Chung, Mark, Hotpie Inc Sealed(1)
CODES AND STANDARDS APPLICABLE CODES AND STANDARDS: NATIONAL ELECTRICAL CODE 2017 ED FLORIDA BUILDING CODE: BUILDING 2020 (7TH ED) FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC) ASCE7-16 NFPA 1 2018 11.12.2.2.2.1 & 11.12.2.2.2.2 INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS (IEEE) NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) NATIONAL FIRE PROTECTION ASSOCIATION (NFPA 70E) UNDERWRITERS' LABORATORIES, INCE (UL) INSULATED CABLE ENGINEERS ASSOCIATION (ICEA) AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) AMERICAN SOCIETY OF TESTING MATERIALS (ASTM) NATIONAL BUREAU OF STANDARDS SAFETY ORDERS OF INDUSTRIAL ACCIDE COMMISSION RULES OF THE NATIONAL BOARD OF FIRE UNDERWRITERS LOCAL ORDINANCES OF THE STATE LOCAL ORDINANCES OF THE COUNTY OR CITY CHUNG, MARK, HOTPIE INC 21.06 kW PV SYSTEM 7469 COMMERCIAL CIR, FORT PIERCE, FL 34951 PROJECT INFORMATION Owner: CHUNG, MARK, HOTPIE INC General Contractor: Installer: GO SOLAR POWER 933 Clint Moore Rd, Boca Raton, FL 33487 (800) 530-9597 Engineer Of Record: Castillo Engineering Services LLC 620 N. Wymore Road, Suite 250 Maitland, FL 32751 (407) 289-2575 Ermocrates E. Castillo License#: FL PE 52590 DRAWING INDEX SHEET # I SHEET DESCRIPTION I REV / ISSUE I DATE PROJECT DETAILS SYSTEM SIZE (AC) (N)15.08kW (E)------------ SYSTEM SIZE (DC) (N) 21.06kW (E)----------- DC/AC RATIO 1.39 SOLAR MODULE MODULE MAKE JINKO MODULE MODEL JKM405M-72HL-V MODULE NAMEPLATE 405W MODULE QTY (N) 52 (E) 31 NUMBER OF TABLES INVERTER INVERTER MAKE ENPHASE INVERTER MODEL (N) ENPHASE IQ7 A , (E) ENPHASE IQ7 INVERTER POWER RATING 290W INVERTER QTY (N) 52 , (E) 31 A-1.0 TITLE SHEET NEW 10-14-2021 A-1.1 GENERAL NOTES & SYMBOLS LEGEND NEW 10-14-2021 S-1.0 SITE PLAN NEW 10-14-2021 S-1.1 ROOF PLAN & MODULES NEW 10-14-2021 S-1.2 PARTIAL PRESSURE AND MODULES EXPOSURE NEW 10-14-2021 S-2.0 STRUCTURAL ATTACHMENT DETAILS NEW 10-14-2021 S-2.1 STRUCTURE CALCULATION NEW 10-14-2021 E-1.0 BRANCH LAYOUT NEW 10-14-2021 E-2.0 INTERCONNECTION AND PROTECTION DIAGRAM NEW 10-14-2021 E-2.1 ELECTRICAL LINE DIAGRAM NEW 10-14-2021 E-2.2 RISER DIAGRAM NEW 10-14-2021 E-3.0 WIRING CALCULATIONS NEW 10-14-2021 E-3.1 GROUNDING DETAILS NEW 10-14-2021 E-4.0 SYSTEM LABELING NEW 10-14-2021 DS-01-05 DATA SHEET NEW 10-14-2021 RACKING RACKING SYSTEM MAKE RACKING SYSTEM MODEL MODULE TILT ANGLE AZIMUTH INTER ROW SPACING VICINITY MAP tl�ILttl1'ul�Cu.nV1.1'� I IRONRIDGE XR10 S-5-PROTEA 9.5° 270° SITE LOCATION 27.470605,-80.405473 dwnile pro x[ Pizrrcce, FL.:. 20 EL Castillo (p Engineering %1.7 SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER GSOLAR POW E R BEN Di itall No. 52� yr12�l- a wl§"led by: Ermocrate =,Fs'.<.oA;e."