HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE City, State, zip: FT. PIERCE, FL, Permit Dice: ST. LUCIE COUNTY Owner: WYNNE BUILDING CORP. Permit Number. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wall Types(1718.3 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 4. Number of Bedrooms 1 c. NIA R= fe d N/A 5. Is this a worst case? Yes R= ft2 11. Ceiling Types(1336.0 sgft.) Insulation Area 6. Conditioned floor area above grade (ft2) 1306 a• Under Attic (Vented) R=30.0 1306.00 ft2 Conditioned floor area below grade (ft2) 0 b. Knee Wall (Vented) R=19.0 30.00 ft2 7. Windows(128.9 sgft.) Description Area c. N/A R= ftz 12. Ducts, location & insulation level R a. U-Factor: S91, U=1.02 76.04 ft2 SHGC: SHGC=0.29 ft? a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120 b. U-Factor: Sgl, U=1.03 40.00 ft2 b C. SHGC: SHGC=0.27 C. U-Factor: Sgl, U=1.02 12.85 ft2 13. Cooling Systems kBtu/hr Efficiency SHGC: SHGC=0.26 a. Central Unit 29.D SEER:14.00 Area Weighted Average Overhang Depth: 4,701 ft Area Weighted Average SHGC: 0.281 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area U-Factor.(AVG) N/A a. Electric Heat Pump 27.0 HSPF:8.20 N/A ft2 SHGC(AVG): N/A 9. Floor Types insulation Area 15. Hot Water Systems a. Slab -On -Grade Edge Insulation R= 0.0 1306.00 ft2 a. ElectricTankless Cap: 1 gallons b. N/A R= ft2 EF.0.600 c. NIA R= ftz b. Conservation features 16. Credits NoneNone Glass/Floor Area: 0.099 Total Proposed Modified Loads: 41.30 Total Baseline Loads: 43.21 PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this'1`3, Code. calculation indicates compliance PREPARED BY: with the Florida Energy Code. iiq F Before construction is completed 7 DATE: ii-7�Q21 this building will be inspected for A "y; �.14 compliance with Section 553.908 Q 1 hereby certify that this building, as des' di -is' rn liance p�'�j$ Florida Statutes. * � with the Florida Energy Co . WME OWNER/A T BUILDING OFFICIAL: DATE: U DATE: - Compliance mmquir&Q r_ar lfi,�#;- h..4-k ., 1-11_-. -� • - �•• ..011..1.1 u111L u1011u1acu.lrer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 6/7/2021 11 AT00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUIDDING-THE COTTAGE IMPACT Address type: Street Address BuiklingType: User Bedrooms: 1 Lot#: - Owner. WYNNE BUILDING CORP. Conditioned Area: 1306 Block/SubDivision: - TotalStories: 1 PlatBook: Builder Name: WYNNE BUILDING CORP. Worst Case: Yes Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY Rotate Angle: 180 County: St. Lucie Jurisdiction: Cross Ventilation: No City, State, Zip: FT. PIERCE, Family Type: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban YearConstruct: Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range _FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume _1 EntireHouse 13W76.2001953125 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated 1 MASTER BEDROOM 234 1895.4 No 0 1 Yes Yes Yes _2 DEN 144 1166.4 No 0 Yes Yes Yes _3 SINK AREA 42 340.2 No 0 Yes Yes Yes _4 CLOSET 5 63 510.3 No 0 No Yes Yes GREAT ROOM 452 3661.2 No 2 Yes Yes Yes 6 MASTER BATH 50 405 No 0 Yes Yes Yes _7 POWDER 25 202.5 No 0 No Yes Yes _8 KITCHEN 232 1879.2 Yes 0 Yes Yes Yes _9 LAUNDRY 40 324 No 0 No Yes Yes 10 STORAGE 24 192 No 0 0 Yes Yes Yes FLOORS (Total Exposed Area = 1306 sq.ft.) # FloorType Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _1 Slab -On -Grade Edge Ins MASTER BEDROOM 31 0 234 fit 0.473 - 0.00 1.00 0.00 _2 Slab -On -Grade Edge Ins DEN 24 0 144ft 0.473 - 0.00 1.00 0.00 _3 Slab -On -Grade Edge Ins SINKAREA 7 0 42ft 0.473 - 0.00 1.00 0.00 _4 Slab -On -Grade Edge Ins CLOSET 1 0 63ft 0.473 - 0.00 1.00 0.00 5 Slab -On -Grade Edge Ins GREAT ROOM 32 0 452 It 0.473 - 0.00 1.00 0.00 _6 Slab -On -Grade Edge Ins MASTER BATH 5 0 50ft 0.473 - 0.00 1.00 0.00 _7 Slab -On -Grade Edge Ins POWDER 1 0 25It OA73 - 0.00 1.00 0.00 _8 Slab -On -Grade Edge Ins KITCHEN 38 0 232ft 0.473 - 0.00 1.00 0.00 _ 9 Slab -On -Grade Edge Ins LAUNDRY 1 0 40 It 0.473 - 0.00 1.00 0.00 10 Slab -On -Grade Edge Ins STORAGE 21 0 24ft 0.304 - 0.00 0.00 1.00 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1376 ft' 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio It in) Area RBS IRCC _ 1 Full attic Vented 150 1306 ft- N N CEILING (Total Exposed Area = 1336 sq.ft.) # Ceiling Type Space R-Value Ins.Type Area U-Factor Framing Frac. Truss Type 1 UnderAttic(Vented) MASTER BEDROOM 30.0 Blown 234.0ft= 0.053 0.10 Wood _2 UnderAttic(Vented) DEN 30.0 Blown 144.011- 0.053 0.10 Wood _3 UnderAttic(Vented) SINK AREA 30.0 Blown 42.Oft' 0.053 0.10 Wood _4 UnderAttic(Vented) CLOSET 30.0 Blown 63.Oft- 0.053 0.10 Wood _5 UnderAttic(Vented) GREAT ROOM 30.0 Blown 452.Ofe 0.053 0.10 Wood _6 UnderAtfic(Vented) MASTER BATH 30.0 Blown 50.0ft' 0.053 0.10 Wood _7 UnderAttic(Vented) POWDER 30.0 Blown 25.0fF 0.053 0.10 Wood _8 UnderAftic(Vented) KITCHEN 30.0 Blown 232.0ft' 0.053 0.10 Wood _9 UnderAttic(Vented) LAUNDRY 30.0 Blown 40.0ff2 0.053 0.10 Wood 10 UnderAtfio(Vented) STORAGE 30.0 Blown 24.Oft2 0.030 0.11 Wood _ 11 Knee Wall(Vented) GREAT ROOM 19.0 Blown 30.011' 0.045 0.11 Wood WALLS (Total Exposed Area = 1718 sq.ft.) Note: First wall orientation below is as entered. Actual orientation is modified by the rotate angle (180 degrees) as shown in the "Project" section on page 1. VAdjacent Cavity Width Height Area U- Sheath Fen. Solar Below # Omt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade 1 S=>N Exterior Conc. Blk - Int Ins MASTER BEDROOM 4.1 18.0 0 8.0 1 145.5 0.149 0 0 0.30 0% 2 W=>E Exterior Cone. BIk- Int Ins MASTER BEDROOM 4.1 13.0 0 8.0 1 105.1 0.149 0 0 0.30 0% _3 N=>S Exterior Conc. Blk- Intlns DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _4 W=>E Exterior Conc. Blk- Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _5 S=>N Exterior Conc. Blk- Intlns SINKAREA 4.1 7.0 0 8.0 1 56.6 0.149 0 0 0.30 0% 6 N=>S Exterior Conc. Blk- Int Ins GREAT ROOM 4.1 22.0 0 8.0 1 177.8 0.149 0 0 0.30 0% _7 W=>E Exterior Conc.Blk- Intlns GREAT ROOM 4.1 10.0 0 8.0 1 80.8 0.149 0 0 0.30 0% _ 8 S=>N Exterior Conc. Blk - Int Ins MASTER BATH 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _9 N=>$ Exterior Conc. Blk- Intlns KITCHEN 4.1 17.0 0 8.0 1 137.4 0.149 0 0 0.30 0% _10 E=>W Exterior Conc. Blk- Intlns KITCHEN 4.1 16.0 0 8.0 1 129.3 0.149 0 0 0.30 0% _ 11 S=>N Exterior Conc. Blk- Int Ins KITCHEN 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _ 12 N=>S Exterior Conc. Blk- Int Ins KITCHEN 4.1 35.0 0 8.0 1 282.9 0.149 0 0 0.30 0% _13 NaS Exterior Conc. Blk- Intlns STORAGE 