Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Owens Corning Shingles - Product Approval.pdf
OWENS CORNING SCIENCE&TECHNOLOGY,LLC 2790 COLUMBUS ROAD,ROUTE 16 GRANVILLE,OHIO 43023.1200 January 26, 2021 REF: Pending FBC Approvals It has come to our attention that there are building departments that aren't accepting the 2020 FBC Product Approvals for some of our products due to the lack of formal FBC approval.A list of products and Product Approvals for which the status is listed as"Pending FBC Approval" under the 2020 FBC is below: FL10674-R16 Asphalt Shingles FL9777-R14 WeatherLock®Underlayments FL16828-R4 VentSure®Ventilation Products FL19979-R2 DeckSeal®Modified Bitumen Roofing(Nan-HVHZ) FL19982-R2 DeckSeal®Modified Bitumen Roofing (HVHZ) FL11602-R11 Titanium Roof Underayments FL15216-R8 RhinoRoof,ABC Pro Guard 20, and SRS TopShield TS20 Synthetic Roof Underlayments FL32344-RI RhinoRoof Granulated Self-Adhering Underlayment Use of the Florida Product Approval System is voluntary per the Florida Statutes. Please see the verbiage from the Statutes below.Applicable sections are highlighted. 553.8425 Local product approval. (1) For local product approval, products or systems of construction shall demonstrate compliance with the structural windload requirements of the Florida Building Code through one of the following methods: (a) A certification mark, listing, or label from a commission-approved certification agency indicating that the product complies with the code; (b) A test report from a commission-approved testing laboratory indicating that the product tested complies with the code; (c) A product-evaluation report based upon testing, comparative or rational analysis, or a combination thereof, from a commission-approved product evaluation entity which indicates that the product evaluated complies with the code; (d) A product-evaluation report or certification based upon testing or comparative or rational analysis, or a combination thereof, developed and signed and sealed by a Florida professional engineer or Florida registered architect, which indicates that the product complies with the code; (e) A statewide product approval issued by the Florida Building Commission; or (f) Designation of compliance with a prescriptive, material standard adopted by the commission by rule under s. 553.84205). (2) For product-evaluation reports that indicate compliance with the code based upon a test report from an approved testing laboratory and rational or comparative analysis by a Florida registered architect or Florida professional engineer, the testing laboratory or the evaluating architect or engineer must certify independence from the product manufacturer. (3) Local building officials may accept modifications to approved products or their installations if sufficient evidence is submitted to the local building official to demonstrate compliance with the code or the intent of the code, including such evidence as certifications from a Florida registered architect or Florida professional engineer. (4) Products demonstrating compliance shall be manufactured under a quality assurance program audited by an approved quality assurance entity. (5) Products bearing a certification mark, label, or listing by an approved certification agency require no further documentation to establish compliance with the code. (6) Upon review of the compliance documentation, and a finding that the product complies with the code, the authority having jurisdiction or a local building official shall deem the product approved for use in accordance with its approval and limitation of use. (7) Approval shall be valid until such time as the product changes and decreases