Loading...
HomeMy WebLinkAboutAPPROVED, REV KHOV ASPIRE MODEL EDEN MASTER ENGDADE IsRUsS COMPANY, INC. Re : T108-86960: ASPIRE AT Site information: Project Customer K HOVNANIAN HOMES Lot/Block: Site Name: Site Address: 5128 ARMIRA PL St. Zip. FT. PIERCE Dade Truss Company, Inc. 6401 NW 74th Avenue Miami, FL 33166 Tel: (305) 592-8245 Fax: (305) 477-8092 Job Name :ASPIRE AT WATERSTONE Model • EDEN ELV. A AND B General Truss Engineering Criteria & Design Loads (individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2020rrPI2014 Design Program: 8.42 Feb 10 2021 Roof Load: 0.0 psf Floor Load: NIA Wind Code: Wind Speed: 165 mph This package includes 29 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G1 5-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Date Truss ID# seal# i 0910621 CA A0237958 2 0910MI W3 A0237959 3 09106/21 CA A0237960 4 09106121 77 A0237961 5 09106/21 EJ5 A0237962 6 0910621 EJ7 A0237963 7 09/06/21 EJ8 A0237964 8 09mef21 HJ5 A0237885 9 0MV21 HJ7 A0237966 10 OW6121 HJ8 A0237967 11 09/06121 T01 A0237969 12 09/06121 T02 A0237969 13 09)MM T03 A0237970 14 09106121 T04 A0237971 15 0910621 T05 A0237972 1S 0810621 T06 A0237973 17 0910621 77 A0237974 18 09/0621 T08 A0237975 19 0910621 79 A0237976 20 0910621 T098 A0237977 21 0910821 T10 A0237978 22 0910621 T11 A0237979 23 0910621 T12 A0237980 24 091g621 T13 A0237981 25 0910S21 V01 A0237982 26 0910621 V02 A0237983 No. Date Truss 1D#R Seas 27 09J0621 V03 A0237984 28 09/06121 VO4 A0237985 29 09106/21 V05 A0237986 The truss drawing(s) referenced above have been prepared using MiTek Industries, Inc. engineering software under my direct supervision based on the provided by Dade Truss Company, Inc. of Miami, FL. COMPONENTS MANAGEMENT SYSTEMS INC. CERTIFICATE OF AUTHORIZATION # 30680 6401 NW 74 AVENUE MIAMI, FL 33166 305-592-8245 SALVADOR A. JURADO P.E, FLORIDA REGISTRATION # 19939 NOTE: The seal on these drawings indicate acceptance of , professional engineering responsibilty for the truss components shown per ANSI/TPI 1-2014 Section 2. s"O A. ! °.. ;, m rr. ; lF;y d GF near Name "!'.:f;' sus' Date Page 1 oF1 SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6404 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0237958 34295-4-5 CJ 1 Plate Offsets (X,Y)-- [2:0-1-14.0-0-10] JACK TR @ 45 Job Reference (optional) Feb 10 2021 Print: 8.420 s Feb W 2021 MiTek Industries, Inc. Mon Sep 6 14:35:59 2021 Page 1 1131sVIOCZ21 Eg4xvrhYAIX3yhPJt-bgeMbMONIRvFDbOSJYi9Hoyucb4H000MDJL4?VygKvk -1-0-0 1-0-0 1-0-0 1-0-0 Run -8420s 16 2x4 = NOP2X STP= LOADING (psf) SPACING- 2.0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 Vert(LL) -0.00 2 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.01 Vert(CT) -0.00 2 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a nla BCDL 10.0 Code FBC2020/TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No,2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = -8lMechanical 2 = 125/0-8-0 4 = 9/Mechanical Max Horz 2 = 40(LC 12) Max Uplift 3 = .8(LC 1) 2 = .97(LC 12) Max Grav 3 _ 18(LC 12) 2 = 125(LC 1) 4 = 18(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All Forces 250 (lb) or less except when shown. NOTES- (8) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2pst; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=oft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied root live load shown covers rain loading requirements specific to the use of this truss component. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 8 lb uplift at joint 3 and 97 lb uplift at joint 2. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Scale = 1 :6 0 PLATES GRIP MT20 2441190 Weight: 5 lb FT = 20% LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply 34295-4-5 CJ3 JACK TR @ 45 16 1 A0237959 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:01 2021 Page 1 ID3s6710CZ21 Eg4xvrhYAIX3yhPJt-XCm642Reg2AzSvXrOzldMD1 D0P9,fsl_fgdg840ygKvi -1-0-0 3-0-0 1-0-0 3-0-0 2x4 NOP2X STP; Plate Offsets (X,Y)-- [2:0-1-14,0-0-10) LOADING ?psf) SPACING- 2-0-0 CSI. DEFL. in (too) 1/defl Ltd TCLL 20.0 Plate Grip DOL 1.25 TC 0.14 Vert(LL) 0.01 2-4 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.14 Vert(CT) -0.01 2-4 >999 180 BCLL 00 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a Na BCDL 10.0 Code FBC2020;'l P12014 Matrix-P LUMBER - TOP CHORD 2x4 SP N0.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10 0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 52/Mechanical 2 = 187;'0-8-0 4 = 26/Mechanical Max Horz 2 = 71(LC 12) Max Uplift 3 = -32(LC 12) 2 = -142(LC 12) 4 = 28(LC 8) Max Grav 3 = 54(LC 17) 2 = 187(LC 1 4 = 52(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 rib) or less except when shown. NOTES ;8) 1) Wind: ASCE 7-16; Vult=165mph �3-second LOAD CASE(S) gust) Vasd=128mph; TCDL=4.2psf; Standard BCDL=3.Opsf; h=15tt; B--45ft; L 28ft: eave=4ft: Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS .'directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 Interior(1) 2-0-0 to 2-11-4 zone; porch left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL 1 60 2) Building Designer Project engineer responsible for verifying applied roof live load shown covers rain loading requ.rements specific to the use of this truss component. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a 1 ive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide will fit between the bottom chord and any other members 61 Rotor to girder; s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 32 lb uplift at joint 3, 14? lb up ift at joint 2 and 28 lb uplift at joint 4. 8) "This manufactured product is designed as an indiv!dual build.ng component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." PLATES MT20 Scale = 1,9 9 GRIP 244.190 Weight: 11lb FT 20% SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Qty Ply A0237960 34295-4-5 CJ5 -1-0-0 1-0-0 Plate Offsets (X,Y) - (2-.0-1-14,0-0-10) JACK TR @ 45 Job Reference (optional) Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:02 2021 Page 1 ID:ts6710CZ21 Eg4xyrhYAlX3yhPJt-?PKVDNSGbMlp4361_gHsvQaJFpGVblEpvHZkogygKvh 5-0-0 5-0-0 Run- 8.420 s NOM STP= 12 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud TCL'- 20.0 Plate Grip DOL 1.25 TC 0.45 Vert(LL) 0,10 2-4 >575 240 TCDL 7.0 Lumber DOL 1,25 BC 0.49 Vert(CT) 0.09 2-4 >628 180 BCLL 0.0 ' Rep Stress incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 GOT CHORD 2x4 Si' No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid cei,ing directly applied or 10-0-0 oc bracing MiTek recommends that Stabi'izers and required crass bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 114.Mechan;cal 2 = 25310-8 0 4 _ 46/Mechanical Max Horz 2 = 103(t C 12) Max Uplift 3 = -77(LC 12) 2 = -180(LC 12) 4 = 50{1-C 8) Max Grav 3 = 114(LC 17) 2 = 253(LC 1) 4 = 92(LC 3) FORCES. ', lb; Max. Comp.'Max. Ten. - All forces 250 (lb) or less except when shown. NOTES (8) 1) Wind: ASCE 7-16; Vult=165mph (3-second LOAD CASE(S) Standard gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=1511t; B=45ft; L=28ft; eave=4ft; Cat. Il; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 Interior(1) 2-0-0 to 4-11.4 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 77 lb uplift at joint 3, 180 lb uplift at joint 2 and 50 lb uplift at joint 4. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Scale = 1:13.7 PLATES GRIP MT20 244/190 Weight: 17 lb FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA REG NO,. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss 34295-4-5 ICJ7 I r'# 1-0-0 Truss Type Qty Ply A0237961 JACK TR @ 45 2 1 Job Reference (optional) Run. 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:03 2021 Page 1 ID-U6710CZ21 Eg4xvrhYAlX3yhPJ1-TbutRtTuLtOghOhDYNo6Se7RVDcrKoUy6xJIBGygKvg 7-0-0 I 7-0-0 3x4 tit NOP2X STP= Plate Offsets (X,Y)-- [2:0-0-13,Edge] LOADING (psf) SPACING- 2 0-0 CS1. DEFL. in (loc) 1/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.67 Vert(LL) 0.10 2.4 >773 240 TCDL 7.0 Lumber DOL 1.25 BC 0.48 Vert(CT) -0.18 2-4 >431 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC20201TP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 159/Mechanical 2 = 324/0-8-0 4 = 78IMechanical Max Harz 2 = 136(LC 12) Max Uplift 3 _ -103(LC 12) 2 -130(LC 12) Max Grav 3 = 159(LC 1) 2 = 324(LC 1) 4 = 121(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8) 1) Wind: ASCE 7-16; Vult=165mph (3-second LOAD CASE(S) gust) Vasd=128mph; TCDL=4.2psf; Standard BCDL=3.Opsf; h=15ft; B=45ft; L=28h; eave=oft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 Intenor(1) 2-0-0 to 6-11-4 zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide will f.t between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss Connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 103 lb uplift at joint 3 and 130 lb uplift at joint 2, 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." PLATES MT20 Scale ■ 1:18.3 GRIP 244.+190 We;ght: 23 Ito FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Qty Ply A0237962 34295-4-5 EJ5 JACK TR 2 1 Job Reference (optional) Run- 8 420 s Feb 10 2021 Pfint, 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14.36:03 2021 Page 1 ID3s671OCZ21 Eg4xvrhYAIX3yhPJt-TbutRITuLfOghDhOYNo6Se7U?DIHKCUyBxJIBGygKvg -1-0-0 _ 5-0-0 1-0-0 5-0-0 2x4 = NOP2X STP= Plate Offsets (X,Y)-- [2:0-1-14,0-0-10] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.45 Vert(LL) -0.03 2-4 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0,26 Vert(CT) -0.05 2-4 >999 180 BCLL 0,0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 114/Mechanical 2 = 253/0-8-0 4 = 46/Mechanical Max Horz 2 = 103(LC 12) Max Uplift 3 = -77(LC 12) 2 = -116(LC 12) Max Grav 3 = 114(LC 17) 2 = 253(LC 1) 4 = 92(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown, NOTES- (8) 1) Wind: ASCE 7-16; Vult=165mph (3-second LOAD CASE(S) gust) Vasd=128mph; TCDL=4.2psf; Standard BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; save=oft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interior(1) 2-0-0 to 4-11-4 zone;C-C for members and forces & MWFRS for reactions shown; lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 77 lb uplift at joint 3 and 116 Ito uplift at joint 2. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Scale = 1:13.7 PLATES GRIP MT20 2441190 Weight: 17lb FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type oty Ply 34295-4-5 EJ7 JACK TR 33 A0237963 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8 420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:05 2021 Page 1 ID:Is67l0CZ21 Eg4xvrhYAlx3yhPJ1- P_?dsPU8IGgOxWrclogaX3Cq-c Dlo 4DFbFoOD9ygKve -1-0-0 3-6-0 7-0-0 1-0-0 3-6-0 3-6-0 44 = 8 NOP2X STP= 3x4 — Plate Offsets (X,Y)-- [2:0-1-14,Edge] LOADING (psf) SPACING- 2.0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.48 Vert(LL) 0.23 2-5 >348 240 TCDL 7.0 Lumber DOL 1.25 BC 0.74 Vert(CT) 0.21 2-5 >383 180 BCLL 0.0 ' Rep Stress Incr YES W B 0.18 Horz(CT) -0.00 5 n/a n/a BCDL 10.0 Code FBC2020frP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-11-14 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 781Mechanical 2 = 325/0-8-0 5 = 1591Mechanical Max Horz 2 - 136(LC 12) Max Uplift 4 = -52(LC 12) 2 = -223(LC 12) 5 = -137(LC 12) Max Grav 4 - 81(LC 17) 2 = 325(LC 1) 5 = 165(LC 3) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-316/356, 6-7=-285/360, 3-7=-262/365 TOPCHORD 2-6=-316/356, 6-7=-285/360, 3-7=-262/365 BOT CHORD 2-8=-557/275, 8-9=-557/275, 5-9=-557/275 WEBS 3-5=-294/595 NOTES- (8) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3,Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. ll; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interlor(1) 2-0-0 to 6-11-4 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer 1 Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. Scale - 1:18.3 PLATES GRIP MT20 244/190 Weight: 29 lb FT = 200/6 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 52 lb uplift at joint 4, 223 lb uplift at joint 2 and 137 lb uplift at joint 5. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0237964 34295-4-5 EJ8 JACK TR 8 1 Job Reference (optional) Run 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36�06 2021 Page 1 ID:ts67lOCZ21 Eg4xvrhYAIX3yhPJt-uAZ?3lVneaoFYgOoDWLp3Gl2?0h8XV80guXylbygKvd 1-0-0 4-0-0 8-0-0 } 1-0-0 4-0-0 4-0-0 ,, Scale - 1:20.6 3x4 r 20 II 3x4 = 5 NOPPRBOP71-8) 4-0-0 8-0-0 4-0-0 4-0-0 Plate Offsets (X,Y)-- [2:0-1-8,Edge] LOADING (psf) SPACING- 2 0-0 CSI. DEFL. in floc) I'def- L d TCLL 20.0 Plate Grip DOL 1.25 TC 0.27 Vert;LLI 0.04 56 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.25 Vert(CT) 0.04 5-6 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.26 Horz(CT) -0.01 5 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. SOT CHORD Rigid ceiling directly applied or 6-1-5 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 861Mechanical 2 = 361/0-8-0 5 = 188/Mechanical Max Horz 2 -- 152(LC 12) Max Uplift 4 = -59(LC 12) 2 = -245(LC 12) 5 = -160(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-4381679, 7-8=-3631686, 3-8=-354/687 BOT CHORD 2-9=-808/363, 9.10=-808/363, 6-10=-808/363, 5-6=-808/363 WEBS 3-5=-395/878,3-6=-374/181 WEBS 3 5=-395/878, 3-6=-374/181 NOTES- (8) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL_3.Opsf; h=15ft; B=45ft; L=28ft; eave=oft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1.0.0 to 2-0.0 Interior(1) 2-0-0 to 7-11-4 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 59 lb uplift at joint 4, 245 lb uplift at joint 2 and 160 lb uplift at joint 5. PLATES GRIP MT20 244;190 Weight: 35 lb FT = 20% 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type 34295-4-5 ' HJ5 CORNER JACK Oly Ply A0237965 -1-5-0 1-5-0 2 5 4 t� 2x4 t1 0-10-15(0-1-81 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 M Tek ndustries, no, Mon Sep 6 14:36:08 2021 Page 1 Dis67K)CZ21 Eg4xvrhYAIX3yhPJt-gYhmURXt AB2zo-aBKxNH8hglTEJa?ThHCO3gUygKvb 7-0-2 7-0-2 3,5d Fi2 131 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.66 Vert(LL) -0.08 2.4 >974 240 TCDL 7.0 Lumber DOL 1.25 BC 0.51 Vert(CT) -0.17 2-4 >459 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(CT) -0.00 3 n/a Na BCDL 10.0 Code FBC2020ITP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 7-0-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 195/Mechanical 2 = 246/0-10-15 4 = 86/Mechanical Max Horz 2 = 93(LC 8) Max Uplift 3 = .117(LC 8) 2 = -122(LC 8) Max Grav 3 = 195(LC 1) 2 = 246(LC 1) 4 = 134(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45h; L=28ft, eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 117 lb uplift at joint 3 and 122 lb uplift at joint 2. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI i as referenced by the building code." LOAD CASE(S) Standard Scale ■ 1-15.5 5 PLATES GRIP MT20 244-190 Weight: 24 lb FT = 20°�. Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert; 1-5=-54 Trapezoidal Loads (plf) Vert: 5=0(F=27, B=27)-to-3=-95(F= 20, B=-20) , 2=-2(F=9, B=9)-to-4=-35(F=-8, B=-8) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0237966 34295-4-5 HJ7 CORNER JACK 5 1 Job Reference (optional) Run; 8,420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:09 2021 Page 1 I1):ts000Z21 Eg4xvrhYAIX3yhPJt-IIF8hnXfxVAgP89NuevWhvNXkihOksyrWsmcMwygKva -1-5-0 5-2-9 _ 9-7-5 9 10-1 1-5-0 5-2-9-2-9 f 4-4-12 0-2-12 Scale = 1:20.6 2x4 4 5 2x4 = 2x4 3x4 = 5-2-9 5-2-9 9-7-5 9 1 -1 4-4-12 0-2- 2 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 200 Plate Grip DOL 1.25 TC 0.43 Vert(LL) -0.02 7 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.34 Vert(CT) -0.05 6-7 >999 180 BCLL 00 Rep Stress Incr NO WB 0.26 Horz(CT) 0.01 6 n/a n/a BCDL 10.0 Code FBC2020fTP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing direct'y applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance w-.th Stabilizer Installation guide. REACTIONS. (Iblsize) 2 = 370:0-1015 6 _ 583:'Mechanical Max Horz 2 = 165(LC 8) Max Uplift 2 = 145(LC 8) 6 = .247(LC 8) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown TOP CHORD 2-3=-736/123 BOT CHORD 2-7=-246/687, 6-7= 246:687 WEBS 3 6=-733/262, 4-6=-261174 NOTES- (8) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; save=4ft; Cat. ll; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20,Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 145 lb uplift at joint 2 and 247 lb uplift at joint 6, 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8). 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 44 lb FT ■ 20% Standard f) Dead + Roof Live (balanced): Lumber Increase=i.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-8=-54 Trapezoidal Loads (pit) Vert: 8=0(F=27, B=27)-to-5=-133(F= 39r B=-39), 2=-2(F=9, B=9)-to-6=-47(F--14, B=-14) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Qty Ply A0237967 34295-4-5 HJ8 CORNER JACK 1 1 _ Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:10 2021 Page 1 ID1s6710CZ21 Eg4xvrhYAIX3yhPJt-mxpWv7YHiplhlliZSMUE6vfglzHTF9_IWV9uMygKvZ 1 5 0 511 12 11-1-0 11 3 12 1-5-0 5-11-12 5-1-4 0- 2 2x4q"e - 1,22.3 4 5 11 3.54 Fi2 3x4 s 10 I 3 t• 8 1 -- f1 s 12 19 T 14 16 6 30 = 2x# 0.11.5(D-1-8} 6 30 = 5-11-12 5-11-12 11-1-0 1111 3112 5-1-4 0-2-' 2 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I deft Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.60 Vert(LL) -0.05 6-7 >999 240 TCOL 7.0 Lumber DOL 1.25 BC 0.62 Vert(CT) -0.10 6-7 >999 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.52 Horz(CT) 0.02 6 n. a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3'Except* W3: 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-9-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 9-8-5 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer installation guide. REACTIONS. (lb/size) 2 = 520/0-11-5 6 = 720/Mechanical Max Horz 2 = 155(LC 8) Max Uplift 2 = .260(LC 8) 6 = -292(LC 8) FORCES, (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-8=-980/280, 8-9=-953/276, 3-9=-911 /284 BOT CHORD 2-12=-367/908, 12-13=-3671908, 7-13=-367/908, 7-14=-367/908, 14-15=-367/908, 6-15=-367/908 WEBS 3-7=0/346, 3-6=-965/390, WEBS 3-7=01346, 3-6=-9651390, 4-6=-270/190 NOTES- (9) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15h; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tad by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 260 Ito uplift at joint 2 and 292 lb uplift at joint 6. PLATES GRIP MT20 244/190 Weight. 51 lb FT = 20% 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated loads) 78 Ib up at 1-5-12, 78 Ib up at 1-5-12, 44 Ib up at 4-3-11, 44 Ib up at 4-3-11, 38 Ib down and 99 lb up at 7-1-10, 38 lb down and 99 Ito up at 7-1-10, and 86 lb down and 125 Ito up at 9.11-9, and 861b down and 125 lb up at 9-11-9 on top chard, and at 1-5-12, at 1-5-12, at 4-3-11, at 4-3-11, 36lb down at 7-1-10, 36 lb down at 7-1-10, and 67lb down a1 9-11-9, and 67 lb down at 9-11-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F} or back (B). 9) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-5=-54, 2-6=-20 Concentrated Loads (lb) Vert: 8=44(F=22, B=22) 10=-75(F=-38, B. -38) 11i=-173(F=-86, B=-86) 14=-36(F=-18, B=-18) 15=-101(F=-51, B=-51) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply 34295-4-5 T01 HIP GIRDER TR 1 1 A0237968 Job Reference (optional) Run: 8.420 s Feb 10 2021 Pant: 8 420 s Feb 10 2021 Mil ek Industries, Inc. Mon Sep 6 14:36:11 2021 Page 1 I D:Is67.nGZ21 Eg4xvrhYA'X3yhPJt-E7Nu6SZVT6QY1RIm03x-mKSuPRLW Cp97zAFjQpygKvY -1-0-0 5 0 0 7-0-0 _ 12-0-0 1-0-0 5-0-0 # 2.6-0 T 5-0-0 44 4x4 8 4 Scale = 1:21.5 N0132X STP= 2011 3" = NOP2X STP= &- k0-1-8) Al-LW0-1-8) 5-0-0 5-0-0 Plate Offsets (X,Y)-- [3:0-1-12,Edge] 7-0-0 2-0-0 LOADING (psf) SPACING- 2.0.0 CSI. DEFL. in (loc) Ildefl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.36 Vert(LL; -0.03 7 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.49 Vert(CT) -0.07 5-6 >999 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.08 Horz(CT) 0.02 5 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-4-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 9.2-11 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 5 = 773/0-8-0 2 = 85310-8-0 Max Horz 2 = 59(LC 7) Max Uplift 5 = -250(LC 8) 2 = -326(LC 8) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1527/483, 3-8=-1365/482, 4-8=-1365/482, 4-5=-1538/493 BOT CHORD 2-7=-387/1341,6-7=-388/1352, 5-6=-398/1352 NOTES- (11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd= f 28mph; TC D L=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 250 lb uplift at joint 5 and 326 lb uplift at joint 2. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 195 lb down and 66 lb up at 5-0-0, and 195 lb down and 66 lb up at 7-0-0 on top chord, and 86 lb down and 29 lb up at 5-0-0, and 86 lb down and 29 lb up at 7-0.0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12-0-0 _ { 5-0-0 PLATES GRIP MT20 244; 190 Weight: 48 lb FT = 20% 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) "This manufactured product is designed as an individual building Component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-3=-54, 3-4=-1 11 (F=-57), 4-5=-54, 2-7=-20, 6-7=-43(F=-23), 5-6=-20 Concentrated Loads (lb) Vert: 3=-195(F) 4=-195(F) 7=-86(F) 6=-86(F) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0237969 34295-4-5 T02 COMMON TR 7 1 Job Reference (optional) Run; 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc- Mon Sep 6 14:36:12 2021 Page 1 DISVIOCZ21 Eg4xvrhYAIX3yhP,h-iKwHKoaXEQYPGbtyZm5D,1X?2PngxG7HCq-,GzFygKvX i -1-0-0 6-0-0 12-0-0 1-0-0 6-0-0 6-0-0 Scale . 1.21.1 4x4 NOP2X STP= 2x4 NOP2X STP= APYO.1.81 12-0-0 _ _6-0-0 6-0-0 _ 6-0-0 y Plate Offsets (X,Y)-- [2:0-1-8,Edge], [4:0-1-8 Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I+dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.41 Vert(LL) 0.04 4-5 >999 240 MT20 244190 TCDL 7.0 Lumber DOL 1.25 BC 0.36 Vert(CT) -0.07 4-5 >999 180 BCLL 0.0 ' Rep Stress Incr YES W B 0.10 Horz(CT) 0.01 4 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight; 42 .b FT =; 0o% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No-2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 9-8-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 41510-8.0 2 = 496/0-8-0 Max Harz 2 = 69(LC 11) Max Uplift 4 = -133(LC 12) 2 = -209(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-650/420, 6-7=-591 /423, 3-7=-588/434, 3-8=-582/44% 8-9=-588/439, 4-9=-649/438 BOT CHORD 2-5=-317/536, 4-5=-317/536 WEBS 3-5=-22/266 NOTES- (8) 1) Unbalanced roof live loads have been LOAD CASE(S) considered for this design. Standard 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4111; Cat. II; Exp B; Encl., GCpi=0.i8; MWFRS (directional) and C-C Exterior(2E) -1-0.0 to 2-0-0 , Interior(1) 2-0-0 to 6-0-0, Exlerior(2R) 6-0-0 to 9-0-0, Interior(i) 9-0-0 to 11.8-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 133 lb uplift at joint 4 and 209 lb uplift at joint 2. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0237970 34295-4.5 T03 HIP GIRDER TR 2 1 Job Reference (optional) Run 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries. Inc. Mon Sep 6 14.3&15 2021 Page 1 ID:ts6710CZ21 Eg4xvrhYA X3yhPJt-7vcPygcQXLwz83cXFvOwxAdRv2fYBTCluoDwZaygKvU .1-0.3 7-0-0 14-0-0 21-0-0 28-0-0 35-0-0 36-0-0 1-0-0 7-0-0 7-0-0 7-0-0 7-0-0 7-0-0 1-0-0 Scale: 3r16`=1' 5-00 12 U6 - 18 3x4 = 3x6 = 3x5 = 4x6 = T9 In l 2 W3 _ W# 5v vb 11 2/ BMA c NOP2X STP= 17 g (1p6 81 p �1Q5314g� 13 12 11 10 NOP2X STP= 0-8-WA-1= 8) �O�2X 8% NQP2X STP 3x4 = 2x4 O'8 Q t�8j 3x4 = 3x6 3x6 4x6 = 4x6 = 7-0-0 11-6-3 16-9-4 22-4-0 28-0-0 7-0-0 4-6-3 5-3-1 5-6-12 5-8-0 Plate Offsets (X,Y)-- ]3:0.3-8,0-2-0], [7:0-5-4,0-2-0], [8:0-1-8,Edge], [15:0-3-8,Edge] LOADING (psf) SPACING- 2-0.0 CSI. DEFL, in (loc) Ildefl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.84 Vert(LL) -0.08 11-13 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.68 Verl(CT) -0.14 11-13 >999 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.66 Horz(CT) 0.04 8 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH LUMBER - TOP CHORD 2x4 SP N0.2 *Except` T2,T3: 2x4 SP 225OF 1.9E BOT CHORD 2x4 SP No.2 *Except* B3: 2x6 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-3-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpl 6-15 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2= 80(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 2=-171(LC 8), 16=-143(LC 8), 15=.975(LC 8), 8=-399(LC 8) Max Grav All reactions 250 lb or less at joint(s) except 2=359(LC 17), 16=509(LC 17), 15=3023(LC 18), 8=1068(LC 18) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 3-18=-97/518, 4-18=-97/518, 4-5=-433/1527. 5-6=-433/1527, 6.7=-11591441. 7-8=-2030/653 BOT CHORD 15-16=-625/232, 14-15=-245/869, 13-14=-245/869,12.13=-50611809, 11-12=-50611814,10-11=-504/1795, 8-10=-505/1793 WEBS 3-16=-7861255, 4-15=-13691496, 6-15= 2918/990, 6-113=-1551707, 7-13=-735/228, 7-11=-23/401 NOTES (11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7.16, Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 35-0-0 7-0-0 PLATES GRIP MT20 244/190 T le, Weight: 158lb FT = 20% 7) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 171 lb uplift at joint 2,143 lb uplift at joint 16, 975 lb uplift at joint 15 and 399 lb uplift at joint 8. 9) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 223 lb down and 73 Ito up at 28.0-0 on top chord, and 39 lb down and 13 lb up at 28-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-18=-54, 7-18=-134(F=-80), 7-9=-54, 2-16=-20, 11-16=-59(F=-39), 8-11=-20 Concentrated Loads (lb) Vert:7=-223(F) 11=-39(F) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Qty P'y A0237971 34295-4-5 T04 HIP TR i 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:16 2021 Page 1 ID:ts67lr]C:Z21 Eg4xvrhYAlX3yhPJt-b5An9Ad21f2glDBJocX9TN91XSxgtwot7SyU60ygKvT -0-0 4-9-14 9-0-0 14-8-0 20-4-0 26-0-0 30-2-2 35-0-0 3 -0 0 0 4-9-14 422 5 8 0 5-8-0 5-8-0 4-2-2 4-9-14 -0 Scale: 3116"=1' 4x4 = 5.0D 12 3x4 = 1r. lar. = 4xA = 1. 