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.30 0% _14 NHS Exterior Conc. Blk- Intlns STORAGE 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.30 0% 15 N=>S Garage Frame - Wood MASTER BEDROOM 11.0 30.0 0 &0 0 240.0 0.092 0 0.23 0.30 0% DOORS (Total Exposed Area = 20 sq.ft.) Width Height # Omt Adjacent To Door Type Space Stones U-Value Ft In Ft In Area _1 E=>W Insulated KITCHEN None 0.32 3.00 0 6.00 8 20.OfP 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 129 sq.ft.) / Wall -Overhang- / # Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation InteriorShade Screening -1 W=>E 2 Metal Low-E Single Yes 1.02 0.29 N N 32.02 1.0 it 5 in 1.0 it 5 in None None -2 W=>E 4 Metal Low-E Single Yes 1.02 0.29 N N 18.4f12 1.0 ft 5 in 1.0 ft 5 in None None 3 N=>S 6 Metal Low-E Single Yes 1.02 0.29 N N 18.02 1.0 ft 5 in 1.0 ft 5 in None None _4 W=>E 7 Metal Low-E Single Yes 1.03 0.27 N N 40.Oft2 12.0 It 0 in 1.0 ft 5 in None None -5 S=>N 8 Metal Low-E Single Yes 1.02 0.29 N N 6.9ft2 1.0 ft 5 in 1.0 ft 5 in None None 6 E�W 10 Metal Low-E Single Yes 1.02 026 N N 12.8ft2 1.0 ft 5 in 1.0 ft 5 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) _1 Wholehouse Proposed ACH(50) 0.00026 881 48.35 90.78 0.0907 5.0 All GARAGE # FloorArea Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 280 W 280 ft2 35 ft 8 ft 11 MASS # Mass Type Area Thickness FurnitureFraction Space 1 Default(8lbs/sq.ft.) 0 ft2 0 it 0.30 MASTER BEDROOM -2 Default(8lbs/sq.fL) 0 it- 0 It 0.30 DEN _3 Default(81bs/sq.fL) 0 ft2 0 it 0.30 SINK AREA _4 Default(81tu/sq.ft) 0 ft2 0 ft 0.30 CLOSET -5 Default(8 lbs/sq.ft.) 0 ft2 0 ft 0.30 GREAT ROOM 6 Default(81bs/sq.fL) 0 ft2 0 ft 0.30 MASTER BATH _7 Default(Blbs/sq.ft.) 0ft2 Oft 0.30 POWDER _8 Default(8lbs/sq.ft.) 0 ft2 0 it 0.30 KITCHEN _9 Default(8lbs/sq.ft) 0ft2 Oft 0.30 LAUNDRY 10 Default(81bs/sq.ft.) 0 ft2 Oft 0.30 STORAGE HEATING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity --GeothermalHeatPum p- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Heat Pump Split/Single HSPF: 8.20 27.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm _1 Central Unit Split/Single SEER:14.0 29.0 0 0.80 sys#1 1 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipelns. Pipe length 1 Electric Tankless Garage 0.60 (0.60) 1.00 gal 61 gal 120 deg Standard None 82 Recirculation RecircControl Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff _ 1 No NA NA NA No NA NA NA None DUCTS - VDuctSupply— —Return— Air CFM 25 CFM 25 HVAC # # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6.0 120 ft' Attic 6.0 45 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling []Jan [] Feb [ ] Mar [I Apr []May [XJ Jun [X] Jul [X] Aug [X] Sep [ ] Oct []Nov []Dec Healing [X] Jan [XJ Feb [X] Mar [ ]Apr [ ]May [ ]Jun [ ]Jul []Aug [ ]Sep [ ]Oct [X] Nov [X] Dec Venting []Jan []Feb (X]Mar [X]Apr []May []Jun []Jul []Aug []Sep [)]Oct [)]Nov []Dec Schedule: HERS 2006Reference Hours VThermostat Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 _ Cooling (WD) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 _ Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _ Heating (WD) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 _Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 6/7/2021 11:47:OOAM