HomeMy WebLinkAboutAPPROVED Underlayment9128/21, 10:16 AM
Florida Building Code Online
Business •ProfessionalRegulation
r
BC1S Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Floricf'
dpr
(APaduct Approval
Ir �-� USER! Public User
Product Aooroval Menu > Product or Aonlication Search > Agobcatian List > Application Detail
FL # FL2569-R22
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON -US 00000
(819)478-2400
memathieu@soprema.ca
Authorized Signature Marc -Etienne Mathieu
memathieu@ soprema.ca
Technical Representative Marc -Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans- Michaud
Drummondville, NON -US 00000
(819)478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative Jean -Francois Cote, Ph.D,
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema,ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nleminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL2569 R22 COI 2021 01 COI NIEMINEN.p_(jf
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D4601 2012
ASTM D4798 2011
FM 4474 2011
FRSA/TRI Sixth Edition 2018
TAS 103 2020
UL1897 2015
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckBl G8Erxl Ud3xYlr7amGvvoArggkU4EylLatg%3d%3d 112
9/28/21, 10:16 AM
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date
Submitted
04/19/2021
Date
Validated
04/19/2021
Date
Pending FBC Approval
04/26/2021
Date
Approved
06/08/2021
Date
Revised
07/29/2021
Summary of Products
r I
FL ft
Model, Number or Name
Description
2569.1
Soprema Roof Undedayments for
Self adhering roof underlayments
use in FBC HVHZ jurisdictions
LlmRs of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL2569 R22 II 2021 04 19 FINAL ER SOPREMA HVHZ FL2569-
B22.Rdf
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verifled By: Robert Nleminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use.
Evaluation Reports
FL2569 R22 AE 2021 04 19 FINAL R SOPREMA IJVHZ FL2569-
P22.gdf
Created by Independent Third Party: Yes
2569.2
Soprema Roof Underlayments for
Self adhering roof underlayments
use In FBC non-HVHZ jurisdictions
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL2569 R22 tI 2021 04 19 FINAL ER SOPREMA NON -
Approved for use outside HVHZ: Yes
HVHZ FL2569-R22.pAf
Impact Resistant: N/A
Verified By: Robert Nleminen, P.E. PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.)
Evaluation Reports
The design pressure noted herein pertains to
FL2569 R22 AE 2021 04 19 FINAL ER SOPREMA NOW
HVHZ FL2569-R22.pdf
underiayment systems used beneath adhesive -set the
systems. Refer to ER Section 5.8.3 for details.
Created by Independent Third Party: Yes
Beck Neat
Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employes Coavtloht 2007-2013 State of Florida.:: Prlyacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to Mls entity. Instead, contact the office by phone or by trachbonal mall. If you have any questions, please rented 850.487.1395. 'Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if May have one. The emalls
provided may be used for oMdal communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide Me Department with an small address which can be made available to Me public. To determine If you are a licensee under Chapter 455, F.S., please click hem.
Product Approval Accepts:
®®® a
Credit Card
Safe
hfps://www.floridabuilding.org/pr/pr_app_del.aspx?param--wGEVXQwtDgsKOFEnckB108Eml Ud3xYlr7amGvvoArggkU4EylLatg%3d / 3d 2/2
N,16
NEMO I etc.
Certificate of Authorization 1132455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATIONE•
Soprema,Inc. Evaluation Report S18010.06.09-R20
1640 rue Haggerty FL2569-R22 (NON-HVHZ)
Drummondville, Qudbec J2C SP8 Canada Date of Issuance: 06/15/2009
(819)478-2400 Revision 20:04/10/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7N Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof Underlayments for use in FBC non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report isvalid until such time asthe named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO] etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8
Prepared by:--
e�+SS�c+2
Robert J.M.Nleminen,P.E.
'•� p�!••= The facsimile seal appearingwas authorized byRobert
Florida Registration No. 5916E Florida OCAANE1983
°•.y' si�a1;. ;o•T Nlemmen,P.E. on 04/19/2021. This does not serve as
=.lSi+••nn�
an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or
distributing products It evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being Issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC, LLC
ONEIVIO etc.
ROOFING COMPONENT EVALUATION:
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement: Soprema Roof Underlayments, as produced by Soprema, have demonstrated compliance
with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use
set forth herein.
