HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name. WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CORP. Jurisdiction:
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing New (From Playas)
10. Wall Types(1718.3 sqft.) Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent R=11.0 240.00 ftz
c NIA R= ftz
4. Number of Bedrooms 1
d. N/A R= ft2
5. Is this a worst case? Yes
11. Ceiling Types(1336.0 sqft.) Insulation Area
6. Conditioned floor area above grade (ft2) 1306
a. Under Attic (Vented) R=30.0 1306.00 ft2b.
Conditioned floor area below grade (ft2) 0
Knee Wall (Vented) R=19.0 30.00 ft2
c NSA R= ftz
7. Windows(128.9 sqft.) Description Area
12. Ducts, location & insulation level R ftZ
a. U-Factor. Sgl, U=1.02 76.04 ftz
a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120
SHGC: SHGC=0.29
b.
b. U-Factor: Sgi, U=1.03 40.00 ftZ
C.
SHGC: SHGC=0.27
13. Cooling Systems kBtu/hr Efficiency
c. U-Factor: Sgl, U=1.02 12.85 ftz
a. Central Unit 29.0 SEER:14.00
SHGC: SHGC=0.26
Area Weighted Average Overhang Depth: 4.701 ft
Area Weighted Average SHGC: 0.281
14. Heating Systems kStu/hr Efficiency
8. Skylights Description Area
a. Electric Heat Pump 27.0 HSPF:8.20
U-Factor:(AVG) N/A N/A ftZ
SHGC(AVG): NIA
9. Floor Types Insulation Area
15. Hot Water Systems
2
a. Slab -On -Grade Edge insulation R= 0.0 1306.00 ft2
a. Electriciankless Capgallons
: i gall ons
R=s
EF: 0. 600
c. NIA
b. Conservation features
None
16. Credits None
Glass/Floor Area: 0.099 Total Proposed Modified
Loads: 41.30
Total Baseline
Loads: 43.21 PASS
I hereby certify that the plans and specifications covered by
Review of the plans and 1,11
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed`
0
6-7-2021
this building will be inspected for
DATE:
compliance with Section 553.908
Florida Statutes. *'
hereby certify that this building, as designed, is in compliance
~
Q�l)WF
with the Florida Energy Code:
OWNER/AM.- ____._ _. _ ..
BUILDING OFFICIAL:
DATE:
DATE:
- %,Wnpnance requires cerurncavon oy me air nanwer unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 Qn for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
6I712021 11:47:00 AM EnergyGauge@ USA 7.0.00 - RaRes2020 FBC 7th Edition (2020) Compliant Software Page I
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE BUILLING-THE COTTAGE IMPACT
Addresstype:
Street Address
Building Type: User
Bedrooms: 1
Lot#:
-
Owner: WYNNE BUILDING CORP.
Conditioned Area: 1306
Block/SubDMsion: -
Total Stories: 1
PlatBook:
-
Builder Name: WYNNE BUILDING CORP.
Worst Case: Yes
Street
THE COTTAGE
Permit Office: ST. LUCIE COUNTY
Rotate Angle: 180
County:
St. Lucie
Jurisdiction:
Cross Ventilation: No
City, State, Zip:
FT. PIERCE,
Family Type: Detached
Whole House Fan: No
FL,
New/Existing: New (From Plans)
Terrain: Suburban
YearConstruct:
Shielding: Suburban
Comment:
CLIMATE
Design
Design Temp
Int Design Temp
Heating
Design
Daily temp
Location
Tray Site
97.5% 2.5%
Winter Summer
Degree Days
Moisture
Range
_ FL, Fort Pierce
FL_VERO_BEACH_MUNICIPA 39 90
70 75
299
62
Low
BLOCKS
Number Name
Area
Volume
1 Entire House
13M76.2001953125
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
Finished
Cooled
Heated
_ 1 MASTER BEDROOM
234
1895.4 No 0
1
Yes
Yes
Yes
_2 DEN
144
1166.4 No 0
Yes
Yes
Yes
_3 SINK AREA
42
340.2 No 0
Yes
Yes
Yes
_4 CLOSET
63
510.3 No 0
No
Yes
Yes
_5 GREAT ROOM
452
36612 No 2
Yes
Yes
Yes
_6 MASTER BATH
50
405 No 0
Yes
Yes
Yes
_7 POWDER
25
202.5 No 0
No
Yes
Yes
_8 KITCHEN
232
1879.2 Yes 0
Yes
Yes
Yes
_9 LAUNDRY
40
324 No 0
No
Yes
Yes
_10 STORAGE
24
192 No 0
0
Yes
Yes
Yes
FLOORS
(Total Exposed Area = 1306 sq.ft.)
