Loading...
HomeMy WebLinkAboutAPPROVED, 17-1104.07 ES EL100(1)ES Windows, LLC 3550 NW 49"' Street Miami, FL 33142 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami —Dade County RER— Product Control Section to be used in Miami —Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami --Dade County Product Control Section (In Miami —Dade County) and/ or the AHJ (in areas other than Miami —Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revolve this acceptance, if it is determined by Miami —Dade County Product Control Section that this product or material fails to meet the requirements ofthe applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "EL-100" Aluminum Single Hung Window — L.M.I. APPROVAL DOCUMENT: Drawing No. W16-57, titled "ES-EL100 Alum Single Hung Wdw. (L.M.I)", sheets 1 through 10 of 10, dated 07/13/16, with revision B dated 09/26/17, prepared by Al—Farooq Corporation, signed and sealed by Javad Abmad, P.E., bearing the Miami —Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami —Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, BARRANQUILLA, COLOMBIA S.A., series, and following statement. "Miami —Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami —Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 16-0510.22 and consists of this page I and evidence pages E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Jorge M. Plasencia, P. E. NOA No. 17-1114.07 Expiration Date: May 04, 2022 $` Approval Date: January 18, 2018 Page 1 ES Windows, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #16-0510.22 A. DRAWINGS L Manufacturer's die drawings and sections. 2. Drawing No. W16-57, titled "ES-EL100 Alum Single Hung Wdw. (L.M.I)", sheets through 10 of 10, dated 07/13/16, with revision A dated 04/21/17, prepared by Al— Farooq Corporation, signed and sealed by Javad Ahmad, P.E. Ifi1T�l K'! 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 along with marked -up drawings and installation diagram of aluminum single hung window, prepared by Blackwater Testing, Inc., Test Report No. BT-ESW-17-018, dated 03/31/17, signed and sealed by Constantin Bortes, P.E. 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202--94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, Test per FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of an aluminum single hung window, prepared by Architectural Testing, Inc., Test Reports No. F9504.01-450-18, dated 04/06/17 and revised on 04/25/17, signed and sealed by Justin P. McDonald, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC Stn Edition (2014), dated 04/12/17 and revised on 04/21/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). orge M. Plasencia, P. E. Prod det Control Unit Supervisor NOA No. 17-1114.07 Expiration Date: May 04, 2022 Approval Date: January 18, 2018 E-1 ES Windows, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Me. for their "Trosifol® Ultraclear, Clear, and Color PVB Glass Interlayer" dated 01/19/17, expiring on 07/08/19, 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on 07/04/18, 3. Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company (MA) for their "Saflex CP — Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 06/19/14, expiring on 11/11/181 4. Notice of Acceptance No. 14-0423.16 issued to Eastman Chemical Company (MA) for their "Saflex HP Clear or Color Glass Interlayers" dated 06/19/14, expiring on 04/14/18, F. STATEMENTS 1. Statement letter of conformance, complying with FBC 5t' Edition (2014), and of no financial interest, dated April 6, 2017, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. G. OTHERS 1. Distributor Agreement, dated 02/21/17, signed by Carlos Garcia (Cl Energia Solar SA) and by Evelyn Daes (ES Windows). 2. Test proposal # 16-0651mB, approved by RER. 2. NEW EVH)ENCE SUBMITTED A. DRAWINGS 1. Drawing No. W16-57, titled "ES-EL100 Alum Single Hung Wdw. (L.M.I)", sheets through 10 of 10, dated 07/13/16, with revision B dated 09/26/17, prepared by Al— Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS i. None. C. CALCULATIONS 1. None. E-2 orge M. Plasencia, P. E. Product Control Unit Supervisor NOA No. 17-1114.07 Expiration Date: May 04, 2022 Approval Date: January 18, 2018 ES Windows, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALFIYASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Interlayer" dated 12/28/17, expiring on 07/04/23. 2. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 09/07/17, expiring on 12/11/18. 3. Notice of Acceptance No. 17-0712.04 issued to Eastman Chemical Company (MA) for their "Saflex HP Clear or Color Glass Interlayers" dated 09/07/17, expiring on 04/14/18. F. STATEMENTS 1. Statement letter of conformance to FBC 5tn Edition (2014) and FBC 6t1 Edition (2017), dated 09/25/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. G. OTHERS 1. This NOA revises NOA #16-0510.22, expiring on 05/04/2022 ge M. Plasencia, P. E. ProduyAcontrol Unit Supervisor NOA No. 17-1114.07 Expiration Date: May 04, 2022 Approval Date: January 18, 2018 E-3 �118" TEMP. GLASS 71/8" TEMP. GLASS 3/8" AIR SPACE 1 5/16" AIR SPACE 1/8" HEAT STREN'D. GLASS 1/8" HEAT STREN'D. GLASS 1/8" HEAT STREN'D. GLASS 1/8" HEAT STREWD. GLASS .090' Interlayer .090" Interlayer .090" Interlayer 090" Interlayer Trosifo! PVB I Trosifol PVB Trosifof PVB Trosifo! PVB OR Kuraray America, Inc.' By R 'Kuraray America, Inc.' BByR'Kuroray Americo, Inc.' By 'Kuraray America, Inc.' 090" Interlcyer .090" Irterlayer .090" Interayer .090' Interlayer SeatryGlas SentryGlas 1 I SentryGlas SentryGlas By 'Kuraray America, Inc.' By 'Kuraray America, Inc.' By 'Kuraray America, Inc.' By 'Kuraray America, Inc.' �OR OR OR OR .090" Interlayer 090" Interlayer I 090" Interlayer I .090" Interlayer IScfleX Clear And