Loading...
HomeMy WebLinkAboutAPPROVED Holloway Residence_page_4 Sealed(1)4'-0"(TYP.)4'-0"(TYP.) 43'-2"50'-5"REVSHEET NAMESHEET SIZESHEET NUMBERHOLLOWAY RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5290 OAKLAND LAKE CIRCLE, FORT PIERCE, FL 34951MODULE LAYOUTS-01SCALE: 3/32" = 1'-0"1MODULE LAYOUT(92) PV ROOF ATTACHMENT@ 24" & 48" O.C. MAX.(SEE SHEET S-02 FORATTACHMENT DETAIL)(SEE SHEET S-01.1 FOR PARTIALPRESSURE OF THE MODULE)MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 30 MODULESMODULE TYPE = SILFAB: SIL-380 BK (380W) MODULESWEIGHT = 41.9 LBS / 19.0 KG.MODULE DIMENSIONS = 70.7" x 39.98" = 19.63 SFUNIT WEIGHT OF ARRAY = 2.13 PSFLEGEND- WIND ZONE 1 (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e (TYP)(N) QRAIL LIGHT RAIL (TYP.)GENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED ASSHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE:SEE SHEET S-02.1 FOR SUPPORTING CALCULATIONS.2) EXISTING RESIDENTIAL BUILDING IS AN ASPHALT SHINGLE ROOFWITH MEAN ROOF HEIGHT IS 25 FT AND SYP 2"X4" ROOF TRUSSESSPACED 24" O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEMRETROFIT IS 26.6 DEGREES. CONTRACTOR TO FIELD VERIFY ANDSHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXISTBETWEEN PLANS AND IN FIELD CONDITIONS.* I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020 7TH ED. CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE LATERAL ANDUPLIFT WIND LOADS AND EQUIPMENT DEAD LOADS.WINDZONESNON - EXPOSED MODULESEDGE / EXPOSED MODULESSPANCANTILEVERSPANCANTILEVERZONE 14'-0"1'-4"2'-0"0'-8"ZONE 1'XXXXZONE 2e2'-0"0'-8"2'-0"0'-8"ZONE 2nXXXXZONE 2r2'-0"0'-8"2'-0"0'-8"ZONE 3e2'-0"0'-8"2'-0"0'-8"ZONE 3rXXXXDYNORAXX DYNOBONDSEE SPEC. SHEET/DS-06PV MODULEMODULE FRAMEDYNORAXX DYNOBONDSEE SPEC. SHEET/DS-06PV MODULEMODULE FRAME(E) BACK YARD ROOFROOF TYPEARRAYAREA(Sq. Ft.) ROOFAREA(Sq. Ft.)ROOFAREACOVEREDBY ARRAY(%)TILTAZIMUTHTRUSSSIZETRUSSSPACING#1ASPHALTSHINGLE215.93442.6348.7826.6°90°2"X4"24" O.C.#2ASPHALTSHINGLE196.30397.1749.4226.6°180°2"X4"24" O.C.#3ASPHALTSHINGLE117.78294.2240.0326.6°270°2"X4"24" O.C.#4ASPHALTSHINGLE58.89275.6421.3626.6°0°2"X4"24" O.C.(E) FRONT YARD ROOF #1TILT - 26.6°AZIM. -90°(N) (30) ENPHASE IQ7PLUS-72-2-USMICROINVERTERSROOF #1(11) SILFAB: SIL-380 BK (380W)MODULESROOF #3(06) SILFAB: SIL-380 BK (380W)MODULESROOF #2(10) SILFAB: SIL-380 BK (380W)MODULESROOF #4(03) SILFAB: SIL-380 BK (380W)MODULESROOF #3TILT - 26.6°AZIM. -270°ROOF #2TILT - 26.6°AZIM. -180°ROOF #4TILT - 26.6°AZIM. -0°