•G?.'' E Castillo p�S/ON..... Date: 2021.10.2 11:24:38 PROJECT NAME U Z � U � J C7 O Q J = U W LLI LU � W � O0— 0 1- CD `0 O Z �W U SHEET NAME TITLE SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER A-1.0 GENERAL ELECTRICAL AND EQUIPMENT NOTES 1. ALL ELECTRICAL WORK TO BE PERFORMED SHALL 7. TORQUE MARKS SHALL BE PLACED ON ALL CONFORM TO ALL APPLICABLE CODES OF GOVERMENT TERMINATION LUGS USING A COLOR DIFFERENT AGENCIES HAVING JURIDICTIO OVER THE PROJECT. THAN MANUFACTURER. WHERE THESE CODES DO NOT APPLY, THE WORK SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE 2014. 8 ALL EQUIPMENT ANCHORS SHALL BE TORQUED APPLICABLE CODES SHALL INCLUDE BUT NOT BE LIMITED MARKED BASED ON MANUFACTURER'S OR STRUCTURAL ENGINEER'S RECOMMENDATION. TO, THE FOLLOWING: 1.1. NATIONAL ELECTRICAL CODE (NFPA 70), 2014. 9. DC CONDUIT AND RACEWAYS SHALL BE MARKED WITH 1.2. INSTITUTE OF ELECTRICAL AND ELECTRICAL "WARNING: PHOTOVOLTAIC POWER SOURCE" AT 10' ENGINEERS (IEEE). INTERVALS. 1.3. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA). WIRING & WIRING METHODS 1.4. ELECTRICAL SAFETY IN THE WORKPLACE (NFPA 70E) 1.5. UNDERWRITER'S LABORATORY (UL). 1. EXPOSED PV MODULE WIRING SHALL BE TYPE PV WIRE, 1.6. INSULATED CABLE ENGINEERS ASSOCIATION (ICEA). SUNLIGHT (UV) RESISTANT, 90° C, WET RATED ALL EXPOSED CABLES SHALL BE SECURED WITH MECHANICAL 1.7. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). OR OTHER SUN -LIGHT RESISTANT MEANS. 1.8. AMERICAN SOCIETY OF TESTING MATERIALS (ASTM). 2 CONDUCTOR INSULATION VOLTAGE RATING FOR 1000V STRINGS SHALL BE EQUAL OR GREATER 1.9. NATIONAL BUREAU OF STANDARDS. THAN 1000V. 1.10. FBC: BUILDING 2017 3. BENDING RADIUS SHALL BE PROVIDED BASED ON 1.11. SAFETY ORDERS OF INDUSTRIAL ACCIDENT THE NEC. PROPER BENDING RADIUS MUST BE COMMISSION. APPLIED BASED ON CONDUCTOR DIAMETER. 1.12. RULES OF THE NATIONAL BOARD OF FIRE UNDERWRITERS. 4. FIELD WIRING LARGER THAN 6 AWG THAT IS NOT 1.13. LOCAL ORDINANCES OF THE STATE. COLOR CODED SHALL BE COLOR CODED AT BOTH 1.14. LOCAL ORDINANCES OF THE COUNTY OR CITY. ENDS WITH CODING TAPE TO IDENTIFY ITSELF. 1.115. REQUIREMENTS OF LOCAL UTILITY COMPANY. 5. GROUNDED CONDUCTORS SHALL BE COLOR CODED 2. CONTRACTOR SHALL SUBMIT ELECTRICAL EQUIPMENT IN COMPLIANCE WITH NEC ARTICLE 200.6 PRODUCT DATA SHEETS TO ENGINEER FOR REVIEW AND APPROVAL. 6. ALL GROUND CONDUCTORS SHALL BE COPPER, UNLESS NOTED OTHERWISE. 3. PROPOSED DEVIATIONS FROM DESIGN DOCUMENTS SHALL BE REVIEWED AND APPROVED BY ENGINEER. 7. ALL LINE CONDUCTORS SHALL BE COPPER, UNLESS SPECIFICALLY NOTED OTHERWISE ON PLANS. 4. CONTRACTOR SHALL INSTALL ELECTRICAL EQUIPMENT CONTRACTOR SHALL CONFIRM WIRE SIZING WITH IN ACCORDANCE WITH MANUFACTURER'S ENGINEER PRIOR TO USING A WIRE TYPE AND/OR SIZE INSTRUCTIONS. DIFFERENT THAN WHAT IS SHOWN ON THESE PLANS 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ELECTRICAL UTILITY LINES 8. ALL CONNECTORS SHALL BE TORQUED PER DEVICE WHICH ARE TO REMAIN IN USE DURING CONSTRUCTION. LISTING OR MANUFACTURER'S RECOMMENDATIONS. 6. ALL MAJOR EQUIPMENT INTENDED FOR USE IN THE PV SYSTEM SHALL BE IDENTIFIED AND LISTED FOR THE APPLICATION. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL EXISTING UNDERGROUND EQUIPMENT THROUGHOUT THE JOBSITE TO ENSURE THEY ARE PROTECTED IN PLACE. 