Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED ,005 Energy Calcs
7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 76/9/2021 12:20 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie County Charles Residence Charles Residence Street: City, State, Zip: Fort Pierce , FL , 34945 18900 Schumann Road Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Detached 1 No 2700 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : Sgl, U=1.11 128.00 ft² SHGC=0.26 Sgl, U=0.81 96.00 ft² SHGC=0.27 Sgl, U=1.02 69.33 ft² SHGC=0.29 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 2700.00 ft² R=f t ² R=f t ² 10. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 2832.50 ft² b. N/A R=f t ² c. N/A R=f t ² 11. Ceiling Types a. Roof Deck (Unvented)R=20.0 2700.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts a. Sup: Attic, Ret: Attic, AH: Pantry 13. Cooling systems 14. Heating systems 15. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:3.064 ft. Area Weighted Average SHGC:0.270 Description Area Insulation Area Insulation Area Insulation Area 16. Credits CF, Pstat 2 (293.3 sqft.) (2832.5 sqft.) (2700.0 sqft.) (2700.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 41.0 SEER:16.00 Efficiency k B t u / h r Efficiency 34.0 COP:1.00 f t ² R 6 85 EF: 0.950 8. Skylights c. U-Factor:(AVG) S H G C ( A V G ) : N/A N/A f t ² Area Glass/Floor Area: 0.109 Total Proposed Modified Loads: Total Baseline Loads: 77.65 81.76 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2020 6-9-2021 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie County 1 Charles Residence Charles Residence Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: 0 No 1 2700 2 New (From Plans) Detached Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , 34945 Fort Pierce , St. Lucie 18900 Schumann Road Street Address Comment: Building Type: User Cross Ventilation: No Whole House Fan: No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 2700 27000 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 M Bath 166 1660 No 1 Yes Yes1 Yes 2 Toilet 40 400 No 0 Yes Yes1 Yes 3 M WIC 2 84 840 No 1 Yes Yes1 Yes 4 M WIC 1 80 800 No 1 Yes Yes1 Yes 5 M Bedroom 350 3500 No 2 1 Yes Yes1 Yes 6 Den 120 1200 No 2 Yes Yes1 Yes 7 Foyer 81 810 No 0 Yes Yes1 Yes 8 Bedroom 3 144 1440 No 2 1 Yes Yes1 Yes 9 WIC 3 72 720 No 1 Yes Yes1 Yes 10 Bath 3 78 780 No 0 Yes Yes1 Yes 11 Pantry 207 2070 No 1 Yes Yes1 Yes 12 Bath 2 64 640 No 0 Yes Yes1 Yes 13 Laundry 128 1280 No 0 Yes Yes1 Yes 14 Hall 1 70 700 No 0 Yes Yes1 Yes 15 Living Room 564 5640 No 2 Yes Yes1 Yes 16 Utility 99 990 No 0 Yes Yes1 Yes 17 Kitchen 341 3410 Yes 2 Yes Yes1 Yes 18 Hall 2 12 120 No 0 Yes Yes1 No 6/9/2021 12:20 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 166 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -25 ft M Bath 2 40 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -13 ft Toilet 3 84 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -3 ft M WIC 2 4 80 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -8 ft M WIC 1 5 350 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -20 ft M Bedroom 6 120 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -13 ft Den 7 81 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -9 ft Foyer 8 144 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -15 ft Bedroom 3 9 72 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -27 ft WIC 3 10 78 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -13 ft Bath 3 11 207 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -23 ft Pantry 12 64 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -8 ft Bath 2 13 128 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -32 ft Laundry 14 70 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -9 ft Hall 1 15 564 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -24.2 ft Living Room 16 99 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -27 ft Utility 17 341 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -14 ft Kitchen 18 12 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall 2 # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Metal 2925 ft² Light 0.6 20 22.62______ No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 2700 ft² N N0 6/9/2021 12:20 