 OL.COM Project• For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Heating Cooling Extemal static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/ return available pressure 0.000 /0.000 in H2O 0.000 / 0.000 in H2O Lowest fiction rate 0 in/100ft 0 in/100ft Actual airflow 1160 cfm 1160 Dim Total effective length (TEL) 0 It Supply Branch Detail Table Name Design (Btuh) Fh Htg (cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Dud Mal Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 364 25 16 0 0 Ox0 ShMt 0 0 BEDROOM C 2788 119 126 0 0 Ox0 ShMt 0 0 BEDROOM2 h 2587 117 117 0 0 OXO ShMt 0 0 BEDROOM2-A h 2587 117 117 0 0 Ox0 ShMt 0 0 BEDR00%A C 2788 119 126 0 0 Ox0 ShMt 0 0 ENTRY h 1047 72 47 0 0 Ox 0 ShMt 0 0 GREATANNING C 2855 108 129 0 0 OxO ShMt 0 0 GREATrDINING-A C 2855 108 129 0 0 Ox 0 ShMt 0 0 GREATIDINING-B C 2855 108 129 0 0 OxO ShMt 0 0 KITCHEN c 725 31 33 0 0 Ox0 ShMt 0 0 LAUNDRY h 520 48 23 0 0 Ox 0 ShMt 0 0 M. BATH h 811 49 37 0 0 Ox 0 ShMt 0 0 MASTERBATH h 595 43 27 0 0 OxO ShMt 0 0 Rwm7 C 2167 92 98 0 0 OX 0 ShMt 0 0 WIC c 214 3 10 0 0 Ox0 ShMt 0 0 Return Branch Detail Table Name Grille Size(in) Htg (Cfm) Clg (Cfm) TEL Design (ft) I FR Veloc (fpm) Diam (in) HxW (in) Stud/Joist Opening(in) Dud I Mat Trunk rb1 OxO 1160 1160 0 1 0 0 0 Ox 0 I ShMt Wrightson' 2021- en12131819 � m Rigtt-Sufe®Uriversa1201919.021 RSU08101 Page 1 -.Doo rislWdgYLroRHVAMWYNNE-THEWINDSORnp Calc=MlB FrorGDoorfam&N