1s 1 17 NOP2X STP= 19 12 11 NOP2X STP= 0 8 $tom) 3x8 = SX9 = 3M8 = 0-8-1iFA-1=9f 9-0-0 17-6-0 2600 _ 35-0-0 9-0-0 8-6 0 8-6-0 9-0-0 Plate Offsets (X,Y)-- [12,0-3-0,0-3-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Vd PLATES GRIP TCLL 20.0 I Plate Grip DOL 1.25 TC 0.40 Vert(LL) -0.24 12 >999 240 MT20 244.191j TCDL 70 Lumber DOL 1.25 BC 0.94 Vert(CT) -0.47 11-12 >875 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.68 Horz(CT) 0.15 9 n/a Na BCDL 10.0 Code FBC20201TP12014 Matrix-SH Weight: 167lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No-3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-3-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS, (lb/size) 2 = 134210-8-0 9 = 1342/0-8-0 Max Horz 2 = -100(LC 10) Max Uplift 2 = -483(LC 12) 9 = -483(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-14=-2661/1040, 3.14=-2631/1054, 3-4=-24341934, 4-15=-22291905, 15-16=-2229/905, 5-16=-22291905, 5-6=-2866/1127, 6-17=-2229/905, 17-18=-2229/905, 7-18=-2229/905, 7-8=-2434/934,8.19=-263111053, 9-19=-2661/1040 BOT CHORD 2-13=-88912393, 12-13=-969/2806, BOT CHORD 2-13=-889/2393,12-13=-969/2806, 11 -12=-962/2806,9-11=-899/2393 WEBS 4-13=-188/664, 5-13=-783/307, 6-11=-783/307, 7-11=-1881664 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vul1=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(K) A-0-0 to 2-0-0 , Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9 0-0 to 13-2-15, Interior(1) 13.2-15 to 26-0-0, Exterior(2R) 26-0-0 to 30-4-6, Interior(1) 30-4.6 to 36-0-0 zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer 1 Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 9. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type City Ply 34295-4-5 T05 HIP TR 3 1 A0237972 Job Reference {optional; Run: 8.420 s Feb 10 2021 Print; 8,420 s Feb 10 2021 MiTek ndustries, Inc. Mon Sep 6 14:36:17 2021 Page 1 iD-ts6710CZ21 Eg4xvrhYAIX3yhPJt-3Hk9NWeg2yBhNMmvMKZOSbislsL_CTfOM6ileSygKvS 1�0;0 5-9-14 11-0-0 1760 24-0-0 29-2-2 35-0-0 _36.0-0 -" 5-9-14 5-2-2 6-6-0 6-6-0 5-2-2 5 9-14 1--0�b C Y 5.o0 12 1x6 — 20 4x6 = 4 17 ,n 5 ie , a NOP2X STP= 14 i$ 12 11 14 NOP2X STP= 0.84M-1=9) 2x4 3xa — Wr9 = 3x4 2x4 0-6-0 t--9) 5-9-14 11-0-0 1 17-6-0 24-0-0 29=2-2 35-0-0 5-9-14 5-2-2 6 6-0 6 6 0 5-2-2 5-9-14 Plate Offsets (X,Y)--[4:0-3-8,0-2-0], [6:0-3-8,0-2-0], [12:0-4-0,0 3-0] LOADING (psf) SPACING- 2-0-0 CSI, DEFL. in (loc; I:defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.52 Vert(ILL) -0.20 12 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.68 Vert(CT) -0.38 11-12 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.28 Horz(CT) 0.13 8 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 175lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-2-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 6.3-10 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 - 134210.8-0 8 = 1342/0-8-0 Max Horz 2 = -120(LC 10) Max Uplift 2 = -483(LC 12) 8 = -483(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-15=-2711/1016, 3-15=-2655/1029, 3-16=-2266/890, 4-16=-2209/905, 4-17=-2408/1011,17-18=-2408/1011. 5-18=-2408/1011, 5-1 9=-2408/1 011, 19-20=-2408/1011, 6-20=-2408/1011, 6-21=-2209/905, 7-21=-2266/890, 7-22=-2655/1029, 8-22=-2711/1016 BOT CHORD 2-14=-861 /2423, 13.14=.861 /2423, BOT CHORD 2-14=-861/2423, 13-14=-861/2423, 12-13=-65412041,11-12=-664/2041, 10-11=-872/2423, 8-10=-872/2423 WEBS 3-13=-436/230, 4-13=-66/366, 4-12=-178/571, 5-12=-400/243, 6-12=-178/571, 6.11=-66/366, 7-11=-437/230 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=1511t; B=45ft; L=28ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2.0-0 , Interior(1) 2-0-0 to 11.0-6, Exterior(2R) 11-0-6 to 15-3-4, Interior(1) 15-3-4 to 23-11-10, Exterior(2R) 23-11-10 to 28-2-9, Interior(1) 28-2-9 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 8. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oily P y 34295-4-5 IT06 A0237973 HIP TR 3 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, 'nc. Mon Sep 6 14:36:18 2021 Page 1 ID:1s6710CZ21 Eg4xvrhYAIX3yhP R-XUIYaseipGJY?WL6w1 ZdYcE1 aGcyt-re9bmRaAvygKvR -1-OP.. 6-9-14 13-0-0 , -17-6-0 _ 22-0-0 28-2-2 35-0-0 36-0.0 1-0-0 6-9-14 6-2-2 4-6-0 4-6-0 6-2-2 6 9-14 1-0-0 Scale: 3.16"- ' Ax4 = 9x4 4 to K a iB NOP2X STP= 14 18 c i le LL 11 +0 NOP2X STP= 0.8-QMIA2) 2xa 1 3x8 = 4x6 = 3x8 = 2xA 0-8-%MU2) 6-9-14 13-0-0 22-0-0 28-2-2 35-0-0 6-9-14 6-2-2 9-0-0 6-2-2 6-9-14 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (toe) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.55 Vert(LL) -0.34 11-13 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -0.59 11-13 >693 180 BCLL 0.0 Rep Stress Incr YES WB 0,61 Horz(CT) 0.14 8 n/a n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-SH Weight: 173 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-10-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Iblsize) 2 = 1342/0-8.0 8 = 1342JO-8-0 Max Horz 2 = -140(LC 10) Max Uplift 2 = -483(LC 12) 8 -483(LC 12) Max Grav 2 = 1490(LC 17) 8 = 1490(LC 18) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-15=-2974/1009, 3-15=-2924/1025, 3-16=-2317/838, 4-16=-2258/856, 4-17=-2109/840, 5-17=-2108/840, 5-18=-2108/840, 6-18=-2109/840, 6-19=-2258/856, 7-19=-2317/839, 7-20=-2925/1025, 8-20=-2974/1009 TOP CHORD 2-15=-2974/1009, 3-15=-2924/1025, 3-16=-2317/838, 4.16=-22581856, 4-17=-2109/840, 5-17=-2108/840, 5-18=-2108/840, 6-18=-2109/840, 6-19=-2258/856, 7-19=-2317/839, 7-20=-2925/1025,8-20=-2974/1009 BOT CHORD 2-14=-851/2768, 13-14=-851/2768, 13-21=-65212209, 12-21=-65212209, 12-22=-65212209,11-22=-65212209, 10-11=-861/2663, 8-10=-861/2663 WEBS 3-13=-676/297, 4-13=-1501653, 5-13=-289/111, 5-11=-289/111, 6-11 =-1 50/653, 7-11=-676/297 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph 13-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 13=45ft; L=28ft; eave=oft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interior(1) 2-0-0 to 13-0-0, Exterior(2R) 13-0-0 to 17-6-0, Interior(1) 17-6-0 to 22-0-0. Exterior(2R) 22-0-0 to 26-2-15, Interior(l) 26-2-15 to 36-0-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project eng veer responsible for verifying applied roof We load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) " This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by othersi of truss to bearing plate capable of withstanding 483 Ito uplift at joint 2 and 483 lb uplift at joint 8. 9) "This manufactured product is designed as an individual building component. The suitab lity and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO R.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Jab I Truss Truss Type Oty Ply 34295-4-5 1 T07 HIP TR 3 1 A0237974 A - -/- 7-9-14 ♦- 7-9-14 Job Reference (optional) Run- 8.420 s Feb 10 2021 Print: 8 420 s Feb 10 2021 MiTek Industries, Inc, Mon Sep 6 14:36:19 2021 Page 1 ID3siSTOOZ21 Eg4xvrhYAIX3yhPJt-?grwoCtwaaRPcgvlUk4s50n9gLl4EmJDQB&LygKvQ 15-0-0 20-0-0 27-2-2 35-0-0 36-0-0 7-2-2 5-0 0 7-2-2 7-9-14 1-0-b 4x6 — 4xd _ ,a 17 Scale: 3116"=1' NOP2X STP = i 8 12 1 p $ NOP2X STP = 0.84YA-1=8) 2xd 1 3x4 = 3* = 3x8 — 2s4 II 0-87M-10) 7-9-14 15-0-0 20-0-0 27-2-2 7-9-14 7-2-2 5-0-0 7-2-2 Plate Offsets (X,Y)-- [4:0-3-8,0-2-0],[5:0-2-0,0-2-4] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(LL) -0.17 10-12 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.34 12-13 >999 180 BCLL 0.0 ' Rep Stress ncr YES WB 0.88 Horz(CT) 0.13 7 n/a n/a BCDL 10.0 Code FBC2020TTP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No-2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing d'rectly applied or 2-6-5 oc pur.ins. BOT CHORD Rigid ceiling d,rectly applied or 6-3-7 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Insta:Iation guide. REACTIONS. (lb/sizei 2 = 134210-8-0 7 = 1342/080 Max Horz 2 160(LC 11) Max Uplift 2 = -483(LC 12) 7 -483(LC 12) FORCES. (b) Max Comp 'Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-14=-26551989, 3.14--2584f1008, 3 15= 19381799, 4.15=-18531813, 4-16 17131803, 16-17.-17131803, 5-17=-17131803, 5-18-1850813, 6 18= 19391799, 6-19=-258311008, 7-19=-26551989 SOT CHORD 2 13= 82812365, 12.13=.82812365, BOT CHORD 2-13=-828/2365,12-13=-828/2365, 11-12=-514/1712,10-11=-514/1712, 9-10=-839/2365, 7-9=-839/2365 WEBS 3-13=0/326, 3-12=-728/346, 4-12=-107/446, 5-10=-114/446, 6-10=-728/346, 6-9=0/326 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design, 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 8=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1.0.0 to 2-0-0 , Interior(1) 2-0-0 to 15-0-6, Exterior(2R) 15-0-6 to 19-3-4, Interior(1) 19-3-4 to 19-11-10, Exterior(2R) 19.11-10 to 24-2-9, Interior(1) 24-2-9 to 36-0-0 zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 35-0-0 1 7-9-14 PLATES GRIP MT20 244/190 Weight: 172 lb FT = 20% 7) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 7. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0237975 34295-4-5 T08 HIP TR 3 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:19 2021 Page 1 I D:ts67K)CZ2 i Eg4xvrhYAIX3yhPJ1-?grwoClwaaRPcgv[Uk4s50nE0ty24lfJPOB8iLygKvO 18-0-0 1 -3 12-3.13 17-0-0 17-5 0 22 8-3 28-10-13 _35-0 006-0� -0 frt� 8-2-14 4-8-3 0-6'0 4 8 3 6-2-10 f 6-1--3 46 0-6-0 Scale = 1:65.1 _ 5.00 12 4x$ NOP2X STP= "' 13 ' NOP2X STP= 0-EbQt1+9) 3x4 = 5x$ — 3x# = 0-e1Q%9-t-9) 18-o-0 8.9-14 1700 1.7-6-0 26-2-2 + 8.9-14 8 2 2 17610 8-2-2 0-6-0 Plate Offsets (X,Y)-- [13:0-4-0 0-3-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.42 Vert(ILL) -0.17 13 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -0.38 12-13 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.63 Horz(CT) 0.12 10 n.a nra BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-2-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 6.5-4 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1342/0.8-0 10 = 134210-8-0 Max Horz 2 = -185(LC 10) Max Uplift 2 = -483(LC 12) 10 = -483(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-15=-2662/973, 3-15=-2623/987, 3-4=-2429/906,4-5=-2345/916, 5-16= 1693/710, 6-16=-1632/725, 6-17=-1632/725, 7-17=-1693810, 7-8=-2345/916, 8-9=-2429/906, 9-18=-2623/987, 10-18=-2662/973 BOT CHORD 2-14=-821/2394, 13-14=-599/1929, BOT CHORD 2-14=-821/2394, 13-14=-599.1929. 12-13=-609/1929, 10-12=-831/2394 WEBS 3-14--297/214, 5-14=-1101491, 5-13= 608/323, 7-13=-608/323, 7-12=-110/491,9-12-297/214, 6-13=-389/1014 NOTES- (8; 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B 45ft; L 28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 Interior(1) 2-0-0 to 17-6-0, Exterior(2R) 17-6-0 to 21-8.15, Intericr(1) 21-8-15 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer , Protect engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord ive load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other 35-0-0___ i 8-9-14 PLATES GRIP MT20 2441190 Weight: 172 lb FT = 20% 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 10. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO ME STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0237976 34295-4-5 T09 COMMON TR 29 1 Jab Reference (optional) Run: 8.420 s Feb 10 2021 Pint. 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:21 2021 Page 1 ID:ts671OCZ2tEg4x,r(hYAIX3yhPJt-x3zgCthB6Bh7s 3hb96KARsa2TfdYArcHkgFn0ygKv0 0 _ 5-10-0 , 11-8-0 + 17-6-0 23-4-0 _ 29-2-0 35-0-0 36-0-0 0 5.10-0 5-10-0 5-10-0 5-10-0 5-10-0 5-10-0 1-0-0 5.00 P2 4x4 6 T. 3x6 3x4 21x 5 4 °h 2x4 . Cd 3 Yy4 2 1�>f 1 \ NOP2X STP 14 19 0-830004-9) 3x4 ._ Sx8 Scale - 1 52.3 17 -T 3x4 7 3x6 8 3 9 t T1 \ 1s �VJ1 y}�- 10 11 12 NOP2X STP 3x4 - 0-mo)-A-9) 8-9-0 17-6-0 26-3-0 _ 35-0-0 8-9-0 8-9 0 8 9-0 8-9-0 Plate Offsets (X,Y)-- [13:0-4-0,0-3-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (too) l,defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC OA1 VerI1LL) -0.17 13 >999 240 MT20 244.;190 TCDL TO Lumber DOL 1.25 BC 0,89 Vert(CT) -0.38 13-14 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.71 Horz(CT) 0.12 10 n/a n/a BCDL 10.0 Code FBC20201TP12014 Matrix-SH Weight: 171 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No 2 BOT CHORD 2x4 SP No 2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-2-9 oc purlins. BOTCHORD Rigid ceiling directly applied or 6-4-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 134210-8-0 10 = 134210-8-0 Max Horz 2 _ 185(LC 11) Max Uplift 2 =-483(LC 12) 10 =-483(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-15=-2664/988, 3-15=-2626/1002, 3 4= 2433/918, 4-5=-2322/928, 5-16=-1702/734, 6.16=-1637/743, 6-17=:-1637/743, 7-17=-1702/734, 7 8= 2322/928, 8-9=-2433/918, 9-18=-2626/1002,10-18=-26641988 BOT CHORD 2-14= 84012396, 13-14=-64411985, BOT CHORD 2-14=-84012396, 13-14=-64411985, 12-13=-649/1985, 10-12=-84512396 WEBS 6-13=-3561972, 7-13=-634/329, 7-12=-82/464, 9-12=-273/196, 5-13=-634/329, 5-14=-82/464, 3-14=-273/196 NOTES (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gusty Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 13=451t; L=28ft; save=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interior(1) 2-0.0 to 17.6.0, Exterior(2R) 17-6.0 to 20.6-0, Interior(1) 20-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer 1 Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom Chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2.0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 10. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job 34295-4-5 Truss Truss Type T09B GIRDER TR Qty Ply A0237977 Job Reference (optional) Run: 8.420 :z Feb 10 2021 Print. 8-420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14!36:23 2021 Page 1 ID is6710CZ21Eg4xvrhYAlx3yhPJt-uR5RdZiReoxr51D3ja9oFsyvJH0H05ivk29Ls6ygKvM 18-4-0 1 0 8.1.0 11.8� 12-f 1 16 8 0 1 -6 0 22-1-10 23.4-9 26-11 0 35-D-0 35-0-0 14Z 8 1.0 3.7fi 3.4 3-8-12 0-10-0 3-9-10 1-2-6 3-7-0 8-1.0 ] -0-6 0-10-0 Scale - 1:66.5 1 2 0-8.0(@Xt4 ]-P 3x6 �T 5x8 --- 5.00 12 ST134 7 T-L.