HomeMy WebLinkAboutOverton Residence Garage Final Lift 11.05.21UES Project No:
Workorder No:
Report Date:
3310.2100338.0000
251012-1
11/05/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:Dan Overton UES Technician:Mark Rogers
3406 SW Castkil Drive
Port Saint Lucie, FL 34953
Date Tested:11/05/2021
Project:Overton Residence
5327 N. Old Dixie Hwy, Fort Pierce, St Lucie County, FL 34946
Type of Test:
Area Tested:5327 N. Old Dixie Hwy, Fort Pierce -
Garage Pad - Final Lift
Field:ASTM D-6938 Nuclear Gauge Method
Material:Backfill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Final Grade
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 Center of Garage pad 0-1 ft 114.6 11.1 112.8 10.9 98 Pass
2 Northside of Garage pad 0-1 ft 114.6 11.1 114.0 11.4 99 Pass
Remarks:Permit: 2108-0719
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Josean Andres Duprey Rodriguez, P.E.
STATE OF FLORIDA
Professional Engineer No. 92178
This item has been digitally signed and sealed by Josean Andres
Duprey Rodriguez, P.E. on the date adjacent to the seal. Printed
copies of this document are not considered signed and sealed and
the signature must be verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1