EnergyGauge® USA 7.0.00- FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Owner. WYNNE BUILDING CORP. Jurisdiction: Y U Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _ U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeableinsulationshall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including above -garage insulation. maintain permanent contact with the underside of and cantilevered subfloor decking, or floor framing cavity insulation floors) shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrowcavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garageseparation Air sealing shall be provided between the garage and oonditionedspaces. Recessedlighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall onextedorwall and tubs shall separate them from the showers and tubs. beinsulated. Electricallphonebox The air barriershall be installed behind electrical or onextedorwalls communication boxesorair-sealedboxes shall be installed. HVAC register boot,, HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. THE COTTAGE,FT. PIERCE,FL, 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 1 5. Is this a worst case? Yes 6. Conditioned floor area above grade (W) 1306 Conditioned floor area below grade (ft') 0 7. Windows" Description Area a. U-Factor: Sgl, U=1.02 76.04 e SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.03 40.00 ft2 SHGC: SHGC=0.27 c. U-Factor. Sgl, U=1.02 12.85 fe SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 8. Skylights Description Area U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R= 0.0 1306.00fe b. N/A R= ftz c. N/A R= ftz 10. Wall Types(1718.3 sqft.) Insulation Area a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 c. N/A R= fe d. N/A R= ftz 11. Ceiling Types(1336.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 ft2 b. Knee Wall (Vented) R=19.0 30.00 ft2 c. N/A R= ftz 12. Ducts, location & insulation level R ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120 b. C. 13. Cooling Systems kBtu/hr Efficiency a. Central Unit 29.0 SEER:14.00 14. Heating Systems kBtu/hr Efficiency a. Electric Heat Pump 27.0 HSPF:8.20 15. Hot Water Systems a. ElectricTankless Cap: 1 gallons EF: 0.600 b. Conservation features None 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: _�� -�� Date: Address of New Home: THE COTTAGE City/FL Zip: r SAS �5.�5 �,'3`�q5� 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 Wrightsoft- Project Summary Job: Entire House BBy QUICK CALCS, INC. 317 ST. LUCIE LANE, FORTPIERCE, FL34946 Phone: 772466.6799 Email: QUICKCALCS@AOL.COM Proiect Information For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16327 Btuh Ducts 4013 Btuh Structure Duds 15522 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 5251 0 Btuh Btuh none e) Humidification 0 Btuh Blower 0 Btuh Piping 0 Bluth Equipment load 20340 Btuh Use manufacturers data n Infiltration Rate/swingg multiplier Equipment 0.95 sensible load 19734 Btuh Method Simplified Construction quality Average Latent Coolie Equipment 9 q pmerrt Load Sizing Fireplaces 0 Structure 2094 Btuh Ducts 1524 Btuh Central vent (0 cfin) 0 Btuh Heatingg Cool' Area (none) (ft) 1306 1306 Volume (ft3) 10579 10579 Equipment latent load 3618 Btuh Air changes(hour 0.45 0.23 Equipment Total