Loading...
HomeMy WebLinkAboutInspection Docs Q ST. LUCIE WORKS RECEIVED ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET OCT 2 6 2021 Florida Building Code 7th Edition (2020) St.Lucie County - Permitting Based on Section 1525 of the Florida Building Code-Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A, B,C lgA4A,%7 Prescriptive BUR-RAS 150 A, B,C 2,4,5,6,7 Asphaltic Shingles A,B, D 1X4A,%7 Concrete or Clay Tile A, B,D, E Metal Roofs A,B, D Wood Shingles and A, B, D t4-4A%7 Shakes Other As Applicable 1,24,5;B,7 ATTACHMENTS REQUIRED As Applicable): F11, kouply 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18,2021 ST. LUCIE WORKS Section C(Low Slope Roof) Surfacing: Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base S et Attachment: manufacturer = .000 ' _.- Zone 1':—."oc @ Lap,#R s (If a component is not usedj&ptiljras"NA' Zone 1:—"oc @ Lap,# ows 0. `66' y: System Manufacturer: Zone 2:—."oc @ Lap Rows 0 ' Zone 3:—"oc @ L ,#Rows 0 00 ' Product Approval No.: Number of Fasten s Per Insulation Board: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1':— one 1: Zone 2: Zone 3: Zone 1':—Zone 1: Zone 2:_Zone 3- Illustrate C mponents Noted and Details as Applicable: Max. Design Pressure,from the specific product approval Woodbl eking, Gutter, Edge Termination, Stripping, system: Flashi g, Continuous Cleat, Cant Strip, Base Flashing, Co terflashing,Coping, Etc., Deck: I icate: Mean Roof Height, Parapet Height, Height of Base Type: lashing,Component Material,:Material'Thickness, Fastener Type,Fastener Spacing or Submit Manufacturers Details that Gauge Thickness: Comply with RAS 1 11 and Chapter 16.. Slope: Anchor/Base Sheet&No.df Ply(s): FT. Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Parapet Base Insulation Fastener/Bonding Mate.- Height Top Insulation Layer: Top Insulation Size and Thicknes . FT. Top Insulation Fastener/Bon ng Material: Mean Base Sheet(s)&No.of ly(s): Roof Base Sheet Fastener Bonding Material: Height Ply Sheet(s)' No.of Ply(s): L.. Ply Sheet Fastener/Bonding,Material: Top Ply: Top Ply Fastener/Bonding Material: ST. UCIE WORKS 3 ��lflE��' 17`' FC �? UANCE Section D(Steep Slope Roof System) ACC, Roof System Manufacturer: Notice of Acceptance Number: L, k'-7 Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations): Zone 1:�Zone 2e:�one 2n Z Zone 2r� Zone 3e$� Zone 3r:Q I Deck TYPe � Type:Undedaiyment J.R tf StoPe: t2 � - _ lrsula�an Fire lamer. Ridge�leril an? agterer Tjrpe Spacing: .fit D C� adhesive Type: Type Cap;,9hpet l Mean RocfHeigttt � ) Roof Cavering:. Type$Sm Drip 2 2 Edge: FILE COPY ST. LUCIE WORKS Section A (General Information) Master Permit No. Process=No, Contractors Name7V�q 6 G'�1�111��License# Job Address ROOF CATEGORY E3 Low Slope :retal anically Fastened Tile El Mortar/Adhesive Set Tiles 0 Asphaltic Shingles Panel/Shingles Mood Shingles/Shakes Prescriptive BUR-RAS 150 ROOF ROOF TYPE New roof 0 Repair El Maintenance ®/Reroofing E3 Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) Total (SF) � Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and F441c r P Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location o pa ape '' 7LE 1 ST. LUCIE WORKS Section E.(Tile Calculations) For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mf.If the Mf values are greater than or equal to the Mr values,for each area of the roof,then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: Product Approval Ms (Zone 2e: Xk = _ .-111 -: Product Approval Mf (Zone 2n: �t.x = _� Lift Product Approval Mf, (Zone 2r: X _ _ Product Approval Mf (Zone 3e: xX_= Product Approval Mf (Zone 3r: XA, - 9 *' Product Approval Mf Method 2"Simplified Tile Calculations Per Table Below" Required Moment of Resistance(Mr) From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof Slope 15' 20, 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6. 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems • For Uplift based tile systems.use Method 3.Compare the values for F'with the values for Fr If the F'values are greater than or equal to the Fr values,for each area of the roof,then the tile attachment method is acceptable. Method 3"Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L =x W:= )-W: cos r =Fr1 Product Approval F' (Zone 2e: x L =x W:= )-W: cos r =Fr2e Product Approval F' (Zone 2n: x L =x W:= )-W: cos r =Fr2n Product Approval F' (Zone 2r: x L =x W:= )-W: cos r =Fr2r Product Approval F' (Zone 3e: x L =x W:= )-W: cos r =Fr3e Product Approval F' (Zone 3r: x L =x W:= )-W: cos r =Fr3r Product Approval F' Where to Obtain Information Description Symbol Where to find From applicable table in RAS 127 or by an engineering analysis Design Pressure Zones 1,2e,2n,2r,3e,3r prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L=length W=width Product Approval All calculations must be submitted to the building official at the time of permit application.