# Floor Type
Space
Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value
Tile Wood Carpet
_ 1 Slab -On -Grade Edge Ins
MASTER BEDROOM 31 0
234 ft 0.473
-
0.00
1.00 0.00
-2 Slab -On -Grade Edge Ins
DEN
24 0
144 ft 0.473
-
0.00
1.00 0.00
_ 3 Slab -On -Grade Edge Ins
SINK AREA
7 0
42 ft 0.473
-
0.00
1.00 0.00
_ 4 Slab -On -Grade Edge Ins
CLOSET
1 0
63 ft 0.473
-
0.00
1.00 0.00
_ 5 Slab -On -Grade Edge Ins
GREAT ROOM
32 0
452 ft OA73
-
0.00
1.00 0.00
_6 Slab -On -Grade Edge Ins
MASTER BATH
5 0
50 ft 0.473
-
0.00
1.00 0.00
_7 Slab -On -Grade Edge Ins
POWDER
- 1 0
25ft 0.473
-
0.00
1.00 0.00
_ 8 Slab -On -Grade Edge Ins
KITCHEN
38 0
232 ft 0.473
-
0.00
1.00 0.00
9 Slab -On -Grade Edge Ins
LAUNDRY
1 0
40 It 0.473
-
0.00
1.00 0.00
10 Slab -On -Grade Edge Ins
STORAGE
21 0
24 It 0.304
-
0.00
0.00 1.00
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
ROOF
/
Roof Gable Roof
Red
Solar SA
Emitt Emitt
Deck Pitch
V# Type
Materials Area Area Color
Barr Absor. Tested
Tested
Insul. (deg)
1 Hip
Metal 1376 T 0 ft' Light
N
0.6 No
0.9 No
0 18.4
ATTIC
# Type
Ventilation Vent Ratio (1 in) Area
RBS IRCC
1 Fullattic
Vented 150 1306 ft2
N
N
CEILING
(Total Exposed Area = 1336 sq.ft.)
# CeilingType
Space R-Value Ins.Type
Area
U-Factor Framing Free.
Truss Type
_ 1 UnderAttic(Vented)
MASTER BEDROOM 30.0 Blown
234.0ft2
0.053
0.10
Wood
_2 UnderAttic(Vented)
DEN 30.0 Blown
144.Oft-
0.053
0.10
Wood
_3 UnderAttic(Vented)
SINK AREA 30.0 Blown
42.011'
0.053
0.10
Wood
_4 UnderAttic(Vented)
CLOSET 30.0 Blown
63.Oft-
0.053
0.10
Wood
_5 UnderAttic(Vented)
GREAT ROOM 30.0 Blown
452.0ft'
0.053
0.10
Wood
_6 UnderAttic(Vented)
MASTER BATH 30.0 Blown
50.0ft
0.053
0.10
Wood
_7 UnderAttic(Vented)
POWDER 30.0 Blown
25.011'
0.053
0.10
Wood
_8 UnderAttic(Vented)
KITCHEN 30.0 Blown
232.0ft'
0.053
0.10
Wood
_9 UnderAtic(Vented)
LAUNDRY 30.0 Blown
40.oft'
0.053
0.10
Wood
_ 10 UnderAttic(Vented)
STORAGE 30.0 Blown
24.0ft'
0.030
0.11
Wood
11 Knee Wall(Vented)
GREAT ROOM 19.0 Blown
30.Oft'
0.045
0.11
Wood
WALLS
(Total Exposed Area = 1718 sq.ft.)
Note: First wall orientation below is as entered. Actual orientation is modified by the rotate angle
(180 degrees) as shown in the "Project" section on page 1.
VAdjacent
Cavity Width
Height
Area U-
Sheath Fnn.
Solar Below
�/ # Omt To
Wall Type
Space R-Value Ft In
Ft In
sq.ft. Factor
R-Value Free.
Absor. Grade
1 S=>N Exterior
Cone. Blk- Int Ins
MASTER BEDROOM 4.1 18.0 0
8.0 1
145.5 0.149
0 0
0.30 0%
_2 W=>E Exterior
Cone. Blk- Int Ins
MASTER BEDROOM 4.1 13.0 0
8.0 1
105.1 0.149
0 0
0.30 0%
_3 N=>S Exterior
Cone. Blk -Int Ins
DEN 4.1 12.0 0
8.0 1
97.0 0.149
0 0
0.30 0%
_4 W=>E Exterior
Cone. Blk -Int Ins
DEN 4.1 12.0 0
8.0 1
97.0 0.149
0 0
0.30 0%
5 S=>N Exterior
Cone. Blk- Int Ins
SINK AREA 4.1 7.0 0
8.0 1
56.6 0.149
0 0
0.30 0%
_6 N=>S Exterior
Cone. Blk - Int Ins
GREAT ROOM 4.1 22.0 0
8.0 1
177.8 0.149
0 0
0.30 0%
_ 7 W=>E Exterior
Cone. Blk - Int Ins
GREAT ROOM 4.1 10.0 0
8.0 1
80.8 0.149
0 0
0.30 0%
8 S=>N Exterior
Cone. Blk - Int Ins
MASTER BATH 4.1 5.0 0
8.0 1
40.4 0.149
0 0
0.30 0%
_9 N=>S Exterior
Cone. Blk -Int Ins
KITCHEN 4.1 17.0 0
8.0 1
137.4 0.149
0 0
0.30 0%
10 E=>W Exterior
Cone. Blk - Int Ins
KITCHEN 4.1 16.0 0
8.0 1
129.3 0.149
0 0
0.30 0%
_ 11 S=>N Exterior
Cone. Blk- Int Ins
KITCHEN 4.1 5.0 0
8.0 1
40.4 0.149
0 0
0.30 0%
_12 N=>S Exterior
Cone. Blk -Int Ins
KITCHEN 4.1 35.0 0
8.0 1
282.9 0.149
0 0
0.30 0%
13 N=>S Exterior
Cone. Blk - Int Ins
STORAGE 4.1 6.0 0
8.0 0
48.0 0.149
0 0
0.30 0%
_ 14 N=>S Exterior
Cone. Blk- Int Ins
STORAGE 4.1 5.0 0
8.0 0
40.0 0.149
0 0
0.30 0%
_ 15 N=>S Garage
Frame - Wood
MASTER BEDROOM 11.0 30.0 0
8.0 0
240.0 0.092
0 0.23
0.30 0%
DOORS
(Total Exposed Area = 20 sq.ft.)