Load (Sen+Lat) 23352 Btuh Equiv. AVF (cfm) 79 41 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Canner Trade CARRIER Trade CARRIER Model CH14NBO3000GOA0 Cond CH14NBO3000GOAD AHRI ref 9162387 Coil FX4DNBO43L AHRI ref 9162387 Efficiency 8.2 HSPF Efficiency 11.5 EER,14 SEER Heatinglnput Sensiblecooling 20300 Btuh Heating output 28000 Btuh @47-F Latent cooling 8700 Btuh Temperature rise 26 OF Total cooling 29000 Btuh Actual air flow 967 cfin Actual airflow 967 cfm Airflowfactor 0.048 cfin/Btuh Airflowfactor 0.047 cfin/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point= 34 OF Backup: Input=5 kW, Output=18005 Btuh, 100AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. Wri�glhtsoit� 2021-Jan121321:40 ....,4,..,.., RigHSJte®Uriwml201919.021 RSU08101 Page t ftAHVAC\WYNNEBUIDLING.THECOTTAGE.Rp Calc=M16 Frort Doorfams SW wrightsofr Right -A) Worksheet Job: Entire House Date: QUICK CALCS, INC. By, 317 ST. LUCIE LANE, FORLPIERCE, FL34946 Ph0re:772-066-6799 Email: QUICKCALCS@/AOL.COM 1 Room name 2 E>posed wall Entire Houma MASTER BEDROOM 3 Room height 145.0 it 8.1 it 31.0 It 4 Room dimensons 8.1 It heatlmol 5 Roomarea fl' 13.0 x 18.0 It 234.0 ft' Ty Construction U-value Or HTM Area Load Area Load number I (Bvh/fF--°F) (BWhtF) or perimeter (ft) (Btuh) or perimeter (ft) (Btrh) Heat Cool Gross N/P/S Heat Coal Heat Cool 6 Vq 13A-4= 0.143 n 4.00 2.19 446 427 1710 9340 L—G 2glaang, droutr, 1.040 n 29.12 21.68 18 0 537 4000 0 c 0 0 13A-0gs 0.143 a 4.00 219 162 129 516 2820 0 0 2 glaang, tlroutr, 1.040 a 29.12 39.42 13 2 368 498 0 11 11D0 0390 a 1092 1034 20 20 223 2110 0 y/ I—C 13A-0ors 0.143 s 4.00 2.t9 284 277 1107 6056 584 319 2glaang, droutr, 13A-4= 1.040 0,143 s w 29.12 4A0 21.68 2.19 294 7 192 7 202 767 150 4193 T 0 0 1Aciom 1270 w 35.56 34.77 41 41 1451 14190 291 0 159 1A-htom 1270 w 3556 61.76 18 3 656 1139 0 0 0 C 1A-hiom 1270 w 35b6 63.40 33 5 1162 2072 1162 2072 F 16C30m1 22A-gil 0.032 - 0.90 128 1306 1306 117C 1672 210 300 0.989 - 27.69 0.00 1306 145 401E 01 858 0 6 c)AEDe=rson 3591 997 Errvelope loss/gain 13885 13393 3105 3847 12 a) Infiltia4on 2441 668 522 143 b) Room ventilation 0 0 0 0 13 Internal gains O—Pmt@ 230 2 460 p 0 Appliancesrother 1000 0 Subhrtal(lines6m13) 16327 15522 3627 3990 Lesexdemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 14013 15251 3892 15 Duct loads 25% 34% 4073 5251 25% 34% 892 13990 7352 352 Total room load 20340 20773 4518 5342 Air required(dm) 967 967 215 249 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed wrl9lsbvl'C^ 2021-Jan-121321:40 RNG-THEC07rArE.np 919.021 RSU08107 Pagei ...\WdgFlsoft M/ACIWYNNE BUIDLING-hIE COTfAGE.np Calc=M18 FrortDoorfaces:SW wrightsoft° Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772>66-6799 EmaiI:QU1CKCALCS@AOL.COM 1 Room name DEq SINKAREA 2 Exposed wall 24.0 It 7.0 ft 3 Room height 8.1 ft heaVcool 8.1 ft heaVmol 4 Room dimensions 12.0 x 12D It 6.0 x 7.0 ft 5 Roomarea 144.0 ft' 42.0 IF Ty Construction U-value Or HTM Area Load Area number (BWh/ft'-°F) (13WhM') or perimeter (ft) (BWh) or penmeelr (it) (Btuh) Heat Cool Gros NIPS Heat Cool Gros NIPS Heat Cool 6 V"13A-4oa 0.143 n 4.00 2.19 97 97 389 213 0 0 0 0 2glaang,droutr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 13A4os 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2glaang,dro&,, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 W 1--(i 1344= 0.143 s 4.00. 