Color Glass Saflex Clear And Color Glass �Saflex Clear And Color Glass Saflex Clear And Color Glass By 'Eastman Chemical Co: II By 'Eastman Chemica! Co.' By 'Eastmor! Chemical Co.' , By 'Eastmann. Chemical Co OR OR OR OR 075' Interloyer .075" Interlayer 075" Interlayer 1 .075" Interlayer ISaflex CP With PET Core Saflex CP With PET Core , Saflex CP With PET Core , Saflex CP With PET Core By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' By 'Eastman Chemical Co: 1 By 'Eastman Chemical Co.' r-if8" HEAT SIREN'D. GLASS 1/4" HEAT STREN'D, GLASS , I r1/8" HEAT STREN'D. GLASS 1/4" HEAT STREN'D. GLASS i' SILICONE SILICONE 1 I SILICONE , ` I SILICONE d ' I DOW CORNING 795 d j DOW CORNING 795 d !� , DOW CORNING 795 a: ' ! DOW CORNING 795 DOW CORNING 983 `DOW CORNING 983 �_ 1 I DOW CORNING 983 � I I DOW CORNING 983 in DOW CORNING 2400 a; 1 / DOW CORNING 2400 m //"DOW CORNING 2400 m DOW CORNING 2400 N I (HOT MELT) m ! / (HOT MET) M h / (HOT MELT) 5 N ` ,I (HOT MELT) a M1 M1 ! �g MP r _ M7 ` a \ iii l r IF 1 9 ' o I��i x E11 ir AT 1/4 POINTS ON UTES `l AT 1/4 POINTS ON L.'TES �W- w w M3 w ,rA3 w 4� AT i/4 POINTS x M4 AT 1/4 PO1 T WIDER THAN 36" ONLY WIDER THAN 36' ONLY \./ ALL SIZES �" ALL SIZES GLASS TYPE '1' GLASS TYPE '2' GLASS TYPE '1i' GIASS TYPE '2i' 5/16" OVERALL LAM. GLASS 7/16" OVERALL LAM. GLASS 7/8" OVERALL INSUL. LAM. GLASS 7/8" OVERALL MSUL LAM. GLASS ES—ELlOG GLAZING OPTIONS ALUMINUM SINGLE HUNG YONDOjM1' SEE SHEETS 2 AND 3 FOR DESIGN LOAD CAPACITY. APPROVAL APPLIES TC SINGLE UNITS OP. SIDE 8Y SIDE OGMBINATIONS WINDOW TYPES OF S.H./S.H. OP. IN MODULES OF SINGLE HUNG W,!TH OTH1=f? TWO OR MORE WINDOWS USING MI,AMI-DADE COUNTY APPROVED MULLIONS IN BETWEEN, LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2014 fSTH EDITION)/2C77 (BTH EDITION) FLORiDA BUILDING CODE INCLUDING HIGH VELOCTTY HURRICANE ZONE (HVHZ)_ 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND i^:SALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OP. STUCCO. A LOAD DURATION INCREASE 13 USED IN DESIGN OF ANCHORS INTO WOOD ONLY, ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON -COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2014/2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS.. THIS PRODUCT APPROVAL IS -GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DPAWING ARE TO BE ANALYZED SEPARATELY, .AND TO BE REVIEWED BY BUILDING OFFICIAL THESE WINDOW'5 ARE RAitD FOR LARGE tc SMALL MISSILE IMPACT. i SHUTTERS A,RE NOT REQUIP.ED. 5/16" & 3/8" AIR. SPACE CONSISTING OF: SPACER: `HEL!MA' LOW PROFILE ALUMINUM SPACER BY `LNGERMANN GMBH' kROUND THE PERIMETER OF THE G�SS. PERIMETER. SEALANT: SILICONE ^uGW COP.NING 791 GE 2000 PRODUC a Rc'VISED as complying with the Florida Building Code TaDA-No. 7 7-9'i'14.07 Expiration Date 05/04/2022 Control Miami -Dads Product i I e� of r �i: 'f IfC_I- I iIa a %��'•. f Al.EOV la =' �`f drawing na. � . °�7e�40'R1O1`••�\� � I W16-57 �`X f Lshee 53 1/8" 53 1/8" 53 1/8" w WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH !{4� 47 1 /2" �Y m D.L.O. (FIX. LITE) FALSE MUNTINS 14 Z n (SURFACE APPLIEv) MAX, 0 H, M 6" MAX. i 21" MAX. MAY BE USED S" MAX. Z7" MAX. 6" MAX. HEAD II HEAD I A HEAD A HEAD/SILL A Q$ Z a IL CORNERS f q HEAD CORNERS 6 HE`D ( CORNERS 7 0 O` o 0 E>> N m( IL W W r LID --�' ------ o u N ---�r-- _ - >- I D }0,� EL {0{-0 %d =---;r-----�r--- I �J tn � m Z fill' N h J 4 ii 0 1 Z '� o JZME vI n'o no j t.wmE �� o � � o �1 �� �v�`- z Z� E %/ Nxm i Nam of $ N W N b W— Q� \W (n \,TW \vW\vim S �`�C �Q I bi �o > > x Cj 0 J 3 0 I I I I L 4 ilzl of X G X mw a� G� I � �Im III J LLJ j X g Z z 4 E n o 6 tt 7 SMAX. cO m 7) o � 0 v vi ILL 47 1/2" o U ISO , n d D.L.O. (VENT) � ¢ I (] `' 1 7 50 1/B' Sfl 1/8" 50 1/8" z 21 c VENT WIDTH VENt WIDTH VENT WIDTH I o M I Uj In TYPICAL ELEVATION TYPICAL ELEVATION TYPICAL ELEVATION w _ �I EQUAL LITES EQUAL LiTES EQUAL LTcS r-I� FLANGE FRAMES FLANGE FRAMES WITH FLUSH ADAPTER FANGE FRAMES WITH RN ADAPTER I c�ji MAXIMUM DESIGN LOAD RATING = + 60,0 PSF I (FOR SIZES SHOWN ABOVE OR SMALLER) - $0.0 PSF o �I I STD. FRAME SILL MAXIMUM DESIGN LOAD P.ATINc = + 80,0 PSF (FOR SIZES SHOWN ABOVE OR SMALLER) - $D.D PSF 1 HI —RISE FRn1fi' SILT. FOR ALTERNATE SIZE UNITS MAX. FRAME .AREA OF WINDOW - I� NO TO EXCEED TESTED FRAME AREA OF 28.04 SQ. Ff. OP. 53-1/8" WIDTH. 1,, 1, PRODUCT REVISED o as complying with the Florida z f No. 70�2 Building Code (/ tt 17-111C:07 NOA-No. NOTE: �1 �,, V J�� GLASS CAPACITIES ON THIS SHEET ARE Expiration Date /04/2022n�'., q�- • 57A7E OF �� drowina no. BASED ON ASTM E1300-09 (3 SEC. GUSTS) By;a7epq.,•° per` I� �_�� AND FLORIDA BUILDING COMMISSION Nlia i-Dad roduct Control DECLARATORY STATEMENT DCA05—DEC-219 �i�sz6iyj; '- sheei 2 of 10 J% I B 4 i 1 II / II j --- ,r—rr--,r II ;� I I II ;I - It �� !! u I li II II I! j P B � 4 I .I NTlNS APPLIED; 5E0 53 1 /8" C C 0 TYFI�AL ELEVA??Onl UNEQUAL LfTES (ORIEL TYPE) FLANGE FRAMES TYPICAL ELEVATIOR' UNEQUAL LffES (ORIEL TYPE) FLP.NGE FRAME WITH FLUSH ADAPTER MAXIMUM DESIGN- LOAD RATING = -i- 6Q0 PSF {FOR SIZES SHOWN ABOVE OR SMALLER.) — 80,0 PSF L STD, FF.A_A E SZL MAXIMUM DESIGN LOAD RATING = + 80.0 PSF (FOP, SIZES SHOWN ABOVE OR SMALLER) — 80.0 PSF n^i-RISE FRA34B SIi OPERATING VENTS CAN 8E 1/2 TO 1J3 OF WINDOW HEIGHT MAX. D_L GPG. FOR FlX?J) LITE NOT TO EXCEED 15.7 SG. FT. FOR ALTERNATE SIZE UNITS MAX.. FRAME AREA OF WINDOW NOT TO EXCEED TESTED FRAME AREA OF 28.G4 SO, FT. OR 53-1/5" WIDTH. NOTE: GLOSS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 {3 SEC. GUSTS} AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05—DEC-219 v n 53 S 14" MAX. 7 HEAD I I I 11 �I II II %/ II 4 I if II I if 11 lid li � i I. I I S4' 7 I SILL LL 50 1/5" VENT WIDTH T AICAL ELQvIATION UNERJAL LITES (ORIEL TYPE) FL 4NGE FRAMES