Loading...
HomeMy WebLinkAboutcompactionUES Project No: Workorder No: Report Date: 3360.1800067.0000 251019-1 11/05/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:D. R. Horton America's Builder UES Technician:Johnnie Smith 6123 Lyons Road Coconut Creek, FL 33073 Date Tested:11/05/2021 Project:CMT CREEKSIDE Various Locations, TBD County, FL Type of Test: Area Tested:Lot 78 - 3329 Trinity Circle, Ft. Pierce Field:ASTM D-6938 Nuclear Gauge Method Material:Fill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Final Grade The tests below meet the 98% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 W Side Center 0-1 ft 118.6 10.8 116.9 9.9 99 Pass 2 S Side Center 0-1 ft 118.6 10.8 118.5 10.0 100 Pass 3 E Side Center 0-1 ft 118.6 10.8 117.9 10.3 99 Pass 4 N Side Center 0-1 ft 118.6 10.8 118.7 10.9 100 Pass Remarks: Permit: 2011-0174 Reviewed By GFA International, Inc FBPE Registry No.4930 Josean Andres Duprey Rodriguez, P.E. STATE OF FLORIDA Professional Engineer No. 92178 This item has been digitally signed and sealed by Josean Andres Duprey Rodriguez, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1