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented) 0 166 ft² 0.1 Wood______ M Bath Blown 2 Under Attic (Unvented) 0 40 ft² 0.1 Wood______ Toilet Blown 3 Under Attic (Unvented) 0 84 ft² 0.1 Wood______ M WIC 2 Blown 4 Under Attic (Unvented) 0 80 ft² 0.1 Wood______ M WIC 1 Blown 5 Under Attic (Unvented) 0 350 ft² 0.1 Wood______ M Bedroom Blown 6 Under Attic (Unvented) 0 120 ft² 0.1 Wood______ Den Blown 7 Under Attic (Unvented) 0 81 ft² 0.1 Wood______ Foyer Blown 8 Under Attic (Unvented) 0 144 ft² 0.1 Wood______ Bedroom 3 Blown 9 Under Attic (Unvented) 0 72 ft² 0.1 Wood______ WIC 3 Blown 10 Under Attic (Unvented) 0 78 ft² 0.1 Wood______ Bath 3 Blown 11 Under Attic (Unvented) 0 207 ft² 0.1 Wood______ Pantry Blown 12 Under Attic (Unvented) 0 64 ft² 0.1 Wood______ Bath 2 Blown 13 Under Attic (Unvented) 0 128 ft² 0.1 Wood______ Laundry Blown 14 Under Attic (Unvented) 0 70 ft² 0.1 Wood______ Hall 1 Blown 15 Under Attic (Unvented) 0 564 ft² 0.1 Wood______ Living Room Blown 16 Under Attic (Unvented) 0 99 ft² 0.1 Wood______ Utility Blown 17 Under Attic (Unvented) 0 341 ft² 0.1 Wood______ Kitchen Blown 18 Under Attic (Unvented) 0 12 ft² 0.1 Wood______ Hall 2 Blown WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0M Bath 00014 10S Concrete Block - Int Insul 0.40Exterior 140.0 ft² ____ 2 4.1 0M Bath 00011 10W Concrete Block - Int Insul 0.40Exterior 110.0 ft² ____ 3 4.1 0Toilet 0008 10E Concrete Block - Int Insul 0.40Exterior 80.0 ft² ____ 4 4.1 0Toilet 0005 10S Concrete Block - Int Insul 0.40Exterior 50.0 ft² ____ 5 4.1 0M WIC 2 0003 10S Concrete Block - Int Insul 0.40Exterior 30.0 ft² ____ 6 4.1 0M WIC 1 0008 10W Concrete Block - Int Insul 0.40Exterior 80.0 ft² ____ 7 4.1 0M Bedroom 00020 10W Concrete Block - Int Insul 0.40Exterior 200.0 ft² ____ 8 4.1 0Den 0003 10E Concrete Block - Int Insul 0.40Exterior 30.0 ft² ____ 9 4.1 0Den 00010 10S Concrete Block - Int Insul 0.40Exterior 100.0 ft² ____ 10 4.1 0Foyer 0009 10S Concrete Block - Int Insul 0.40Exterior 90.0 ft² ____ 11 4.1 0Bedroom 3 00012 10S Concrete Block - Int Insul 0.40Exterior 120.0 ft² ____ 12 4.1 0Bedroom 3 0003 10W Concrete Block - Int Insul 0.40Exterior 30.0 ft² ____ 13 4.1 0WIC 3 00012 10E Concrete Block - Int Insul 0.40Exterior 120.0 ft² ____ 14 4.1 0WIC 3 0006 10S Concrete Block - Int Insul 0.40Exterior 60.0 ft² ____ 15 4.1 0WIC 3 0009 10W Concrete Block - Int Insul 0.40Exterior 90.0 ft² ____ 16 4.1 0Bath 3 00013 10E Concrete Block - Int Insul 0.40Exterior 130.0 ft² ____ 17 4.1 0Pantry 00023 10E Concrete Block - Int Insul 0.40Exterior 230.0 ft² ____ 18 4.1 0Bath 2 0008 10W Concrete Block - Int Insul 0.40Exterior 80.0 ft² ____ 19 4.1 0Laundry 00013 10N Concrete Block - Int Insul 0.40Exterior 130.0 ft² ____ 20 4.1 0Laundry 0008 10E Concrete Block - Int Insul 0.40Exterior 80.0 ft² ____ 21 4.1 0Laundry 00011 10W Concrete Block - Int Insul 0.40Exterior 110.0 ft² ____ 22 4.1 0Hall 1 0003 10N Concrete Block - Int Insul 0.40Exterior 30.0 ft² ____ 6/9/2021 12:20 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 23 4.1 0Hall 1 0006 10E Concrete Block - Int Insul 0.40Exterior 60.0 ft² ____ 24 4.1 0Living Room 00017 10N Concrete Block - Int Insul 0.40Exterior 170.0 ft² ____ 25 4.1 0Living Room 0037 10NW Concrete Block - Int Insul 0.40Exterior 72.5 ft² ____ 26 4.1 0Utility 0009 10N Concrete Block - Int Insul 0.40Exterior 90.0 ft² ____ 27 4.1 0Utility 00011 10E Concrete Block - Int Insul 0.40Exterior 110.0 ft² ____ 28 4.1 0Utility 0007 10W Concrete Block - Int Insul 0.40Exterior 70.0 ft² ____ 29 4.1 0Kitchen 00011 10N Concrete Block - Int Insul 0.40Exterior 110.0 ft² ____ 30 4.1 0Kitchen 0003 10W Concrete Block - Int Insul 0.40Exterior 30.0 ft² ____ # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 W Low-E Single 0.81 0.27 30.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes7 Y 2 S Low-E Single 0.81 0.27 15.0 ft² 6 ft 0 in 1 ft 4 in NoneVinyl None______ Yes9 Y 3 S Low-E Single 1.02 0.29 24.0 ft² 10 ft 0 in 1 ft 4 in NoneVinyl None______ Yes10 Y 4 S Low-E Single 0.81 0.27 15.0 ft² 6 ft 0 in 1 ft 4 in NoneVinyl None______ Yes11 Y 5 E Low-E Single 0.81 0.27 9.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes16 Y 6 N Low-E Single 0.81 0.27 13.5 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes19 Y 7 E Low-E Single 1.02 0.29 22.7 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes23 Y 8 N Low-E Single 1.11 0.26 128.