Loading...
HomeMy WebLinkAboutAPPROVED ROOFINFOST. LUCIE ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,314,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, 8, D, E 1,2,3,4,5,6,7 etal Roofs A, B, D Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1, Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5, Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCIE Section A (General Information) Master Permit No. Process No. Contractors Name: 7ul ce GA/Q License# GGG 1 ?j.323r-I b Job Address de&an -tYi ✓e 46SO ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles ❑Asphaltic Shingles 210 etal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance IEKeroofing ❑ Recovering . ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) 1110 n Total (SF) 1100 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. gOov 2 hz I ST. LUCIE .WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: _Zone 3: Max. Design Pressure, from the specific product app system: Deck: Type: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Mat ial: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_ " oc @ Lap, # Rows— ® _" 00 Zone 1:—" oc @ Lap, # Rows _ ® —" 00 Zone 2:_." oc @ Lap, # Rows — ® —" oo Zone 3:_..." oc @ Lap, # Rows— ® —" 00 Number of Fasteners Per Insulation Board: 1':_Zone 1:_Zone 2--Zone 3:— illustrate omponents Noted and Details as Applicable: ocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashin& Coping, Etc.. dicate: Mean Roof Height, Parapet Height, Height of Base FI ing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. ST. LUCIE Section D (Steep Slope Roof System) Roof System Manufacturer: Dyn C- %�rir u/�Li LyC, Notice of Acceptance Number: 2:7tig9. 2n Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:-�W Zone 2e::L"�'/ Zone 2n:'r� Zone 2r:'�� Zone 3e.'7o� Zone 3r: —t'ZS Deck Type: Roof Slope: Type Underlayment: e an y�� /6 2 12 Insulation: /A Fire Barrier: Ridge Ventilation? Fastener Type & Spacing: I/ i Alba •5 Flm-r s d• Adhesive Type: ✓(/ !� Type Cap Sheet Mean Roof Height: Z� Roof Covering: a 5V Cr;ry Type & Size Drip axa Edge: ST. LUCIE WORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: x 1, (Zone2e: -xA'_= (Zone 2n: —x l—= (Zone2r: —x)6_= (Zone3e: --x)L—= (Zone3r: I)6—= --J-M9:-=Mrl- �—M9�—=M,z,— Product Approval M- Product Approval Mt Product Approval Mr Product Approval Mf Product Approval Mf Product Approval Mf Method 2 "Simplified Tile Calcu attons Per Table Below" Required Moment of Resistance (Mr) From Table Below—EtoAuct Approval Mf Mr required Moperifkestance- Mean Roof Height Roof Slope 15' 0' 25' 30' 40' 2:12 34.4 6.5 38.2 39.7 42.2 3:12 32.2 ' 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 2 .4 E 30.1 31.6 32.8 34.9 6:12 16AIN 28.0 9.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of momell%t,,based tile systems • For Uplift based tile systems use Method 3. Compar the values for F' with the values for Fr If the F' values are greater than or equal to the Fr values, for each area of the roof, then the 'le attachment method is acceptable. Meths 3 "Uplift Based Calculations Per RAS 12T (Zone 1: x L =x W:= ) -W: cos r = Product Approval F' (Zone 2e: x L =x W:= ) -W: cos r =Fa"_ Product Approval F' (Zone 2n: x L =x W:=) -W: cos r =Fr2n_ Product Approval F' (Zone 2r: x L= x W:= ) -W: cos r =Far_ Product Approval F' (Zone 3e: x L =x W:= ) -W: c s r =Fr3e_ Product Approval F' (Zone 3r: x L= x W:= ) -W: cos =Fran_ Product Approval F' Where to Obtai i Information Description Sym Where to find Design Pressure Zones 1, 2 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height Job Site Roof Slope 6 Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Ms Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance F, Calculated Average Tile Weight W Product Approval Tile Dimensions L=length W=width Product Approval All calculations must be submitted to the building official at the time of permit application.