STANDARDS:2.
Section
Property
Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1897
2015
1507.1.1, 1507.2.4, 1507.2.9.2
Material standard
ASTM D1970
2015
/ R905.1.1, R905.2.8.2
1507.3.3 / R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
TA5110
Accelerated Weathering
ASTM D4798
2011
Entift
Examination
Reference
Date
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
FRSA/TRI 04-12 (MS)
S43530.02.14-1-R1
02/21/2014
ERD (TST6049)
ASTM D1970(QC)
S44870.04.14-3
04/02/2014
ERD(TST6D49)
ASTM D1970 (OH)
S44870.04.14-1
04/10/2014
ERD (TST6049)
ASTM D1970 (MS)
S44870.04.14-4
04/10/2014
ERD (TST6049)
ASTM D1970 (OH)
S40540.10.14
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SC8520.04.14
04/27/2015
ERD (TST6049)
Wind Resistance
SOPC-SC14045.05.17-RS
06/07/2017
NEMO (TST6049)
ASTM D1970 / TAS 110 (QC)
SOPC-SC8970.08.15-R1
04/25/2018
NEMO (TST6049)
Wind Resistance
4-SOPC-18-003.08.18
08/27/2018
NEMO (TST6049)
Tile Slippage
4S-SOPC-18-002.09.18
09/21/2018
NEMO (TST6049)
ASTM D4798/D1970 (OH & MS)
4S-SOPC-18-002.05.19.A
05/31/2019
NEMO (TST6049)
Tensile Adhesion / Long Term Aging
4p-DOW-I9-SSLAP-OI.A.R2
02/10/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-I9-SSUDL-04.A
03/12/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4J-SOPC-20-SSUDL-01.A
01/07/2021
NEMO (TST6049)
ASTM D1970 (MS)
4j-SOPC-2I-SSUDL-01.A
04/19/2021
PRI(TST5878)
ASTM D1970 (MS)
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R16814
12/10/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R27605
05/08/2019
UL, LLC (QUA9625)
Quality Control
Service Confirmation
06/29/2020
UL, LLC (QUA9625)
Quality Control
Florida BCIS
Current
C
4.1
4.2
PRODUCT
Product
Material
Standard
Platt(s)
Description
LASTOBOND TU HT
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric
FRSA/TRI 09-18
surfaced, SBS modified bitumen roof
underlayment
Tri-Built S/A HT TU
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric
Underlayment
FRSAITRI 09-18
surfaced, SBS modified bitumen roof
underlayment
NEMO ETC, LLC Evaluation Report S18010.06.09420
Certificate of Authorization a32455 7- EDITION (2020) F8C NON-HVHZ EVALUATION FLZS69-RZZ(NON-NVHZ(
Soprema Roof Underlayments Revision 20: 04/19/2021
Page 2 of 8
4.3
4.4
4.5
4.6
4.7
7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
4.17
ONEMOletc.