in performance; the standards of the code change, requiring increased performance; or the approval is otherwise suspended or revoked. Changes to the code do not void the approval of products previously installed in existing buildings if such products met building code requirements at the time the product was installed. Per the above verbiage, our signed and sealed Evaluation Reports are acceptable, even in the absence of a Florida Product Approval. In fact, our products actually comply with Section 553.8425 (1)(a)and (1) (d)above as all of our products bear a Certification Agency mark. We would ask that based on the above information, permits using the affected Product Approval numbers be approved. If you have any questions about the applicable Florida Statute, please contact Mo Madani with the Florida Building Commission at(850)717-1825, Regards, Greg Keeler Technical Services Leader Owens Corning Science &Technology, LLC 740.321.6345 greg.keelerCa owenscorning.com OWENS CORNING 1/26/2021 Florida Building Code Online Bets Home log In User Registration Hot Topics Submit Surcluirge Slats a Facts Publications Contact Us SC15 Site Map Lnks Search dbpr 4 j Product Approval USER:Public user Product AAgnroval Menu>Precinct or Agphcaroo Srnrrp>application List>Application Detail FL# FL10674-1116 Appllcatlon Type Revision Code Version 2020 Application Status Pending FBC Approval Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Coming Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email I Owens Coming PKWY Toledo,01143659 (419)376.8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M.Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 01/01/2099 Validated By John W. Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R16 COI 2020 01 COI NIEMINEN Rif Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM 03161 2016 ASTM D3462 2010 ASTM 07158 2019 Equivalence of Product Standards Certified By Sections from the Code hUps://www.Roridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V°/p2boQTp/,2b6w7ahRegiCOSucR6ixEAIpOjcKTwwbwp/o3dp/o3d 112 1/26/2021 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 12/11/2020 Date Validated 12/17/2020 Date Pending FBC Approval 12/26/2020 Summary of Products FL# Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab, 4-tab, laminated, starter and hip&ridge shingles Shingles and Starters Limits of Use Installation Instructions Approved for use in HVH2:No FL10674 R16 11 2020 12 11 FINAL ER OC ASPHALT Approved for use outside HVH2:Yes SHINGLES FL10674-R16.odf Impact Resistant: N/A Verified By: Robert J.M.Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party:Yes Other:Refer to ER,Section S. Evaluation Reports AE 2020 12 11 FINAL ER OC ASPUAU SHINGLES FL10674-Ri6.p&lf Created by Independent Third Party:Yes 0 0 Contact us::2601 Blair Stone Road Tallahassee R 32399 Phone:950,497,1824 The State of Florida is an WEED employer,r�eppy�ght 2007-2013 Stale of Flonda.;:Pnvtry Statement::Accessibility Statement::Refund Statemrnt Under Honda law,email addresses am public records.If you do not want your e-mail address released In response to a public-records request,do rot sand electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact SSO.487.1395.'pursuant to Section 455.I75(1). Honda starutes,effective October 1,2012.licensees licensed under Chapter 4S5,F.S.must preNde the Department with an email address If May have one.The emaile provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you am a licensee under Chapter 455,ES.,please click here. Product Approval Accepts: �© ® El®v Credit Carcl Safe https://www.floridabuilding.org/pr/pr_app_dll.aspx?param=wGEVXQwlDgtBNbEY5V%2boOT4/o2b6w7ahReglCQBucR6ixEAIpOjcKTwwbw%3d%3d 