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes24 Y 9 NW Low-E Single 1.02 0.29 22.7 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes25 Y 10 N Low-E Single 0.81 0.27 13.5 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes29 Y Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 2250 5123.44.000317Wholehouse .0987231.75Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtype BlockSpeed 1 Electric Strip Heat/ COP:1 34 kBtu/hr ______ sys#1None 1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtype BlockSubtype 1 Central Unit/ SEER: 16 41 kBtu/hr c f m 0.7______ sys#1Split 1 Singl 6/9/2021 12:20 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.95 50 gal 60.9 gal 120 deg None______ None Laundry FSEC Company Name System Model # Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert # Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply ---- ---- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 85 ft² Attic 20 ft² Prop. Leak Free Pantry 81.0 cfm 0.03 0.50______ 1 1 --- cfm TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078 Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 M Bath Default(8 lbs/sq.ft. f t ² f t 0.3 Toilet Default(8 lbs/sq.ft. f t ² f t 0.3 M WIC 2 Default(8 lbs/sq.ft. f t ² f t 0.3 M WIC 1 Default(8 lbs/sq.ft. f t ² f t 0.3 M Bedroom Default(8 lbs/sq.ft. f t ² f t 0.3 Den Default(8 lbs/sq.ft. f t ² f t 0.3 Foyer Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 3 Default(8 lbs/sq.ft. f t ² f t 0.3 WIC 3 Default(8 lbs/sq.ft. f t ² f t 0.3 Bath 3 Default(8 lbs/sq.ft. f t ² f t 0.3 Pantry Default(8 lbs/sq.ft. f t ² f t 0.3 Bath 2 Default(8 lbs/sq.ft. f t ² f t 0.3 Laundry Default(8 lbs/sq.ft. f t ² f t 0.3 Hall 1 Default(8 lbs/sq.ft. f t ² f t 0.3 Living Room Default(8 lbs/sq.ft. f t ² f t 0.3 Utility 6/9/2021 12:20 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. f t ² f t 0.3 Kitchen Default(8 lbs/sq.ft. f t ² f t 0.3 Hall 2 6/9/2021 12:20 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Project Name: Owner: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie County Charles Residence Charles Residence Street: City, State, Zip: Fort Pierce , FL , 34945 18900 Schumann Road Permit Number: Design Location: FL, Fort Pierce CHECKAIR BARRIER CRITERIA A continuous air barrier shall be installed in the building envelope. The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. The junction of the top plate and the top of exterior walls shall be sealed. Knee walls shall be sealed. The space between window/door jambs and framing, and skylights and framing shall be sealed. Rim joists shall include the air barrier. The air barrier shall be installed at any exposed edge of insulation. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Shafts, penetrations Crawl space walls Floors (including above-garage and cantilevered floors) Rim joists Windows, skylights Walls Ceiling/attic General COMPONENT Garage separation Recessed lighting Plumbing and wiring S h o w e r / t u b HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor, wall covering or The air barrier shall be installed behind electrical or communication boxes or air-sealed boxes shall be installed. The air barrier installed at exterior walls adjacent to showers and tubs shall separate them from the showers and tubs. Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Recessed light fixtures installed in the building thermal envelope shall be sealed to the finished surface. Air sealing shall be provided between the garage and conditioned spaces. When required to be sealed, concealed fire sprinklers shall only be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. C o n c e a l e d Electrical/phone box on exterior walls Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA INSULATION INSTALLATION CRITERIA EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software6/9/2021 12:20 PM Page 1 of 1 Air-permeable insulation shall not be used as a sealing material. The insulation in any dropped ceiling/soffit shall be aligned with the air barrier. Cavities within corners and headers of frame walls shall be insulated by completely filling the cavity with a material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Rim joists shall be insulated. Floor framing cavity insulation shall be installed to maintain permanent contact with the underside of subfloor decking, or floor framing cavity insulation shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. and doors on exterior wall requirements Recessed light fixtures installed in the building thermal envelope shall be air tight and IC rated. sprinklers Where provided instead of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exterior walls adjacent to showers and tubs shall be insulated. 