HomeMy WebLinkAboutReviewed, ok from zoning,PV Engineering Plans 001.3ROOF AREA EXISTING SHINGLE ROOF TOTAL ROOF AREA: 3,574 sq.-ft TOTAL PHOTOVOLTAIC AREA: 774 sq.-ft PERIMETER WIDTH: 4.3’ PRESSURE ZONE: 1 & 2 MEAN ROOF HEIGHT: 14’ ROOF SLOPE: 3:12 TOTAL MODULES: 39 MIN. ROOF MOUNTS: 80 TOTAL POINT OF CONNECTIONS PER MODULE: 4 ALUMINUM RAILS: 2 4'-0"2'-0" SOLAR MODULE TYP. ROOF MOUNTS TYP.4'-0"2'-0"4'-0"MOUNT LAYOUT ALUMINUM ROOF MOUNTS MEASUREMENTS ALUMINUM RAIL MEASUREMENTS SPACING 8 21 7 3 5 6 4 PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN NEC 690.12 PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS PHOTOVOLTAIC MICROINVERTERS LOCATED UNDERNEATH PV MODULE ON ROOFTOP ARRAY FOR SERVICE PLEASE CALL (PV COMPANY#) LABEL FOR SOLAR AC COMBINER BOX LABEL SIZE: 4” x 2” LABEL FOR EACH J-BOX LABEL SIZE: 4” x 2” LABEL FOR SOLAR DISCONNECT LABEL SIZE: 4” x 2” LABEL FOR SOLAR DISCONNECT LABEL SIZE: 4” x 2” LABEL FOR SOLAR AC COMBINER BOX LABEL SIZE: 5-1/2” x 2” LABEL FOR SOLAR CIRCUIT BREAKER INSTALLED IN MDP LABEL SIZE: 2” x 1 LABEL FOR MAIN DISTRIBUTION PANEL LABEL SIZE: 4” x 1” LABEL FOR MAIN DISCONNECT OR METER LABEL SIZE: 4” x 2” PHOTOVOLTAIC POWER SOURCE AC OPERATING VOLTAGE 240VOLTS AC OPERATING CURRENT AMPS AC OPERATING VOLTAGE VOLTS AC OPERATING CURRENT AMPS MICROINVERTERS LOCATED UNDERNEATH MODULES FOR SERVICE CALL (PV COMPANY #) NOTE: INSTALLER MUST FILL IN AC OPERATING CURRENT ON LABEL. NOTE: INSTALLER MUST FILL IN AC OPERATING CURRENT ON LABEL. CAUTION SOLAR POINT OF CONNECTION PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE SAFETY LABELS WARNING DUAL POWER SUPPLY SOURCES: UTILITY AND PV SOLAR ELECTRIC SYTEM PHOTOVOLTAIC SYSTEM AC DISCONNECT NOTE FOR ALL LABELS: LABELS SHALL BE UV RESISTANT AND SHALL HAVE WHITE LETTERS ON A RED BACKGROUND. SHARPIE EXTREME OR EQUIVALENT UV RESISTANT MARKERS SHALL BE USED FOR WRITING ON LABELS REQUIRING INSTALLER-WRITTEN VALUES. REVISIONS: DRAWN BY: J.B PAGE: S-1 SYSTEM LAYOUTSCALE: NTS ROOF PLAN N SEAL:METERMDP DISC SOLAR MDP MANUEL E. SIQUES, P.E.FLORIDA ENGINEER LICENSE # 202338331 SW 12TH TERRACE,MIAMI, FL 33144.A, 33144TEL (305) 586-4776I CERTIFY THAT THIS PV SYSTEM FULLY COMPLIES WITH THE REQUIREMENTS OF NEC 690. NOTE: ALUMINUM RAILS SHOULD ALWAYS BE SUPPORTED BY MORE THAN ONE FOOTING ON BOTH SIDES OF THE SPLICE." at the end of each row of modules. NOTE: Install mid clamps between modules and end clamps SOLAR MODULE 39.4” Q CELL 315W 66.3”MAX. PRESSURE RATING 83.54PSF Green Solutions of Florida LLC355 S Ronald Reagan Blvd,Longwood, FL 32750(407) 247-11693FT FIRE PATHWAY Project: Roderick Wright894 Woodlands Dr, Port St. Lucie, FL 3495273'-7 1/2"39'-1 1/2"23'-2 1/4"19'-7"14'-7 1/2"21'-2 3/4"19'-9"49'-7 3/4"60'-10 1/2"24'-2 1/2"12'-5 3/4"9'-0 3/4"11'-8 1/4"19'-5 1/2"18'-4 1/2"14'-6 1/2"20'-4"1 7 ' - 6 3 / 4 "2'-1 1/4"12'-1 1/4"3'-4 1/4"14'-6 1/2"DATE: 10/14/2021