2.19 0 0 0. 0 57 57 227 0 124 2glazing, droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 13A4ors 6.143 w 4.00 2.19 97 79 315 172 0 0 0 0 1Aclom 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 G IA-hlom 1270 w 35.56 61.76 18 3 656 1139 0 0 0 0 IA-hlom 1270 w 35M 63.40 0 0 0 0 0 0 0 0 C 16C30ml 0.032 - 0.90 128 144 144 129 184 42 42 38 54 F 22A-Ipl 0.989 - 27.69 0.00 144 24 665 0 42 7 194 0 6 c)AED exarson 574 -3 Envelope loss/gwn 2154 2283 459 175 12 a) Infiltration 404 ill 118 32 b) RoornwrdlaVon 0 0 0 0 13 Internal gains Cmpanls@ 230 0 0 0 0 Applianrestther 0 0 2558 2394 576 207 Les wdarnal load 0 0 0 0 Lestransfer 0 0 0 0 [Subbtal(lines6tt13) Redistribution 0 0 0 0 14 Subbfal 2558 2394 576 207 Dud loads 25% 34% 629 811 25% 34% 142 70 Total room load 3187 3205 718 278 Air required (dm) 152 149 34 13 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed -YFr- wrlglftsoTC- 2021-Jarrv121321:40 Ate! A. RightSuteCa Urmersal 201919.021 RSUOBI01 Paget ...\WngtEot HVAC\WYNNEBUIDLING-THEC07rAGE.np Calc=M18 FrortDoorfacas:SW } wrightsoft- RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-066£799 Email: QUICKCALCS@AOL.COM i Room name CLOSET GREAT ROOM 2 5possdwall 0 It 32.0 It 3 Room height at ft heaV000l 8.1 a heaftol 4 Room dimermons 9.0 x 7.0 It 1.0 x 4520 It 5 Room area 63.0 IF 452.0 ft' Ty Construction U-value Or HTM Area (ftF) Load Area number I (SUhW---F) (BbAffe) or pedmeta (ft) (Btuh) or perimeterLoad (ft) (BWh) Heat Cool Gross NiP/S Heat Cool Gross WP/S Heat Cool 6 Ur! �G 13A-4= 0.143 n 4.00 2.19 0 0 0 0 178 160 640 350 2glazing, droutr, 1.040 n 29.12 21.68 0 0 0 0 18 0 537 400 13A-4ars 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2glaang,croutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 11DO 0.390 a 1092 10.34 0 0 0 0 0 0 0 0 VN �-G 13AAors 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 2glaarg,croutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 81 40 161 88 1Actom 1270 w 3556 34.77 0 0 0 0 41 41 1451 1419 1A-hlom 1270 w 3556 61.76 0 0 0 0 0 0 0 0 IAhlom 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 C 16C-30ml 0.032 - 0.90 128 63 63 56 81 452 452 405 579 F 22A-tpl 0.989 - 27.69 0.00 63 0 0 0 452 32 886 0 6 c)AED ex=rsion -i 2069 Envelope loss/gmn 56 80 1 4080 4903 12 a) Infiltration 0 0 539 148 b) Roomventlation 0 0 0 0 13 Internal gains Coarpants@ 230 0 0 2 460 Appliancas/otlrer 0 0 Subtotal(lines6to 13) 56 80 4619 5511 Lessedemal load 0 0 0 0 Lestransfer 0 0 0 0 Redistibuton 0 0 0 0 14 Sub48al 56 80 4619 5511 15 Duct loads 25% 34°/, 14 27 25/ 34% 1135 1868 Total room load 70 107 5754 7379 Air required(cfM) 3 5 274 343 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed wrlgftcw /t- 2021-Jan-121321AO .4CCA '^ RgttSuteOUdwml201919.021RSU08101 Page ...1WrigltoflHVAaWYNNEBUIDLING-THECOTTAGEnp Calc=MB FrontDoorfaces:SW wrightso Right- J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34W Phom:772466.6799 Email: QUICKCALCS@AOL.COM 1 Room name MASTER BATH POWDER 2 Eposedvrall 5.0 It 0 It 3 Room height 8.1 It heallobol 8.1 It heat/mol 4 Room dimensions 10.0 x 5.0 it 5.0 x SA It 5 Room area SOA If 25,0 fe Ty Construction