2/2 MEMO l etc. Certificate ofAuthorization#32455 353 Christian Street,Unit#13 Oxford,CT 06478 (203)262-924S ENGINEER EVALUATE TEST CONSULT REPORTEVALUATION Owens Corning Evaluation Report 037940.02.12-Ril One Owens Corning Parkway FL10674-R16 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404.7829 Revision 11: 12/11/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7"Edition(2020) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance Or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: „ �ia%e3i:b' it _ Robert l.M.Nieminen,P.E. w - The facsimile seal appearing was authorized by Robert '•,3�I�t,a'ci,: electronically son ddoc men This dcesnet serve as an Florida Registration No.59166,Florida DCA ANE1983 ":!?.,6., � electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEW ETC,LLC does not have,nor does it Intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product- S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018 NEMO ETC,LLC ONEMOletc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 71h Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. JrAkLi Section Property Standard Year 1507.2.4,R905.2.3 Physical Properties ASTM 01970 2015 1507.2.5,R905.2.4 Material standard ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2019 3. REFERENCES: Entity Examination Reference Date Owens Corning Declaration Equivalency Declaration 08/06/2019 FRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 PRI(QUA9110) Quality Control Service Confirmation 04/05/2020 PM(QUA9110) Quality Control Florida BCIS Current TABLE 1:ASPHALT SHINGLE COMPONENTS Type Product Plant(s) Material Description Standard Starter Strip Shingle H-TX,OR Accessory Starter Strip Plus MN,OR ASTM D3462 starter strips for asphalt roof shingles Starter SRS To Shield Starter MN,OR Strips Starter Shingle Roll NH ASTM D1970 mineral-surfaced,fiberglass-reinforced. self-adhering SBS modified bitumen starter Supreme GA,CA,CO,I-TX,NJ,OH, ASTM D3462 fiberglass reinforced 3-tab asphalt TN,OR,IL roof shingles Berkshire' MN ASTM D3462 fiberglass reinforced,4-tab asphalt roof shingles Duration Premium CA,OR Asphalt Duration'Premium COOL CA Shingles TruDeFinition-Duration IN,CA,CO,I-TX,FL,NJ,OH, TruDefinition'Duration' Designer Color Collection MN,OR,GA,IL,TN ASTM D3462 fiberglass reinforced,laminated GA,IN,CA,CO,H-TX,I-TX, asphalt roof shingles Oakridge FL,NJ OH,TN TruDefinition-Oakridge' H-TX,I-TX WeatherGuard'HP TN NEMO ETC,LLC Evaluation Report 037940.02.12-Rll Certificate of Authorization 432455 7"'EDITION(2020)FBC NON-HVHZ EVALUATION FL30674-R16 Owens Corning Asphalt Roof Shingles Revision 21:12/11/2020 Page 2 of 10 ON EMO I etc. TABLE 1:ASPHALT SHINGLE COMPONENTS Type Product Plant Materials) Standard Description Berkshire'Hip and Ridge MN Shingles with Sealant Hip and OuraRidge•Hip and Ridge MN fiberglass reinforced,hip and ridge Ridge Shingles with Sealant ASTM D3462 asphalt roof shingles Shingles ProEdge' GA,CA,OH,OR WeatherGuard'HP Hip and TN Ridge Shingles 5.1 This is a building code evaluation. NeitherNEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic Insulation. 5_5 Wind Classification:Refer to Section 6 for installation requirements to meet wind classifications TABLE 2A:WIND CLASSIFICATIONS,ASPHALTSHINGLES Product FBC Table 1507.2.7.1 or R905.2.6.1 Supreme Berkshire Duration Premium Duration'Premium COOL TruDefinition'Duration ASTM D3161(F)&ASTM D7158(H) TruDefinition'Duration'Designer Color Collection Oakridge' TruDefinition'Oakridge' WeatherGuard*HP 5.5.1 Classification by ASTM D7158: ASTM D7158,Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. NEMO ETC,LLC Evaluation Report 037940.02.12-1111 Certificate of