WITH FIN ADAPTER MAX.M i?StODUCT REVISED as complying with the Florida Suii�ng Catie NOA-No. If=I174,07 Expiration Date 05/04/2022d Mia- Da rouct Control o.70W2 GF , Z � m p m Z n ^L Z N Q `O U paoa�°+ 0 � ZNg_g J6md •I of z J J J ,yJ �I Y sl,vs�� F- ¢kO�r� I M ' O j Z �ICn 4� �l I alai � l�iz I o �Ic ryi v �a L m6m p (p ial I A�I,I i �I T 2 ( I Jil crewi O� no W16-57 1 O C TYPICAL ANCHORS ' SEE ELEV. Y FOR SPACING m EHGEa DIST, o 3 7 m a F—------- �, METAL �IrMIA-MI---DADS--- COUNTY--A-PPROVED I� STRUCTURE I MULLION & MULLION ANCHORS I1 I� SEE SEPARATE NCA �1 1 EDGE DIST. II I I� OPTIOiJAL TO SPRING LATCH > U ji I I i I m TYPICAL ANCN.ORS SEE ELEV. FOR SPACING TYPICAi ANCHORS SEE ELEV. FOR SPACING TNEEPHOLES: Wi = 1-3/S11 X 1/4" WEEPHOLES AT 4" FROM EACH END TYPICAL ANCHORS SEE ELEV. FOR SPACING WOOD BUCKS AND MCIAL STRUCTURE NOT BY E.S. WINDOWS z cm MUST SUSTAIN LOADS [IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCiiOFcS: sEE ELEv. FOR sPActtJc D[A. ULTRACON BY `ELCO' (Fu=177 KSI, Fy=155 KSI) iNTG 2BY WOOD BUCKS OR WOOD STRUCTURES MIN. PENETRATION INTO WOOD (HEAD/JAMBS) THRU 18Y BUCKS INTO CONC. OR BLOCKS MIN. EMBED INFO CONCRETE (HEAD/JAMBS) MIN. EMBED INTO BLOCKS (JAMBS)DIRECTLY INTO CONCRETE OR BLOCKS MIN. EMBED INTO CONCRETE (HEAD/JAMBS) MIN. EMBED INTO BLOCKS (JAMBS) IA- TEKS OR SELF DRILLING SCREWS (GRADE 5 CRS) NTO MIAMI—DADS COUNTY APPROVED MULLIONS OR N C METAL STRUCTURES (HEAD/JAMBS) (3) THR ADS MIN. PENETRATION BEYOND SUBSTRATE ALUMWUM: 1/8" THK. MIN. (6063—T5 MIN.) STEEL• 1 /8" THK_ MIN. (Fy = 36 KSI MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) TYPICAL EDGE DISTANCE INTO CONCRETE AND MASONRY = 2-1 / 2" MIN. IN+?G WGGD STRUCTURE = 1° MIN. _ INTO METAL STRUCTURE = 3/4" MIN. WGGD AT HEAD, SILL OR JAMBS SG = 0.55 MIN. CONCRETE ATI HEAD, SILL OR JAMBS fo = 3000 PSI MIN, C—SO HOLLI UK/FILLED BLOCK AT JAMBS = m = 2000 PSI MIN., PRO^UCT REMISED ` as complying with the Florida ?fie 70Sg2 8uiiding Code 1 wea-Ido. 17=1114.07 A Expiration Date 05104/202207 1— ` STATE OF ORID Miam'o-$a riod=t Control i� ups •••.. \� a _► m a zIUF- i zl � M u drawing no. WI 6-57 Iw 1 O D 1/4" MAX. M6 M6 E6 M18 M23 M22 3/S MAX Z m �- { M11 M19 M7 H1M5 it SHIM Q N g M73 M15 1. 0 p p co, w I J TYPICAL ANCHORS 0 W N ,I SEE ELEV. Q, a F m V FOR SPACING p I- o� Iri a r 1 1/2 r i ° m03 1 1/4t O'oZm o 0 '' ' I I OIL pal I MIAMI-DADE COUNTY O APPROVED MULLION n _ _ v SEE SEPARATE NOA �,2 __ p m EXTERIOR— / I / ( E4 E14 P D'u OPG. — _ _ 1BY I:� j I. I - - I 1 J WINDOW WIDTH WOOD BUCKS =— -- LTYPICAL ANCHORS SEE ELEV. x i FOR SPACING = - - 1C�10 'i w W _— ——��+�__ IIzs, � ` 1 TYPICAL ANCHORS N SEE ELEV, FOR SPACING m WINDOW WIDTH I WINDOW WIDTH. w z EOE a �<vi M 31 r-^A6) M22) W M6 1/4" MAX. `- �% M23 M15' . 1/4" MP,x. '' it SHIM \ SHIM S I I ' SEEPEICAvNCHORS22 Is�u�l t i . 4 ELE FOR SPACING I TYPICAL ANCHORS 1 ' SEE ELEV.