HomeMy WebLinkAboutAPPROVED Holloway Residence_page_10 Sealed(1)UMCBMDPACDREVSHEET NAMESHEET SIZESHEET NUMBERHOLLOWAY RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-03CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5290 OAKLAND LAKE CIRCLE,
FORT PIERCE, FL 34951SYSTEM LABELINGRAPID SHUTDOWNSWITCH FORSOLAR PV SYSTEMLABEL LOCATION:AC DISCONNECT(PER CODE: NEC690.56(C)(3))LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)WARNINGELECTRIC SHOCK HAZARDLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.13(B))TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))ADHESIVE FASTENED SIGNS:· THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED.· WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING].· ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3]PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 36.3 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSWARNINGINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICELABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))! WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!NOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION PER CIRCUIT-VVAHz60290A240A1.2120LABEL LOCATION:COMBINER BOX(PER CODE: NEC690.52)DATA PER PANELTURN RAPID SHUTDOWNSWITCH TO THE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1)SERVICE POINT AND UTILITY METERINGMAIN SERVICE DISCONNECT /MAIN DISTRIBUTION PANEL5290 OAKLAND LAKE CIRCLE, FORT PIERCE, FL 34951LABEL LOCATION:MAIN SERVICE DISCONNECT / MAIN DISTRIBUTION PANEL, PV DISCONNECT(TEXT HEIGHT SHOULD BE A MINIMUM OF 3/8")(PER CODE: NEC 690.56(B) AND NEC 705.10)ENPHASE IQ COMBINER BOXALTERNATIVE POWER SOURCE ACDISCONNECTPV SOLAR ARRAYON ROOFCAUTION:POWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLWING SOURCES WITHDISCONNECTS LOCATED AS SHOWNOAKLAND LAKE CIRCLE,