HomeMy WebLinkAboutRoof information sheet nre �41K
Q ST. LUCIE WORKS
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020) _ �+
Based on Section 1525 of the Florida Building Code-Buildings y� (�4.<rticaay9G�L9 �!
INSTRUCTION PAGE FOR
6 �, � C�
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING S EE3_CC
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
E COPY
Required Sections of Attachments Required
Roof System the Permit Application See List Below
Form
Low Slope Application A, B,C 1284.567
Prescriptive BUR-RAS 150 A, B,C 2,4,5,6,7
Asphaltic Shingles A,B, D 124;587
Concrete or Clay Tile A, B, D, E jt234;567`
Metal Roofs A, B, D 1,2A440,
Wood Shingles and A, B, D tr,_4A67
Shakes
Other As Applicable 1jZ 4J%A.7-
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128
4. Other Component of Product Approval
5. Municipal Permit Application
6. Owners Notification for Roofing Considerations(Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18,2021
ST. LUCIE . .,fY. �
'S
Section A.(General Information)
Master Permit No. ' ^� Process No. � (f
Contractors Name: L� G� _ � � License#
Job Address ,—§-!
w.
ROOF CATEGORY
Low slope 0 Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles
0 Asphaltic Shingles Metal Panel/Shingles OWWood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
-` ROOF ROOF TYPE
fly flew roof 0 Repair 0 Maintenance <Reroofing E3 Recovering
ROOF SYSTEM INFORMATION
Low Slope Roof Area(SF) SW ' ' Steep Sloped Roof Area(SF)_ U U Total(SF)
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets.
r 1 �
p
-tTi 4
i A ,:
_ - J
• H LUCK `i
Sir
Section D(Steep Slope Roof System) ,y
Roof System Manufacturer.
Notice of Acceptance Number:
Minimum Design Wind Pr ssures,If Applicable(From RAS 127 or Calculations);
Zone 1: Zone 2e;7 D Zone 2n done 2r.71-,Zone 3e.�Zone 3r: r
Deck Type: f�f A
Type Undedaayment
Roof Slope:
—J—= t 2 Insulation:
Fire Barrier: /
Ridge Ventilation? Fastener Type&Spacing:
�eS ,
Adhesive Type:
Type Cap Sheet; I.
Mean Roof Height: 513 Roof Covering R,
Type&Sim Drip ��� a2 2
Edge:
Section C(Low Slope Roof) Surfacing:
Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
manufacturer Zone 1'• "oc @ Lap,#Rows 0 'cc
(If a component is not used,identify as"NA") Zone 1• "oc @ Lap,#Rows ® woo
System Manufacturer: ._ � o t°' Zone 2• "oc @ Lap,#Rows @ 'oo
LZ 6 4,4t-� /1 Zone 3• "oc @ Lap,#Rows® moo
Product Approval Nc
Number of Fasteners Per Insulation Board: !
Design Wind Pressures,From RAS 128 Or Calculations: Zone I" Zone 1- Zone 2- Zone 3*
Zone 144 Zone 1:—Ls,o Zone 2: 56Zone 3: . �ZJ Illustrate Components Noted and Details as Applicable:
Max. Design Pressure,from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping,
system: Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing,Coping,Etc..
Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base
Type: `f Woo/ �;44&jz Flashing,Component Material,Material'Thickness,Fastener
Type,Fastener Spacing or Submit Manufacturers Details that
Gauge Thickness: Comply with RAS 111 and Chapter 16..
Slope: Az
Anchor/Base Sheet&No.df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material: FT.
Insulation Base Layer:
Base Insultation Size and Thickness: ` Parapet /vim
Base Insulation Fastener/Bondine Material: Height
Top Insulation Layer:
Top Insulation Size and Thickness: 15 FT.
Top Insulation Fastener/Bonding Material:
Mean
Base Sheet(s)&No.of Ply(s): Roof
Base Sheet Fastener/Bonding Material: Height
Ply Sheet(s)'&No.of Ply(s):._
Ply Sheet Fastener/Bonding Material:
Top Ply: f
Top Ply Fastener/Bonding Material:
ST. LUCIE UVORK
Section E(Tile Calculations)
For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mr.If the Mf values
are greater than or equal to the Mrvalues,for each area of the roof,then the tile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: _( Product ApprovalMi
(Zone 2e x _ _ -1i1 - -.1 Product Approval Mf
(Zone 2n: Product Approval Mf
(Zone 2r: _ X1{ _ Product Approval Mf�-
(Zone 3e: X1 = _) MW =Mei Product Approval Mf
(Zone 3r: M Product Approval Mf -
Method 2"Simplified Tile Calculations Per Table Below"
Required Moment of Resistance(Mr) From Table Below Product Approval Mf
Mr required Moment Resistance*
Mean Roof Height Roof Slope 15' 20' 25' 30' 40'
2:12 34.4 36.5 38.2 39.7 42.2
3:12 32.2 34.4 36.0 37.4 39.8
4:12 30.4 32.2 33.8 35.1 37.3
5:12 28.4 30.1 31.6 32.8 34.9
6:12 26.4 28.0 1 29.4 30.5 32.4
7:12 24.4 25.9 27.1 28.2 30.0
*Must be used in conjunction with a list of moment based the systems
• For Uplift based tile systems use Method 3. Compare the values for F'with the values for Fr,If the F'values are greater than or
equal to the F,values,for each area of the roof,then the tile attachment method is acceptable.
Method 3"Uplift Based Tile Calculations Per RAS 12T
(Zone 1: x L =x W:= )-W: cos r =F,i Product Approval F'
(Zone 2e: x L =x W:= )-W: cos r =Fr2e Product Approval F'
(Zone 2n: x L =x W:= )-W: cos r - =Fr2" Product Approval F'
(Zone 2r: x L =x W:= )-W: cos r =Fr2r Product Approval F'
(Zone 3e: x L =x W:= )-W: cos r =Frae Product Approval F'
(Zone 3r: x L =x W:= )-W: cos r =Far Product Approval F'
Where to Obtain Information
Description Symbol Where to find
From applicable table in RAS 127 or by an engineering analysis
Design Pressure Zones 1,2e,2n,2r,3e,3r prepared by PE based on ASCE 7
Mean Roof Height H Job Site
Roof Slope 8 Job Site
Aerodynamic Multiplier a Product Approval
Restoring Moment due to Gravity Mg Product Approval
Attachment Resistance Mf Product Approval
Required Moment Resistance Mg Calculated
Minimum Attachment Resistance F' Product Approval
Required Uplift Resistance F, Calculated
Average Tile Weight W Product Approval
Tile Dimensions L=length W=width Product Approval
All calculations must be submitted to the building official at the time of permit application.