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THEIR EMPLOYEES, PERSONNEL, SUBCONTRACTORS, AND EQUIPMENTS CONTINUOUSLY DURING ALL TIMES DURING CONSTRUCTION, INCLUDING AFTER HOURS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IMPLEMENT ADEQUATE SAFETY MEASURES AND TO ENFORCE THOSE MEASURES. IDENTIFICATION/MARKINGS 9. WHERE NECESSARY TO PREVENT PHYSICAL DAMAGE TO RACEWAY OR CABLE, UNDERGROUND INSTALLATIONS SHALL HAVE BACKFILL PROTECTION IN THE FORM OF GRANULAR OR SELECTED MATERIAL, OR OTHER APPROVE MEANS. 10. EDGE PROTECTION MUST BE PRESENT IF A CONDUCTOR HAS A POTENTIAL OF BEING DAMAGED. 11. DIRECT -BURIED CONDUCTORS MUST BE PROTECTED FROM EARTH MOVEMENT AT ALL TRANSITIONS FROM CONDUIT TO DIRECT BURIAL VIA BELL ENDS, OAE, PER NEC 300.5. 12. PROPERLY COAT WIRES AND CABLES WITH PULLING COMPOUND BEFORE PULLING INTO CONDUITS AND PREVENT MECHANICAL DAMAGE TO CONDUCTORS DURING INSTALLATION. 13. ALL CAT 5 OR CAT 6 CABLES SHALL BE SHIELDED AND CONTAIN SHIELDED TERMINATION ENDS. 1. CONTRACTOR MUST SUPPLY ALL REQUIRED SAFETY SIGNS AND LABELS, WHICH SHALL BE PERMANENTLY 14. SPARE CONDUITS SHALL BE CAPPED, TAGGED WITH ATTACHED BY MECHANICAL MEANS. LABELS SHALL DESTINATION MARKER, AND PULL WIRES SHALL BE IN COMPLY WITH NEC ARTICLE 690 AND 705.12, AND OTHER PLACED WITH A MINIMUM OF 250LBS TENSILE APPLICABLE LOCAL CODES. STRENGTH. 2. INVERTER IDENTIFICATION MARKINGS SHALL INDICATE 15. CONDUIT CONNECTORS SHALL BE WATER -TIGHT, INVERTER NUMBER AND BE PLACED ON THE FRONT OF COMPRESSION STYLE FITTINGS. THE INVERTER ENCLOSURE. 3. CONTRACTOR SHALL ASSIGN TO EACH WIRE AND CABLE GROUNDING A UNIQUE IDENTIFICATION NUMBER, NUMBERS SHALL BE ASSIGNED TO ALL CONDUCTORS HAVING COMMON 1. A GROUNDING ELECTRODE SYSTEM SHALL BE TERMINALS. PROVIDED. UNLESS OTHERWISE NOTED. 4. AT A MINIMUM, IDENTIFICATION NUMBERING SHALL 2. EXPOSED NON -CURRENT CARRYING METAL PARTS INCLUDE ORIGIN LOCATION & TERMINAL LOCATION. SHALL BE GROUNDED. 5. APPLY ALL CONDUCTOR AND CABLE MARKERS BEFORE 3. EQUIPMENT GROUNDING CONDUCTOR SHALL BE TERMINATION. SIZED IN ACCORDANCE WITH NEC 250.1222. 6. APPLY ALL CONDUCTORS IDENTIFICATION MARKING 4. WHERE GROUNDING ELECTRODE WITH HEAT SHRINKABLE TUBING. TUBING SHALL BE CONDUCTORS ARE SPLICED THEY SHALL BE TIGHT ON THE WIRE AFTER INSTALLATION AND IRREVERSIBLE. CHARACTERS SHALL FACE THE OPENING PANEL AND READ LEFT TO RIGHT OR TOP TO BOTTOM. ELECTRICAL ABBREVIATIONS ELECTRICAL SYMBOLS AF AMPERES FRAME OF PNLBD PANEL BOARD DISCONNECT BREAKER POI POINT OF INTERCONNECTION AIC AMPS INTERRUPTING PRI PRIMARY CIRCUIT BREAKER CAPACITY PS PRESSURE SWITCH AMP,A AMPERES PT POTENTIAL TRANSFORMER INVERTER AT AMPERES TRIP RATING OF PV PHOTOVOLTAIC BREAKER PVC POLYVINYL CHLORIDE FUSE W / CURRENT RATING AUTO AUTOMATIC PWR POWER ATS AUTOMAT TRANSFER REC RECEPTACLE PV MODULE SWITCH RECPTS RECEPTACLES AUX AUXILIARY REQD REQUIRED O METER AWG AMERICAN WIRE GAUGE SCH SCHEDULE BKR BREAKER SECT