HomeMy WebLinkAboutRock SEAWALL PlanEDGE OF PROPOSED CONCRETE CAP FP-475 VINYL SHEET PILING Allowable Moment 5,467 ft-lb/ft Section Modulus 20.5 In/ft Moment of Inertia 45 in/ft Impact Strength 13,750 in-lbs/I; Thickness 0,250 in, 0,240 in Section Depth 7.0 in Section Width 24 in Material Weatherobte Rigid Vinyl 2'-0" i^IL - KMA ENGINEERING & SURVEYING Seawall Plan View ANCHOR FP-475 x 12' VINYL SHEET PILING APPROX. 507 EMBEDDED Elevation View / APPROX, FINISHED GRADE v n w 3/4' x 8' GALV, TIE -BACK ROD CLEAN FILL z w/ NUTS & 4' x 112' WASHER ` EACH END TYR w RUSHED DRAINAGE ROCK (U EXISTING WOOD SEAWALL-1 I II 18' X 18' X 18' CONCRETE ANCHOR w/ (2) #5 BARS EACH WAY Seawall Section View KMA Engineering & Surveying, LLC Consulting Engineers & Surveyors 80 Royal Patin Pointe, Suite 401 Vero Beach, Fl. 32960 Phone: (772) 569-5505 Fax: (772) 569-1455 E-Mail: civil®kmafl.com Certificate of Authorization Number: 33705 ' x 18' CONCRETE CAP w/1' CHAMFER 4' X 8' #3 HOOP 24' O.C. #5 BAR CONTINUOUS 12 TOP / 2 BOTTOM �2 112' EMBEDDED IN CAP 60 LF, 4' PERF. DRAIN PIPE w/ 4' DRAIN/GRILL AT WALL —APPROX. MHWL I -FP-475 VINYL SHEET PILING 12' PANEL APPROX. 50% EMBED —APPROX, RIVER BOTTOM NOTES: 1. 3,500# CONCRETE PUMP MIX w/FIBERMESH 2. SPONGE FINISH FACE, SURFACE & CHAMFER 3. NEW WALL LOCATED WITHIN 12" OF EXISTING WALL (WETFACE TO WETFACE), AS PER CODE 4. EMBEDDED CONCRETE ANCHORS SHALL NOT INTERFERE WITH PROPOSED POOL SHELL AND DEPTH BELOW GRADE MAY BE ADJUSTED. DATE: DATE= Scott B. McGuire, P.E. David S. Knight, P.E. Fl. Reg No. 39573 Fl. Reg No. 41060 Princess Rock 51 Sovereign Way, Ft. Pierce, FL 34949 CORE General Contractors, Inc. P. O. Box 643711 Vero Beach, FL 32964 772.234.4250 Phone 888.858.1492 Fax