HomeMy WebLinkAboutPatterson Roofing information sheet.pdf I-, - ST. LUCIE
L°
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code-Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Required Sections of Attachments Required
Roof System the Permit Application See List Below
Form
Low Slope Application A,B,C 1,2,3,4,5,6,7
Prescriptive BUR-RAS 150 A,B,C 2,4,S,6,7
Asphaltic Shingles A, B,D 1,2,4,5,6,7
Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7
Metal Roofs A,B, D 1,2345,6,T
Wood Shingles and A,B, D IA4,6,6,7
Shakes
Other As Applicable 12,3,4,6,6,7
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128
4. Other Component of Product Approval
5. Municipal Permit Application
6. Owners Notification for Roofing Considerations(Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18,2021
ST LUCIE
Section A(General Information)
Master Permit No. Process No.
Contractors Name: r D 1L' License# K:G 132
Job Address qq L, Uf QGK��l1 � )95W ALOl g
ROOF CATEGORY
❑Lo Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles
Asphaltic Shingles ❑Metal Panel/Shingles Mood Shingles/Shakes
17 Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
New roof ❑ Repair ❑ Maintenance Reroofing M Recovering
ROOF SYSTEM INFORMATION
Low Slope Roof Area(SF) Steep Sloped Roof Area(SF)�,�0 Total(SF).4v.4170 a
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets.
a
I
':1ii�I^f{ii �7 D•-:�r�j Y�k��II_I_I'.��_I IR\.�
r._
ti
02"T LUCIE
Se ion C(Low Slope Roof) Surfacing:
Fill in ecific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
manufac rer Zone 1': "oc @ Lap,#Rows @ "oo
(If a compo nt is not used,identify as"NA") Zone 1• "oc @ Lap,#Rows @ "oo
System Manufa urer: Zone 2: "oc @ Lap,#Rows @ moo
Zone 3: "oc @ Lap,#Rows-@ mooProduct Approval No.•
Number of Fasteners Per Insulation Board:
Design Wind Pressures,Fro RAS 128 Or Calculations: Zone 1'• Zone 1- Zone 2: Zone 3:
Zone 1': Zone 1: Zone Zone 3: Illustrate Components Noted and Details as Applicable:
Max. Design Pressure,from the s cific product approval Woodblocking, Gutter, Edge Termination, Stripping,
system: Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing,Coping,Etc.,
Deck: Indicate:Mean Roof Height, Parapet Height, Height of Base
Type: Flashing,Component Material,Material'Thickness,Fastener
Gauge Thickness: Type,Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
Slope:
Anchor/Base Sheet&No.df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material: FT.
Insulation Base Layer:
Base Insultation Size and Thickness: Parapet
Base Insulation Fastener/Bonding Material: Height
Top Insulation Layer:
Top Insulation Size and Thickness: FT.
Top Insulation Fastener/Bonding Material:
Mean
Base Sheet(s)&No.of Ply(s): Roof
Base Sheet Fastener/Bonding Material: Height
Ply Sheet(s)'&No.of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
ST LUCIE
Section D(Steep Slope Roof S stem)
Roof System Manufacturer:
Notice of Acceptance Number:
�- /'/,0&-�q— � /�
Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations):
Zone 1: Zone 2e: one 2n?'��Zone 2r--'IMZone 3e:r O Zone 3r.
Deck Type:
Type Underlayment 0
Roof Slope:
_: 4 2
• Insulation: YY
F lov. A
Fire Barrier: F-ILzq
Ridge Ventilation? Fastener Type&Spacing: ► �� in�4 S
Adhesive Type:
Type Cap Sheet:
Mean Roof Height: Roof Covering: i aoms mi; �' C
Type&Size Drip
Edge:
' V
LUCID
Se ion E(Tile Calculations)
For ent based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mf.If the Mf values
are Brea than or equal to the Mrvalues,for each area of the roof,then the tile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
ne 1: x IL _ __)-(fig• =Mn Product Approval Mi
Von 2e: x;L _ -Mg: =Mris Product Approval Mf
(Zone - x k = -Mg: =Mom, Product Approval Mf
(Zone 2r: x I = _�-Mg: M� Product Approval Mf
(Zone 3e: x _ _)-Mg: =Mrs Product Approval Mf
(Zone 3r: Mg: =Mear Product Approval Mf
ethod 2"Simplified Tile Calculations Per Table Below"
Required Moment of Resistance(Mr) rom Table Below Product Approval Mf
required Moment Resistance*
Mean Roof Height Roof Slope 15' 20' 25' 30' 40'
2:12 34.4 36.5 38.2 39.7 42.2
3:12 32.2 34.4 36.0 37.4 39.8
4:12 30.4 2.2 33.8 35.1 37.3
5:12 28.4 30. 31.6 32.8 34.9
6:12 26.4 28.0 29.4 30.5 32.4
7:12 24.4 25.9 N 27.1 1 28.2 1 30.0
*Must be used in conjunction with a list of moment based ti systems
• For Uplift based tile systems use Method 3.Compare the val for F'with the values for Fr If the F'values are greater than or
equal to the Fr values,for each area of the roof,then the tile atta ment method is acceptable.
Method 3"Uplift Based Tile Cal lations Per RAS 12T
(Zone 1: x L =x W:= )-W: cos r =Fri Product Approval F'
(Zone 2e: x L =x W:= )-W: cos r =Fr2e Product Approval F'
(Zone 2n: x L =x W:=_)-W: cos r =Frzn Product Approval F'
(Zone 2r: x L =x W:= )-W: cos r =Frzr duct Approval F'
(Zone 3e: x L =x W:= )-W: cos r =Fr3e Pro ct Approval F'
(Zone 3r: x L =x W:= )-W: cos r =Fr3r Produ Approval F'
Where to Obtain Information
Description Symbol Where t and
Design Pressure Zones 1,2e,2n,2r,3e,3r From applicable table in RAS 127 or by n engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height H Job Site
Roof Slope 6 Job Site
Aerodynamic Multiplier Product Approval
Restoring Moment due to Gravity Mg Product Approval
Attachment Resistance Mf Product Approval
Required Moment Resistance Mg Calculated
Minimum Attachment Resistance F' Product Approval
Required Uplift Resistance Fr Calculated
Average Tile Weight W Product Approval
Tile Dimensions L=length W=width Product Approval
All calculations must be submitted to the building official at the time of permit application.