SECTION T CONTRACTOR C CELSIUS SHT SHEET 1 CAB CABINET SIG SIGNAL I MOV LIGHTING ARRESTOR CB COMBINER BOX SM START CONTACTOR COIL = CC CENTER TO CENTER SP HTR SPACE HEATER 1 EARTH GROUND CKT CIRCUIT ST SHUNT TRIP CND COM CONDUIT COMMUNICATION STA STATION \/ _I THREE PHASE WYE CONNECTED CPT CONTROL POWER STD STL STANDARD STEEL SOLIDITY GROUNDED NEUTRAL TRANSFORMER STIR STRING THREE PHASE DELTA CONNECTED CR CONTROL RELAY SW SWITCH (MAGNETICALLY HELD SWBD SWITCHBAORD POTENTIAL TRANSFORMER UNLESS NOTED OTHERWISE) SWGR SWITCHGEAR CT CONTROLTRANSFORMER SYS SYSTEM E_ CURRENT TRANSFORMER CTRL CONTROL SYM SYMMETRICAL CU COPPER TDOD TIME DELAY ON IT I TRANSFORMER DAS DATA ACQUISITION SYSTEM DE-ENERGIZATION DB DIRECT BURIAL TEPM TEMPERATURE CX COMBINER BOX DISC DISCONNECT TERM TERMINAL DISTR DISTRIBUTION TKR TRACKER OJB X JUNCTION BOX DWG DRAWING TS TAMPER SWITCH EGC EQUIPMENT GROUND TSTAT THERMOSTAT BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS CONDUCTOR TYP TYPICAL SURFACE MOUNTED ELEV ELEVATION U/G UNDERGROUND EMERG EMERGENCY UNO UNLESS NOTED OTHERWISE BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS ENCL ENCLOSURE UGPS UNDERGROUND PULL FLUSH MOUNTED EQPT EQUIPMENT SECTION (E) EXISTING VOC OPEN CIRCUIT VOLTAGE BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS FDR FEEDER W WATTS SURFACE MOUNTED FS FLOW SWITCH WHM METER (WATT HOUR METER) FLEX FLEXIBLE WP WEATHERPROOF BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS FUT FUTURE XFMR TRANSFORMER FLUSH MOUNTED FUP FUSE, CPT PRIMARY #8 BRANCH CIRCUIT CONDUIT CONCEALED FUS FUSE, CPT SECONDARY GEC GROUND ELECTRODE ABOVE CEILING OR IN WALL. CONDUIT CONDUCTOR SHALL INCLUDE PHASE, NEUTRAL AND GND GROUND G N PHASES GROUND CONDUCTORS AS REQUIRED FOR HH HAND HOLE CIRCUITS (UNLESS OTHERWISE NOTED HOA HAND -OFF -AUTOMATIC HTR HEATER BRANCH CIRCUIT CONDUIT CONCEALED IN HZ HERTZ SLAB, UNDERGROUND OR UNDER FLOOR. IG ISOLATED GROUND ID INDICATION UP CONDUIT TURNING UP ISTR INSTRUMENT INV. INVERTER DN CONDUIT TURNING DOWN ISC. SHORT CIRCUIT CURRENT JB JUNCTION BOX 7 CONDUIT STUB k THOUSAND (KILO) kV KILOVOLTS CONDUIT CONTINUED kW KILOWATTS kVA KILOVOLT AMPERES %-- FLEXIBLE CONDUIT kVAR KILOVOLT AMPERES REACTIVE EXISTING TO REMAIN KWH KILOWATT-HOUR KWHD KILOWATT HOUR DEMAND METER LC LOAD CENTER LT, LTS LIGHT, LIGHTS LGT LIGHTING MAX MAXIMUM MET METEOROLOGICAL STATION MCB MAIN CIRCUIT BREAKER MCM,Kcmil THOUSAND CIRCULAR MILS MH MANHOLE MLO MAIN LUG ONLY MIN MINIMUM MT MOUNT MTD MOUNTED MTG MOUNTING NO,NOS NUMBER,NUMBERS NP NAME PLATE NTS NOT TO SCALE OC ON CENTER PB PULL BOX PCs POWER CONVERSION STATION PLC PROGRAMMABLE LOGIC CONTROLLER PNL PANEL Castillo ((p Engineering %1.7 SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER AOL- GSOLAR POW E R BEN Di itall No. 52efgnajar wi§gnIed by: pEt STATE OF .:4j- Ermocrate 1�F3 •,<oe��PG2.