HomeMy WebLinkAboutAPPROVED BY WALTER PRIDE, Heffelfinger Residence E-01 SEALEDREVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-01COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST,
FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590ELECTRICALLINE DIAGRAMSOLAR ARRAY (10.800 kW-DC STC)(27) CANADIAN : CS1Y-400MS (400W) MODULES(03) BRANCHES OF 09 MODULESNOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2020, INCLUDING MAXIMUM NUMBEROF MODULE STRINGS, MAXIMUM NUMBER OF MODULES PERSTRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODELNUMBER, INVERTER MANUFACTURER AND MODEL NUMBER, ASAPPLICABLE.2. MID INTERCONNECTION PER 705.12(A) & 705.170, AND COMPLIANTWITH NEC 690.10, 690.71, AS WELL AS 705.12(B)(2)(3)(e).1ELECTRICAL LINE DIAGRAME-01SCALE: NTS(N) SOLADECK600V, NEMA 3RUL LISTEDGGGGGGGGGGGGGGGGGGENPHASE: IQ7A-72-2-USMICROINVERTERSPV MODULESQ CABLESGGGGGGGGG#6 BARE CU WIRE PROTECTED PER NEC 250.64(B)NGL1L1L2L2L1L2NNGL2L1L2L1GL2L1L2L1L1L2NN(E) MAIN DISTRIBUTION PANEL200A RATED, 240VGTO UTILITY GRIDL1L2NBI-DIRECTIONALSERVICE POINT ANDUTILITY METERING1-PHASE, 240VL1L2N(N) MAIN SERVICEDISCONNECT200A/2P, 240V(N) TESLA BACKUP GATEWAY 2AUTOMATIC TRANSFER SWITCHMICROGRID INTERCONNECTDEVICE (MID) UL LISTED,SER RATED 240V, 200A RATED(3) #10 AWG THWN-2 - RED(3) #10 AWG THWN-2 - BLACKEGC #10 AWG THWN-2IN 3/4" PVC, IMC, RMC, FMC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT OR ENTCONDUIT RUN(3) #2/0 AWG THWN-2 CUIN 2" PVC OR EMTCONDUIT RUNSER PER NEC 310.15(B)(7)MIN. 6'NEW OR EXISTING GROUNDINGELECTRODE SYSTEM#4 AWG THWN-2 GND BONDEDTO (2) 1/2" X 8' GND RODS MIN 6'APART PER NEC 250.53(3) #2/0 AWG THWN-2 CU(1) #6 AWG THWN-2 GNDIN 2" PVC OR EMTFEEDER PER NEC310.15(B)(7)(E) MAIN BREAKER200A/2P, 240VL2L1NL2L1GN20A/2PG15AL2L120A/2PG(3) #2 AWG THWN-2(1) #6 AWG THWN-2 GNDIN 1-1/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNL2L120A/2P (N) GENERATION PANEL200A RATED, 204VL2L130A/2PL2L130A/2PL2NL1GL2NL1G(N) (02) TESLAPOWERWALL 25kW CONTINUOUSPOWER 13.5kWhSTORAGEN(3) #10 AWG THWN-2(1) #10 AWG THWN-2 GNDL2L1NGL2L1NG(N)ALTERNATIVE POWERSOURCE AC DISCONNECT:240V, 60AMP RATED,NEMA 3R, UL LISTED LOCKABLE & FUSIBLEWITH 50A FUSES(3) #6 AWG THWN-2IN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN