Loading...
HomeMy WebLinkAboutAPPROVED 2124563 RICCIO 2320 OAK DR FT PIERCE FL TDH CALCS (FINAL)(EFILE) Calculations(1)Project No. : 2124563 Project Name : Riccio Residence Project Address : 2320 Oak Dr, Ft Pierce, FL SIMPLIFIED TOTAL DYNAMIC HEAD (TDH) CALCULATIONS WORKSHEET DETERMINE MAXIMUM SYSTEM FLOW RATE : 1. Calculate Pool Volume : Surface area ≔A =⋅12 ft 28 ft 336 ft 2 Average depth ≔d 5 ft ≔V =⋅Ad 12567.272 gal 2. Determine preferred turnover time in hours :≔t =8 hr 480 min 3.Determine Max. Flow Rate :≔Q1 =―V t 26.182 gpm 4. Spa jets : N/A ≔Q2 0 gpm (For single pump pool / spa combo, use the higher of No. 3 or No. 4 in the following calculations for the pool and spa. Calculated flow rate ≔Q =+Round ⎛⎝,max ⎛⎝,Q1 Q2⎞⎠1 gpm⎞⎠1 gpm 27 gpm Allowable flow rate ≔Qmin 36 gpm Actual flow rate ≔Q =max ⎛⎝,QQmin⎞⎠36 gpm Actual turnover time ≔t =―V Q 5.818 hr Florida Engineering LLC  4161 Tamiami Trail, Suite 101, Port Charlotte, FL 33952‐9204  www.flengineeringllc.com | Phone: (941) 391‐5980  License Number #30782, #60102 CRAIG E. GUNDERSON, P.E. #60102 Page 1 of 5 RECOMMENDED MINIMUM PIPE SIZE (2020 FBC, 7TH EDITION) : Branch Piping to be : 2"to keep velocity @ 6fps max at =Q 36 gpm Trunk Piping to be : 2"to keep velocity @ 8fps max at =Q 36 gpm Return Piping to be : 2"to keep velocity @ 10fps max at =Q 36 gpm Page 2 of 5 SIMPLIFIED TDH : 1. Friction loss (in suction pipe) in 2"pipe per ft at =Q 36 gpm ≔fsuction 0.031 2. Friction loss (in return pipe) in 2"pipe per ft at =Q 36 gpm ≔freturn 0.031 3. Length of suction pipe ≔Lsuction 50 ft TDH in suction pipe ≔TDHsuction =⋅Lsuction fsuction 1.55 ft 4. Length of return pipe ≔Lreturn 80 ft TDH in return pipe ≔TDHreturn =⋅Lreturn freturn 2.48 ft 5. TDH in Piping ≔TDHpiping =+TDHsuction TDHreturn 4.03 ft 6. Filter loss in TDH ≔TDHfilter 16.6 ft 7. Heater loss in TDH ≔TDHheater 10.0 ft 8. All other losses ≔TDHother 16.0 ft ...head losses in fittings, etc 9. Total simplidied TDH ≔TDH =+++TDHpiping TDHfilter TDHheater TDHother 46.63 ft Page 3 of 5 Pump Selection using pump curve for simplified TDH and System Flow Rate : Manufacturer : Pentair Model : SuperFlo VS Size / HP = 1.5 Main Drain Cover : Manufacturer : Paramount Model : SDX2 Max. cover flow rate = 188 gpm Cover Replacement Date = 7 years Page 4 of 5 MAIN DRAIN PLUMBING METHOD OPTIONS : Pool A. Dual outlets in parallel one pump B.Dual outlets in parallel to dual pumps in parallel C. Parallel dual outlets to two pumps D. Dual outlets on different planes E.Three or more outlets in parallel symmetric piping F.Three or more outlets in parallel electrically tapped piping G. Three or more outlets in parallel looped piping H.Single unblockable channel outlets to single pump (channel drain @ 316 gpm max. flow rate) I. Single unblockable channel outlets to two pumps (channel drain @ 217 w/2 ports & 278 gpm w/3 ports (see note 4) Notes : 1. In flow suction outlets cover/grate must conform to most recent edition of ASME/ANSI A112.19.8 and be embossed with that edition approval. 2. Pump and Filter make, model and location cannot change without submitting a revised plan TDH worksheet. 3. See manufacturer's specifications for pump curve of specified pump. 4. Contractor to choose main drain plumbing method from the options (A to I) listed above. Page 5 of 5