Width
Height
# Omt Adjacent To
Door Type
Space Storms
U-Value
Ft In
Ft In
Area
_ 1 E=>W
Insulated
KITCHEN None
0.32
3.00 0
6.00 8
20.0ft'
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
(Total Exposed Area = 129 sq.ft.)
/ Wall
-Overhang-
/ # Omt ID Frame
Panes
NFRC U-Factor SHGC Imp Storm Area
Depth Separation Interior Shade
Screening
_ 1 W=>E 2 Metal
Low-E Single
Yes 1.02
0.29 N N 32.4ft'
1.0 It 5 in 1.0 ft 5 in None
None
_ 2 W=>E 4 Metal
Low-E Single
Yes 1.02
0.29 N N 18.4fi-
1.0 ft 5 in 1.0 ft 5 in None
None
_ 3 N=>S 6 Metal
Low-E Single
Yes 1.02
029 N N 18.4fP
1.0 ft 5 in 1.0 ft 5 in None
None
-4 W=>E 7 Metal
Low-E Single
Yes 1.03
0.27 N N 40.Oft2
12.0 ft 0 in 1.0 ft 5 in None
None
-5 S=>N 8 Metal
Low-E Single
Yes 1.02
0.29 N N 6.911'
1.0 ft 5 in 1.0 ft 5 in None
None
6 E=>W 10 Metal
Low-E Single
Yes 1.02
0.26 N N 12.8ft-
1.0 ft5 in 1.0 ft5 in None
None
INFILTRATION
# Scope Method
SLA CFM50 ELA EgLA
ACH ACH50 Spaoe(s)
1 Wholehouse Proposed ACH(50)
0.00026
881 48.35 90.78 0.0907 5.0 All
GARAGE
# Floor Area
Roof Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
-1 280 ft2
280 ft2
35 It
8 ft 11
MASS
# Mass Type
Area
Thickness FumitureFrection Space
_ 1 Default(8lbs/sq.fL)
0 ft2
0 ft
0.30 MASTER BEDROOM
_2 Default(81bs/sq.ft.)
0 ft2
0 ft
0.30 DEN
_3 Default(8lbs/sq.fL)
0ft2
Oft
0.30 SINK AREA
_4 Default(8lbs/sq.ft.)
0ft2
Oft
0.30 CLOSET
-5 Defaulg8lbs/sq.ft.)
0 W
0 ft
0.30 GREAT ROOM
_ 6 Default(8lbs/sq.ft.)
0 ft2
0 ft
0.30 MASTER BATH
_7 Default(8lbs/sq.ft.)
0ft2
0it
0.30 POWDER
_8 Default(8 lbs/sq.ft.)
0ft2
Oft
0.30 KITCHEN
_9 Defaulg8lbs/sq.ft.)
0 ftZ
Oft
0.30 LAUNDRY
-10 Default(81bs/sq.ft.)
0 ft2
0 ft
0.30 STORAGE
HEATING SYSTEM
# System Type
Subtype/Speed
AHRI# Efficiency Capacity -GeothermalHeatPump-- Ducts
Block
kBtu/hr Entry Power Volt Current
_ 1 Electric Heat Pump
Split(Single
HSPF: 8.20 27.0
0.00 0.00 0.00 sys#1
1
COOLING SYSTEM
# System Type
Subtype/Speed
AHRI# Efficiency Capacity Air Flow SHR Duct
Block
kBtuthr ofm
-1 Central Unit
Split/Single
SEER:14.0 29.0
0 0.80 sys#1
1
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
Subtype
Location
EF(UEF) Cap Use
SetPnt
Fbdure Flow Pipe Ins.
Pipelength
_ 1 Electric
Tankless
Garage
0.60 (0.60) 1.00 gal 61 gal
120 deg
Standard
None
82
Recirculation
Recirc Control
Loop Branch Pump DWHR
Facilities Equal
DWHR
OtherCredits
System
Type
length length power
Connected Flow
Eff
1 No
NA NA NA No
NA
NA
NA
None
DUCTS
VDuct Supply—
—#
—Retum—
Air
CFM 25 CFM 25
HVAC #
Location
R-Value
Area Location R-Value Area Leakage Type
Handler
TOT OUT
QN
RLF Heat Cool
1 Attic
6.0 120 ft Attic
6.0 45 IF DefaultLeakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans: N
Cooling [ ] Jan
[] Feb
[] Mar
[I Apr
[ ] May [X] Jun [X] Jul
[X] Aug
[X] Sep [ ] Oct
[ ]
Nov I] Dec
Heating [X] Jan
[X] Feb
[X] Mar
[] Apr
[] May [] Jun [] Jul
[] Aug
[ ] Sep [] Oct
Nov [X] Dec
Venting [ ] Jan
[] Feb
[X] Mar
[X] Apr
[ ] May [ ] Jun [] JuIX]
[]Aug[ 1 Aug
[ ] Sep [Xl Oct
[X]
Nov [ ]Dec
VThermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3 4 5 6
7
8 g
10
11 12
_ Cooling (WD)
AM
PM
78
78
78
78
78 78 78 78
78 78 78 78
78
78
78 78
78
78
78 78
78
78
78 78
_ Cooling (WEH)
AM
PM
78
78
78
78
78 78 78 78
78 78 78 78
78
78 78
78
78 78
78
78 78
78
78 78
_Heating(WD)
AM
PM
68
68
68
68
68 68 68 68
68 68 68 68
68
68
68 68
68
68 68
68 68
68
68 68
_Heating(WEH)
AM
PM
68
68
68
68
68 68 68 68
68 68 68 68
68
68
68 68
68
68 68
68 68
68
68 68
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRe52020 FBC 7th Edition (2020) Compliant Software Page 5
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner. WYNNE BUILDING CORP. Jurisdiction: v
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barriershall beinstalled in the building envelope.