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. a 18900 Schumann Road, Fort Pierce, FL, 34945 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft²) New (From Plans) Detached 1 2 No 2700 7. Windows** a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=1.11 128.00 ft² SHGC=0.26 Sgl, U=0.81 96.00 ft² SHGC=0.27 Sgl, U=1.02 69.33 ft² SHGC=0.29 N/A f t ² 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 2700.00 ft² R= f t ² R= f t ² 10. Wall Type and Insulation a. Concrete Block - Int Insul, Exterior R=4.1 2832.50 ft² b. N/A R= f t ² c. N/A R= f t ² 11. Ceiling Type and insulation level a. Roof Deck (Unvented) R=20.0 2700.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts, location & insulation level 13. Cooling systems 14. Heating systems k B t u / h r 15. Hot water systems a. Electric Cap: 50 gallons EF: 0.95 b. Conservation features None d. N/A R= f t ² Description Area Insulation Area Insulation Area Insulation Area Credits (Performance method) CF, Pstat Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 3.064 ft. 0.270 a. Electric Strip Heat 34.0 COP:1.00 a. Central Unit 41.0 SEER:16.00 k B t u / h r Efficiency Efficiency a. Sup: Attic, Ret: Attic, AH: Pantry 6 85 R f t ² 8. Skylights a. U-Factor(AVG): S H G C ( A V G ) : Description Area N/A N/A f t ² I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature:Date: Address of New Home:City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. Page 1 of 1 FORM R405-2020 6/9/2021 12:20 PM Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:27:58 Ri g ht-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 1 ...Documents\Wrightsoft HVAC\Charles Residence.rup Calc = MJ8 Front Door faces: S Job:Project Summary Date:Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com Project Information Charles ResidenceFor:18900 Schumann Road, Fort Pierce, FL 34945 Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15Daily range M Relative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh35606 Structure Btuh25283 Ducts Btuh5776 Ducts Btuh3940Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 (none)(none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh41381 Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load Btuh27761 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh6008 Ducts Btuh2993Central vent (0 cfm)Btuh0 CoolingHeating (none)27002700Area (ft²)Equipment latent load Btuh9001 2700027000Volume (ft³)Air changes/hour 0.160.32 Equipment Total Load (Sen+Lat)Btuh36762 Equiv. AVF (cfm)72144 Req. total capacity at 0.70 SHR ton3.3 Heating Equipment Summary Cooling Equipment Summary Make Make TraneTradeTradeTRANE Model Cond 4TTR6042J1AHRI ref Coil TEM4A0C42S41++TDR AHRI ref 8703699Efficiency100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW12.0 Sensible cooling Btuh28700Heating output Btuh41030 Latent cooling Btuh12300 Temperature rise °F27 Total cooling Btuh41000Actual air flow cfm1367 Actual air flow cfm1367 Air flow factor cfm/Btuh0.033 Air flow factor cfm/Btuh0.047Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.76 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:27:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 1...Documents\Wrightsoft HVAC\Charles Residence.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Entire House M Bath 2 Exposed wall 283.2 ft 25.0 ft 3 Room height 10.0 ft 10.0 heat/coolft 4 Room dimensions ft166.0x1.0 5 Room area 2700.0 ft²166.