Loading...
HomeMy WebLinkAboutHealth department approvalSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: RA Construction Corp FG the TC/Homes By A Burton AGENT: Richard Adams III PROPERTY ADDRESS: 51 Sovereign Way Fort Pierce, FL 34949 APPLICATION #:AP 155464 PERMIT # : 56-S F-2141736 DOCUMENT #:F11720440 DATE PAID:08/27/2020 FEE PAID:545.00 RECEIPT #:56-PID-4591276 LOT: A&B BLOCK: 2 SUBDIVISION: Queens Cove ID#: 1414-401-0013-000-0 CHECKED [X) ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ 1 [011 TANK SIZE [11 1050.00 [21 300.00 [ 1 [271 SURFACE WATER 50 FT [ 1 [021 TANK MATERIAL Concrete [ 1 [281 DITCHES FT [ j [031 OUTLET DEVICE [ j [291 PRIVATE WELLS FT [ ) [041 MULTI -CHAMBERED [ Y N ) [ ) [301 PUBLIC WELLS FT [ ) [051 OUTLET FILTER PolylokPL-122 [ j [311 IRRIGATION WELLS FT [ ) [061 LEGEND 1. 01-011-09DC3 2. 01-011-96SC4 [ 1 [321 POTABLE WATER 6 FT [ j [071 WATERTIGHT [ ) [331 BUILDING FOUNDATIONS 5 FT [ ) [081 LEVEL [ ) [341 PROPERTY LINES 15 FT [ ) [091 DEPTH TO LID [ 1 [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ 1 [101 AREA Ill 672 [21 SQFT [ 1 [361 DRAINFIELD COVER [ ) [111 DISTRIBUTION BOX HEADER X [ ) [371 SHOULDERS [ 1 [121 NUMBER OF DRAINLINES 1. 7.00 2. [ ) [381 SLOPES [ 1 [131 DRAINLINE SEPARATION [ j [391 STABILIZATION [ 1 [141 DRAINLINE SLOPE [ 1 [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ) [161 ELEVATION [ ABOVE / BELOW ]BM 7.00 [ 1 [401 UNOBSTRUCTED AREA [ ) [171 SYSTEM LOCATION [ ) [411 STORMWATER RUNOFF [ ) [181 DOSING PUMPS 1.00 [ 1 [421 ALARMS [ 1 [191 AGGREGATE SIZE [ 1 [431 MAINTENANCE AGREEMENT [ 1 (201 AGGREGATE EXCESSIVE FINES [ ) [441 BUILDING AREA [ ) [211 AGGREGATE DEPTH [ 1 [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL, [ 1 [461 FINAL SITE GRADING [ 1 [471 CONTRACTOR John Baker (Accurate Septic [ 1 [221 FILL AMOUNT [ 1 [481 OTHER [ j [231 FILL TEXTURE [ 1 [241 EXCAVATION DEPTH ABANDONMENT [ j [251 AREA REPLACED [ ) [491 TANK PUMPED [ 1 [261 REPLACEMENT MATERIAL [ ) [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION I APPROVED St. Lucie CHD DATE: 08/03/2021 DISAPPROVED � ' Enviro ental Specialist I e ajanyi (Florida Department of He FINAL SYSTEM [ APPROVED / DISAPPROVED 3 • St. Lucie CHD DATE: 11/02/2021 nvironmen al Specialist I Ma a nyi (Florida Department of H (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1554640 EID2141736 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT CONSTRUCTION INSPECTION Violation Number Comment Comments AND DISPOSAL SYSTEM AND FINAL APPROVAL APPLICATION #:AP 1554640 PERMIT #:56-SF-2141736 DOCUMENT # : FI 1720440 DATE PAID : 08/27/2020 FEE PAID:545.00 RECEIPT #:56-PID-4591276 The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400 gpd. New ST, DT, Barnes 1/3 hp pump, and 7x8 long BED DF installed. No violations, system ok to cover. Contractor notified by phone. Needs final inspection for potable water line setback, gutters, mound system, depth of cover, and final site grading. Final inspection completed. Mound system checked, gutters added, depth of cover, alarm/pump checked and final site grading completed Final inspection approved. Emailed copy to building department and contractor. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1554640 EID2141736