Air-perrneableinsulationshall
requirements
The exterior thermal envelope contains a continuous airbarder.
not be used as a sealing material.
Breaks orjoints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per
Knee walls shall be sealed.
inch minimum
Exterior thermal envelope insulation forframed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloordeckin ,or floor g cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawlspacewalls
Exposed earth in unvented crawl spaces shall be covered
Where provided instead alfloor insulation, insulation
with a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garageseparation
Air sealing shall be provided between the garage and
conditionedspaces.
Recessedlighting
Recessed lightfxdures installed in the building thermal
Recessed lightfixtures installed in the building
envelope shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
-
and plumbing in exterior walls, or insulation that on
installation readily conformsto available space shall
extend behind piping and wiring.
Showeritub
The air barrier installed at exterior walls adjacent to showers
Exterior walls adjacent to showers and tubs shall
onextenorwall
and tubs shall separate them from the showers andtubs.
beinsulated.
Electrical/phonebox
The air barrier shall be installed behind electrical or
onexteriorwalls
communication boxes or air -sealed boxes shall be installed.
HVAC register boot
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering
or ceiling penetrated by the boot
Concealed
When required to be sealed, concealed fire sprinklers shall only
sprinklers
be sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
voids between fire sprinkler cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft2)
Conditioned floor area below grade (ft2)
7. Windows" Description
a. U-Factor Sgl, U=1.02
SHGC: SHGC=0.29
b. U-Factor. Sgl, U=1.03
SHGC: SHGC=0.27
c. U-Factor. Sgi, U=1.02
SHGC: SHGC=0.26
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
U-Factor(AVG) N/A
SHGC(AVG): N/A
THE COTTAGE,FT. PIERCE,FL,
New (From Plans)
Detached
1
1
Yes
1306
0
Area
76.04 ft2
40.00 ft2
12.85 ft2
4.701 ft
0.281
Area
N/A ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R= 0.0 1306.00 ft2
b. N/A R= ft2
c. N/A R= ft2
10.
Wall Types(1718.3 sqft.)
Insulation
Area
a. Concrete Block - Int Insul, ExteriorR=4.1
1478.30 ft2
b. Frame - Wood, Adjacent
R=11.0
240.00 ft2
c. N/A
R=
ft2
d. N/A
R=
ft2
11.
Ceiling Types(1336.0 sgft.)
Insulation
Area
a. Under Attic (Vented)
R=30.0
1306.00 ft2
b. Knee Wall (Vented)
R=19.0
30.00 ft2
c. N/A
R=
ft2
12.
Ducts, location & insulation level
R ft2
a. a. Sup: Attic, Ret: Attic, AH: Attic
6 120
b.
C.
13.
Cooling Systems
kBtu/hr
Efficiency
a. Central Unit
29.0 SEER:14.00
14.
Heating Systems
kBtu/hr
Efficiency
a. Electric Heat Pump
27.0
HSPF:8.20
15. Hot Water Systems
a. ElectricTankless Cap: 1 gallons
EF: 0.600
b. Conservation features
None
16. Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: THE COTTAGE City/FL Zip:
'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for
energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff.
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
677/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
wrightsoft® Project Summary o:
Entire House BY
QUICK CALCS, INC.
317ST. LUCIE LANE, FORTPIERCE,FL34946 PInre:772-466-6799 Email: OUICKCALCS@AOL.COM
For: WYNNE BUILDING CORP.
THE COTTAGE, FT. PIERCE, FL
Notes:
Design Information
Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42 OF
Inside db 70 OF
Outside db
Inside db
90
F
Design TD 28 OF
Design TD
75
15 OF
Daily range
M
Relative humidity
50 %
Moisture difference
61 grAb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 16327 Btuh
Ducts
Structure
15522 Btuh
4013 Btuh
Central vent (0 cfm) 0 Btuh
Duds
Central vent (0 cfm)
5251 Btuh
0 Btuh
(none)
Humidification 0 Btuh
(none)
Blower
0 Btuh
Piping 0 Btuh
Equipment load 20340 Btuh
Use manufacturer's data
n
Infiltration
Rate/swingg multiplier
Equipment load
0.95
sensible
19734 Btuh
Method Simplified
Construction quality Average
Latent Cooling Equipment Load Sizing
Fireplaces 0
Structure
2094 Btuh
Ducts
1524 Btuh
Central vent (0 cfm)
0 Btuh
Heatingg Coolingg
Area(fl2) 1306 1306
(none)
Equipment latent load
3618 Btuh
volume (fla) 10579 10579
Air changes/hour 0.45 023
Equiv.AVF(dm) 79
Equipment Total Load (Sen+Lat)
23352 Bluh
41
Req. total capacity at 0.70 SHR
2.3 ton
Heating Equipment Summary
Cooling Equipment Summary
Make Carrier
Trade CARRIER
Make Carver
Trade CARRIER
Model CH14NBO3000GOA0
Cond CH14NBO3000GOA0
AHRI ref 9162387
Coil FX4DNBO43L
Efficiency 8.2 HSPF
AHRI ref 9162387
Efficiency 11.5 EER,14
SEER
Heating input
Heating output 28000 Btuh@470F
Sensiblecooling
Latentcooling
20300 Btuh
8700 Btuh
Temperature rise 26 OF
Actual airflow 967 c6n
Total cooling
Actual
29000 Btuh
Airflowfactor 0.048 cfm/Btuh
Static pressure 0.50 in H2O
airflow
Airflowfactor
Static
967 drn
0.047 cimBtuh
Space thermostat
pressure
Load sensible heat ratio
0.50 in H2O
0.85
Capacity balance point = 34 OF
Backup:
Input=5kW, Output=18005Btuh,100AFUE
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
c wri•gtfY64tC wgft_Suk�Uriversal201919.021 RSU08101 2021-Jarv121321:40
fRC•8K...\Whgftvft /AQWYNNESUIDLING-hiECOTTAGE.np CaIc=MJ8 FrortDoortms SW Pagel
wrightswr RighWO Worksheet Job:
Entire House Date:
QUICK CALCS, INC. sy,
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466-6799 Email: QUICKCALCS ,AOL.COM
1
Room name
Entire Ho
MASTER BEDROOM
2
EVosadwall
145.0 ft
31.0 ft
3
Room height
8.1 ft
8.1 ft heaVwol
4
Room dimensions
13A x 18.0 ft
5
.Room area
1306.0 IF
234.0 f'
Ty
Construction
U-value
Or
HTM
Araa (ft')
Load
Area (�
Load
number
(Bluh4R°F)
(BIUW
or perimeter (127
(Bluh)
or penmeter (ft)
(Btuh)
Heat
Cool
Gros;
N/P/SHeat
Cool
Gross
N/PYS
Heat
Cool
6
y/
13A-4=
0.143
n
4.00
2.19
446
1710
934
0
0 0
0
�G
2glaang,droutr,
1.040
n
29.12
21.68
18
537
400
0
0 0
0
IN
13A4=
0.143
a
4.00
2.19
162
516
282
0 0
0
0
I —DC
2glaang,tlroutr,
1.040
a
29.12
39.42
13
368
498
0
0
0
0
17
1100
0.390
a
10.92
10,34
20
223
211
0
0
0
0
W
13A4=
0.143
s
4.00
2.19
284
1107
605
146
146
584
319
--G
2glaang,droutr,
1.040
s
29.12
21.68
7
202
150
0
0
0
0
13A4as
0.1431
w
4.00
2.19
284
192
767
419
105
73
291
159
1ACHom
1.2701
w
3556
34.77
41
41
1451
1419
0
0
0
0
1A-h1om
12701
w
3556
61.76
18
3
656
1139
0
0
0
0
1A-h1om
1270
w
3556
63.40
33
5
1162
2072
33
5
1162
2072
C
16C30ml
0.032
-
0.90
128
13M
1306
117C
1672
234
234
210
300
F
22A-tpi
0.989
-
27.69
0.0(
1306
f
145
4015
0
234
31
858
0
6
c)AED ervnson
3591
997
Emmlopelossgain
13885
13393
3105
3847
12
a) Infiltration
2441
668
143
b) Room ventilation
0
0
0
0
13
trdemalgains Occupants@ 230
2
460
0
0
Appliances/olher
1000
0
Subldtal(fines64113)
16327
15522
3627
39N
LessexPmzlload
0
0
0
0
I
Lestramfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
163Z7
15522
362
3990
15
Ductloads
25%
34%
4013
5251
25%
34%
892
1:2
Total room load
20340
20773
4
5342
Air required(
967
967
21)
15
zas
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
Rgtt-SUte®Utrversa1201919.021 RSU0810' 2021.1an-121321.40
...\WdgMoftHVAC1WYNNESUIDLING-THECOTTAGE.w Calc=M18 Frorf Doorfac,s SW Pagel
wrightsoftr RighW@ Worksheet Job:
Entire House °ato:
QUICK CALCS, INC. By.
317ST. LUCIE LANE, FORTPIERCE, FL34946 Phone:772-466-6799 Emeil:QUICKCALCS@,AOL.COM
1
Room name
DEN
SINKAREA
2
5mosdxall
24.0 ft
7.0 It
3
Room height
8A t heaVcool
8.1 ft heatlmol
4
Room dimensions
12.0 x 12.0 It
6.0 x 7.0 ft
5
Room area
144D ft°
42.0 fF
Ty
Construdion
U-vWue
Or
HTM
Area (fl
Load
Area (fF)
Load
number
I
(BluhfiF-°F)
I(Btuh4F)
or perimeter (ft)
(BWh)
or penmeter (ft)
(BWh)
Heat
Cool
Gros
WRIS
Heat
Cool
Gross
N/Pi3
Heat
Cool
6
V}I
13A-4=
0.143
In4.00
2.19
97
97
389
213
0
0
0 0
I—C
2glazing, droutr,
1.040
n
29.12
21.68
0
0
0
0
0
0 0
0
13A4ors
0.143
a
4.00
2.19
0
0
0
0
0
0 0
0
2glazing, drout,,
1.0401
a
29.12
39.42
0
0
0 0
0
0 0
0
11I
1100
03901
a
1092
10.34
0 0
0 0
0 0
0
0
Vrl
1344ocs
0.143
s
4.00
2.19
0 0
0 0
57
57
227
124
�--G
2glaang,droutr,
1.040
s
29,12
21.68
0 0
0 0
0 0
0
0
13AAM
0.143
w
4.00
2.19
97
79
315
172
0 0
0
0
1Ac1om
TO
w
34.77
0
0
0 0
0 0
0
0
1A-htom
1270
w
35.35.56 56
61.76
18
3
656
1139
0 0
0
0
IA-htom
12701
w
3556
63.40
0
0
0 0
0
0
0
0
c
16C30m1
0.032
-
030
128
144
144
129
184
42
42
38
54
F
22A-tpl
0.989
-
27.69
0.00
144
24
665
0
42
7
194
0
6
c)AEDe=rsion
-3
Fsealope losyain
±2:
459
175
12
a) Infiltrationb)
118
32
Roomventlation
0
0
13
Internal gains O=Pante@ 230
0
0
0
ApPlianossibther
0
0
0
Suftbl(linesfito13)
2558
2394
576
207
Lessewemalload
0
0
Leshzns`er
0
0
0
0
0
0
Redistribution
0
0
0
0
14
Sublotal
2558
2394
542
2 07
15
Duct loads
25%
34%
629
811
25%
34°/,
142
70
70
Total room bad
3187
3205
7
2
Airrequired(dm)
162
149
34
13
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
wIi=tits4 > 2021-Jan-121321A0
RIgr/Sute® Universal 201919.021 RSU08101 Page 2
...\WnghE ftHJAC\WYNNEBUIDLING-THECOTTAGE.n.p Calc=M1B Front Doorfacas:SW
wr7ghtsoft- Right-M Worksheet Job'.
Entire House Date:
QUICK CALCS, INC. By.
317ST. LUCIELANE,FORTPIERCE. FL34946 Phone: 772466-W99 Em il:QUIC CALCS@AOL.COM
1
Room name
CLOSET
GREAT ROOM
2
Exposadvall
0 ft
32.0 ft
3
Room height
8.1 a heaVbool
8.1 ft heat/=I
4
Room dimensions
9.0 x 7.0 ft
1.0 x 452D ft
5
Room area
63.0 fF
452.0 IF
Ty
Construction
U-value
Or
HTM
Area
meter
Load
number
(BMMtL-F)
(Bww
or pen(ft)
fth)
oorperimeter (ft)
(Btuh)
Heat
I Cool
Gross
N/PlS
Heat
Cool
Gross
NIPS
Heat
Cool
6
W
L—G
lak4ocs
0.143
n
4.00
2.19
0
0
0
0 178
160
640
350
2glaang,droutr,
1.040
n
29.12
21.63
0
0
0
0 18
0 537
400
13A4ocs
0.143
a
4.00
2.19
0
0
0
0
0
0 0
0
2glarirg,droutr,
1.040
a
29.12
39.42
0
0
0
0
0
0 0
0
11
11DO
0-M
a
10.92
10,34
0
0
0 0
0
0 0
0
tQ1 _
13A4ots
0.143
s
4A0
2.19
0
0
0 0
0
0 0
0
`u
2glaang,drout,
1.040
5
29.12
21.68
0
0
0 0
0 0
0
0
13AA=
0.143
w
4.00
2.19
0 0
0 0
81
40
161
88
lAolom
1270
w
35561
34.77
0 0
0 0
41
41
1451
1419
1A-hlom
1270
w
35561
61.76
0 0
0
0
0
0
0
0
lA-hlom
1270
w
35.56
63,40
0
0
0
0
0
0
0
0
C
16C30ml
0.032
-
0M
128
63
63
56
81
452
452
405
579
F
22A-fpl
0.989
-
27.691
1
I
0.00
63
0
0
0
452
32
886
0
6
o)AlDexcursion
1
2069
Envelope loWpir
56
80
4080
4903
12
a) Infiltrafim
0
0
53
148
b) Roomwn#Iatcn
0
0
0
0
13
Intemalgains: Oo:upants@ 230
p
0
2
Appliancesblher
460
p
0
Sublotal(Ilnes6tD13)
56
80
4619
5511
Leaiexkmalload
0
0
0
0
Lewiransler
0
0
0
0
Redistibulion
0
0
0
0
14
Subtotal
F.0
80
4619
5511
15
Dudloads
25%
34%
14
27
25%
34%
1135
1868
Total room load
Air requimd(dm)
70
107
54
7379
3
5
274
343
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
A RgkHl19.021 RS108101 2021-Jan-121321A0
...\WrigWoRHJACWYNNEBUIDLING-TECOTTAGE,rLp Calc=M78 FrodDoorfanes:SW Page
wrightser Right-M Worksheet yob:
Entire House By.
By.
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Ph ne: 772-466-6799 Email: OUICKCALCS@AOLdJM
1
Room name
M%STFR BATH
POWDER
2
EVosedwill
5.0 It
O It
3
Room height
8.1 ft heaVmol
8.1 ft heatlmol
4
Room dimensions
10.0 x 5.0 It
5A x 5.0 It
5
Roomaiea
I 50.0 ff
25.0 f8
Ty
Construction
U-value
Or
HTM
Area (ft)
Load
Area
Load
number
(BWh4F°FF)
(Btuw
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
I Cool
Gross
N/PIS
Heat
Cool
Gross
NIPS
Heat
Cool
6
y/
13AA=
0.143
n
4.00
2.19
0
0
0
0
0
0
0
0
�-G
2glazing, droutr,
1A40
n
29.12
21.68
0
0
0
0
0
0
0
0
13A-4=
0.143
a
4.001
2.19
0
0
0
0
0
0
0
0
utr ng,dro,
1.040
a
29.121
39.42
0
0
0
0
0
0
0
0
11
DI2glaa
11D0
0.390
a
%92
10.34
0
0
0
0
0
0
0
0
tW
13A4ors
0.143
s
4.00
2.19
41
34
134
73
0
0
0
0
-G
2glaang,droutr,
1.040
s
29.12
21.68
7
7
202
150
0
0
0
0
13A-4ocs
0.143
w
4.00
2.19
0
0
0
0
0
0
0
0
tAclom
1270
w
35.56
34.77
0
0
0
0
0
0
0
0
11A-htom
1270
w
35.56
61.76
0
0
0
0
0
0
0
0
1A-hlom
1270
w
3556
63.40
0
0
0
0
0
0
0
0
C
16C30m1
OA32
-
0.90
128
W
50
45
64
25
25
22
32
F
22A-tpl
0.989
-
27.69
0.00
50
5
138
0
25
0
0
0
6
c)AEDeuurson
0
Envelope loWgain
520
284
22
32
12
a) Infiltration
84
23
0
0
b) Room ventilation
0
0
0
0
13
Inkmalgains Oaupants@ 230
0
0
0
0
Appliancesro6ler
0
0
Subtotal(lines6b13)
604
307
22
32
Lese4ernal load
0
0
0
0
Ledisabutio
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
604
307
22
32
15
Ductloads
25%
34%
148
104
25%
34%
6
11
Total room Irad
752
411
28
42
Air required (dmi
36
19
1
2
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
-pw ,wig~ �. 2021-Jart121321.40
.9 A Pogll.SUL4DUriwml20lglg.D2l RSUOSICI Page4
...\Wngrtsoft FMAQWYNNEBUIDLING-THECOTTAGE.np Calc=MI8 Front Doorlaces:SW
wrightsoft° Right!® Worksheet
Entire House
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 PMre: 772466-6799 Email: OUICKCALCS@AOL.COM
Job:
Date:
By.
1
Room name
KITCHEN
LAUNDRY
2
Elposed wall
38.0 It
0 It
3
Room height
8.1 ft heaV000l
8.1 It heaV000l
4
Room dimensom
1.0 x 232.0 It
4.0 x 10.0 It
5
Roomarea
232.0 fI40.0
IF
Ty
Construction
U-gale
Or
HTM
Area (e)
Load
Area ( �
Load
number
(BtUW �
(BltJft�
or perimeter (ft)
(l3lh)
or perimeter (ft)
(Blh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
NrPS
Heat
Cool
6
y/
13AA=
O.
n
4.00
2.19
138
138
551
301
0
0 0
0
I-G
2glaang, oroutr,
1.040
n
29.12
21.68
0
0
0
0
0
0 0
0
13A4ocs
0.143
a
4.00
2.19
130
97
387
211
0
0 0
0
2glaang,drouir,
1.040
a
29.12
39.42
13
2 368
498
0
0 0
0
11I
11DO
0.390
a
10.92
10.34
20
20
223
211
0
0 0
0
YI/
13A-4=
0.143
s
4.00
2.19
41
41
162
89
0
0
0
0
t-G
2glaang,droutr,
1.040
s
29.12
21.68
0
0
0
0
0
0
0
0
Y/
13A4ocs
0.143
w
4.00
2.19
0
0
0
0
0
0
0
0
1Aclom
1270
w
35.56
34.77
0
0
0
0
0
0
0
0
to-htom
1270
w
35-%
61.76
0
0
0
0
0
0
0
0
1A-h1om
1270
w
35b6
63.40
0
0
0
0
0
0
0
0
C
16C30m1
0.032
-
0.90
128
232
232
208
297
4(
40
36
51
F
I
f
22A-to
0A9
-
27.69
0.00
232
i
38
1052
0
4(
0
0
0
6
c);m.,son
37
-1
Envelope WWgain
2951
1570
36
51
12I
a) NSlraton
w
175
0
0
f
b) Roomventilabon
0
0
0
0
13
Intemalgains O=pants@ 230
0
0
0
0
Applianoeslolher
1000
0
Subb&(lirtes6fi13)
3591
2745
1
36
51
Lessexamalload
0
0
0
0
Lesshanser
0
0
0
0
Redistribution
0
0
0
0
14
Subbtal
3591
2745
36
51
15
Duct loads
25%
34%
883
931
25%
34%
9
17
Total room bad
4474
3676
45
68
Airmquired(dm)
213
171
2
3
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
w~9"•--��� 2021-JarF121321:40
A R 911SuL-51JA ersal 201919.021 RSU08101
...\W69MOft HUAQWYNNEBUiDLING-THECOTrAGE.np Caic=MJ8 FrortDoorfaces:SW Page 5
1 F wrightsoft° RighW@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LANE, FORTPIERCE, FL34946 PWm:7724666799 EmaiI:QUICKCALCS@AOL.COM
1
Room name
STORAGE
2
5posedwall
8.0 ft
3
Room height
8.1 ft heaV=l
4
Room dimensoru
4.0 x 6.0 ft
5
Roomaw
24.0 1F
Ty
Condon
U-value
Or
HTM
Area (fF)
Load
Area
Load
number
EtuhAF-°�
(BWhMt'0
w perimeter (ft)
(Bfuh)
o>penmeter
Heat
Cool
Grose
N/P/S
Heat
Cool
Gross
N1P/S
Heat
Ccol
6
lR!