- 28 27 37 AMRA* 8x10 4x4 0 9 13 4x4 4x8 y tinwf 11 _ 26 25 94"W5tp 3x8 4x4 = 35 30 11 16 3x6 k 18 5x8 � a 19 20 36 10 II T 2 24 23 8x10 = o� m 0 21 22 i NOP2X STP o 0-IQO�--J -14) 18-4-0 26-11.0 89- 411-8-0 1 -11 16-8-0 1 =6.0 22-1-10 23-4-025-11-2 _35-0-00 — -1-0 8-1-0 D-B- 42-10-2 -3• 3.5.12 I 0=10-0 3-9-14 1-2A 2-7-20-11-14 8-1-0 0.1 TO Plate Offsets (X,Y)-- [2:0-3-12,Edge], [3:0.4.0,0.3-4), [7:0-2-0,0-0-13], [10-0-2-0.0-1-12], [12:0-1-12,0-2-0], [16:0-2-0,0-0-6], [20.0-4-0,0-3-4], [21:0-3-12 Edge], [24:0-4-8,0-4-8], [25:0-1-12,0-2-0], [26:0.4-12,0-1-8], [27:0-4.8,0-4-8], [29:0-1-14,0-1-0] LOADING (pst) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.49 Vert(LL) 0.11 23 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.69 Vert(CT) 0.14 21.23 >999 180 BCLL 0.0 ' Rep Stress Incr NO W B 0.69 Horz(CT) 0.02 21 n/a Na BCDL 10.0 Code FBC2020/TP12014 Matrix SH Weight: 280 lb FT = 20% LUMBER - TOP CHORD 2x4 SP N0.2 "Except' T2,T4: 2x6 SP No.2 T1: 2x4 SP 225OF 1 9E BOT CHORD 2x6 SP NO-2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-0-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-5-4 oc bracing. JOINTS 1 Brace at Jt(s): 11, 15, 33, 14, 5 MiTek recommends that Stablizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2= i85(LC 11) Max Uplift All uplift 100 lb or less at joint(s) except 2=-711(LC 33), 21=-1173(LC 34), 27=-839(LC 33), 26=-1483(LC 34) Max Grav All reactions 250 lb or less at joint(s) except 2 675(LC 30), 21=1447(LC 31), 27=1090(LC 30), 27=770(LC 1), 26=3145(LC 1) FORCES. (lb) MAMW%t fin. - All forces 250 (lb) or less TOP CHORD 2-3=-1600/1634, 3-4=-1063/1213, 4-6=-767/940, 6-7=-743/913, 7-34=-7131861, 9-34=-447I628, 9-13=-367/616, 13.35=-4471602, 16-35=-643/802, 16-18=-723/725, 18-19=-7571776, 19-20=-1058/1047, 20-36= 2515/2048, 21-36— 3538/2980,3-5=-575/698, 5-38=-571/695, 8-38=-571/695, 8-10= 571/695, 110-11 =-4541394, 11-12=-141288,12-14=-1256/737, 14-15=-1256/737, 15-17=-12951756, 17-20,-1296/757 BOT CHORD 2-28=- 1672/1542, 27-28=-899/755, 27-37=-1201/10751 26-37=-118411041,25-26=-734/575, 24 25=-513/519, 23-24=-182112366, 21-23= 264613126 WEBS 9-11= 640/319, 3-28=-32/310, 20-23=-295/703, 3-27=-761 /470, 10-27=-720/727, 12-24= 907/1805, 20-24=-990/536, 7-11=-219/267, 11-33=-895/578,16-33=-862/558, 15-16=-290/468, 10-26=-2691/1781I 12-25=-1473/813, 10-25=-840/1671 NOTES- (16) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; Gable Roof; Common Truss; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0.0, Interior(1) 2-0-0 to 17-6-0, Exterior(2R) 17-6-0 to 20-6.0, Interior(l) 20-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qual,fied building designer as per ANSI/TPI 1. 4) Building Designer 1 Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated, 7) All plates are 2x4 MT20 unless otherwise indicated. 8) Gable studs spaced at 2.0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other I ive loads 10'; ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 w,de will fit between the bottom chord and any other members. SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply 34295-4-5 T09B GIRDER TR 1 1 A0237977 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:23 2021 Page 2 ID:1s6710CZ21 Eg4xvrhYAIX3yhPJt-uR5RdZiReoxr51D3ja9oFsyvJHOH05ivk29Ls6ygKvM NOTES. (16) 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 711 lb uplift at joint 2, 1173 lb uplift at joint 21, 839 lb uplift at joint 27 and 1483 lb uplift at joint 26. 12) This truss has been designed for a total drag load of 100 pit. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 35-0-0 for 100.0 plf. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 14) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 294 lb down and 167 lb up at 27-0-0 on top chord, and 472 lb down and 268 lb up at 27-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 15) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 16) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-3=-54, 3-9=-54, 9.20=-54, 20-22 -54. 2-37=-20, 23-37a-65(F=-45), 21-23=-20, 20-38=-93(F) Concentrated Loads (lb) Vert: 23=-472(F) 36=-294(F) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss 34295-4-5 T10 HIP TR Job Reference A02379781 Run 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:24 2021 ID:ts67K)CZ21 Eg4xvrhYAIX3yhPJt-Mdfprvi3P63ijRoFGlg 1 o3U3Ngk7lVC2ziu, T0.0 4-9-14 9-0-0 I 14-8-0 , 20-4-0 , 26-0-0 i_ 30-2-2 T 35-0-0 3 - 0 0-6 4-9-14 4-2-2 5-8-0 5-8-0 5-8-0 4-2-2 4-9-14 -0-0 4x4 5.00 F1 2 3x5 — 10 iof. 3x5 — 4x4 — 2t Scale =. 1-.62.3 v 3x8 = 15 14 13 12 11 NOP2X STP = (0-2-5) (OS�Bj(0-1.8) 3xti _ 5x8 — 0.8-QM1�2) NOP2X STP — 5x8 3x6 17-6-0 8-6-0 -44,0-2-01,.(5:0-2-4,0-1-81, LOADING (psf) I SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr NO BCDL 10.0 Code FBC2020/TPI2014 LUMBER - TOP CHORD 2x4 SP 2250F 1.9E 'Except" T2: 2x4 SP No.2 BOT CHORD 2x4 SP 225OF 1.9E 'Except' B2: 2x4 SP N0.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3.7-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-1-9 oc bracing. WEBS 1 Row at midpt 5.16 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 10-0-0 except (jt=length) 9=0-8-0, 15=0-8-0. (lb) - Max Horz 2= 100(LC 31) Max Uplift All uplift 100 lb or less at joint(s) 15 except 2=-1215(LC 31), 16=-974(LC 33), 9=-1852(LC 34) Max Grav All reactions 250 lb or less at joint(s) 15 except 2=1177(LC 30), 16=1752(LC 1), 9=1990(LC 31) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-17=-3056/3235,3.17=-2206/2778, CSI. DEFL. in (loc) TC 0.53 Vert(LL) 0.14111-13 13C 0.59 Vert(CT) -0.21 9-11 W B 0.86 Horz(CT) 0.03 9 Matrix-SH TOPCHORD 2-17=-305613235,3-17=-220612778, 3-4=-l99212296, 4-18=-720/1050, 18-19=-1029/1359, 5-19=-1196/1525, 5-6=-1717/1458, 6-20=-1186/637, 20-21=-1186011, 7-21=-2167/1771, 7-8=-3492/2912, 8-22=-4252/3478, 9-22=-4620/4219 BOT CHORD 2-16=-3057/2863,15-16=-131511499, 14-15=-101811202, 13-14=-879/1062, 12-13=-655/1672, 11-12=-2372/2795, 9-11=-375914292 WEBS 3-16=-3841304, 4-16=-588/461, 5-16=-2079/1597, 5-13=-90411225, 6-13=-1035/962, 6-11=-991/1115, 7-1 t=-5331719, 8-11=-347/320 NOTES- (10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 13=45h; L=28ft; eave=oft; Cat. ll; Exp 8; Encl., GCpi=O.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2.0-0 , Inlerior(l) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 13-2-15, Interior(1) 13-2-15 to 26-0-0, Exterior(2R) 26-0-0 to 30-4-6, Interior(1) 30-4-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 Ildefl L/d PLATES GRIP >999 240 MT20 2441190 >999 180 nla n/a Weight: 167 lb FT = 20% 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15 except at=lb) 2=12115, 16=974, 9=1852. 9) This truss has been designed for a total drag load of 250 plf. Lumber DOl_=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0.0-0 to 35-0.0 for 250.0 plf. 10) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Qty Ply 34295-4-5 T11 HIP GIRDER TR 2 A0237979 Job Reference (optional) Run- 8.420 s Feb 10 2021 Pr'nt: 6 420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14.36-26 2021 Page 1 ID:Is6710CZ21Eg4xvrhYAIX3yhPJt OnZGbIJxIJPylyeOliVtUaKOUMhDPSLOON?SRygKvJ +0-0 3-8-11 7-0-0 1040 , 1392 21 2 14 28-0-0 35-0-0 36-010 1-0-0 3-8-11 3-3-5 3-4-0 3-5-2 7-5-11 6-9-2 7-0-0 1-0 5x6 2x4 I 5.00 12 5x10 — 4 5 6 3x4 Scale: 3146"-1 4x6 = 3x4 — 5x6 = 7 e 9 NOP2X STP= 20 19 18 17 1d 15 14 13 12 NOP2X STP= 4 8 �frQ L81 Aft —§ 0.8-W1:8) 4x6 = 4x6 = 9xE = 3x4 = 4x6 = 5x8 = 5x8 SA W B = 7-0-0 10-4-0 19-1-8 28-0-0 29-5 35.0-0 7-0-0 3-4-0 8-9-8 8-10-8 1-5- 5-7-0 Plate Offsets (X,Y)-- [2:0.1-8,Edge], [6:0-5.0,0.2-12], [10:0-4-2,0 1-81, [12:0.3-12,0-2.8), [15:0-1-12,0-1.8], [17:0.2-0,0-3-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Ifdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.89 Vert(LL) -0.23 13-15 >999 240 MT20 244?190 TCDL 7.0 Lumber DOL 1.25 BC 0.84 Vert(CT) -0.48 13-15 >612 180 SCLL 0.0 ' Rep Stress Incr NO WB 0.68 Horz(CT) 0.05 10 n/a n/a BCDL 10.0 Code FBC2020r7P12014 Matrix-SH Weight: 184 lb FT = 20% LUMBER - TOP CHORD 2x4 SP 2254F 1.9E 'Except' T273: 2x6 SP No.2 BOT CHORD 2x4 SP 2251Y 1.9E 'Except" B3,131: 2x4 SP No.2 132: 2x6 SP No.2 WEBS 2x4 SP No.3 *Except' W6: 2x4 SP No.2 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-3-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-4-7 oc bracing. WEBS 1 Row at midpt 6-17 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Iblsize} 10 = 1800l0-8-0 17 = 471008.0 2 -167r0-8-0 Max Horz 2 = -79(LC 6) Max Uplift 10 = -636(LC 8) 17 = -1528(LC 8) 2 -382(LC 18) Max Grav 10 = 1807(LC 18) 17 4710(LC 1) 2 72(LC 5) Continued on page 2 Max Grav 10 = 1807(LC 18) 17 = 4710(LC 1) 2 = 72(LC 5) FORCES. (lb) Max. CompdMax, Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-255/1101, 3-4=-36811267, 4-5=-872/2846, 5-6=-87212845, 6-7=-28871956, 7-8=-28871956, 8-9=-3515/1184, 9-10=-395211255 BOT CHORD 2-20=-972/279,19-20=-966/280, 18-19=-1196/454, 17-18=-1200/454, 14-15=-112513634, 13-14=-112413639, 12-13=-1053/3548, 10-12=-1058/3553 WEBS 4-19=-145/567, 6-17=-361311239, 6-15=-998/3318, 8-15=-12721512, 8-13=-264189, 9-13=-174/823, 5-17=-461/189, 4-17=-2260/734, 3-19=-382/181 NOTES- (11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=oft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 2.0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b) 10=636, 17=1528, 2=382. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 223 lb down and 73 lb up at 7.0-0, and 223 lb down and 73 lb up at 285-0-0, and 223 lb down and 73 Ib up at 28-0-0 on top chord, and 351 Ito down and 115 Ito up at 7-0-0, and 351 lb down and 115 lb up at 28-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). SALVADOR JURADO P.E STATE OF FLORIDA REG NO- 19939 - 6401 NW 74 AVE, MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0237979 34295-4-5 T11 NIP GIRDER TR 2 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:26 2021 Page 2 ID: WAOCZ21 Eg4xvrhYAIX3yhPJ1-IOnZGblJxjJPylye0jiVtUaKOUMhDPSLOON?SRygKvJ DOTES- 01) 11) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-4=-54, 4-9=-134(F=-80), 9-11=-54, 2-19=-20, 13-19=-59(F=-39), 10-13=-20 Concentrated Loads (lb) Vert: 4=-223(F) 9=-223(F) 19=-351(F) 13=-351(F) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0237980 34295-4-5 T12 COMMON TR 1 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8,420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:27 2021 Page 1 INs6710CZ21 Eg4xvrhYAIX3yhPJt-mCKxTxlyi 1 RGavXgyQDka6gfuuEy27Ufg7Z?tygKvl -1-0-0 6-0-0 12-0-0 13-0-0 , 1-0-0 6-0-0 6-0-0 1-0-0 Scale - 1:23.0 4x4 = 5 2x4 11 2x4 11 4 �� 6 5,4012 10 T xx 8 1S {NY� 14 7 3x4 : 1 - 4%1 12 11 10 4x4 _ ?x4 1 �Ix4 2x4 3x4 ._ 6-0-0 12-0-0 6-0-0 6-0-0 Plate Offsets (X,Y)-- [2:0-0-12,0-1-13], [8:0-0-12,0-1-13], (8:0-0-12,0-1-12] LOADING (psf) SPACING- 2-0.0 CSI. DEFL. in (loc) 1/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.15 Vert(LL) 0.00 9 n/r 120 MT20 244-190 T'-DL 712 Lumber DOL 1.25 BC 0.11 Vert(CT) 0.01 9 n/r 120 BCI L 0.0 ' Rep Stress Incr YES WB 0.08 Horz(CT) 0.00 8 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 50lb FT = 20% LUMBER - TOP CHORD 2x4 SIP No.2 BOT CHORD 2x4 SP No-2 W!�BS 2x4 SIP No,3 OTHERS 2x4 SIP No-3 BRACING - TOP CHORD Structural wo.'.d sheathing direct'y applied or 10-0-;. oc puriins. BOT CHORD Rigid telling directly applied or 6-0 0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 12-0-0, (lb) - Max Horz 2= -62(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 8, 11 except 12-10411C 12), 10 104(LC 12% Max Grav All reactions 250 lb or less at joint(s) 2, 8, 11 except 12=283(LC 21), 10=283(LC 22) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 flb; or lesfi except when shown. WEBS 4.12=-197/281, 6-10=-197'281 NOTES- (10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3 second gust) Vasd=128mph; TCDL=4.2psf; BCDL--3.0psf, h=15ft; 8=45ft; L=28ft; eave=2ft; Cat. 11; Exp B; Encl., GCpi=O.18: MWFRS (directional) and C-C Corner(3E1 -1 -0-0 to 2-0-0, Exterior(2N) 2-0-0 to 6-0-0, Corner(3R) 6-0-0 to 9-0-0, Exterior(2N) 9-0-0 to 13 0 0 zone;C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified build ng designer as per ANSI/TPI 1. 4) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 11 except 01=1b) 12=104,10=104. 10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO ME STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oly Ply A0237981 34295-4-5 T13 COMMON TR 2 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 M Tek Industries, Inc. Mon Sep 6 14:36:27 2021 Page 1 IDts671[ ]C.Z21 Eg4xvrhYAIX3yhPJt-mCKxTxlyi1 RGavXgyQDkQi6ctugPy2$Ufg7Z?tygKvl -1-0-0 6-0-0 _ 12-0-0 13-0-0 1-0-0 6-0-0 6-0-0 1-0-0 ' 4x4 = 3 NOP22XgSTP= 2x4 11 NOP2X STP 6-0-0 12-0-0 6-0-0 6-o-a Plate Offsets (X,Y)-- [2:0-1-8,Edge], [4:0-1-8,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) -0.03 2-6 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.36 Vert(CT) -0.06 2-6 >999 180 BCLL 0.0 " Rep Stress lncr YES W B 0.10 Horz(CT) 0.01 4 n/a n/a BCDL 10.0 Code FBC2020/TPl2014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. SOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 49110.8-0 4 - 491 /0-8-0 Max Horz 2 = -70(LC 10) Max Uplift 2 = -205(LC 12) 4 = -205(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-7=-636/407, 7-8=-577/411, 3-8=-573/421,3-9=-573/421, 9-10=-577/411, 4-10=-6361407 BOT CHORD 2-6= 257/523, 4.6=-257/523 WEBS 3-6=-8/264 NOTES (8) 1) Unbalanced roof live loads have been LOAD CASE(S) considered for this design. Standard 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; save=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) -1-0-0 to 2-0-0 , Interior(1) 2-0-0 to 6-0-0, Exterior(2R) 6-0-0 to 9-0-0, Interior(1) 9-0-0 to 13-0-0 zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=205, 4=205. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Scale = 1:22.1 PLATES GRIP MT20 244/190 Weight: 44 lb FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0237982 34295-4-5 Vol VALLEY TR i 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MITek Industries, Inc. Mon Sep 6 14:36:28 2021 Page 1 D1s671OCZ21 Eg4xvrhYAIX3yhPJt-EPuKgGmaTLZ7B361 V7kzyvfsxlE9hVJeuKs6XJygKvH 6-00 6-0-0 +Zt4 .. Scale = 1:14.8 2%4 y 2x4 2x9 LOADING (psf) SPACING- 2.0.0 CSI. DEFL. in (loc) Vdefl Ud TCLL 200 Plate Grip DOL 1.25 TC 0.11 Vert(LL) n/a n/a 999 TCDL 70 Lumber DOL 1.25 BC 0.07 Ver1(CT) n/a n/a 999 BCL L 0.0 ' Rep Stress Incr YES WS 0.09 Horz(CT) 0.00 n/a n/a BCDL 10.0 Code FBC20201TPI2014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No 2 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheath ng directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stab, lizers and required cross bracing be installed during truss erection, !n accordance w th Stabilizer Installat.on guide. REACTIONS. ilblsize) 1 = 5515-11.6 4 845-11-6 5 = 23815 11 6 Max Horz 1 82(LC 12) Max Uplift 4 = -35(LC 12) 5 -100(LC 12) FORCES. (lb) Max. Comp.IMax. Ten. All forces 250 (lb) or less except when shown WEBS 2-5=-177.,295 NOTES (7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 6=45ft; L=28ft; eave=oft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 5-10-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI i as referenced by the building code." LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 21 lb FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply 34295-4-5 V02 VALLEY TR 1 1 A02379$3 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:29 2021 Page 1 ID:IWAOCZ21 Eg4xvrhYAIX3yhPJt-ibSiucnCE:eh_pDgD3rGCV7C?Jhaiozwn6_og3mygKvG 4-0-0 4-0-0 2x4 2x4 (0-1-8) ;0-1-8) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Weft Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) n.:a Na 999 TCDL 7.0 Lumber DOL 1.25 BC 0AI Vert(CT) n::a n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(C7) 0.00 nla n: a BCDL 10.0 Code FBC2020/TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 11513-11-6 3 = 115/3-11-6 Max Horz 1 = 50(LC 12) Max Uplift 1 = -27(LC 12) 3 = -48(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15fh B=45ft; L=28ft; eave=oft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exter!or(2E) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component- 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a! ive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0. 0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard Scale = 1 10.2 PLATES GRIP MT20 244.190 Weight: 13 lb FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Qty Ply A0237984 34295-4-5 V03 VALLEY TR 2 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Pr nt- 8.420 s Feb 10 2021 M Tek -ndustries, Inc. Mon Sep 6 14.36:30 2021 Page 1 IDUVIOCZ21 E_g4xvrhYA X3yhPJt-Bn045yoq?yprRMFPdYnR2KkCt5xTgoAwLdLDhcygKvF 2-0-0 200 4x6 Scale = 1:6 4 5.00 12 2 2x4 1.11.6(0-1-8) Plate Offsets (X,Y)-- [2:0-8-0,0-1-4) 1 11.6(0 1.81 LOADING (pst) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl Vd TCLL 20.0 Plate Grip DOL 1.25 TC 0.02 Vert(LL) nia nfa 999 TCDL 70 Lumber DOL 1.25 BC 0.01 Vert(CT) nla n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 nfa nfa BCDL 10.0 Code FBC2020±TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 20 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structura' wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD R gid ceiling direct y applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be instal ed during truss erect on, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size', 1 = 4111-11-6 3 = 41/1-11-6 Max Horz 1 = 18f.LC 12) Max Uplift 1 = -9(LC 12) 3 = -17(LC 12) FORCES. (lb) Max. Comp./Max. Ten. All forces 250 ('b) or less except when shown. NOTES- (7) 11 Wind: ASCE 7-16; Vult�I65mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL■3.0psf; h-15ft; B=45ft; L=28ft; save=4tt; Cat- It; Exp B; Encl., GCpi=0.18; MW FRS (directionao and C-C Exterior(2E) zone;C C for members and forces 8 MWFRS for reactions shown; Lumber DOL=t-60 plate grip DOL=1.60 2) Building Designer 1 Project engineer responsible for verifying applied roof live load shown covers rain load�ng requirements specific to the use of this truss component. 3) Gab'e requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard PLATES GRIP MT20 2441190 Weight; 5 lb FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA REG NO, 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0237985 34295-4-5 VO4 VALLEY TR 1 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Mon Sep 6 14:36:31 2021 Page 1 IDISVIOCZ21 Eg4xvrhYAIX3yhPJt-t_aSJIoFAGxi2WgcBGlgaYHM4VFUus24aH5m8aygKYE 4-1-0 7-0-0 4-1-0 2-11-0 2x4 ' Scale. 1:16.8 5 4 2x4 2x4 2x4 LOADING (psf) SPACING- 2.0-0 CSI. DEFL. in (loc) I/detl L/d TCLL 20.0 Plate GrpDOL 1.25 TC 0.12 Vert,LLl n1a nia 999 TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(CT) n/a - nla 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.09 Horz(CTl -0.00 4 n/a nra BCDL 10.0 Code FBC2020/TP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.2 `Except' W1: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 99/6-11-6 4 = 7416.11.6 5 = 278/6-11-6 Max Horz 1 = 99(LC 12) Max Uplift 4 = -31(LC 12) 5 = -116(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (1b) or less except when shown. WEBS 2-5=-1951294 NOTES- (7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.opsf; h=15ft; B=45ft; L=28ft; eave=oft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1. Inlerior(1) 3-9-1 to 6-10-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=1b) 5=116. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 26 lb FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA RRG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type City Ply A0237986 34295-4-5 V05 VALLEY TR 1 1 Job Reference +,optlonal:l Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 M Tek ndustfies, nc. Man Sep 6 14:36:32 2121 Page 1 Mls6710CM Eg4xvrhYAIX3yhPJt-7ABgWep4WZ3ZggPakzpv7lgTwvZzwlDpxgKgSygKvD 5-0-0 5-0-0 2x4 2x4 LOADING (pst) SPACING- 2-0-0 CSI. DEFL. in ;loc) rdef L-d TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) n/a n: a 999 TCDL 7.0 Lumber DOL 1.25 BC 020 Vert(CT) n/a n:a 999 BCLL 0.0 ' Rep Stress incr YES WB 0.00 Horz(CT) 0.00 n/a n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing MiTek recommends that Stabilizers and required cross bracing be instal;ed during truss erection, in accordance with Stab liter Insta lation guide. REACTIONS. ('b/size) 1 _ 152/4 11-6 3 = 152/4- t 1-6 Max Horz 1 = 66(LC 12) Max Uplift 1 = -36(LC 12) 3 = -64(LC 12) FORCES. (lb) Max. Comp./Max. Ten - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2pst; BCDL=3.Opsf; h=15111, B=45ft; L=28ft; eave=oft; Cat. II; Exp B; Encl., GCpi=0.18, MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 4-10-4 zone;C C for members and forces & MW FRS for reactions shown; Lumber DOL.1.60 plate gr'p DOL 1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard Scala- 1"01, PLATES GRIP MT20 2441190 Weight: 16 lb FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 . ' Th s sty alert symboluse to attract your A attentlonl PERSONAL SAFETY ISINVOLVEDI When you ese this symbol - BECOME ALERT - HEED ITS MESSAGE. 14ACAUTION: A CAUTION Identifies safe operating practices or Indicates unsafe conditions that could result In personal Injury or damage to structures. HIB-91 Summary Sheet COMMENTARY and RECOMMENDATIONS for HANDLING, INSTALLING & BRACING METAL PLATE CONNECTED WOOD TRUSSES° It Is Me reg2 aslbllltyr of fhe Instapsr lbuNder, bulldlrtt7 contractor, licensed r ffecdon contractor to PMPGFIV race".unload stain handle. inabadland brace metaiolafe connected wood trusses to amtect Na and gMeerbLTheinsteller must exerelse the same high degree of safely awareness as with any other structural material. TPI does not intend these recommendations to beirdetpretedas euperlwtothepro]ectArchitect's or Engineer a design specification for handling, Installing and bracing wood trussesfor a particular roof orfloor. These recornmendatlons are based upon the collective experience of leading technical CAUTION: The builder, building contractor, licensed contractor, erector or erection contractor Is ad- vised to obtain and read the entire booklet "Com- mentary and Recommendations for Handling, In- stalling a Bracing Metal Plate Connected Wood Trusses, HIB-91' from the Truss Plate Institute. DANGER: A DANGER designates a condition Awhere falluretotollowInstructions orhood warn. Ing will moat likely resit to serious personal Injury or death or damage to structures. WARNING: A WARNING describes a condition I A where fallureto follow Instructions could result in TRUSS PLATE INSTITUTE tfe3 D•Ortvkio Dr., Suite 200 Madison, Wisconelri 53719 (e08) 9334900 personnel Inthe wood truss Industry. but mustdueto the nature of responsibilities Invoived, be presented as a guide forthe use of a qualified building designer or Inslaller. Thus, theTruss Plate Inelitute. Inc. expressly diselalms any responsibility fordamages stioing from theuse.*Mcadonorrelance ontherecommendations and Information contained herein by building designers, insulters, and others. Copyright O by Tnma Plata institute. Inc. All rights reserved. This deoument or any part thereof must not be reproduced In any form without written permission of the publisher. Printed in the United Slates of America. UAu tfUN: AfftenlpOrary Draoing should bdno Ives ,than2x4 grade marked lumber. All connections should be made with minimum of 2-1sd nails. All trusses assumed 2' on -center or less. All multi -ply trusses should be connected together In accor- dance with design drawings prior to Installation. TRUSS STORAGE - CAUTION: Trusses should not Abe unloaded on rough terrain or uneven surfaces which could cause damage to the truss. Trusseesstored horlmntally should be sup- ported on blocking to prevent excessive lateral bending and lessen moisture gain. WARNING: Do not break banding until Installa- tion begins or Iift bundled trusses by the bands. [A:: WARNING: Do not use damaged trusses. Trusses stored vertically should be braced to prevent toppling or tipping. DANGER: Do not store bundles upright unless properly braced. ADANDER: Walking on trusses which are lying flat Is extremely dangerous and should bestric ly prohlbited. Frame 1 SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MAIMI FL. 33166 Tay WARNING: Do not attach cables, chains, or WARNING: Do not lift singletrusseswith spans hooks to the web memberc greater than 30' by the peak. MECHANICAL /Omx IINSTAU ATION Approldmately Approximately Tay=- _~ %trues length %lrusa length Line - - Truss spans loss then 3W. Lilting devices should be connected Slrongback/ Spreader Bar to the truss top chord with a closed- Spreaderftr loop attachment utilising materials to• Toe to Toe In such as olings, chains, cables, nylon strapping, etc. of sufficient strength to carry the weight of the truss. I Approximately Approximately Less than or equal to Bo' ` Tag Una Spreader Bar Toe In --\ /—Toe In ApproxlmMly Tag Une At or aborri mid•helgM Less than or equal 10 60' une TLUM Greater than W CAUTION: Temporary bracing shown In this summary sheet Is adequate for the Installation a4 Atrusses with similar configurations. Consult a regisiered professional engineer d a dMerent bracing arrangement Is desired. The engineer may design bracing in accordance with TPI's Rec9ainvended Design SpeaNkmdon for Temporary Bracing of Metal Plate Connected Wood Trusses; DS849, and M some cases determine that a wider spacing Is possible. GROUND BRACING: BUILDING INTERIOR jdROLJNb BRACING: BUILDING EXTERIOR TOP err TO" wAk+N 8004 nl PIwFi.iWar i F e d' > 1@taaw Drlwa woww .uw.... CAUTION: Ground bracing required for all installations. TvP'0d h-W"" W WM"WWM rrld 1P104ftk . a1q r�sii Wan wpdt" M (W Frame 2 SALVADOR .IURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MAIMI FL. 33166 'a' Topetwrdwadwe kftrolyIrraede tw We t*Vmw wwssoeeooeepeeettwnlenodleeo- nNNreWo 01* a broWna4w"wnw.+ lathe uedereldesrtrrteoelordwseaaur{Irmo we aft*" togo Icpwa elvw Imo sherd It 1 4 or Omelet r 7i T' 1 'r �,V TOP Ci Z TOP�AOb b LIRACH itMi mum p, LA U 'ACE � �� $Md- d (09 SPA Cif- SPACIiII � tr'usletis G• i I. 'il l over 3Y - 4! 