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 530 375 1502 820 0 0 0 0 .GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 27 0 680 534 0 0 0 0 .GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 128 0 3226 2533 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 840 808 3237 1769 0 0 0 0 1 1 GG 10A-m10A-m 1.6701.670 ee 46.7646.76 51.9351.93 23 2 1060 1177 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 39.6239.62 9 2 227 357 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 590 536 2146 1173 140 140 561 306 GG 10A-m10A-m 1.6701.670 ss 46.7646.76 25.3125.31 24 48 1122 608 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ss 25.2025.20 19.7919.79 30 60 756 594 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 800 770 3083 1685 110 110 440 241 GG 1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 40.7040.70 30 4 756 1221 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 72 49 198 108 0 0 0 0 GG 10A-m10A-m 1.6701.670 nwnw 46.7646.76 42.9542.95 23 0 1060 974 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 2700 2700 4281 3694 166 166 263 227 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 2700 283 7841 0 166 25 692 0 6 c) AED excursion 0 -24 Envelope loss/gain 31174 17246 1956 751 12 a)Infiltration 4431 1187 391 105 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 15 3450 1 230 Appliances/other 3400 0 Subtotal (lines 6 to 13)35606 25283 2348 1085 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 35606 25283 2348 1085 15 Duct loads 16%16%5776 3940 16%16%381 169 Total room load 41381 29222 2728 1254 Air required (cfm)Air required (cfm)1367 1367 90 59 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:27:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 2...Documents\Wrightsoft HVAC\Charles Residence.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Toilet M WIC 2 2 Exposed wall 13.0 ft 3.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft5.0x8.0 ft84.0x1.0 5 Room area 40.0 ft²84.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 80 80 320 175 0 0 0 0 1 1 GG 10A-m10A-m 1.6701.670 ee 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 39.6239.62 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 50 50 200 109 30 30 120 66 GG 10A-m10A-m 1.6701.670 ss 46.7646.76 25.3125.31 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ss 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 40.7040.70 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 nwnw 46.7646.76 42.9542.95 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 40 40 63 55 84 84 133 115 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 40 13 360 0 84 3 83 0 6 c) AED excursion -8 -9 Envelope loss/gain 944 331 336 172 12 a)Infiltration 203 54 47 13 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)1147 385 383 414 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1147 385 383 414 15 Duct loads 16%16%186 60 16%16%62 65 Total room load 1333 445 445 479 Air required (cfm)Air required (cfm)44 21 15 22 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:27:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 3...Documents\Wrightsoft HVAC\Charles Residence.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name M WIC 1 M Bedroom 2 Exposed wall 8.0 ft 20.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft10.0x8.0 ft350.0x1.0 5 Room area 80.0 ft²350.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0 1 1 GG 10A-m10A-m 1.6701.670 ee 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 39.6239.62 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 ss 46.7646.76 25.3125.31 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ss 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 80 80 320 175 200 170 681 372 GG 1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 40.7040.70 0 0 0 0 30 2 756 1221 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 nwnw 46.7646.76 42.9542.95 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 80 80 127 109 350 350 555 479 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 80 8 222 0 350 20 554 0 6 c) AED excursion -12 476 Envelope loss/gain 669 273 2545 2548 12 a)Infiltration 125 34 313 84 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13)794 536 2858 3092 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 505 395 14 Subtotal 794 536 3363 3487 15 Duct loads 16%16%129 84 16%16%546 543 Total room load 923 620 3909 4030 Air required (cfm)Air required (cfm)30 29 129 189 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:27:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 4...Documents\Wrightsoft HVAC\Charles Residence.