Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
bldg dept_letter R5_ signed
FL Design Build Inspect CRC1331263|AA26003142|HI10776 Architecture + Construction + Home Inspection 772.321.4500 | frank.liebler@gmail.com BLDG DEPT CORRESPONDENCE | 1 of 1 11/2/21 To: St Lucie County Building Department Re: Sime Residence, permit #2101-0083 See revisions below. 1. The contractor had trouble sourcing the lintels, so I revised the cmu lintels to cast in place beams. See attached beam schedule with highlighted revisions. Thank you, Frank Liebler Owner / Architect / Contractor FL Design Build Inspect Construction + Architecture + Home Inspection CRC1331263 | AA26003142 | HI10776 frank.liebler@gmail.com c 772.321.4500 DocuSign Envelope ID: BF17ABBE-3B79-43B1-AB16-D2B845A319F9 11/2/2021 IDW (in) D (in) TOBBOB NAVDTYPE REINFORCEMENT/ SPEC NOTEB1.1 12 24 11'‐0" 17'‐0" RCB3 #5 T/B, #3 STIRRUP @ 8" O.C.B1.2 12 24 11'‐0" 17'‐0" RCB3 #5 T/B, #3 STIRRUP @ 8" O.C.B1.3a 12 16 11'‐0" 17'‐8" RCB3 #6 T/B, #3 STIRRUP @ 6.5" O.C.B1.3b 12 16 11'‐0" 17'‐8" CAST CRETE 3 #6 T/B, #3 STIRRUP @ 10" O.C.B1.3c 12 16 11'‐0" 17'‐8" CAST CRETE 3 #6 T/B, #3 STIRRUP @ 10" O.C.B1.3d 12 16 11'‐0" 17'‐8" RCB3 #6 T/B, #3 STIRRUP @ 6.5" O.C.B1.4 8 24 11'‐0" 17'‐0" RCB2 #8 T/B, #3 STIRRUP @ 12" O.C. OMIT STIRRUP @ CENTER 8'B1.5 8 24 11'‐0" 17'‐0" RCB2 #8 T/B, #3 STIRRUP @ 12" O.C.B1.6 8 16 5'‐11" 13'‐11" RCB2 #5 T/B, #3 STIRRUP @ 6.5" O.C.B1.7 12 30 11'‐0" 16'‐6" RCB3 #6 T/B, #3 STIRRUP @ 8" O.C.B1.8 12 24 11'‐0" 17'‐0" CAST CRETE 3 #6 T/B, #3 STIRRUP @ 10" O.C.B1.9 8 24 11'‐0" 17'‐0" CAST CRETE 8F24‐1B/1TSPAN OVER FRANG WALLB1.10 8 24 11'‐0" 17'‐0" CAST CRETE 8F24‐1B/1TSPAN OVER FRANG WALLB1.11 8 24 11'‐0" 17'‐0" CAST CRETE 8F24‐1B/1TSPAN OVER FRANG WALLB2.1a 8 16 22'‐10"CAST CRETE 2 #6 T/B, #3 STIRRUP @ 8" O.C.B2.1b 8 16 22'‐10"CAST CRETE 2 #6 T/B, #3 STIRRUP @ 12" O.C.B2.1c 8 16 22'‐10"CAST CRETE 2 #6 T/B, #3 STIRRUP @ 12" O.C.B2.1d 8 16 22'‐10"CAST CRETE 2 #6 T/B, #3 STIRRUP @ 8" O.C.B2.2a 8 16 22'‐10"CAST CRETE 2 #6 T/B, #3 STIRRUP @ 8" O.C.B2.2b 12 16 22'‐10"CAST CRETE 2 #6 T/B, #3 STIRRUP @ 10" O.C.B2.2c 12 16 22'‐10"CAST CRETE 2 #6 T/B, #3 STIRRUP @ 10" O.C.B2.2d 8 16 22'‐10"RCB2 #6 T/B, #3 STIRRUP @ 6" O.C. OMIT STIRRUP @ CENTER 6'B2.3 3" 11.25" 18'‐8.25"WOOD (2) 2x12B2.4 8 16 22'‐10"RCB2 #6 T/B, #3 STIRRUP @ 8" O.C.B3.1a 8 16 33'‐8"CAST CRETE 2 #6 T/B, #3 STIRRUP @ 8" O.C.B3.1b 8 16 33'‐8"CAST CRETE 2 #6 T/B, #3 STIRRUP @ 12" O.C.B3.1c 8 16 33'‐8"CAST CRETE 2 #6 T/B, #3 STIRRUP @ 12" O.C.B3.1d 8 16 33'‐8"CAST CRETE 2 #6 T/B, #3 STIRRUP @ 8" O.C.B3.2c 8 16 33'‐8"CAST CRETE 2 #6 T/B, #3 STIRRUP @ 12" O.C.B3.2d 8 16 33'‐8"CAST CRETE 2 #6 T/B, #3 STIRRUP @ 12" O.C.B3.4 8 16 21'‐6"RCB2 #6 T/B, #3 STIRRUP @ 8" O.C.BOND BEAM816CMU2 CMU COURSES W/ #5 EA COURSEBOND BEAM816RCB 2 #5 T/BBEAM SCHEDULEIF MULTIPLES OF SAME ID, USE EITHERSEE CONNECTOR SCHEDULE FOR WOOD BEAMSDocuSign Envelope ID: BF17ABBE-3B79-43B1-AB16-D2B845A319F911/2/2021