4 0' 7 Over 4B' ' 60' EE 2 b' Over 60' Sea a re•phlered professional nlylneer OF -- 8PF -- SpPhFir All lateral braces lapped at least 2 trusses. Continuoue Top Chord Literal &ace Required 1W or Greater Attachment Required WARNING: Fellurstotollowthesereoonsmondattonecould result In setters pera mall Injury or damage to uussea or buildings. PITCHED TRuss TOP C(tORD MINIMUM TOP CHORD DIAGONALBRACE Pack LATERAL BRACE spACING (D 12 SPAN DIFFERENCESPACINO(LBS) $ J►trrtss. - - s r— me to 26' 1 Over 28' - 42' 3.0 6' 9 6 Over 2' - W 3.0 S S 3 Over so' See a registered professional engineer OF: Douglas Fir -Larch SP - Southern Pine MirHen►-Fir 8PP- Spruce-PlwFir Continuow Top Chord Lateral Brace All lateral braces Required lapped at least 2 trusses. 10" yr Greater 4 Attachmerrt • y = Required 0. \ tY �r ; _. - _ t_ �•� ��� TprdradatlNsnlstareeybaadesn4rrolN �ti :.. toeaB.reade.w.oaueO.arewrelwdieeo- . �- ` _ 1. �, y� nrer ppaww+aneeueuwaneuw At ry 10OW' n-11 QFNwtoechadwheaow1WA ems Mteehed to eN balls of On toy clad SCISSOR$ TR�lS8 Frame 3 SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. IMAAIMI: FL. 33166 IMs 4 or greater Bottom chord diagonal bracing repeated ` at each end of the building and at same spacing as top chord diagonal bracing. SPAN MINIMUM PITCH BOTTOM CHORD 'LATERAL BRACE SPACING(LBW BOTTOU CHORD DIAGONAL BRACE SPACING (D IaI►trrteaer< Up 10 32' 4112 1 g' 20 15 0V0r 22' - 48' 4 12 13' 10 7 Over 49' - 90' 4 12 I is, s e Over 60' See a f ieiered ratesalonal ea Inner WF - H�enraFlr mr-Larcn SPPF southern PGre SPnwe-Pine-Fir All lateral braces tapped at 1008112 trusses. BOTTOM CHORD PIANE WARNING: Failure to follow thesarecommandatlonscouIdreeultIn E: severe personal injury or damage to trusses or buildings. A Permanent continuous �. lateral bracing as specified by the - truss engineering. WEB MEMBER PLANE Cross bracing repeated at each end of the building and at 20' Intervals. Frame 4 SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 640 74 AVE. MAIMI FL. 33166 SPAN MINIMUM DEPTH TOP CHORD LATERAL BRACE SPACING(LBs) TOP CHORD DIAGONALBRACE SPACING (OBE t#o u"Oes SPIDF iPFJNF U to 32' 3V 8' 18 10 OW 32' - 48, 4r e' 8 Over 48' • i.41r 1 8'1 4 2 Over ow Sae a registered professional vVinser DF - Douglas F1r•Larch SP - Southern Pine HF - Ran%-FIr SPF - Spruce -Pine -Fir d - [2fx412Nx16 PARALLEL ORD TRUSS Topchorda Dwtare lahranr iraead oarr bueMtr teea8taeand oasateollapaa 1f tMan la no dlatia adbradro Diaeonatbraolneahouldbeneow to the who"" of ato lap ehardwbae purlieu m et %W so the sopeld* N the top *herd. Continuous Top Chord LateralBrac Requir e Regarir ed 1tYofareate r Attachment Required roh+r 20yassJ 3W or greater brawk lapod it IrttYVo The end trusser. diagonal brace for cantilevered End diagonals ari iaeemkiior trusses must be stability and must be dupilci&W on placed on vertical both ends of the truss system. rebe In line with the eupporc . AWARNING: Failure to follow the" recommendations could result In Severe Personal Injury or damage to trusses or bulldings. A& 4X2 PARALLEL CHORD TRUSS -TOP CHORD Corttinuoue Top Chord --\ Top cherdaawtareMstrlraerbraoadcan bwkla Lateral &eCe t°put!'aandoauaeoollap'aplbanau"°°ipp Required 1 nalbraeft. DaaranarWWi"altouubana0e0 loth' u,&r"&ee tk-'°peh"rd"I guar"* ur or Greater are eaaohad tvele Iopaldaol lla lop a ItorrR AuachmsM 16 Required is r 300 roSs1 31/a Truss" muethavelurn- bar oriented in the hort- Itlit zornal direction to use breoel! I - wn We brace a oin aPAed � pe g. at least i+rlo � - x. End diagonals sr! f l lisetrrilMl.for stability and must be dupl`:Hl on both ends of the truss system. Frame 5 SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MAIMI FL. 33166 SPAN MINIMUM PITCH TOP CHORD LATERAL BRACE SPACING(LHg) TOP CHORD DIAGONAL BRACE SPACING (DOS) I# truas"I Up to 24' 3/12 S. 1 T 1 12 Over 24' - 42' 3112 7' 10 1 6 Over 42' - 54' S 12 $ DF- Douglas Fir -Larch HF - Hem -Fir ' s a SPSSpruc�s Pins F- PirwFir Diagonal brace also required on end verticals. Tap chordm UW*rn latarity broeod an bu" 4900"W41W a"uwaeaap"Nume lawrrdlaer rwbr&&4 Diago"IbradnyahouldbomM d b IM undarakaot 1tN bD Oherd when purlme era dtadnd 10 dw topNOu of Ow top abord. MONO TRUSS PLUM 12 � gor rWer s• 4 s• ii All lateral braces lapped at least 2 trusses. Continuous Top chord Lateral Brace - Requlred 10' or Greater Attachment Required WARNING: Failure to follow these recommendations could result In severe personal Injury or damage to truaees or buildings. A I I Truss I Depth 1 I Dos) I 1 Lesser of Ir D/60 or 2' IMaxlmunt Plumb Misplacemsm Line INSTALLATION TOLERANCES so �th Lon) 1 4' 1' Lesser of Ll200 or 2- Don} 12" r 38" 3 4" 3' so" 1.1 4" S' 72" 1-1 8' " 1- r Sep f e' 1 o8" r T Lon) Lon) L=0 L(ft) so*11 ' 1 W 3/4- 12.6' Lon) ' Lessor of L/200 or 2" L(In) L1200 L(ft) 20(r' 1- 16.71 2ti(" 1.1 4• 20.8' 300" 14/2" 25.0' OUT -OF -PLUMS INSTALLATION TOLERANCES. OUT -OF -PLANE INSTALLATION TOLERANCES. DANGER:: Under no circumstances should JAWARNING: Do not cut trusses. construction load* of anydeacriptionbepfaced IlAon unbraced trusses. Frame 6 SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MAIMI FL. 33166 PLATES ARE MITEK M20-249,200 MANUFACTURED FROM ASTM A 466 GRD A GALVANIZED STEEL (EXCEPT AS PLATE MUST BE INSTALLED ON EA. FACE OF JOINT SYMMETRICAL (EXCEPT AS SHOWN) DESIGN CONFORMS WI NDS SPECS. FBC2020.THIS DESIGN IS FOR TRUSS FABRICATION ONLY. FOR PERMANENT BRACING (WHICH IS ALWAYS READ.) CONSULT BLDG. ARCHITECT. OVERHANG DETAILS MAXIMUN OVERHANG GRADE OF LUMBE I 2X4 2X6 # 2 SO.PINE 2'-0" 3'-2" S.S. SO -PINE 2'-2" 3'-4" NOTES: OPTIONAL VERTI A) ALL CONNECTORS SPEC. MUST BE INSTALLED PER MFG. SPECIFICATIONS. C) FOR TRUSS DATA,LUMBER,PLATES, ETC. REFER TO INDIVIDUAL ENG. DRAWINGS. D) THIS HAS BEEN DESIGNED FOR THE LOADS GENERATED BY 175 MPH. WINDS AT 26' ABOVE GROUND LEVEL ASCE 7-16 COMPONENTS AND CLADDING AND 7.0 PSF TOP CHORD AND 3.0 PSF B, CHORD DEAD LOAD ARE BEING USED.THE DESIGN ASSUMES OCCUPANCY CATEGORY II, TERRAIN EXPOSURE C AND INTERNAL PRESSURE COEFFICI CONDITION I. 2X4 OR MAX. 1'-6" WIOUT LEDGER P'ER AND HANGER (BY BLDR.) A. MAX. 4'-6" 4 s 2 APPRO f COMBgS �O.1JC. DES. BY �� M oAOE rRuss = CHECKED BY-;— Company Inc. * v DATE • 01101/21 6401 N.W. 74 AVE MIAMI, FLA. 33168 !+ 2 DADE {306} 6924245 BROWARD (305) 462MU � � �A� �F •* l � a~ DRAWING MM WATW 14M.M.7842 FAX: (306) 4T743= p`T �'i JOB No. 7ah,, ANAL7 ti+ ��ierrrrlr111�N1N���� Minimun Grade Of Lumber PLATES ARE MITEK M20-249,200 MANUFACTURED FROM ASTM A 466 GRD A GALVANIZED STEEL (EXCEPT AS SHOWN) 2X4 Syp. No. 2SP PLATE MUST BE INSTALLED ON EA. FACE OF JOINT SYMMETRICALLY (EXCEPT AS SHOWN) DESIGN CONFORMS W/NDS SPECS, FBC 2020 THIS DESIGN IS FOR TRUSS FABRICATION ONLY. FOR PERMANENT BRACING (WHICH IS ALWAYS REGO.) CONSULT BLDG, ARCHITEC INDICATES DEAD LOAD ON U i 8# 601 —' R 92-- tau 1 ,42' .25' oa' O 12 A) ALL CONNECTORS SPEC. MUST BE INSTALLED PER MFG. SPECIFICATIONS. B) HANGERS REQ'D FOR TRUSSES LESS THAN 12'-0•' SPAN (UNDER 650# (REACTIONS) MUST BE SUPPLIED BY BLDR. C) FOR TRUSS DATA, LUMBER, PLATES, ETC. REFER TO INDIVIDUAL ENG. DRAWINGS3. D) THIS HIP SET HAS BEEN DESIGNED FOR THE LOADS GENERATED BY 146 MPH WINDS AT 25 FT. ABOVE GROUND LEVELASCE 7-16 COMPONENTS AND CLADDINCG AND 7.0 PS TOP CHORD AND 3.0 PSF BOTT. CHORD DEAD LOAD ARE 8EING USED. THE DESIGN ASSUMES OCCUPANCY CATEGORY II, TERRAIN EXPOSURE C AND INTERNAL PRESSURE COEFFICIENT CONDITION 1. TO 303 THROUGH JO7) '-0" TO 7'-0" PA1 USP ANGLE (OR EQUAL) AND -16d TOE NAILS (BY BLDR.) 0. 01-0417-11 tMAX. REACTION 395# 16d TOE NAILS] q�11% 2-16d TOE NAILS _ •i `' V LOADING. PS APPRO'I E TRIES CD. INC-- BY ; MM TOP WE 30 r$IECKED BY : � TOP DEAD : 15 JACK DETAIL (7'-Q" SETBACK) Hang TRUSS STATE OF ; t TT: 0�10121 BOAON 10 6101 ILA- 74 A` R YIAW. 1A. S11 .���i�`'•;�1ORID� .•'r��� RAWING - -- u,oc w� G,aer1 te n.: • ... •:.1,C)� _.,- JO8 No. Minimun Grade Of Lumber PLATES ARE MIIEY, M20-249,200 MANUFACTURE) FROM ASTM A 466 GRID 4 GALVANIZED STEEL (EXCEPT AS SHOWN) 2X.4 Syp. No. 2 SP PL4"E MUST BE INSTALLED ON EA FACE OF JOINT SYMMETRICALLY (EXCEL'' AS SHOWN) DESIGN CONFORMS WADS SPECS. FBC 2020 THIS DESIGN IS FOR TRUSS FABRICATION ONLY. FOR PERMANENT BRACING (WHICH IS ALWAYS REOD.) CONSULT BLDG. ARCI ITEC I IC, C USF 1" 20G CALVE. METAL STRAP NAILED W/2-10d NAILS ON EA. MEUBER, PER FACE, OR 2 HURRICANE Cl IPS. ONE ON E.A. FACE OF TRUSS. (BY BLDR.) TYP, VALLEY SET CONNECTION DETAI PITCH VARIES 6' WEDGE NAILED TO TRUSS W/2-1Gd NAILS. (BY BLDR.) TYP. ae,52�!� 0400 DADE TRUSS cam., 6401 N V 74 AVE- MIAMI. PTA 33166 DA 130) %2-824S IIRIYMR 0%) %- curs: ,-sae-YA-7842 W: 0014 AM qr. VERTICALS 9 6'-0" O C Vd X. OVER 24'-Q" 20-0' AND OVER VAL E 2' MAS-151DI TRUSS SYMMETRICAL ABOUT CENTER LINE EXCEPT AS SHCOWN SPL. 00F C F �o I'oR rI 1 3 S6. 'INC. S STATE OF �.aa ONAL ��.a�``;� y 2X4 WI LEY CATS (EY SLRR.) IRUSS Es. By NIM jH;:CKED BY SJ FATE _ 01101121 "RAWING JOB No. Minimun Grade Of Lumber 2X4 Syp. No. 2 SP PLATES ARE MITEK M20-249,200 MANUFACTURED FROM ASTM A 466 GRD A GALVANIZED STEEL (EXCEPT AS SHOWN) PLATE MUST BE INSTALLED ON EA. FACE OF JOINT SYMMETRICALLY (EXCEPT AS SHOWN) DESIGN CONFORMS W/NDS SPECS, FBC 2020 THIS DESIGN IS FOR TRUSS FABRICATION ONLY. FOR PERMANENT BRACING (WHICH IS ALWAYS READ.) CONSULT BLDG. ARCHITEC iZLC BC CONNECTED TO A FIXED RICIO PONT OR X-BRACED AS NOTED ON THIS DETAIL. lIN a 213 LATERAL BRACE PER TRUSS DESIGN TOTH 2-104 NAILS PER WES FOR FORCES UP TG 4600 lws- FORCES IN EXCESS OF 4600 Ibs RE009MS 2116 /J OR BETTER. NOTE PROVIDE X-BRACING AT 29Y-O' INTERVAL$ FOR wE6 FORCES UP TO 2M III& AND AT 10'-0' FOR FORCE GREATER THAN 2309 Ibc 'cFT'Ihr'-zw4) LATERAL BRACING DETAIL ALT. LATERAL BRACING DETAIL toe o a' j�—O.C. TlP rt TRUSSES O 24'lrT-BRACE SAG( SIZE O.N: LtP AND GRADE AS We T-BRACE KITH WEB (24 µAx; IOd NAYS O a' O.C. TYP. WEB SECTION DETAIL NOTE; BRACE LNTST BE 809 THE LENGTH OF THE WES. THIS DETAIL IS 70 BE USED AS AN ALTERNATE FOR CONTINUOUS LATERAL BRACE4. LATERAL BRACING DETAIL 4ADcmem ,ass Wl 11A. 74 ATE. 1Q1fQ. 1Ll 33166 s10E Ross W-M WIMM Rob) 40-IM 1:ATI5 1-900-3e-M2 Fix pQ 4n-M E FOR DADVRUSS,Co:• III. STATE G)P ,q D . BY MM C CKED BY SJ D 1 : OvOvu DRAWING JOB No. Hanger Index HangerOptionsMatrix................... ...... ............. 98-99 Solid Sawn Joist Hangers • Face Mount ............................................. 100-119 • Sloped and Skewed ................................ 114-119 • Top Flange ............................................... 122-134 • Specialty ........................................... 120,136-137 Fire Wall Hangers ......................................... 229--233 Hanger Load Table Explanation ' ' This icon identifies products approved for installation with Simpson Strong -Tie Strong -Drive SD Connector screw. See pp. 335-337 for more information. Gauge: Min./Max.: Refers to min. or max, nailing for products with round and triangle holes. Min. nailing uses round holes. and max, nailing uses round and triangle holes to achieve maximum load. I Joist Size: Model No.: Product Nails: This shows This shows This is the material the fastener the size of Simpson thickness. quantity and type joist member. Strong -Tie required to product name. achieve the table loads. v i SIMPSON Strong. -Tie I -Joist, Glulam and Structural Composite Lumber Connectors • Face Mount ............................................. 139-150 • Adjustab e........................................................ 151 • Sloped and Skewed ................................ 152-155 • Top Flange ............................................. 159-183 Plated Truss Connectors .............................. 186-228 Masonry and Concrete Connectors ............. 234-259 Load Duration: Installed Cost Index: Assumed duration factor used This indicates the to determine the allowable load. products relative installed cost (combined cost and Allowable Design Loads: The inslallatK,n cost). maximum load that a-..:cti,� is designed to provide Uplift Floor, Snow, Roof, Da I A_`� Dimensions (in.} Faste rs (in.) DF/SP Allowable Loads installed Joist Model Ca' MinJ Cost Index Code Size Na. Max. Header Joist UpliftTF,17oorinow Roof (ICI) Ref. (160}115) (i25) Sawn Lumber Sizes LUS26-2 18 31 s 4'/4 2 -4' 0162 x 31/2 (410.162 x 311 1,060 1.030 1,170 1.265 Laresl U26-2 16 31/8 5 2 (8 0,162 x 31/2 (4) 0.148 x 11/2 535 1.150 1.305 1.410 +65% 2X6 HUS26-2 14 31s 5416 2 I — 14) 0162 x 3'h (4) 0.162 x 3'1h 1.165 11055 1.195 1.290 +172% IBC, L LA 14 314 53A 2'k Min 18) 0162 x 31,, (4) 0148 x 1'k 755 1190 1.345 1.440 +233% HU26.21HUC26-2 14 I 1 s 5Vs 1 2'h Max 112) 0.162 x 3,5 (6) 0148 x i '1h 1 135 1185 2,015 2,165 +254% This icon identifies products that are available with additional corrosion protection. See p.12 for additional information. 