Authorization 032455 7"'EDITION(2020)FBC NON-HVHZ EVALUATION F1.10674-1116 Owens Corning Asphalt Roof Shingles Revision 11;12/11/2020 Page 3 of 10 ON EMO etc. TABLE 2B:WIND CLASSIFICATIONS,STARTER STRIPS AND HIP&RIDGE Type Product FBC Table 1507.2.7.2 or R905.2.6.1 Starter Strip Shingle Starter Strips Starter Strip Plus ASTM D3161,Class F SRS TopShield Starter Berkshire'Hip and Ridge Shingles with Sealant Hip&Ridge DuraRidge°Hip and Ridge Shingles with Sealant Shingles ProEdge° ASTM D3161,Class F WeatherGuard'HP Hip and Ridge Shingles 5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations. 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. t, 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORY STARTERS: 6.2.1 Installation of Starter Strip Shingle,Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions,using minimum five(5)nails per strip. Feltvndenavment - Deok rd eoded+rmmr oen sdl m." weame4nca! Sell-adhered wde,hrmmi .Weatlawl.m e undedarment trip a'4�` BIIP sdOe a � ads. 9, -r -Naas located -;,aaa Ima - ra .y" 2--3'from save J� Imtad first i� �p Seaseaeneadhnive h+W un sr,nn svggn SeF.e4.q am+ni,e shi"le V2 Positioned abna nve 16',� 6'removad S.'u.Ono rin a+<m°Na e+.n,Nnan Va'-La' Starter stripshinala overhangs eaves and non 7=!' Figure 1:Minimum Nailing,Starter Strip Figure 2:Minimum Nailing,Starter Strip Plus NEMO ETC,LLC Evaluation Report 037940.02.12-RII Certi/Imre ofAuthodnotion 43245S 7'"EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-RI6 Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 4 of 20 ONEMO etc. 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. Deck Underlayment Drip edge i Drip edge Starter Shingle Roll adhered directly to undedayment and primed drip edge Self-sealing adhesive positioned along eaves Figure 3:Starter Shingle Roll 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: > Berkshire'shingles require minimum five(5)nails per shingle. > WeatherGuard'HP shingles require minimum six(6)nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Supreme: Normal Mansard er Arne pare Normal Mansard or Area par. Wind Areas High Wind deavanesY Wind Areas High Wind desvanesv Aron pore vientas normelas Areas vionme fuertas Area porn vientos nnrmales Areas vienroa fuerros IAI ' a rz s (•'• s• (B `z. '•'' rr IAI ' f'• z fel z. �'_: n• �titT 5`E.posura 6 6/a'E.pomra E.posieidn E.paviaidn Figure 4:Minimum Nailing,Supreme figure 5:Minimum Nailing,Supreme (Standard Size) (Metric Size) NEMO ETC,U.0 Evaluation Report 037940.02.12•R31 Certificate of Authorization e32455 7"'EDITION(2020)FBC NON-HVHZ EVALUATION F1.10674-1136 Owens Corning Asphalt Roof Shingles Revision 11:12/12/2020 Page S of 20 *NEMO etc. 6.3.1.2 Berkshire®: Snhm strip s•olant strip U rSada unda Uba de Wbd•r ey Uvf 0vf ak^ } � :�r s'i' 8@' eaY• t Figure 6: 5-Nail Pattern,Berkshire Figure 7: 6-Nail Pattern,Berkshire Stahm 5h'ry U r4a de ullder r r1 a a�fi__ r: 2' Asphah rmlingmmem LsmonfO dusrAode aAallO Figure 8: Mansard or Steep Slope Pattern,Berkshire NEMO ETC,LLC Evaluation Report 037940.02.12-1131 Certi(rCate OfAuthonmooa 932455 7"'EDITION t20201 FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 6 of 10 ONEMID etc. 6.3.1.3 Duration• Premium, TruDeflnition• Duration, Durations' Premium COOL & TruDefinitiofi Duration' Designer Color Collection: 4-Nail Fastening Pattern Nal YpIcal •........., ...