HomeMy WebLinkAboutReviewed, ok from zoning,PV Engineering Plans 001.3ROOF AREA
EXISTING SHINGLE ROOF
TOTAL ROOF AREA: 3,574 sq.-ft
TOTAL PHOTOVOLTAIC AREA: 774 sq.-ft
PERIMETER WIDTH: 4.3’
PRESSURE ZONE: 1 & 2
MEAN ROOF HEIGHT: 14’
ROOF SLOPE: 3:12
TOTAL MODULES: 39
MIN. ROOF MOUNTS: 80
TOTAL POINT OF CONNECTIONS PER MODULE: 4
ALUMINUM RAILS: 2
4'-0"2'-0"
SOLAR MODULE TYP.
ROOF MOUNTS TYP.4'-0"2'-0"4'-0"MOUNT LAYOUT
ALUMINUM ROOF MOUNTS MEASUREMENTS
ALUMINUM RAIL MEASUREMENTS SPACING
8
21
7
3
5 6
4
PHOTOVOLTAIC SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
NEC 690.12
PHOTOVOLTAIC SYSTEM
COMBINER PANEL
DO NOT ADD LOADS
PHOTOVOLTAIC MICROINVERTERS
LOCATED UNDERNEATH
PV MODULE ON ROOFTOP ARRAY
FOR SERVICE PLEASE CALL (PV COMPANY#)
LABEL FOR SOLAR AC COMBINER BOX
LABEL SIZE: 4” x 2”
LABEL FOR EACH J-BOX
LABEL SIZE: 4” x 2”
LABEL FOR SOLAR DISCONNECT
LABEL SIZE: 4” x 2”
LABEL FOR SOLAR DISCONNECT
LABEL SIZE: 4” x 2”
LABEL FOR SOLAR AC COMBINER BOX
LABEL SIZE: 5-1/2” x 2”
LABEL FOR SOLAR CIRCUIT BREAKER
INSTALLED IN MDP
LABEL SIZE: 2” x 1
LABEL FOR MAIN DISTRIBUTION PANEL
LABEL SIZE: 4” x 1”
LABEL FOR MAIN DISCONNECT OR METER
LABEL SIZE: 4” x 2”
PHOTOVOLTAIC POWER SOURCE
AC OPERATING VOLTAGE 240VOLTS
AC OPERATING CURRENT AMPS
AC OPERATING VOLTAGE VOLTS
AC OPERATING CURRENT AMPS
MICROINVERTERS LOCATED UNDERNEATH MODULES
FOR SERVICE CALL (PV COMPANY #)
NOTE: INSTALLER MUST FILL IN AC OPERATING CURRENT
ON LABEL.
NOTE: INSTALLER MUST FILL IN AC OPERATING CURRENT
ON LABEL.
CAUTION
SOLAR POINT OF CONNECTION
PV SOLAR BREAKER
DO NOT RELOCATE
THIS OVERCURRENT
DEVICE
SAFETY LABELS
WARNING
DUAL POWER SUPPLY
SOURCES: UTILITY AND
PV SOLAR ELECTRIC SYTEM
PHOTOVOLTAIC SYSTEM
AC DISCONNECT
NOTE FOR ALL LABELS:
LABELS SHALL BE UV RESISTANT AND SHALL
HAVE WHITE LETTERS ON A RED BACKGROUND.
SHARPIE EXTREME OR EQUIVALENT UV RESISTANT
MARKERS SHALL BE USED FOR WRITING ON LABELS
REQUIRING INSTALLER-WRITTEN VALUES.
REVISIONS:
DRAWN BY: J.B
PAGE:
S-1 SYSTEM LAYOUTSCALE: NTS
ROOF PLAN
N SEAL:METERMDP
DISC
SOLAR MDP
MANUEL E. SIQUES, P.E.FLORIDA ENGINEER LICENSE # 202338331 SW 12TH TERRACE,MIAMI, FL 33144.A, 33144TEL (305) 586-4776I CERTIFY THAT THIS PV SYSTEM FULLY COMPLIES WITH THE REQUIREMENTS OF NEC 690. NOTE:
ALUMINUM RAILS SHOULD ALWAYS BE SUPPORTED BY MORE THAN
ONE FOOTING ON BOTH SIDES OF THE SPLICE."
at the end of each row of modules.
NOTE: Install mid clamps between modules and end clamps
SOLAR MODULE
39.4”
Q CELL
315W 66.3”MAX. PRESSURE RATING 83.54PSF
Green Solutions of Florida LLC355 S Ronald Reagan Blvd,Longwood, FL 32750(407) 247-11693FT FIRE PATHWAY Project: Roderick Wright894 Woodlands Dr, Port St. Lucie, FL 3495273'-7 1/2"39'-1 1/2"23'-2 1/4"19'-7"14'-7 1/2"21'-2 3/4"19'-9"49'-7 3/4"60'-10 1/2"24'-2 1/2"12'-5 3/4"9'-0 3/4"11'-8 1/4"19'-5 1/2"18'-4 1/2"14'-6 1/2"20'-4"1
7
'
-
6
3
/
4
"2'-1 1/4"12'-1 1/4"3'-4 1/4"14'-6 1/2"DATE: 10/14/2021