13A4=
0.143
n
4.00
2.19
32
32
130
71
�--G
2glaang,droutr,
1.040
n
29.12
21.66
0 0
0
0
laA-4=
0.143
e
4.00
2.19
32
32
130
71
2glaang,droutr,
1.040
a
29.12
39.42
0 0
0
0
11
11DO
0.390
a
10.92
10.34
0 0
0
0
13A-4=
0.143
s
4A0
2.19
0
0
0
0
2glaarg,droutr,
1.040
s
29.12
21.68
0
0
0
0
13A4w
0.143
w
4.00
2.19
0
0
0
0
1Ac1om
1270
w
3556
34.77
0
0
0
0
1A-hlom
1270
w
3556
61.76
0
0
0
0
1A-1h1om
1270
w
35.56
63.40
0
0
0
0
C
16C30ml
0.032
-
0.90
128
24
24
22
31
F
22A-Ipl
0.989I
-
27.69
0.00
24
8
222
0
6
c)AED ernnscn
1
3
Envelope IoWpn
502
170
12
a) Infiltratlon
135
37
b) RoomvenHlation
0
0
13
trtlemal gains: Oovpants@ 230
0
0
Appiiano=sotrar
0
Subtot31(1inw6b13)
637
207
L. nnal load
0
0
Less transfer
0
0
Redistribution
0
0
14
Subtotal
63
20
15
DUGloads
25%
29%
157
60
Total room load
794
266
Aire iced (Qm)
38
12
Calculations approved bvACCAto meet all requirements of Manual J tith Ed
Aftk " NnL oft- 2027-JaM27321:40
Righ-THEC T'rAG .rLp 79.021 RS ont01
o Page6
...\Wrigt�ofttNACIWYNNE BUIDLING-iHE COTTAGE.nq CaIc=MJB FrortDoortaces:SW
- wrightsoft
Duct System Summary o:
Entire House eY
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Plmw 772-466-6799 Email: QUiCKCALCS@AOL.COM
Project Information
For. WYNNE BUILDING CORP.
THE COTTAGE, FT. PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply/ return available pressure
Lowestftiction rate
Actual airflow
Total effective length (TEL)
Heating
0.50
in H2O
0.28
in H2O
0.22
in H2O
0.110/0.110
in H2O
0.080
in/10011
967
cfm
126
Supply Branch Detail Table
Cooling
0.50
in H2O
028
in H2O
022
in H2O
0.11010.110
in H2O
0.080
in/100ft
967
Dim
Name
Design
(Bluh)
Htg
(cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Mat
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
CLOSET
c 107
3
5
0.080
4.0
0x0
MFx
24.6
90.0
st1
DEN
h 3187
152
149
0.080
7.0
0x0
VIFx
33.5
90.0
st1
GREATROOM
c 3689
137
172
0.080
8.0
OxO
VIFx
14.6
70.0
GREATROOM-A
c 3689
137
172
0.080
8.0
OxO
VIFx
16.1
70.0
KITCHEN
h 4474
213
171
0.080
7.0
Ox0
VIFx
4.5
70.0
LAUNDRY
c 68
2
3
0.080
4.0
Ox0
VIFx
5A
70.0
MASTERSATH
h 752
36
19
0.080
4.0
OxO
VIFx
32.9
90.0
St1
MASTERSEDROOM
C 2671
107
124
0.080
7.0
OxO
VIFx
27.9
90.0
SH
MASTER BEDROOM -A
c 2671
107
124
0.080
7.0
OxO
VIFx
35.9
90.0
st1
POWDER
c 42
1
2
0.080
4.0
OxO
VIFx
29.2
90.0
st1
SNKAREA
h 718
34
13
0.080
4.0
0x0
VIFx
30.9
90.0
St1
STORAGE
h 794
38
12
0.080
4.0
OxO
VIFx
112
70.0
Supply Trunk Detail Table
Name
Trunk
Type
Htg
(cfm)
Clg
(cirri)
Design
FR
Veloc
(fpm)
Diam
(in)
HxW
(in)
Duct
Material
Trunk
st1
PeakAVF
441
437
0.080
561
12.0
0 x 0
YnlFlx
-Fk wrijhtsoft- 2021-Jan121321:41
w+-� •.�-.�.-e PogkSutc�Uriversa120t919.02t RSU08101 Pagel
ACCN ...lWngMoft HVAQWYNNEBUIDLING-THECOTTAGE P CaIc=MJ8 Froft Doorfams:SW
Return Branch Detail Table
Name
Grille
Sze(in)
Htg
(Cfm)
Cig
(cfrn)
TEL Design
(ft) FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Dud
MA
Trunk
rb1
Ox0
967
967
0 ' 0
0
0
Ox 0
VIFx
-+ w_rightsaft- 2021-Jar 12132141
RigftSute0Unverea1201919.021 RSU08101
...1Wrigftofl FNAQWY NEBUIDLING-THEC07rAGE. p Calc=M Fmd Doortaces SW Paget