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Den Foyer 2 Exposed wall 13.0 ft 9.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft10.0x12.0 ft9.0x9.0 5 Room area 120.0 ft²81.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 30 30 120 66 0 0 0 0 1 1 GG 10A-m10A-m 1.6701.670 ee 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 39.6239.62 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 100 85 340 186 90 66 264 144 GG 10A-m10A-m 1.6701.670 ss 46.7646.76 25.3125.31 0 0 0 0 24 24 1122 608 GG 1A-r1ov1A-r1ov 0.9000.900 ss 25.2025.20 19.7919.79 15 15 378 297 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 40.7040.70 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 nwnw 46.7646.76 42.9542.95 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 120 120 190 164 81 81 128 111 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 120 13 360 0 81 9 249 0 6 c) AED excursion -26 -19 Envelope loss/gain 1389 687 1764 844 12 a)Infiltration 203 54 141 38 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1592 1201 1905 881 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1592 1201 1905 881 15 Duct loads 16%16%258 187 16%16%309 137 Total room load 1850 1388 2214 1019 Air required (cfm)Air required (cfm)61 65 73 48 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:27:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 5...Documents\Wrightsoft HVAC\Charles Residence.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Bedroom 3 WIC 3 2 Exposed wall 15.0 ft 27.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft12.0x12.0 ft6.0x12.0 5 Room area 144.0 ft²72.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 120 120 480 263 1 1 GG 10A-m10A-m 1.6701.670 ee 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 39.6239.62 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 120 105 420 230 60 60 240 131 GG 10A-m10A-m 1.6701.670 ss 46.7646.76 25.3125.31 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ss 25.2025.20 19.7919.79 15 15 378 297 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 30 30 120 66 90 90 360 197 GG 1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 40.7040.70 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 nwnw 46.7646.76 42.9542.95 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 144 144 228 197 72 72 114 99 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 144 15 415 0 72 27 748 0 6 c) AED excursion -28 -22 Envelope loss/gain 1562 761 1943 667 12 a)Infiltration 235 63 422 113 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 2 460 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)1797 1284 2365 1010 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 4 3 0 0 14 Subtotal 1801 1288 2365 1010 15 Duct loads 16%16%292 201 16%16%384 157 Total room load 2093 1488 2749 1168 Air required (cfm)Air required (cfm)69 70 91 55 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:27:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 6...Documents\Wrightsoft HVAC\Charles Residence.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Bath 3 Pantry 2 Exposed wall 13.0 ft 23.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft6.0x13.0 ft9.0x23.0 5 Room area 78.0 ft²207.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 130 121 484 265 230 230 921 503 1 1 GG 10A-m10A-m 1.6701.670 ee 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 39.6239.62 9 1 227 357 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 ss 46.7646.76 25.3125.31 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ss 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 40.7040.70 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 nwnw 46.7646.76 42.9542.95 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 78 78 124 107 207 207 328 283 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 78 13 360 0 207 23 637 0 6 c) AED excursion -17 -24 Envelope loss/gain 1195 711 1886 763 12 a)Infiltration 203 54 360 96 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)1398 766 2246 1089 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 5 5 4 3 14 Subtotal 1404 771 2250 1093 15 Duct loads 16%16%228 120 16%16%365 170 Total room load 1632 891 2615 1263 Air required (cfm)Air required (cfm)54 42 86 59 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:27:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 7...Documents\Wrightsoft HVAC\Charles Residence.