U-value Or HTM Area ( Load number (Btuh4l;'r7 (Byhgt'0 or perimeter (ft) (Btuh) orsperimeter (ft) (Byh) Heat Cool Gros WP/S Heat Cool Gross N/PS Heat Ccol 6 l7/ 134-4os 0.143 n 4.00 2.19 0 0 0 0 0 �-G 2glaarg, or outr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 0 13AAo s 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2glaang,ciroutr, 1.040 a 29.12 39.42 0 0 0 0 11 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 lakAors 0.143 s 4.00 2.19 41 34 134 73 0 0 0 0 0 2glaang,droutr, 1.040 s 29.12 21.68 7 7 202 150 0 -0 0 0 134-0ors 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1Ac1om 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 to-hlom 1270 w 3556 61.76 0 0 0 0 0 0 0 0 1A-hlom 1270 w 35M 63.40 0 0 0 0 0 0 0 C 16C30ml 0.032 - 0.90 128 50 50 45 64 25 25 22 0 32 F 22A-IpI 0289 - 27.69 0.00 50 5 138 0 25 0 0 0 6 c)AM euvrsion -4 0 Envelope lcs4gain 520 284 22 32 12 a) Infiltration 84 23 0 0 b) Roomverdlation 0 0 0 0 13 Internal gains: Omipants@ 230 0 p p p ApplianoJother 0 0 Subtotal(linestito13) 604 307 22 32 Lessexemalload 0 0 0 0 Lesstranskr 0 0f25/34%1 0 Redistribution 0 00 0 14 Subtotal 604 3070 22 32 15 DUCloads 25% 34% 148 104 6 11 Total room ]bad 752 411 28 42 Air required(cfm) 36 19 1 2 Calculations approved byACCAto meet all requirements of Manual J 8th Ed wrl9f+tsoT!' 202tJah727 A&A Rgh ®Urr1.021RSU081 Page ...\WdghEcftHACWYNNEBUIDLING-THECOTAGE.nLp CaIc=MB FrortDoorfacesSW t� wrightsoft- Right-M Worksheet Jab: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phore: 77246M799 Email: QUICKCALCS@10LCOM 1 Room name 2 KITCHEN LAUNDRY Exposedwall 38.0 ft 0 R 4 3 Room height Room dimensons 8.1 itheaVwol 8.1 ItheaVcool 5 Room area 1.0 x 232.0 R 232.0 f 4.0 x 10.0 ft 40.0 IF Ty Construction U-value Or HTM Area Load Area Load number (BIuhMF°F) (BW111110 or perimeter (R) (Btuh) or perimeter (R) (13Wh) Heat Cool Gros NIPS Heat Cool Gros N/P/S Heat Cool 6 Y)/ 13A-4ols 0.143 n 4A0 2.19 138 138 551 301 0 �-G Yggla-0n�droutr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 0 0 0 13A0.143 a 4.00 2.19 130 97 387 211 0 0 0 0 2glaang,droutr, 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 11 11DO 0.390 a 10.92 10.34 20 20 223 211 0 0 0 0 1344ocs 0.143 s 4.00 2.19 41 41 162 89 0 0 0 0 2glaang,droutr, 1.040 s 29.12 21.65 0 0 0 0 0 0 0 0 0.143 w 4.00 2.19 0 0 0 0 0 0 0 T�i13A4= 1Aclom 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 to-htom 1270 w 3556 61.76 0 0 0 0 0 0 0 0 0 to-hlom 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C 16C30ml 0.032 - 020 128 232 232 2M 297 40 40 36 51 F 22A-ipl 0.989 - 27.69 0.00 232 38 1052 0 40 0 0 0 6 c)AED exalrson -37 _1 Envelope losslgain 2951 1570 36 51 12 a) Witrabon 640 175 1 0 0 b) Roomventilabon 0 0 0 0 13 Intemalgains: Ooolpants@ 230 0 0 0 0 Appliances/other 1000 0 Subhrtzl(Iines6to 13) 3591 2745 36 51 Lesexamalload 0 0 0 0 Less 4 0 0 0 0 Redistributioibuto n 0 0 D 0 14 Subtotal 3591 2745 36 57 15 Dudloads 25% 34% 863 931 25% 34% 9 17 Total room load 4474 3676 45 68 Air required(dm) 213 171 2 3 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed -+k- .rAoft so 2021Ja 121321:40 h Right-SufeOUriversa1201919.021 RSU08101 Page ._lWrigW6 ftHUAC1WYNNEBUIDLING-THECOTTAGE.np Calc=W8 FrortDoorfaoes:SW wrightsoft• Right-M