94 \V Dimensions W, H, B: This shows the product dimensions (width, height and bearing length in this case.) referenced in the product drawrin g. Nails: 0.162" x 31/2", 0.148- x 1 %2". Code Ref.: See pp. 21-22 for other nail sizes aril information. See p.12 for the Code Reference Throughout this catalog, the table Key Chart, to fastener size indicates the required nail determine wh'ch diameter and length. See pp. 21-22 for code reports load adjustment factors for alternative include this fasteners used with some connectors. product All installations should be designed only in accordance with the allowable load values set forth in this catalog. Product Drawing: Provides a graphic presentation of the product with dimensional information (often cross referenced to the table). LUS/MUS/HUS/HHUS/HGUS Face -Mount Joist Hangers This product is preferable to similar connectors because W of a) easier installation, b) higher loads, c) lower installed cost, or a combination of these features. T ho r1QLA Q sheer hangf,' :i4'ms, ranging frotn the light Capacity LUS halige:s to the highost•capa:itvd Hf SUS hangers, feitt,re innovative double shear nailing that distriE utes the load through Nvo points on each joist nail for greatL3r Strength, This allows for fewer nails, faster installation and the use of all common nails for the same connection. For medium -load truss applications, the MUS offers a lower -cost alternative and easier installation than the HUS or THA hangers, while providing greater load capacity and bearing than the LUS. Material: See tables on pp. 194-195 Finish: Galvanized. Some products available in stainless steel or ZMAX" coating. See Corrosion Information, pp. 13-15. Installation: • Use all specified fasteners; see General Notes. • Nails must be driven at an angle through the joist or truss into the header to achieve the table loads. • Not designed for welded or nailer applications. Options: • LUS and MUS hangers cannot be modified • Concealed flanges are not available for HGUS and HHUS • Other sizes available; consult your Simpson Strong -Tie representative Cedes: See p.12 for Code Reference Key Chart 6 Double -Shear Nailing Top View Double -Shear Nailing Side View Do not bend tab Dome Double -Shear Nailing Side View (Available on some models) V 1or 2x's f Vk, for 4Xs e Z- I I} a C O e 0 HI C c � I s W . 8 LUS28 6 HHUS210-2 e�tr ol� � 6 6 ha. w G 4 c �• � � • gulri C g • G• 2 �`L 6MUS28 I • o i d .e OHUS210 ' (HUS26, HUS2$ and HHUS similar) T 0at_ B HGUS28-2 Typical HUS26 Installation with Reduced Heel Height (multiple member fastening by Designer) 12 a 0 "M93 4 IL 0 LUS/MUS/HUS/HHUS/HGUS Face -Mount Joist Hangers (cont.) Model No. Min. Height Ga.Heel Dimensions (in,) Fasteners W H I g Carrying Member Carried Member Single 2x Sizes LUS24 2% 18 13is 3 %6 1 V. (4) 0.148 x 3 (210.148 x 3 LUS26 4h. 1%6 4VA 13/. (4)0.148x3 (410.148x3 MUS26 4'Ye 18 11t6 51tb 2 (6) 0.148x3 M 0148 x 3 HUS26 06 16 1 sib 5% 3 04) 0,162 x 3 �i (6) 0.162 x 3'h HGUS26 4Vs 12 1 % 5% 5 {20) 0.162 x 31h (8) 0.162 x 3'A LUS28 06 18 1 �16 6% 1 Y4 (6) 0.148 x 3 (4) 0.148 x 3 MUS28 13% 18 19A6 61,i6 2 (8) 0148 x 3 (8)0.148 x 3 HUS26 6Fk 16 1 % 7 3 12211l 0.162 x 31b (8) 0.162 x 31/z HGUS28 6% 12 1 % 71/e 5 (36) 0162 x 31h (12) 0162 x 31/2 LUS210 4+/4 18 1 i6 714'ie 1 ]4 (8) 0.148 x 3 (410.148 x 3 H US210 83'6 16 1 % 9 3 (30) 0.162 x 3'h (10) 0162 x 31k H' S210 8;,, 12 1 % 914 5 (46) 0.162 x 3'/k 1 (16) 0.162 x 3'k 1. See table below for allowable loads. SIMPSON Strong -Tie These products are available with additional corrosion protection For more information, see p.15, Q For stainless -steel fasteners, see p. 21. Many of these products are approved for installation Mwith SlroRg-Drivel SD Connector screws. See pp. 335-337 for more information. Mode! DF Allowable Loads Allowable Loads SPF/HF Allowable Loads Code No. Uplift (160) Floor (100) Snow. (115) Roof {125) Wind Uplift (164) (160)) EF1,11r Snow (115) Roof (125} Wind (160} Uplift (160) Floor Snow (100} 1(115) Roof (125) Wind (160) Ref. Single 2x Sizes LUS24 435 670 765 820 1.045 435 725 825 890 1,120 360 495 1 565 (305 770 LUS26 1,165 865 990 1,070 1.355 1.165 935 1,070 1,150 1.475 865 635 725 785 1,000 113C. FL, MUS26 930 1.295 1,480 1.560 -1,560 930 1,405 1,560 1,5G0 1,560 810 955 1,090 1,180 1,350 LA HUS26 1,320 2.735 3.095 3.235 3235 1,32.0 2.960 3.20.0 3,2.60 3.280 1,151) 2.350 2.660 2,780 2,760 HGUS26 875 4.340 4.850 5.170 5,390 875 4.690 5,220 5,390 5,390 180 3,225 3,610 3,810 3,985 113C. FL LUS28 1,165 1.100 1,260 1,350 1.725 1.165 1,195 1.360 1,465 1.730 865 810 925 1,000 1.270 MUS28 1.320 1.730 1,975 2,125 2,255 1.320 1,875 2,135 2,255 2,255 1.150 1,270 1,455 1,575 1,955 IBC, fL. LA HUS28 1.760 4.095 4.095 4.095 4.095 1.760 4,095 4.095 4.095 a i#95 1.380 3.520 3,520 3,520 3,520 HGUS28 1.650 7.275 7.275 7.275 7.275, 1,650 7,275 7.275 7,275 7,275 1,325 3.670 3,820 3.915 4.250 IBC. FL LUS210 1,165 1.335 1.530 1.640 2,090 1,165 1,450 1.655 1.775 2.270 865 985 1,120 1,215 1.500 18C, FL. HUS210 2,635 5,450 5,795 5.830 5.830 2.635 5,395 5.780 5.830 5.830 2.220 4,685 4,965 5.015 5,015 LA HGUS210 2,090 9.100 9.100 9.100 9100 2.090 9100 9.100 9.100 9.1a?0 1.145 6.340 6,730 5.730 6.730 1 19C. FL 1. For dmensions and fastener information. see table ab(ve. See table footnotes on p. 195. HHUS/HGUS See Hanger Options information on pp.98-99. HHUS - Sloped and/or Skewed Seat • HHUS hangers Can be skewed to a maximum of 45" and;'or Sloped to a maximum of 45' • For skew only, maximum allowable download is :).85 of the table load • For sloped only or sloped and skewed Clangers, the maximum allowable download is 0.65 of the table load • Uplift loads for sloped/skewed conditions are 0 72 of the tattle load, not to exceed 2 4i'S lb. • The joist must be bevel -cut to allow for double shear na ng HGUS - Skewed Seat • HGUS hangers can be skewed only to a maximum of 45`. Allowable loads are HGUS Seat Width Joist Down Load Uplift W < 2" Square cut 0.62 of table load 0.46 of table load W < 2" Bevel cut 0.72 of table bad 0.46 of table load 2" < W < 6" Bevel cut 0.85 of table load 0.41 of table load 2" < W < 6" Square cut 0.46 of table load 0.41 of table load W > 6" Bevel cut 0.85 of table load 0.41 of table load Acute - side Specify angle Top View HHUS Hanger Skewed Right {foist must be bevel cut) All joist nails installed on the outside angle (non -acute side). 154 UPDATED 12/01/20 LUS/MUS/HUS/HHUS/HGUS These products are available with For stainless additional corrosion protection. ,ti steel fasteners. For more information, see p. 15, see p. 21. Many of these products are approved for installation ®1 with Strong -Drives SD Connector screws. See pp. 335-337 for more information, SIMPSON Strong. -Tie Model Min. Dimensions (in.) Fasteners (in.) DF/SP Allowable Loads SPF/HF Allowable Loads Heel Height Ga. W H g Carrying Member Carried Member Uplift (i60) Floor {100} Snow oof (115) 1('125) Wind (160) Uplift (160) Floor (100) Snow (115) Root (125) Wind (160) Code Ref. Double 2x Sizes LUS24-2 2Y, 18 1 3% 31'A 2 (4) 0.162 x 3'h (2) 0.162 x 35h 410 800 905 980 1.245 355 690 1 780 845 11,0701 LUS26.2 4s/6 18 3'/e 4'A 2 (4) 0.162 x 31h (4) 0.162 x 3'h 1.060 1,030 1,170 1,265 1,595 910 885 11,005 1,090 11.370 HHUS26-2 43i6 14 3?i6 5311 3 (14) 0.162 x 3 h (6) 0.162 x 31h 1.329 2.830 3.190 3.415 4.250 1,135 2,435 2,745 2.935 3,655 HGUS26-2 06 12 N6 5'/16 4 (20) 0.162 x 3112 (8) 0.162 x 31/2 2,155 4.340 4,850 5.170 5,575 1,855 3.730 4.170 4,445 4.795 LUS28.2 43i6 18 31/e 7 2 (6) 0.162 x 3'h (4) 0.162 x 3'h 1.060 1,315 1,490 1,610 2,030 910 1.130 1,280 1.385 1,745 IBC. FL, HHUS28-2 6% 14 3316 71/4 3 122) 0.162 x 31h (8) 0.162 x 31h 1,760 4,265 4,810 5.155 5.980 1.515 3.670 4.135 4,435 5,145 LA HGUS28-2 69A6 12 39i6 7346 4 (36) 0.162 x 31h (12) 0.162 x 31h 3,235 7,460 7,460 7,460 7.460 2,780 6,415 6.415 6.415 6,415 LUS210-2 06 18 31/e 9 2 (8) 0.162 x 3112 (6) 0.162 x 31h 1.445 1.830 2,075 2.245 2.830 1,245 1.575 1,785 1.930 2,435 HHUS210-2 81h 14 3Yi6 8'/e 3 130) 0,162 x 31h (10) 0.162 x 316 3. ,50 5,705 6.435 6.185 6.485 3.33 4.905 5.340 5.060 5,190 HGUS210-2 89A6 12 33i6 9316 4 (46) 0.162 x 31h (16) 0.162 x 31h 4.095 9.100 9,100 9.100 9.100 3,520 17.460 7,825 7,825 7.825 Triple 2x Sizes HGUS26 3 41346 12 4IV, 0.162 x 31h (8) 0.162 x 3 2,155 4,340 4,850 5.170 5.575 1,855 3,73D 4,170 4,445 4,795 IBC, FL. HGUS28-3 61346 12 410.162 x 31h (12) 0.162 x 3'h 3235 7,460 7.460 7,460 7.460 2,780 6.415 6,415 6,415 6,415 LA HHUS210.3 83'a 14 4 0.162 x 31k (10) 0.162 x 31h 3.405 5.630 6,375 6,485 6,485 2,930 4,840 5,485 5.575 5.575 FL HGUS210-3 8'3i6 12 40.162 Js5 t4(20) x 31h (16) 0.162 x 31h 4.095 9.100 9,100 9.100 9.100 3.520 7.825 7.825 7,825 7,825 HGUS212-3 10% 12 40.162 x 31h (20) 0.162 x 3'h 5,695 9,045 9,045 9.045 9.045 4.900 7,780 7,780 7.780 7. 880 lBC FL. LA HGUS214.3 12% 12 410.162 x 31h (22) 0.162 x 3 h 5,695 10,125 10,125 10,125 10.125 4,900 8,190 8,190 8.190 8,190 Ouadruple 2x Sizes HGUS26-4 516 12 63i6 5%6 4 (20) 0.162 x 31h 8) 0.162 x 3'/s 2,155 4,340 '4,850 5,170 5,575 1,855 3.730 4,170 4,445 4,795 IBC. FL, HGUS28-4 7'/a 12 6V% 73i6 4 (36) 0.162 x 31h (12) 0.162 x 316 3.235 7,460 7.460 7,460 7,460 2.780 6,415 6.415 6,415 6.415 LA HHUS210-4 Re 14 6'/s 8'/e 3 (30) 0.162 x 3112 (10) 0.162 x 31h 3,405 5,630 6.375 6.485 6,485 2,930 4.840 5.485 5,575 5.575 FL HGUS210-4 9'/4 12 69/4 9Y% 4 (46) 0.162 x 3'h (16) 0.162 x 31h 4.095 9,100 9,100 9.100 9.100 3.520 7.825 7,825 7,825 7.825 HGUS212.4 10% 12 6%e, 10% 4 (56) 0.162 x 31h (20) 0.162 x 31h 5.695 9,045 9.045 9.045 9,045 4.900 7.780 7,780 7.780 T780 IBC FL. LA HGU5214-4 126% 12 63'+6 12% 4 (66) 0.162 x 3'h (22) 0.162 x 31h 5.695 10,125 10.125 10.125 10.125 4,900 8,710 8,710 8.710 8,710 4x Sizes LUS46 4% 18 3% 43r4 2 (4) 0.162 x 31h (4) 0.162 x 3 h 1.060 1,030 1,170 1,265 1,595 010 885 1,005 1,090 1.370 IBC. FL HGUS46 4'h6 12 3% 4T/16 4 (20) 0.162 x 31h (8) 0.162 x 3'k 2,155 4.340 4,850 5.170 5,575 1,855 3,730 4.170 4,445 4,795 HHUS46 45/% 14 3% 53i6 3 (14) 0.162 x 31h (6) 0.162 x 31h 1,320 2,830 3,190 3,415 4,250 1.135 2.435 2.745 2,935 3.655 LUS48 43A 18 39iis 63/4 2 (610.162 x 3'h (4) 0.162 x 31h 1.060 1,315 1,490 1.610 2,030 910 1,130 1,280 1,385 1,745 16C, FL. HUS48 0'•`.4 14 34116 7 2 (6) 0.162 x 31h (6) 0.162 x 3'h 1,320 1.580 1.790 1,930 2,415 1,135 1.360 1.540 1,660 2.075 LA HHUS48 61/5 14 3% 71h 3 (22) 0.162 x 3112 (8) 0.162 x 3'h 1:; iii) 4.265 1 4,810 5.155 5,980 1.515 3,670 4,135 4,435 5,145 HGUS48 06 12 3% 7'`is 4 (36) 0.162 x 31h (12) 0.162 x 31h 3.235 7.460 17.460 7,460 7,460 2.780 6,415 6.415 6,415 6,415 LUS410 61/4 18 334e 83'4 2 (8) 0.162 x 31/z (6) 0.162 x 31h 4,445 1.830 2,075 2.245 2,830 1,245 1.575 1.785 1,930 2.435 HHUS410 8% 14 3% 9 3 (30) 0.162 x 31h (10) 0,162 x 31h 3,550 5.705 6,435 6.485 6,485 3,265 4.905 5.535 5.575 5,575 HGUS410 8'/16 12 3% 9Y6 4 (46) 0.162 x 31h (16) 0.162 x 3 Si 4.095 9,100 9,100 9,100 9,100 3,520 7,825 7,825 7,825 7,825 IBC. FL, LA HGU5412 10%6 12 311/9 101A6 4 (56) 0.162 x 31h (20) 0.162 x 31h 5 695 9.045 9.045 9.C1145 ..045 4,900 7,780 7.7,'X) 7.780 7.780 HGUS414 11 % 12 3% 12%6 4 (66) 0.162 x 31h (2210.162 x 31/2 5,695 10,125 10.125 10.125 10.i25 4.90D 8.190 8.190 8.190 8,190 Double 4x Sizes 7,820 7.820 HGOS7.37/10 8'/16 12 1 73i 8%, J 4 J (46) 0.162 x 3'h (16) 0.162 x 31/r 3.430 9,095 9.095 9.095 9,095 2,950 7.820 7,820 HGUS7.37/12 10'/6 12 73fr 10s 4 1 (56) 0162 x 31h (20) 0.162 x 31h 1 3,835 9,295 9,295 9,295 9,295 3.300 7,995 7,995 7,995 7,995 FL HGUS7.37114 11 ?F6 12 1 735 123,E 4 1 (66) 0.162 x 31h (22) 0.162 x 31h 5,080 10,50010,500 10,500 10,500 4,370 9,030 9,030 9.fl30 9,D30 1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern. 2. Wind (160) is a download rating. 3. Minimum heel height shown is required to achieve full tab€e loads. For less than minimum heel height, see technical bulletin T-C-REDHEEL at strongtie.com. 4. Truss chord cross -grain tension may limit allowable loads in accordance with ANSI/TPI 1-2014. Simpson Strong -Tie- Connector SefectW software includes the evaluation of cross -grain tension in its hanger allowable loads. For additional information, contact Simpson Strong -Tie, 5. Loads shown are based on a Nvo-ply 2x carrying member minimum for nailed hangers. with 3x carryng members, use 0.162' x 21h' nails in the header and 0.162' x 3'h' in the joist, with no load reduction. With single 2x carrying members, use 0.148' x 1 h* nars in the header and 0.148' x 3' in the joist. and reduce the load to 0.64 of the table value. 6. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. IL I 195 UPDATED 12/01/20 HTU Face -Mount Truss Hanger The HTU face -mount truss hanger has nail patterns designed specifically for shallow heel heights, so that full allowable loads (with minimum nailing) apply to heel heights as low as 37/a'. Minimum and maximum nailing options provide solutions for varying heel heights and end conditions. Altemate allowable loads are prov ded for gaps between the end of the truss and the carrying member up to 1/2" max. to allow for greater construction tolerances (maximum gap for standard allowable loads is'/V per ASTM D1761 and D7147). See technical bulletin T-C-HANGERGAP at strongtie.com for more information. Material: 16 gauge 12 Finish: Galvanized 06 Installation: • Use all specified fasteners; see General Notes C C • Can be installed filling round holes only, or filling U round and triangle holes for maximum values • See alternate installation for applications 3 using the HTU26 on a 2x4 carrying member or H HTU28 or HTU210 on a 2x6 carrying member 'd for additional uplift capacity Options: d • HTU may be skewed up to 67 Y. See Hanger Options on pp. 98-99 for allowable loads. • See engineering letter L-C-HTUSD at strongtie.com for installation with Strong -Driver SD fasteners. Cotles: See p.12 for Code Reference Key Chan Mm, heel height per table t3Many of these products are approved for installation wth EArong-orn;e' SD Connector screws. See pp. 325-337 fw more information HTU26 truss and carrying member HTU Installation for Standard Allowable Loads go('h' manmum gap, use Alternate Allowable Loads.) Standard Aliowable Loads (1/8" Maximum Hanger Gap) SIMPSON Strong -Tie Typical HTU26 Minimum Nailing Installation Alternate Installation - HTU28 Installed on 2x6 Carrying Member (HI'U210 s+milar) Model Min. Dimensions (in.) Fasteners (in.) DF/SP Allowable Loads SPF/HF Allowable Loads Cade No. Heel Height W H g Carrying Member Carried Member Uplift (160} Floor (100) 1 Snow (115) Roof (125) Wind (160) Uplift (1601 Floor (100) Snow Roof (115)1 (125) Wind (160} Ref. Single 2x Sizes HTU26 3V6 14% 5'/rb 3'h (20) 0.162 x 3 �i (11) 0.148 x 11h 640 2.070 1 2,670 2,670 2,670 550 1.68{} 1,680 1,680 1.680 HTU26 (Min.) 3% 14% 51A6 31h (20) 0.162 x 31/2 (14) 0.148 x 1 Vi 1,250 2,940 3,200 3,200 3,200 1,075 1,852 2,015 2015, 2,015 HTU26 (Max.) 5Vi 15.