� j _ .._.. ._.._ .._.._ _ _.. _ FOR SPACING 4` � � a. .�' -_ _._ �_.--- .__ .__ rz l j I v 41 SCREENOPT.-_-__--___J' ftt �I I/ p'.�. rr' jjjj c oLN G' Iva EXTERIOR�� C dq �0 M TA J #e e ` PRODUCT REVISED � r- WOOD BUCKS STRUCTURE 8 18 - r e as complying with the Florida �� �� Building Code z WINDOW WIDTH.NOA-No. 17-111.4.07 Expiration slat l04/2022— o® oiAMIE of •� By d'ZOR1Oa;°•°• ��: Miami- product Control °i e�� �N '` �+i 1 6-57 ' ON, es \� gigs pp144\\\ sheet cf 1C cnrc nicr SiRUC URE TYPICAL P.NCHORS SEE ELEV. FOR SPACING MIAMI-DADE COUNTY APPROVED MUWON & MULLION ANCHORS SEE SEPARATE NOA EDGE DIST. I TYPICAL ANCHORS SEE ELEV_ FOR SPACING 1l4" MAX. TYPICAL ANCHORS SEE ELEV. f"OR SPACING 'G O ALT. i7iaTALFATION i3ETALS I�'iTH FiIiSH FivAivLE ADAPTEF. ` ��:� gGEtia�°�� �:' SEE SHEETS 4 & 5 FOR WINDOW DETAILS PRODUCT REVISED ' 92 as complying with the Florida �'S Building. Code S NOA-No, 17-1114.07 0 Expiration Date M00412022 �® - STATE OF DN y ` mia i- roduct Control 1l19i11�,�� vl 1'I t] � � v I Z 6 ~Ly C,i Z( m 0 nl II al �1I�IIz� drewinc no. vv� 6-57 i ILLUSTRATNE DTLS. ONLY EXT. OR INT. FINISHES NOT BY E.S. WDW. �J ALT. ALT. TYPICAL ANCHORS SEE ELEV. FOR SPACING z_ � z a Q10 TEKS/SELF DRILL'NG SCREWS AT 6 FROM ENDS Ai1D 12 O.C. MAX. �10 TEKS/SELF DRILLING SCRE`NS AT 6 FRCM ENDS AND 12 O_C. MAX. TYPICAL ANCHORS SEE ELEV. 'OR SPACING TYPICAL ANCHORS: SEE ELEV. FOR SPACING )4 WOOD SCREWS (GRADE 2 CRS) IN70 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN, PENETRATION INTO WOOD 1/4" MAX. MIN. TYPICAL ANCHORS D ALT. �10 It�.S/$GLF DP.ILLiNG SCREWB AT 6 FROM ENDS AND 12 O.C. MAX. E�`I`ER=OR u INS'I'_ALL_�TION LE'IAILS KITH FIN FR= 1,yi AJA?'TER SEE SH �� 4 &5 FOR WINDOW DETAIa p�®DUCT REV}SED z < as complying with the Florida- Building Code NOA-No. 7-9114.07 N \i Expiration Cate -/04/2022 By M p 3 o ^ z = U wII J j = w � � z 17 J Z O m��� fSYAaEOF = 1 % drawing no. W16-57 sheet 7 of 00 U 7 ro �% J 0� 0 z o- a Q� gcrioi a (L ? o �oo`m of N aW O H a 0hh ci C ui d SYm °o 0 N W h O �y� not M `( YZI Cm} F m Ii 1 n 0 I (i �I I J J w i zry V) V) C) i < o` i Z 3 J 7 Z LL o f M � I L� Ln i w i I!W..i g:� it �I I �J N' cic olw i IiII a 2 ijll!� f z Iloc61 'm j I PRODUCT REVISED `\ as complying with the Florida Building Code a �G, 70592 t NOA-No. 17-1114.07 S' jI Expiration Date 05/04/2022 STATE OF dmwir Nis t- Product Control 0. f; zoFt1O9'.• ° ��: t �V ���.� ,�'16-57 ZONAL ��Uisltltt� sheet 8 of 10j TTRir � PART � REQD. DESCRIPTION MdTF.RL4L hfA.