Worksheet Job: Entire House Del QUICK CALCS, INC. 8y- 317 ST. LUCIE LANE.FORTPIERCE. FL34946 P1nre:7724666799 Email: QUICKCALCSa(?AOL.COM 1 Rcom name STORAGE 2 Eposedvall 8A ft 3 Room height 8.1 ft heaV000l 4 Room dimensions 4.0 x 6.0 d 5 Room area 240 fF Ty Construction U-value Or HTM Area (� Load Area Load number (BWh4t�°) (BWWI or perimeter (ft) (BWh) or perimeter Heat Cool Gross NtPB Heat Cool Gross NIPS Heat Cool 6 VL—(' 13A-4ors 0.143 n 4.00 2.19 32 32 130 71 2glavng,droutr, 1.040 n 29.12 21.68 0 0 _ 0 0 13A4o 0.143 a 4.00 2.19 32 32 130 71 2glazing, oroutr, 1.040 a 29.12 39.42 0 0 0 0 11 11DO 0.390 a 1022 10.34 0 0 0 0 v(/ _ 134-4ors 0.143 5 4.00 2.19 0 0 0 0 •—u 2931glazing, 1.040 s 29.12 21.68 0 0 0 0 0.143 w 4.00 2.19 0 0 0 0 tAclom 1270 w 3556 34.77 0 0 0 0 IA-hlom 1270 w 35.56 61.76 0 0 0 0 1A-hlom 1270 w 35.% 63.40 0 0 0 0 C 16C-30ml 0.032 - 0.90 128 24 24 22 31 F 22A-tpl 01989 - 27.69 0.00 24 8 222 0 6 c)AED exr mon -3 Envelope loss/gain 502 170 12 a) Infiltration 135 37 b) Rcomwntilation 0 0 13 Internal gains O¢upan4@ 230 0 0 Appliancies/other 0 Subtotal(lines6to13) 637 P07 Lesexemalload 0 0 Lestransfier 0 0 Redistribution 0 0 14 Subtotal 6370 207 15 Dud loads 259% 29% 157 60 Total room load 794 266 Air required (dm) 38 12 Calculations approved by_ACCAto meet all requirements of Manual J 8th Ed I&K-t}r- 2021-Jarv121321:40 RigitSdteOUmersal 201919.021 RSU08101 Page 6 ...\Wrig%oft WAQWYNNESUIDLING-THEOOTTAGE.np Calc=Ml8 FrontDoorfawa SW wrightsoft� Duct System Summary o b: Entire House By. QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL34946 Phom: 772466-6799 EmaiCOUICKCALCS AOL.COM Project Information For: WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 dim 126 ft Supply Branch Detail Table Cooling 0.50 in H2O 028 in H2O 0.22 in H2O 0.11010.110 in H2O 0.080 in/10011: 967 chn Name Design (Btuh) Htg (clm) CIg (dm) Design FR Diam (in) H x W (in) Duct mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk CLOSET c 107 3 5 0.080 4.0 OxO VIFx 24.6 90.0 st1 DEN h 3187 152 149 0.080 7.0 OxO VIFx 33.5 90.0 st1 GREATROOM C 3689 137 172 0.080 8.0 Ox0 VIFx 14.6 70.0 GREAT ROOMA c 3689 137 172 0.0W 8.0 OxO VIFx 16.1 70.0 KITCHEN h 4474 213 171 0.080 7.0 OxO VIFx 4.5 70.0 LAUNDRY C 68 2 3 0.080 4.0 Ox0 VIFx 5.4 70.0 MASTERBATFI h 752 36 19 0.080 4.0 Ox0 MFx 32.9 90.0 st1 MASTER BEDROOM c 2671 107 124 0.080 7.0 OxO VIFx 27.9 90.0 SH MASTERBEDROOM-A c 2671 107 124 0.080 7.0 OxO VIFx 35.9 90.0 st1 POWDER C 42 1 2 0.080 4.0 OxO VIFx 292 90.0 sH SMAREA h 718 34 13 0.080 4.0 OxO VIFx 30.9 90.0 st1 STORAGE h 794 38 12 0.080 4.0 1 Ox0 VIFx 112 70.0 Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg Minn) Design FIR Veloc (fpm) Diam (in) H x W Qn) Duct Material Trunk SO PeakAVF 441 437 0.080 561 12.0 0 x 0 VNFN wright"soft- 2021-Ja 121321Ai A ...... .vmo R911Sulag Uie 1201919.021 RSUOBt01 Page 1 A= ...\WrigF WAC1WMINEB1JIDUNG-TI-ECOTfAGE. OWc=M.B Fm Door%wv SW Name Grille Size (in) Htg (Cfm) Clg (Cfm) I TEL (ft) Design FR I Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct I Mat I Trunk rb1 Ox0 967 967 0 1 0 0 0 Ox 0 MFx -0ek- wrightsoft® 2021-Jan121321:41 A•.*.•»d—•,�.•., RigitStite®Uriverra1201919.021RSU08101 Paget ...\WngltoftHVAQWYNNEBUIDLING-THECOTTAGE.w Ca1c=NU8 FrortDoorfams.SW