Product
Material
Plant(s)
Description
Standard
LASTOBOND Shield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
RESISTO SA SMOOTH PLY
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
40
modified bitumen roof underlayment
LASTOBOND Shield HT
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
LASTOBOND Pro HT-N
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
LASTOBOND Pro HT-S
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
EnviroShield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
LASTOBOND Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
LASTOBOND Smooth
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
Seal HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
Tri-Built Smooth HT S/A
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film-
Underlayment
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
PrimeSource Grip -Rite
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
Smooth Seal HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
RESISTO LB1236
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
TRI-BUILT Sand-R SA
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Shingle Underlayment
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
PrimeSource Grip -Rite
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand-
Eave & Valley Protector
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
SRS TopShield ICE &
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
WATER DEFENDER
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
RESISTO LB1244
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
NEMO ETC, LLC Evaluation Report S18030.06.09-R20
Cerffft to o)Authod atlon #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL256"22(NON-HVHZ)
Soprema Roof Underlayments Revision 20: 04/19/2021
Page 3 of 8
ONEMOletc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report Is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBCSecdon:
1507.2
1507.3
1507.4 & 1507.5
1507.7
1SO7.8 & J501.9
Clay and Concrete Tile
Metal
Slate or
Underlayment
Asphalt
Slate -Type
Wood Shakes or
Mechanical
Adhesive-
Shingles
Attach
Set
Panels
Shingles
Shingles
Shingles
LASTOBOND TU HT, Tn-Built S/A HT TU
Yes
Yes
Underlayment
Yes
Yes
See 5.6.1
Yes
Yes
Yes
point SVlps. 3501.LL3/
R9U5.1.1.3)
LASTOBOND Shield, Pro HT-N, RESISTO
Yes
SA SMOOTH PLY 40
Yes
No
No
Yes
Yes
Yes
palm sMRs, ]sm.1.1.3/
R905.1.1.3)
Yes
LASTOBOND Shield HT, Pro HT-S
Yes
No
No
Yes
Yes
Yes
pnimmio:, 1507.1.1.3/
R .11.3)
Yes
EnviroShield
Yes
No
No
Yes
Yes
Yes
polmmnR:, 1907.1.1.3/
R905.1.1.3)
LASTOBOND ECO, RESISTO LB1236, TRI-
BUILT Sand-R SA Shingle Underlayment,
Yes
Grip -Rite Eave & Valley Protector,
Yes
No
No
No
No
Yes
aolm WIN, M7.11.3/
TopShield ICE & WATER DEFENDER,
R99s.1.1.31
RESISTO LB1244
LASTOBOND Smooth Seal HT, Tri-Built
Yes
Smooth HT S/A Underlayment, Grip -Rite
Yes
No
No
Yes
Yes
Yes
1
pant mlp:, M7.L1.3/
Smooth Seal HT
11905.1.1.3)
5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment / tile -adhesive combinations.
TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS'
Underlayment
Adhesive
Florida Product Approval
LASTOBOND TU HT, TN -Built S/A
HT TU Underlayment
Dupont Mle Bond"' Roof Tile Adhesive"
FL22525
ICP Adhesives and Sealants "Polysete AH-160"
FL6332
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance
NEMO ETC, LLC Evaluation Report S18010.06.09-R20
Cerriicate ofAuthorizatkx, a32455 7n'EDITION (2D201 FBC NON41VHZ EVALUATION FL2569-RZZ(NON-HVHZ)
Soprema Roof Undedaymerds Revision 20: 04/19/2021
Page 4 of 8
NNIEMOjetc.
5.7 Allowable Substrates:
TABU: 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates (designed to meet wind loads for project)
Underlayment
Application
Type Primer Material(s)
LASTOBOND Shield, LASTOBOND Pro HT-
(Optional) ASTM
plywood, OSB or Southern Yellow
N, RESISTO SA SMOOTH PLY 40,
Deck/
D41, Elastocol Stick,
Pine (SYP)
LASTOBOND Shield HT, LASTOBOND Pro
sheathing
Elastocol Stick Zero
HT-S, EnviroShield, LASTOBOND TU HT,
ASTM D41
structural concrete
Tri-Built S/A HT TU Underlayment,
(Optional) Elastocol
Dens Deck Prime or SECUROCK
LASTOBOND ECO, RESISTO L¢1236, TRI-
self-
Insulation
Stick Zero
Gypsum -Fiber Roof Board
BUILT Sand-R SA Shingle Underlayment,
adhering
Grip -Rite Eave & Valley Protector,
TopShield ICE & WATER DEFENDER,
RESISTO L81244, LASTOBOND Smooth
Base Sheet
(Optional) Elastocol
ASTM D226, Type II felt or
Seal HT, Tri-Built Smooth HT S/A
Stick Zero
Modified Sopra-G
Underlayment or Grip -Rite Smooth Seal
HT
LASTOBOND TU HT, Tri-Built S/A HT TU
Underlayment, RESISTO LB1236, TRI-
self-
Existing
RESISTO EXTERIORadhering
Existing sand -surfaced, glass -fiber
BUILT Sand•R SA Shingle Underlayment,
substrate
PRIMER
surfaced, mineral -surfaced orfllm-
Grip-Rite Eave & Valley Protector or
surfaced roof underlayment*
TopShield ICE & WATER DEFENDER
• Final acceptance of any existing substrate in a renoof (tear -off) installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive LASTOBOND TU HT, Tri-Built S/A HT
TU Underlayment RESISTO LB1236, TRI-BUILT Sand -RSA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE &
WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the
self -adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be In accordance with the manufacturer's installation
instructions, but —for mechanically attached base sheets - not less than Section 5.8.3 herein.
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table IA or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
NEMO ETC, LUC Evaluation Report S38030.06.09-RZO
Certpiccte ufAuthorkotion 432455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FUS69-RZZ(NON-HVNZ)
Soprema Roof Underlayments Revision 20:04/19/2021
Page S of 8
ONEMOletc.
#1 Maximum Design Pressure =-45.0 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self -adhered and back -nailed within the
selvedge -edge side laps using 12 ga. x W ring shank nails through 32 ga., 1-5/8" diameter tin caps
spaced 12-Inch o.c..
#2 Maximum Design Pressure=-67.S osf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self -adhered and back -nailed within the
selvedge -edge side laps using 12 ga. x W ring shank nails through 32 ga., 1-5/8" diameter tin caps
spaced 12-inch o.c..
#3 Maximum Design Pressure =-120.Oasf:
Deck: Min. 15/32-Inch APA-rated COX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered.
Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self -adhered and back -nailed within the
selvedge -edge side laps using 12 ga. x W ring shank nails through 32 ga., 1-5/8" diameter tin caps
spaced 12-inch o.c..
#4 Maximum Design Pressure = -150.0 psf:
Deck: Min. 15/32-Inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self -adhered and back -nailed within the
selvedge -edge side laps using 12 ga. x W ring shank nails through 32 ga., 1-5/8" diameter tin caps
spaced 12-inch o.c..
#5 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of -45 psf.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 2609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29, Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk' carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Design Pressure = -60.0 osf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails (FBC 1517.5.1).and tin caps (FBC 1517.5.2) spaced 6-
Inch o.c. at the flinch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet.
Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self -adhered and back -nailed within the
selvedge -edge side laps using 12 ga. x W ring shank nails through 32 ga., 1-5/8" diameter tin caps
spaced 12-Inch o.c.
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in accordance with the manufacturer's installation Instructions and attachment of the
Insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
NEMO ETC, LUC Evaluation Report 518030.06.09-11120
Certif/cate of Authorization 032455 7- EDITION (2020) EPIC NON-HVHZ EVALUATION FLZ569-R22 (NON-HVHZ)
Soprema Roof Underlayments Revision 20: 04/19/2022
Page 6 of 8
ONEIVIOletc.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Prepared Roof Cover
Maximum
Installation Type
Exposure (days)
LASTOBOND Eco, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment,
Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO
Mechanically attached
30
LB1244
LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40,
LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND Smooth
Mechanically attached
90
Seal HT, Tri-Built Smooth HT 5/A Underlayment or Grip -Rite Smooth Seal HT
Mechanically attached or
LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment
adhesive -set the roof
180
system
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRER -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
LASTOBOND TU HT, Tri-
Built S/A HT TU
Underlayment
Lugged
Double -tile stacking method, as shown below 6:12
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.2.1 Installation of RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or
TopShield ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE
& WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
NEMO ETC, LLC Evaluation Report 518010.06.09-R20
Cerrilwre of Authorization 432455 7- EDITION(2020) FBC NON41VHZ EVALUATION FL2569-RZZ(NON-HVHZ)
Soprema Roof Undedaymems Revision 20: 04/19/2021
Page 7 of 8
NEMO I etc.
6.3 LASTOBOND TU HT, Tri-Built S/A HTTU Underlayment, LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA
SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND Eco, LASTOBOND
Smooth Seal HT, Tri-Built Smooth HT 5/A Underlayment, Grip -Rite Smooth Seal HT, RESISTO LB3236, TRI-BUILT
Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or
RESISTO LB1244:
V.J.l 11UII-I IIV HuuM-auUtu[
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.2 or R905.1.1.
6.3.2 Tile Applications:
Limited to LASTOBOND TU HT or Tri-Built S/A HTTU Underlayment.
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
BUILDING7.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
S. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 518910.06.09-R20
Certijlcate of AVthanrotian #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION F12569-R22 (NON-HVHZ)
5oprema Roof Underlayments Revision 20: 04/19/2021
Page 8 of 8