`�` E Castillo SOS/ONA116N50 Date: 2021.10.2 11:24:38 PROJECT NAME U z W Lo U J C'7 O Q J = U LL LLI W W_ 0 0 CD (0O Z LL U SHEET NAME LEGEND SHEET & GENERALNOTES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER A-1.1 MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = (N) 52 MODULES MODULE TYPE = JINKO: JKM405M-72HL-V (405W) MODULES MODULE WEIGHT = 49.60 LBS / 22.5 KG. MODULE DIMENSIONS = 79.06" x 39.45" = 21.66 SF UNIT WEIGHT OF ARRAY = 2.29 PSF N w B 1 S ARRAY #2 (31) EXISTING MODULES (N) (52) ENPHASE: ENPHASE IQ7 A MICROINVERTERS ARRAY #1 (N) (52) JINKO: JKM405M-72HL-V (405W) MODULES (N) SOLADECK 1 SITE PLAN S-1.0 SCALE: 1/32" = V-0" COMMERCIAL CIR, 231'-5" -7 EXISTING o) DRIVEWAY 115'-5" 2-STORY BUILDING CV I I CV OI I N I . . 29'-0" M 231'-5" 3/4" IMC, RMC, FMC, LFMC, PVC, (E) SERVICE POINT AND UTILITY METERING HDPE, NUCC, RTRC, LFNC, FMT, (E) MAIN SERVICE DISCONNECT/MAIN ENT OR EMT CONDUIT RUN DISTRIBUTION PANEL (N) ALTERNATIVE POWER SOURCE AC DISCONNECT (31) EXISTING ENPHASE IQ7 (N) SUBPANEL MICROINVERTERS - ZONING SETBACK - 2 FT Castillo p Engineering SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER 54PSOLAR POW F No. *�Bfgrizjdre WI!§iyiIed by: Ermocrate 'y9O�. gTATE OF .�; E Castillo Date: 2021.10.2 11:24:39 PROJECT NAME U Z W � � � U � .J C'7 O Q J = U LL LLI W W Oa- H CD CO O Z ti ILL 2 U SHEET NAME SITE PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER S-1.0 MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = (N) 52 MODULES MODULE TYPE = JINKO: JKM405M-72HL-V (405W) MODULES MODULE WEIGHT = 49.60 LBS / 22.5 KG. MODULE DIMENSIONS = 79.06" x 39.45" = 21.66 SF UNIT WEIGHT OF ARRAY = 2.29 PSF rn 4 ROOF #1 TILT - 9.5° AZIM.-270' 4' FIRE ACCESS PATHWAY 87'-0" - ARRAY AREA & ROOF AREA CALC'S ROOF ARRAY ROOF ROOF ROOF TYPE AREA AREA AREA TILT AZIMUTH TRUSS SEAM (sq.Ft.) (Sq. Ft.) COVERED BY SIZE SPACING ARRAY N (N) #1 METAL 1126.32 6525.00 17.26 9.5 270° 2"X4" 16" O.C. (E) #2 METAL ----- 6525.00 ----- 9.5 90, 2"X4" 16" O.C. 1 GENERAL INSTALLATION PLAN NOTES: 1) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED AS SHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE: WIND ZONES NON - EXPOSED SPAN 2'-8" MODULES CANTILEVER 0'-11" EDGE / EXPOSED SPAN 1'-4" MODULES CANTILEVER 0'-5" ZONE ZONE 1' X X X X ZONE2e 2'-8" 0'-11.. 1'-4" 0'-5" ZONE2n 1'-4" 0'-5" 1'-4" 0'-5" ZONE2r 1'-4" 0'-5" 1'-4" 0'-5" ZONE3e 1'-4" 0'-5" 1'-4" 0'-5" ZONE 3r 1'- 4" 0' - 5" N/A N/A SEE SHEET S-2.1 FOR SUPPORTING CALCULATIONS. 2) EXISTING COMMERCIAL BUILDING HAVE 2"X4" SYP TRUSSES SPACED @ 24" O.C. AND METAL ROOF DECKS WITH MEAN ROOF HEIGHTS OF 25 FT WITH SEAMS SPACED 16" O.C. EXISTING ROOF SLOPE FOR THE SOLAR RETROFIT IS 9.5 DEGREES. CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANS AND IN FIELD CONDITIONS. 3) FIRE SETBACK TO BE 4' FROM EDGES, PER NFPA 1 2018, 11.12 I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE WITH FBC 2020 (7TH ED): COMMERCIAL CHAPTER 16. BUILDING STRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFT WIND LOADS AND EQUIPMENT DEAD LOADS. , ■ - • • ARRAY #2 (148) PV ROOF ATTACHMENT (31) EXISTING MODULES @ 16" & 32" O.C. MAX. ■ ■ LEGEND (SEE SHEET S-2.0 FOR ■ ■ ATTACHMENT DETAIL) ■ (31) EXISTING ENPHASE IQ7 -WIND ZONE 1 (TYP) • MICROINVERTERS (SEE SHEET S-1.2 FOR PARTIAL Z.