�SuleNaa width 1" 1 2�' _ 1 I 12" 1"— - 6-1/e" 5.51a" z.o.z.. Figure 9:Standard 4-Nall Pattern,Duration 6-Nail Fastening Pattern SUMN3110 fastening area width Ir—Nail.Typical 1" 12" 1 12" t" re 6-1M. 5.5I8" Figure 10: 6-Nail Pattern,Duration Fastening for Slopes Greater Than 21:12 SUMNSIM fastening area winth Ir Nall,Typical /" 12" / 12- 1" F1 61/B- 5�z ye T2" F l Four 1"Spot,of Asphalt Roofing Cement Figure 11: Mansard or Steep Slope Pattern,Duration NEMO ETC,LLC Evaluation Report 037940.02.12.Rll Cerri/Irate of Authorization 9324SS 7"'EDITION(2020)F8C NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11:12/11/20Z0 Page 7 of 10 NNEMO etc. 6.3.1.4 TruDeffnition OakrideeO,Oakridee*: 4 Nall Pattern 6 Nall Pattern Esquema con 4 cfavos Esquema con 6 chives r t. t. r r I<-- ter —►I k— r<—>I �F Y. _� f<— ¢_� 65R-Fxymure Napk ISOM Exposure Naas Ek—Wonde551spWg Craver Expodevn or 55:dp:dc. 6612-Expowre Clvm 5&W Expoou 9pos1ddnde551Tptdg Exposrtidn de 5619pNg Figure 12:Standard 4-Nail Pattern,Oakridge Figure 13:6-Nail Pattern,Oakridge Fastening for Slopes Greater Than 21:12 SuraWkP lastanlne cult.n. wldth era. rypTypical,.'• t� al, 12^ Four V Sharp or Asphalt Routine courant Figure 14:Mansard or Steep-Slope Pattern,Oakridge 6.3.1.5 WeatherGuard®HP: 6 N ad Pattern Fsquema con 6 cloves Nail 1;8"from bottom of shhgle Clove a 6 1:6 puy.de la 5 5.T Exposure 6 Fasteners parse inferior de 6 teja 7 Exposicidn de 5 5.8 pulg. 6 suietadures 11 O,\ ",/ I• 'isS 2a4 \v Sera :an — g5e'Eq.,. 554' ass< Four 1'Spots of Asphalt Roof Cement EopxoanEta.;4,1 5 Maur Cuatro punlus de eemenro de tedto de asfdta de 1 pugoda Figure 15:6-Nail Pattern,WeatherGuard HP Figure 16:Mansard or Steep-Slope Pattern,WeatherGuard HP NEMO ETC,LLC Evaluation Report 037940.02.12-Rll Co"iftets ofAutaorvation 032455 VuEDITION(2020)F8C NON-HVHZ EVALUATION FL10674-RlG Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 8 of 10 NNIEMO I etc. 6.4 HIP AND RIDGE SHINGLES: 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. ➢ Berkshire'Hip and Ridge Shingles with Sealant and DuraRidge° Hip and Ridge Shingles with Sealant require minimum two(2)nails per shingle. WeatherGuard'HP Hip and Ridge Shingles and ProEdgea require minimum four(4)nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. 6.4.1.1 Berkshire®Hip and Ridge with Sealant and DuraRidge®Hip and Ridge Shingles with Sealant: Fig. A Fig. B Top view Prevailing Wind Direction p s— Direccidn del viento predominanle Vista superior If 1"IH Nail 2W Clan Nails- Owens Coming SureNd' Clavos 87 11 ml n ii++--gn--ssll `m l �spmidOdelpolgl `-'i�, @� 12 Figure 17:Isometric View,Berkshire and DuraRidge Figure 18:Plan View,Berkshire and DuraRidge 6.4.1.2 WeatherGuard*HP Hip and Ridge Shingles: Fig.A a v Fig.C Hip&Ridge Shingle Fastening F_Pmvaaing Wlnd ��' Top Vkw Dhection 4� \ AX A`. —----------------- `• � Ilalb Iloib D L44 •\ 7. s' I 2 i i . v Ezposaeo ,,,\ tip Eaposum figure 19:Isometric View,WeatherGuard HP Hip and Ridge Figure 20:Plan View,WeatherGuard HP Hip and Ridge NEMO ETC,LLC Evaluation Report 037940.02.12-Rll Ceaifimre olAuthorizotion 032455 7"EDITION 12020)F8C NON-HVHZ EVALUATION FL30674-1136 Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 9 of 10 NNEMO etc. 6.4.1.3 ProEdge": Prevailing Standard Wind Direction Fastening 6calxnt Strip Pattern 6'Exposure -/� 1' I,r �I•I I• T FI 111 Sealant Fasten 7'fi 17— 6'Exposure Cover E. with 1 J I{ Fasteners Roof Cement Figure 21:Isometric View,ProEdge Figure 22: Plan View,ProEdge il [ I-7aift'di-;f7 llk�a�rla�'w4 . . As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the named CA entity for manufacturing facilities covered by F.A.C.Rule 61G20.3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. e PRI Construction Materials Technologies,LLC-QUA9110; 813 621-5777;bwilson(@Dricmt.com - END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 037940.02.12-RIL Ceni(rmta ofAuthoriratron 432455 7"EDITION 12020)FBC NON-HVHZ EVALUATION F1.30674-1136 Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 10 of 10