HomeMy WebLinkAbout21-0876-FORMBOARD-24x36 SignedTWO STORYRESIDENCE #6740PUBLIC WATERFF EL=17.36GARAGE EL=12.06FORMBOARD LOCATIONTOP EL= 12.30'SURVEYORS NOTES:1. LEGAL DESCRIPTION PROVIDED BY CLIENT. ADJOINERS SHOWN HAVE NOT BEEN SURVEYED.2. NO UNDERGROUND FOUNDATIONS HAVE BEEN LOCATED3. LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR RIGHT-OF-WAY AND/OR EASEMENTS OF RECORD.4. SEPTIC TANKS AND WELLS IF SHOWN ARE APPROXIMATE LOCATIONS AND SHOULD BE FIELD VERIFIED BY A LICENSEDCONTRACTOR FOR CORRECT POSITION AND SEPARATION. UNDERGROUND UTILITIES OR FOOTERS HAVE NOT BEEN LOCATED.5. THE WESTERLY R/W LINE OF NORTH HIGHWAY A1A IS ASSUMED TO BEAR N 19°14'02" W AND ALL OTHER BEARINGS ARERELATIVE THERETO.6. ALL RIGHTS-OF-WAY SHOWN HEREON ARE OPEN TO TRAVEL UNLESS OTHERWISE NOTED.7. ACCORDING TO THE NATIONAL FLOOD INSURANCE RATE MAP NUMBER 12111C0087K, HAVING AN EFFECTIVE DATE OFFEBRUARY 19, 2020. THIS PROPERTY APPEARS TO LIE WITHIN ZONE AE (BASE FLOOD ELEVATION=11.0'), INSIDE SPECIAL FLOODHAZARD AREA.8. ALL DISTANCES SHOWN HEREON ARE HORIZONTAL GROUND DISTANCES AND ARE REFERENCED TO U.S. SURVEY FEET.9. THE BOUNDARY DETERMINATION AND DELINEATION SHOWN ON THIS MAP OF SURVEY WAS BASED UPON THE PROFESSIONALOPINION OF THE REGISTERED SURVEYOR PURSUANT TO NORMAL PRINCIPALS AND PRACTICES OF LAND SURVEYING AND ISNOT INTENDED TO IMPLY OR DETERMINE OWNERSHIP. THIS SURVEY DOES NOT INTEND TO DELINEATE LOCAL AREAS OFCONCERN OR ANY OTHER JURISDICTIONAL DETERMINATION.10. THIS SURVEY HAS BEEN PREPARED FOR THE EXCLUSIVE BENEFIT AND USE OF THE PERSONS AND/OR ENTITIES NAMEDHEREON FOR THE PURPOSES IDENTIFIED HEREON ONLY. UNLESS OTHERWISE STATED, CERTIFICATION OF THIS SURVEY MAPAPPLIES ONLY TO THE STANDARDS OF PRACTICE SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS ANDMAPPERS IN CHAPTER 5J17 FLORIDA ADMINISTRATIVE CODE, PURSUANT TO SECTION 472.027, FLORIDA STATUTES. THECERTIFICATION IN NO WAY CONSTITUTES NEITHER GUARANTY NOR WARRANTY TO ANY OTHER INFORMATION NOT SHOWNHEREON. ADDITIONS, DELETIONS OR REVISIONS TO THIS DRAWING BY OTHERS ARE NOT PERMITTED AND THIS SURVEY MAYNOT BE TRANSFERRED WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THE SIGNING SURVEYOR. THIS SURVEY IS NOTVALID FOR ANY OTHER PURPOSE OTHER THAN INTENDED BY THE SIGNING SURVEYOR.11. ELEVATIONS, IF SHOWN, ARE BASED UPON THE NORTH AMERICAN VERTICAL DATUM 1988.X = STREET LIGHT = LIGHT POLE = EXISTING ELEVATION = PROPOSED ELEVATION = IRON ROD = CATCH BASIN = CABLE PEDESTAL = WOOD UTILITY POLE = GUY ANCHOR = ELECTRIC TRANSFORMER = TELEPHONE JUNCTION BOX = WATER METER = FIRE HYDRANT = WATER VALVE = EXISTING WELL = SANITARY MANHOLE = STORM MANHOLE = CHAIN LINK FENCE = WOOD BOARD FENCE = TOP OF BANK = TOE OF SLOPE = OVERHEAD WIRES = BUILDING SETBACK LINEFIP = FOUND IRON PIPE "NO IDENTIFICATION"SIRC = SET 1/2" IRON ROD WITH CAP "LB 8006"CONC = CONCRETEFN&D = FOUND NAIL AND DISKSN&D = SET NAIL AND DISKFF EL.= FINISHED FLOOR ELEVATIONS/T = SEPTIC TANKSF = SQUARE FOOT(P) = PLAT (D) = DEED (M) = MEASUREC/L = CENTERLINE EOP= EDGE OF PAVEMENTCMP = CORREGATED METAL PIPEP.R.M.= PERMANENT REFERENCE MONUMENTEL = ELEVATIONBM = SITE BENCHMARKC.B.S. = CONCRETE BLOCK STRUCTURECB = CHORD BEARINGPCP = PERMANENT CONTROL POINTPC = POINT OF CURVATUREPT = POINT OF TANGENCYR/W = RIGHT OF WAYFIR = FOUND IRON ROD "NO IDENTIFICATION"FIRC = FOUND IRON ROD WITH CAPLEGENDADDRESS:6740 NORTH HIGHWAY A1AFORT PIERCE, FL 34949CERTIFIED TO:DARLING CONSTRUCTIONGSS SURVEYING & MAPPING, LLC.CERTIFICATE OF AUTHORIZATIONNUMBER LB 8006PROFESSIONAL SURVEYOR AND MAPPER IN RESPONSIBLE CHARGETERRY H. DRUM PROFESSIONAL SURVEYOR AND MAPPER NO. 5597 ORHENRY A. KILBURN, PROFESSIONAL SURVEYOR AND MAPPER NO. 6661NOT VALID WITHOUT THE ORIGINAL SIGNATURE AND RAISED SEAL ORDIGITAL SIGNATURE AND DIGITAL SEALOF A FLORIDA LICENSED SURVEYOR AND MAPPER.CONTROLLING BENCHMARKNATIONAL GEODETIC SURVEYPID DI3911PUBLISHED ELEVATION 17.70 NAVD 1988