• PRESSURE OF THE MODULE) • • - WIND ZONE 2e (TYP) (N) IRONRIDGE XR10 (TYP.) ■ ■ - WIND ZONE 2n (TYP) ■ ■ - WIND ZONE 2r (TYP) (N) (52) ENPHASE: ENPHASE IQ7 A • • MICROINVERTERS • • - WIND ZONE 3r (TYP) ARRAY #1 • • - WIND ZONE 3e (TYP) (N) (52) JINKO: JKM405M-72HL-V ■ ■ (405W) MODULES • • ROOF PLAN & MODULES ������ . S-1.1 SCALE: 1/16" = V-0" R R"TYP _ ----------- Castillo gi((� Enneering 1.r� SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407)289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER G OSOLAR POW E R EAST/` `o'' 'Di itall BEN No. 52�yf12�l1fe Wlyi"led by: Ermocrate 1�F3 •,<oe��PG2.`�` E Castillo �O S/ON..... 0 Date: 2021.10.2 11:24:39 PROJECT NAME U Z w � U � J C7 O Q J = U LL LLI W � w O� H CD `0 O Z ILL U SHEET NAME ROOF PLAN & MODULES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER S-1.1 N �n_e' FOR EXPOSED MODULES 1 1 1' 2e 2n 2r 3e 3r 66.4 1 0 66.4 85.1 85.1 85.1 100.1 Module Size 1 21.66 Sq. ft. Exposed modules Partial 1 1' 2e 2n 2r 3e 3r Pressure P1 21.66 0 0 0 0 0 0 66.40 FOR NON -EXPOSED MODULES 1 1' 2e 2n 2r 3e 3r 44.3 1 0 1 44.3 1 56.7 56.7 56.7 66.8 Module Size 21,667 Sq. ft. Non -Exposed modules Partial 1 1' 2e 2n 2r 3e 3r Pressure P2 21.66 0 0 0 0 0 0 44.30 ALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS: 75 PSF �2 STING MODULES 2h2 DISTANCE: 0'- 10" 0.5h DISTANCE: 12' - 6" NOTE: PARTIAL PRESSURES OF THE WIND ZONES ON ALL MODULES HAVE BEEN VERIFIED AND ARE WITHIN THE ALLOWABLE PER THE MANUFACTURER SPECIFICATION, INSTALLER SHOULD FOLLOW THE LAYOUT TO AVOID HIGHER ZONAL PARTIAL PRESSURES. ANY CHANGES IN LAYOUT SHOULD BE REPORTED BACK TO THE ENGINEER OF RECORD. LEGEND ® - EXPOSED MODULE - EDGE MODULE 0 - NON- EXPOSED MODULE - MISSING MODULE - MIN. MODULE EDGE DISTANCE LINE --- - MODULE EXPOSURE LINE - WIND ZONE 1 (TYP) - WIND ZONE 2e (TYP) - WIND ZONE 2n (TYP) - WIND ZONE 2r (TYP) - WIND ZONE 3r (TYP) - WIND ZONE 3e (TYP) Castillo p Engineering SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER SOLAR P*W E P F.._ Di itall No. 52s30.Jna Ore wl!�i"led by: E Ermocrate y9p:, ernrE of :�u: E Castillo Date: 2021.10.2 11:24:40 PROJECT NAME U Z W Lo � U � J C7 p aJ = U LL �w w � �w � O0- H CD `0 O Z ILL U SHEET NAME PARTIAL PRESSURE AND MODULES EXPOSURE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER S-1.2 LEFT VIEW FRONT VIEW RIGHT VIEW 1 ATTACHMENT DETAIL S-02 SCALE: NTS (N) END CLAMP ALUMN. "L" BRACKET W1318" SS BOLT & NUT F— (N) IRONRIDGE XR10 RAIL (TYP.) (N) MID CLAMP PV MODULE h2 uI 16" SEAM SPACE i1IIV�'. -we 1, ,I' FOR STANDING SEAM SPECIFIC MECHANICAL LOAD TEST INFORMATION AND CLAMP INSTALLATION INFORMATION PLEASE VISIT: WWW.S-5.COM (N) PROTEA BRACKET Castillo ((-zk Engineering %1.7 SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407)289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER G SOLAR POW E R BEN '°�E.AST„`o' Di itall No. s2efgnaj4re wik i"led by: p'.. STATE of : � Ermocrate E Castillo p�S/ONA�16N�0 Date: "'n.... 2021.10.2 11:24:40 PROJECT NAME U Z W � � � U � J C'7 O Q J = U LL LLI W W O� H CD `D O Z LL. 2 U SHEET NAME ATTACHMENT DETAIL (N) STAINLESS STEEL LSCREWS SHEET SIZE 2 ATTACHMENT DETAIL &ENLARGED VIEW (N) PROTEA BRACKET (E) STANDING SEAM ANSI B 11" X 17" S-02 SCALE: 1" = 1'-0" SHEET NUMBER S-2.0 250 150 1}30 120 1 140 , 1..... Net- 1. Values are ekin>t desldn 3-sacend dust w)nd speeds in wiles per hour (a/s) at 33 ft (14w) above ground for Exposure t cat- to*"- 2. Linear int-pelatio, hwt- cont-. is permitted. 3. ideals and coastal areas outside the last centaur shall use the last wind speed contour of the coastal aces. 4. meuntaineus terrain, derdes, oceen reao pt-lea, and special wind regions shall be exam-d far unuswi vied condi- tions. S. [rind speeds correspond to approximately a 7% probability of exceedance in SO years (A.." f-Awnce Rabability = 0.9n43, Mal a lam years). r mm u. 170 we 180\ aw s e a.e r FIGURE 1609.3(1) ULTIMATE DESIGN WIND SPEEDS, VuLT, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES WIND LOAD CALCULATIONS FOR MODULES INSTALLED ON ROOFS WITH A HEIGHT LESS THAN 60, SITE INFORMATION FBC VERSION 2020 RISK CATEGORY II MEAN ROOF HEIGHT (ft) 25.0 EXPOSURE CATEGORY C ROOF LENGTH (ft) 150.0 ROOF SLOPE 2 /12 ROOF WIDTH (ft) 87.0 ROOF SLOPE (°) 9.5 PARAPET HEIGHT (ft) 0.0 ROOF TYPE GABLE MODULE LENGTH (in) 79.06 ULTIMATE WIND SPEED 160 mph MODULE WIDTH (in) 39.45 NOMINAL WIND SPEED 124 mph MODULE ORIENTATION PORTRAIT EXPOSURE FACTOR (Ce) 1.000 MODULE AREA (sq.1L) 21.66 TEMPERATURE FACTOR (Ct) 1.000 GROUND SNOW LOAD (psf) 0.0 IMPORTANCE FACTOR (Is) 1.000 DEAD LOAD (psf) 3.0 SLOPE FACTOR (C9) 0.910 SLOPED ROOF SNOW LOAD (psf) 0.0 Kp 0.850 EFFECTIVE WIND AREA (ft2) 21.7 Kzj 1.000 GROUND ELEVATION (ft) 18.0 Ke 0.999 HVHZ NO KZ 0.945 DESIGN CALCULATIONS VELOCITY PRESSURE (q) = .00256*KEKZKzTKpV2 VELOCITY PRESSURE(ASD) 31.6 psf TH OF PRESSURE COEFFICIENT 87' * 10% = 8.7' ZONE WIDTH A 8.7 FT 25' * 40% = 10, ZONE 2 WIDTH N/A (FOR (°) < 7°) ZONE 3 WIDTH N/A (FOR (°) < 7°) EXTERNAL PRESSURE COEFFICIENT ZONE 1 0.456 -1.926 ZONE 1' X X ZONE 2e 0.456 -1.926 ZONE 2n 0.456 -2.520 ZONE 2r 0.456 -2.520 ZONE 3e 0.456 -2.520 ZONE 3r 0.456 -2.996 INTERNAL PRESSURE COEFFICIENT f+/- 0.18 DESIGN PRESSURES ROOFZONE DOWN UP 1 20.1 -66.5 psf 1' X X psf 2e 20.1 -66.5 psf 2n 20.1 -85.2 psf 2r 20.1 -85.2 psf 3e 20.1 -85.2 psf 3r 20.1 -100.3 psf Y EDGE FACTOR (EXPOSED) 1.5 Y EDGE FACTOR (NON -EXPOSED) 1 Module allowable uplift pressure Module allowable down pressure SOLAR PANEL PRESSURE EQUALIZATION FACTOR 1 16.0 -66.4 -44.3 psf 1' X X X psf 2e 16.0 -66.4 -44.3 psf 2n 16.0 -56.7 psf 2r 16.0 -56.7 psf 3e 16.0 -56.7 psf 3r 16.0 -66.8 psf ATTACHMENTS USED ATTACHMENT MODEL S-5 prof a ATTACHMENT STRENGTH 422 MAX DESIGN LOADS ALLOWABLE LIMIT MAX