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Bath 2 Laundry 2 Exposed wall 8.0 ft 32.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft8.0x8.0 ft128.0x1.0 5 Room area 64.0 ft²128.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 130 117 466 255 .GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 14 0 340 267 .GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 80 80 320 175 1 1 GG 10A-m10A-m 1.6701.670 ee 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 39.6239.62 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 ss 46.7646.76 25.3125.31 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ss 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 80 80 320 175 110 110 440 241 GG 1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 40.7040.70 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 nwnw 46.7646.76 42.9542.95 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 64 64 101 88 128 128 203 175 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 64 8 222 0 128 32 886 0 6 c) AED excursion -6 -37 Envelope loss/gain 643 256 2657 1076 12 a)Infiltration 125 34 501 134 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13)769 290 3157 1710 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 505 395 505 395 14 Subtotal 1273 685 3662 2105 15 Duct loads 16%16%207 107 16%16%594 328 Total room load 1480 792 4256 2433 Air required (cfm)Air required (cfm)49 37 141 114 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:27:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 8...Documents\Wrightsoft HVAC\Charles Residence.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Hall 1 Living Room 2 Exposed wall 9.0 ft 24.2 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft70.0x1.0 ft564.0x1.0 5 Room area 70.0 ft²564.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 30 30 120 66 170 42 168 92 .GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 128 0 3226 2533 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 60 37 149 82 0 0 0 0 1 1 GG 10A-m10A-m 1.6701.670 ee 46.7646.76 51.9351.93 23 1 1060 1177 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 39.6239.62 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 ss 46.7646.76 25.3125.31 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ss 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 40.7040.70 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 0 0 0 0 72 49 198 108 GG 10A-m10A-m 1.6701.670 nwnw 46.7646.76 42.9542.95 0 0 0 0 23 0 1060 974 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 70 70 111 96 564 564 894 772 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 70 9 249 0 564 24 669 0 6 c) AED excursion -26 -126 Envelope loss/gain 1690 1394 6215 4352 12 a)Infiltration 141 38 379 101 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 2 460 Appliances/other 0 900 Subtotal (lines 6 to 13)1831 1432 6594 5814 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -1831 -1432 316 247 14 Subtotal 0 0 6910 6061 15 Duct loads 16%16%0 0 16%16%1121 944 Total room load 0 0 8030 7005 Air required (cfm)Air required (cfm)0 0 265 328 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:27:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 9...Documents\Wrightsoft HVAC\Charles Residence.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Utility Kitchen 2 Exposed wall 27.0 ft 14.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft9.0x11.0 ft11.0x31.0 5 Room area 99.0 ft²341.