\*P./SDPPLI&R/REMARKS El ES-EL107A 1 FRAME HEAD 6063-Tb - £2 ES-EL1 C2 1 FRAME SILL (STANDARD) 6063-76 - E3 ES-ELi03 1 FRAME SILL (HI -RISE} 6083-76 - E4 ES-EL704 2 FRAME JAMB 6063-Tfi - E5 ES-EL705 1 VENIT TOP RAI! 6063-T6 - E6 ES-EL?05 1 VENT BOTTOM RAIL 6063-T6 - E7 ES-EL107 2 VENT SIDE RAIL 6063-Tfi - E8 ES-EL108A i 1 FIXED MITG. RAIL 6063-T6 - E9 ES-c�109 AS ROD. GLAZING BERG (5/16" LAM. GLASS) 60b3-T6 { - E10 ES-fL110 AS ROD. GLAZING BEAD (7/16" LAM. GLASS) 6063-T6 - E11 ES-EL11'r AS ROD. GLAZING BEAD (INSUL LAM. GLASS) 6063-T6 - E72 I ES-EL712 AS REOD. FLUSH FRAME ADAPTER 6063-T6 - E13 ES-EL173A AS P.EOD. HEAD SCREW COVER 60"o3-T6 - E14 £5-EL114 AS REOD. JAMS SCREW COVER 6063-T6 - E75 ES-El ASftEOD. � FLUSH FRAME ADAPTER WTf}f FIN 6063-T6 - M1 ES-SOGBA AS REgD. GLAZING BEAD BULB ` SWCONE DUROMEiER 65s5 SHORE A M2 - �100-GOt AS REOD. VENT BOTTOM GASKET � EPDM DURGMETER 55t3 SHORE A M3 80-372A 2/ LITE SETTING BLOCK AT if4 POINTS (LAM. GLASS) I SILICONE DUROMETER80�6 SHORE A M4 'eLtOG-.E01 I 2f LffE SETTING BLOCK AT 1/4 POINTS (INSUL LAM. GLASS)I SILICONE DUROMETER 80t5 SHORE A MS g300T790 AS REOD. O-LONZ WEATHER SEAL AT SILL URETHANE FOAM ! - i M6 � 23271 NG i AS REOD. PILE W'STR!PP1NG Wlh! PLASTIC FIN POLYPROPYLENE - ! M7 f5-Et1i5 4/ VENT VENT TOP GUIDE (SPIRAL BALANCE} I CELCON - M8 ES-EL176 2/ VENT VENT TOP GUIDE (BLOCK & TACKLE BALANCE) E C£LCON - M9 SKOB-4010 2/ VENT SPRING LOADED LATCH � 6063-T6 � ALTERNATE TO SWEEP LATCH M70 ES-1012 2/ LATCH LATCH SPRING Si. STEEL - M71 SL302-XX 2f VENT SWEP LATCH DIE CAST ALUM - M12 FAS255129 2 WEEP HOLE COVER NYLON - M13 SERIES 85 2/VENT � BLOCK &TACKLE EALANGf CRS - M14 15P19 i 2,NENT BALANCE TAKE OUT CHIP i ST. STEEL - M15 - 2/VENT SPIRAL BALANCE CLASS 6 CPS - M16 21603 - NON TILT Si. SEEL - f M77 ES-004 2 -VENT GUIDE NYLON - M78 ES-iC00-P1L - LEFT NOTCH CAP NYLON - Mi9 ES-1C00-FIR - RIGHT NOTCH CAP NYLON � - MI20 PttJDIENTE - SASH STOP- M21 �e X 1' - FLUSH FRAME ADAPTER ASSEMBLY FASTENERS 5"�. STEEL FH SMS M22 I II �8 X 1" k - FRAME AND `LENT ASSEMBLY FASTENERS ST. STEEL PH SMS Mti j �10 X t-1/4'SPIRAL BALANCE ASSEMBLY FASTENERS ST. STEEL FH SMS M24 I �6 X 1 f2' V-_T'T GUIDE ASSEMBLY FASTENERS i SF. STEEL -'; SMS --M25 � M25 �8 X 3/4' i8 X ]; 2' - - i SWEEP LATCH FASTENERS "i0N TILT FtiTE�tERS ST. S'f-u1 ST. 5T<� FH SMS PH SMS 1 2 FRAME HEAD RX. MEET;NG RAIL VEN?' TOP RAL VENT BCTf'vM PAIL i9 0 i! FRAME JAMB O FRAME SILL (SANDARD) E3 FRAME SILL (H?-RISE) —.040 ,277 '—r 1.740 —q HFAD SCREW COVER F�- 1.187 i .040 625 i -d .683 I�- VENT SIDE RAIL JAMB SCREW CCVER 2.857 —j r-.045 500 —7 .625 �k2.780—�i i7 � �e12J FLUSH FRAME ADAPTER 1 FLUSH FRAME ACAPTEP. WITH FIN SPRING LOADED LATCH E33 F MO974 I G^g, a Sao 625 n. .050 .9I 8 .202 Et0 GLAZING BEADS PRODUCT REVISED as complying with the Florida Suiiding Code tvoa No. i7-1114.07 Expsration Date 5/04/2022 Maanii !aWe Product Control li w l it c� n � z n � N V w n ! g' (fSdAsO;' ,CfS 1 drawing no. 11 isheet 10 of VENT TOP CORiJER VENT BOTTOM CORNER FRAME TOP CORNER FRAME BOTTOM CORNER FiN FRAP�IE ADAPTER CORNER Pi2DDUCT REVISED as complying with the Florida Building Code NOA-Na° 17-11 Uv07 Expiration Dat 5104/2022 By �� lNiami-Da Product Control n A 31 o! � � � o � z i M � drawing na. I W16-57 1i