% 57% 3'h (20) 0.162 x 31h (20) 0.148 x 11h 1,555 .2,940 3,320 3,580 4.010 1,335 2.530 2.855 3.080 3,450 IBC. HTU28 (Min.) 3'h 1 % 7 y1a 31h (26) 0.162 x 31h (14) 0.148 x 1 Va 1,235 3,820 3.895 3,895 3,895 1,060 2,865 2,920 1 2.920 2,920 FL, HTU28 (Max.) 7 /. 13% 7 Yie 31/2 (26) 0.162 x 31f2 (26) 0.148 x 1 Yz 2,02ii 3,820 4.315 4.655 5.435 1,l35 3,2$5 3,T 1(1 4,Oi}5 4,675 LA HTU210 (Min.) 3'/1 13% 9f5s 3'h (32) 0.162 x 31h (14) 0.148 x 116 1.330 4.300 4,300 4.300 4.300 1,145 3,225 3,225 1 3,225 _1225 HTU210 (Max.) 9Vi 15A 9A, 3'h {32) 0.162 x 3'h (32) 0.148 x 1 Fh 3.315 4,705 5.310 5,730 5,995 2,850 4,045 4,54335 1 41930 5,155 Double 2x Sizes HTU26-2 (Min.) 37/8 34i6 5'tis 3'h (20) 0.162 x 31h (14) 0.148 x 3 1.515 2.940 3.320 3.580 3,910 1.305 1.850 2.090 2.255 2,465 HTU26-2 (Max.) 5'h 3#e 5% 3'h {20) 0.162 x 31h (20) 0.148 x 3 2,175 2,940 3,320 3.580 4,480 1,870 2,530 2.855 3,080 3.855 HTU28-2 (Min.) 3'/s 3` T6 7 %e 3 h (26) 0.162 x 314 (14) 0.148 x 3 1.530 3,820 4.310 4.310 4,310 1,315 2.865 3.235 3,235 3,235 IBC. HTU28-2 (Max.) 7'ii 31As 7%6 3 r5 (26) 0.162 x 3'h (26) 0.148 x 3 3.485 3.820 4,315 4,655 5 325 2.995 3.285 3,710 4.005 5.01p LA LA HTU210-2 (Min.) 3'A 3%6 9AG 3Vr (32) 0.162 x 3 � (14) 0.148 x 3 1.755 4,705 4.815 4,815 4,815 1.510 3.530 3,610 3.610 3,610 HTU210-2 (Max.) 9V, 3`✓s 9Vrs 31h (32) 0.162 x 3Vi (32) 0.148 x 3 4,110 4.705 5.310 5,730 1 6.515 3.535 4.045 4,565 4.930 5.605 1, The maximum hanger gap is measured between the joist (or truss} end and the carrying member, 2. Minimum heel heights required for full table loads are based on a minimum 2 12 pitch. 3. Uplift loads have been increased for earthquake or wind loading with no lurther increase allowed. Reduce where other loads govern. 4. Wind (160) is a download rating. 3. For hanger gaps between 'A' and %V. ise the Alternate Allowable Loads. t;. Truss chard cross -grain tension may linrt allowable oads in accordance with ANSIITPI 1-2014, Simpson Strong-Tre° Connector Selector° software includes the evaluation of cross -grain tension in its hanger allowable loads. For additional information, contact Simpson Stfong-Tie. 1, Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148' x 11/2" nails in the header and reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table load B. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. 196 HTU Face -Mount Truss Hanger (cont.) MMany of these products are approved for installation with Strong -Drive° SD Connector screws. See pp. 335-337 for more information. Alternate Installation Table for 2x4 and 2x6 Carrying Member Strong -Tie Min. Minimum Fasteners (in.) DF/SP Allowable Loads SPF/HF Allowable Loads Model No. Heel Height Carrying Cade Ref. Carrying Carried Uplift Floor Snow Roof Wind Uplift Floor Snow Roof Wind (in.) Member Member Member (160) (100) (115) (125) (160) (160) (100) (115) (125) (160) HTU26 (Min.) 37/s (2) 2x4 (10) 0.162 x 3112 (14) 0.146 x 1'h 647, 1.470 1,660 1.790 1.875 795 1,265 1,430 1,540 1.615 HTU26(Max.) 5'h (2) 2x4 (10) 0.162 x 31h (20) 0.148 x 1 h 1.240 1.470 1.660 1.790 2.220 101d5 1,265 1,430 1.540 1.910 IBC, HTU28 (Max) 71/4 (2) 2x6 (20) 0,162 x 31/2 1 (26) 0.448 x 11h 1.920 21940 3.320 3,580 3,905 1 1.650 1 2,530 1 2.855 3.080 3,360 FL. LA HTU210 (Max.) 9'/. (2) 2x6 (20) 0.162 x 31h 1 (32) 0.148 x 1 &1 2,860 2,940 3,320 1 3,580 1 3,905 1 2,475 1 2,530 1 2.855 13,080 1 3.360 1. See table below for dimensions and additional footnotes. 2. Maximum hanger gap for the alternative installation is W. 3. Wind (160) is a download rating. 4. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21 22 for fastener snforrnaiiiiDL Alternative Allowable Loads (1/2" Maximum Hanger Gap) Min. Dimensions (in.) Fasteners (in.) DF/SP Allowable Loads SPFIHF Allowable Loads Model No. Heel Height W H D Carrying Carried Member Member Uplift (160j Floor (100) Snow (115) Roof (125) Wind (160) Uplift Floor (160j (100) Snow (115) Roof (125) Wind (160) Code Ref, Single 2x Sizes HTU26 3'h I % 5?A6 31h (20) 0.162 x 3'/a (11) 0.148 x 1 %z 635 2,395 2.395 2 395 2.395 545 1510 1 510 1.510 1,510 HTU26 (Min.) 3'/s 1 %5'/a 3'h (20) 0.162 x 31h (14) 0.148 x 11h 1.175 2,940 3,100 3.100 3,100 1.010 1,955 1,955 1.955 1.955 HTU26 (Max.) 51h 1 % 5'A5 3% (20) 0.162 x 3'h (20) 0.148 x 11h 1.215 2.940 3.320 3,580 3.630 1.045 1.850 2.090 2,285 2,285 IBC, HTU28 (Min.) 3'/s 15/e 7 s16 3'h (26) 0.162 x 3'h (14) 0.148 x 11/2 1,110 3.770 3.770 3,770 3.770 955 2.825 2,825 2.825 2,825 FL. HTU28 (Max,l 7'/. 1 % 711+6 31h (26) 0.162 x 31/s (26) 0,148 x 1'/2 1,920 3,820 :.:i15 1.655 5,015 1,695 2.865 :!,235 3,490 3.765 LA HTU210 'Min) 3'/s 1 % 9Y+s 31h (32) 0.162 x 31h (14) 0.148 x 1 h 1,250 3,600 3,600 3.600 3.600 1,075 2.700 2.700 2,700 2,700 HTU210 ;Max ;, 9'/4 15fa 9Ys6 3'h (32) 0.162 x 31z (32) 0.148 x 1'h 3,255 4,705 5,020 5,020 5 020 2.800 3.530 3,765 3,765 3,765 Double 2x Sizes HTU26-2 ;Min.) 3'/6 3�i6 5h6 31z (20) 0.162 x 3 t,� (14) 0,148 x 3 1,515 2,940 3.32C 3,500 3,500 1,305 2205 2205 2.205 2.205 HTU26 2 (Max.) 51h 3Na 59is 3 h (20) 0.162 x 3 h (20) 0.148 x 3 1,910 2,940 3.3ft. 3.500 3.500 1,645 2,205 2205 2.205 2.205 HTU28 2 ;Min.) 3'/9 3-166 7 Yi6 3'/z (26J 0.162 x 3 1h (14) 0.148 x 3 1.490 3.820 3,980 3.980 3,980 1.280 2,865 2,985 2,985 2,985 IBC FL HTU28-2 (Max) 71/4 3Vis 7Yi6 31h (26) 0.162 x 3'h (26) 0.148 x 3 3,035 3.820 4.315 4.655 5,520 2,610 2.865 3.= ? i 9.490 4 14;; LA HTU210-2 (Min) 3'/a 35/i6 9 vs 3'h (32) 0.162 x 31h (14) 0,148 x 3 1 1,755 4.255 4.255 4,255 4.255 1,510 1 3,190 3,190 3,190 3,190 HTU210.2 (Max.) 9114 Vie, 9 Ys 316 (32) 0.162 x 31h (32) 0.148 x 3 3,855 4.705 1 5,310 5,130 6,470 3.315 1 3.530 3.980 4,300 4,855 1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member. 2. Minimum heel heights required for full table loads are based on a minimum 2:12 pitch. 3. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern 4. Wind (160) is a download rating. 5. For hanger gaps between'/' and'/', use the Alternate Allowable Loads. 6. Truss chord cross -grain tension may limit allowable loads in accordance with ANSIfTPI 1-2014. Simpson Strong -Tie' Connector Selector software includes the evaluation of cross -grain tension in its hanger allowable loads. For additional information, contact Simpson Strong -Tie. 7. Loads shrnvn are based on a minimum two-pty 2x carrying member. For single 2x carrying members. use 0.149- x 16 i nails in the header and reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table load. B. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. L 197 UPDATED 06/01/19 ■ HTU Face -Mount Truss Hanger (cont.) Options: See Hanger Options information on pp, 98-99, Skewed Seat • Skewable up to 67 h° • Available in single and two-ply size • No bevel cut required Allowable Loads for Skewed HTU Hangers Model No. Skew Angle (Degree) Fasteners (in,) DFISP Allowable Loads SPF/HF Allowable Loads Carrying Member Carried Member Uplift (160) Download (10011151125) Uplift (160) Download (10011151125) < 51 (20) 0.162 x 31h (14) 0.148 x 1'h 1.315 2,945 1,130 2.530 HTU26 51-671h (20) 0.162 x 3 h (12) 0.148 x 11h 970 2.595 835 2,230 < 51 (26) 0.162 x 3 h (20) 0.148 x 1'h 2.015 3 060 1730 2.630 HTU28 51.67 h (26) 0.162 x 3 h (17) 0.148 x 1 !6 1,485 2.815 1280 2,420 < 51 (32) 0.162 x 31h (26) 0.148 x 1 th 2.715 3,175 2,335 2,730 HTU210 51-671h (32) 0.162 x 3 h (22) 0.148 x 1'h 2.005 3,040 1.725 2,615 < 51 (20) 0.162 x 3'h (14) 0.148 x 3 1,335 2-555 1.145 2,200 HTU26-2 51-671h (2010]62 x 3'h (12) 0.148 x 3 1,110 2.700 955 2,320 < 51 (26) 0.162 x 31h (20) 0A48 x 3 2.470 3 890 2.120 3.345 HTU28-2 51-671h (26) 0.162 x 31h (17) 0.148 x 3 1,710 3.775 1,470 3,245 < 51 T (32) 0.162 x 3'h (26) 0.148 x 3 3,600 4 935 3.100 4.245 HTU210-2 51-671h (32) 0162 x 3 h (22) 0.148 x 3 1 2,255 4.790 1.940 4,120 1. Uplift bads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 2. Allowable downloads may not be increased. 2. Maximum hanger gap between end of joist (truss) and face of carrying member is 1/8'. 3. Fasteners: Nait dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information "A^ 'Acute flange side Specify angle Top View HTU Hanger Skewed Right < 510 "A„ Specify angle 7 5V to 671/2° Top View HTU Hanger Skewed Right:, 51' Strong -'fie 198 74 Simpson Strong-T;el Wood Construction Connectors Multiple Truss Hip/Jack Hanger The THJU hip/jack hanger offers the most flexibility and ease of installation without sacrificing performance. The U-shaped hanger works for rrght- and left-hand hips and can be ordered to fit a range of hip skews (up to 67'/x°) as well as various single and 2-ply hip/jack combinations. Also can be installed before or after the hip and jack. THJt126 is sized for the standard hip/jack combination with a 45' left- or right hand hip, The wide seat of THJU26-W accommodates a 2-ply hip and 2-ply jack combination with a 45' maximum hip skew, or a standard single ply hiprjack configuration with a maximum 67'/s° hip skew. Intermediate seat widths are available for ether hipjack or hip/hip combinations. Material' 12 gauge Finish: Galvanized installation: • Use all specified fasteners; see General Notes Options: • THJU is available in intermediate seat widths between 51/a" (THJU26 width) and fir/a' (THJU26 W width) with no load reduction, • For double -hip installation, divide the total allowable load by 2 to determine the allowable load for each hip. Order as THJU26X and specify width; see table for reference. • Allowable download and uplift for all intermediate widths is 100% of the THJU26-W table loads. Codes, See p.12 for Code Reference Key Chart THJU26 1'h' -t I':-. 1Yp. work ng point THJU26-W Top View Two -Ply Hip/Two-Ply Jack Installation THJU Intermediate Width Options SIMPSON Strong -Tie Typical THJU26 Installation , N 1W typ. ti working 45° point THJU26 Top View Right -Hand Hip Installation Carried Member Combination Hip Skew Width (W) 2-ply hip and single -ply jack 45' 63A Single -ply hip and 2-ply lack 45° 63', Double (terminal) hip 45' 73f; 2-ply hip and 2-ply jack 45' Use THJU26-W Single -ply hip and single -ply jack 44'— 46' Use THJU26 47`-49' 51/2 50°- 52° 531. 53°- 55' 6 56'- 57° 6% 58°-59° 1 6ya 60°-61° 7 620-63° 1 7-% 64'-65° 1 Use THJU26-IN + W THJU Top View Installation Dimensions (in.) Fasteners (in,) DFlSP Allowable Loads SPFIHF Allowable Loads Model Min. Carried Download Download Code No, Member WTH Carrying Member Hip Jack Uplift (160) Floor Snow Roof Wind Uplift (160)EF Snow Roof Wind Ref. (100) (115) (125) (160) (115) (125) (16D) 2x4 3 (4)0.148x3 (4) 0.148 x 3 780 1,915 1,915 1,915 1.915 670 1,645 1,645 1,6452x6 THJU26 5'!a 5:Y 3'/i(1610.148x or end. vert. (16)0.148x3 (7)0.148x 3 (7) 0.148 x 3 1,310 2,255 2.350 2,350 2.350 1,125 2.020 2.020 2,020 18C THJU26-W 2x4 8'/e 538 31k (16) 0.148 x 3 (4) 0.148 x 3 (4) 0.148 x 3 685 1.825 1,825 1,825 1,825 590 1,570 1,570 1.570 1,570 FL (16) 0.148 x 3 (7) 0.148 x 3 {7) 0.148 x 3 1,240 t,965 1,965 1,965 1.965 1.065 1.690 1.690 1,690 1,690 2x6 ar end. veil? 1. Tabulated loads are the total allowable loads of the hip and jack members combined; 655. 8Yq of the total ladd shall be distributed to the hip member, and the remaining percentage of the total oad shall be distributed to the jack. The combined hip and pack load may not exceed the published total load. 2. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce wtkre other loads govern. 3. For full -oad. the lack requires either a minimum 2x6 bottom chord or a minimum 2x4 end verticat the hip requires either a minimum 2x6 bottom chord or a minimum 2x6 end vertical for hip skews up to 50 For hip skews greater than 60' (THJU26- W onh-i, a minimum 2x6 bottom chord or minimum 2x3 end vertical is required 4. With single 2x carrying members, use 0,148' x 11/2' nails and use t00-c of the table value. 5. For single 2x jacks. 0.148' x 11/2' nails may be substituted for the specified 0.148' x 3- with no reduction in load. 6. Truss chord cross -grain tension may limit ailovrable loadz, in accordance with ANSlrTPI 1.2014, Simpson Strong -Tie' Connector Selector' software includes the evaluation of cross -grain tension in its hanger ailovrable toads. For additional information, contact Simpson Strong -Tie, 7. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21 22 for fastener information.