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 90 90 360 197 110 97 386 211 .GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 14 0 340 267 .GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 110 110 440 241 0 0 0 0 1 1 GG 10A-m10A-m 1.6701.670 ee 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 39.6239.62 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 ss 46.7646.76 25.3125.31 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ss 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 70 70 280 153 30 30 120 66 GG 1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 40.7040.70 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 nwnw 46.7646.76 42.9542.95 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 99 99 157 135 341 341 541 467 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 99 27 748 0 341 14 388 0 6 c) AED excursion -18 -75 Envelope loss/gain 1986 708 1775 936 12 a)Infiltration 422 113 219 59 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 2 460 Appliances/other 0 2000 Subtotal (lines 6 to 13)2408 822 1994 3454 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 5 5 14 Subtotal 2408 822 2000 3459 15 Duct loads 16%16%391 128 16%16%324 539 Total room load 2799 950 2324 3998 Air required (cfm)Air required (cfm)92 44 77 187 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:27:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 10...Documents\Wrightsoft HVAC\Charles Residence.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Hall 2 2 Exposed wall 0 ft 3 Room height 10.0 heat/coolft 4 Room dimensions ft3.0x4.0 5 Room area 12.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh /ft²-°F)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 .G 1A-r1ov 0.900 n 25.20 19.79 0 0 0 0 .G 1A-r1ovd 0.900 n 25.20 19.79 0 0 0 0 .W 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 1 1 G 10A-m 1.670 e 46.76 51.93 0 0 0 0 G 1A-r1ov 0.900 e 25.20 39.62 0 0 0 0 W 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 G 10A-m 1.670 s 46.76 25.31 0 0 0 0 G 1A-r1ov 0.900 s 25.20 19.79 0 0 0 0 W 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 G 1A-r1ov 0.900 w 25.20 40.70 0 0 0 0 W 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 0 G 10A-m 1.670 nw 46.76 42.95 0 0 0 0 C 16X19-0md 0.408 -1.59 1.37 12 12 19 16 F 22A-tpl 0.989 -27.69 0.00 12 0 0 0 6 c) AED excursion 0 Envelope loss/gain 19 16 12 a)Infiltration 0 0 b)Room ventilation 0 0 13 Internal gains:Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13)19 16 Less external load 0 0 Less transfer 0 0 Redistribution -19 -16 14 Subtotal 0 0 15 Duct loads 16%16%0 0 Total room load 0 0 Air required (cfm)0 0 2021-Jun-09 12:27:59 Ri g ht-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 1 ...Documents\Wrightsoft HVAC\Charles Residence.rup Calc = MJ8 Front Door faces: S Job:Duct System Summary Date:Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com Project Information Charles ResidenceFor: 18900 Schumann Road, Fort Pierce, FL 34945 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.250 / 0.250 in H2O in H2O0.250 / 0.250 Lowest friction rate in/100ft0.250in/100ft0.250 Actual air flow cfm1367cfm1367 Total effective length (TEL)ft200 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st6135.059.0VlFx0x05.00.25837491480hBath 2 st5135.039.1VlFx0x05.00.28742541632hBath 3 st5135.038.2VlFx0x07.00.28970691488cBedroom 3 st3115.039.8VlFx0x07.00.32365611388cDen st3115.039.9VlFx0x06.00.32348732214hFoyer st1115.024.4VlFx0x08.00.359187773998cKitchen st6135.065.3VlFx0x07.00.2501141414256hLaundry st1115.029.6VlFx0x08.00.3461641333503cLiving Room st1115.022.0VlFx0x08.00.3651641333503cLiving Room-A st7135.059.7VlFx0x06.00.25759902728hM Bath st4115.043.4VlFx0x07.00.31694652015cM Bedroom st4115.047.9VlFx0x07.00.30794652015cM Bedroom-A st7135.058.9VlFx0x04.00.2582930923hM WIC 1 st7135.057.7VlFx0x04.00.2592215479cM WIC 2 st2115.011.5VlFx0x06.00.39559862615hPantry st7135.061.9VlFx0x05.00.25421441333hToilet st2115.010.5VlFx0x06.00.39844922799hUtility st5135.042.2VlFx0x06.00.28255912749hWIC 3 2021-Jun-09 12:27:59 Ri g ht-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 2 ...Documents\Wrightsoft HVAC\Charles Residence.rup Calc = MJ8 Front Door faces: S Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st7 Peak AVF 179 131 0.254 514 8.0 0x0 VinlFlx st4 st4 Peak AVF 308 319 0.254 586 10.0 0x0 VinlFlx st6 Peak AVF 189 151 0.250 543 8.0 0x0 VinlFlx st3 st3 Peak AVF 324 263 0.250 594 10.0 0x0 VinlFlx st1 Peak AVF 342 515 0.346 655 12.0 0x0 VinlFlx st5 Peak AVF 214 166 0.282 484 9.0 0x0 VinlFlx st2 st2 Peak AVF 393 269 0.282 500 12.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb1 0x 13670 1367 0 0 0 0 x0 0 VlFx