SPAN TO N/A in RAFTER/SEAM SPACING 16 in NO. OF RAILS ROOF ZONE DOWN UP (Exposed) UP (N. Exposed) 1 140.6 291.6 388.8 Ibs 1' X X X Ibs 2e 140.6 291.6 388.8 Ibs 2n 70.3 373.9 249.3 Ibs 2r 70.3 373.9 249.3 Ibs 3e 70.3 373.9 249.3 Ibs 3r 70.3 293.2 Ibs 75 psf 75 psf 0.66574 Ibs d: 2 Non. Exp: 2 SPANS (E) SPANS (N.E) 16 in 32 in X in X in 16 in 32 in 16 in 16 in 16 in 16 in 16 in 16 in 16 in 16 in Castillo Engineering SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER .SOLAR EAN *; No. *z$3lgnallewiMy9led by: o:. STATE OF ; Ermocrate E Castillo Date: 2021.10.2 11:24:40 PROJECT NAME U z LU � U � J 00 O Q J = U LL 0' LLI W W H- (Do z ti LL U SHEET NAME STRUCTURE CALCULATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER S-2.1 CHUNG, MARK, HOTPIE INC (NEW) (02) BRANCHES OF 11 MODULES (03) BRANCHES OF 10 MODULES (EXISTING) (01) BRANCH OF 11 MODULES (02) BRANCHES OF 10 MODULES BRANCH #1 (11 MODULES) BRANCH #2 (11 MODULES) BRANCH #3 (10 MODULES) BRANCH #4 (10 MODULES) BRANCH #5 (10 MODULES) BRANCH #2 BRANCH #4 BRANCH #5 BRANCH #3 1 BRANCH LAYOUT E-1.0 SCALE: 1/16" = 1'-0" U"l 11111 1 t I MC, RMC, FMC, LFMC, PVC, NUCC, RTRC, LFNC, FMT, DR EMT CONDUIT RUN Castillo ((� Engineering k . SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER SOLAR No. —8fg g,1je WIJiy9Ied by: Ermocrate 'y9O�. gTATE OF .�; E Castillo Date: 2021.10.29 11:24:41 PROJECT NAME U z W_ � U � J M O Q J = U H LLi Y LLI U Q 2 LLI 0 a_ H z ° U SHEET NAME BRANCH LAYOUT SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-1.0 FROM UTILITY EXISTING, NOT IN SCOPE UTILITY TRANSFORMER 7 (N) ALTERNATIVE POWER SOURCE AC DISCONNECT: 208V, 200AMP RATED NEMA 3R, UL LISTED LOCKABLE & FUSIBLE WITH 150A FUSES BI-DIRECTIONAL UTILITY METER 3-PHASE, 208V (E) 125A ENPHASE IQ [WITHUBINER O(4) 1 INTERCONNECTION AND PROTECTION DIAGRAM (X-IQ-AM1-240-3) [WITH UPTO (4) 2-POLE BREAKERS AND ENVOY COMMUNICATION GATEWAY] E-2.0 SCALE: N.T.S Castillo ((� Engineering k . SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407)289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER GOSOLAR POW F BEN Digitally No. 52efgdajar §"led by: p, STATE OF :�� Ermocrate �6�a��p•�oe��PG2.'' E Castillo '�iS�ONA�16N"` Date: "'n.... 2021.10.29 11.24.41 PROJECT NAME U z W_ �Lo � U � J C'7 Q Q J = UH LLLI LI U Q 2w 0� rn� c� z �O LL 2 U SHEET NAME INTERCONNECTION AND PROTECTION DIAGRAM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-2.0 r Q CABLES Q CABLES 46 BARE CU WIRE PROTECTED PER NEC 250.64(B) --------------- B3 2 Q CABLES --- I &pq 11 E� 1� E� 1� e �j e �j &p� t �j E� 1� e �� ti ti ti ti ti ti ti ti _�c X-, x I x I x I x I x I X-, (3) #10 AWG THWN-2 - RED (2) #10 AWG THWN-2 - RED (N) (02) SOLADECK (3) #10 AWG THWN-2 -BLACK (2) #10 AWG THWN-2 - BLACK 600V, NEMA 3R EGC #10 AWG THWN-2 EGC #10 AWG THWN-2 c 2 u L2 u c L2 u 2 u L2 a UL LISTED IN 3/4" PVC, IMC, RMC, FMC, IN 3/4" PVC, IMC, RMC, FMC, LFMC, HDPE, NUCC, RTRC, LFMC, HDPE, NUCC, RTRC, 2 u 2 u c 2 u 2 u 2 u LFNC, EMT, FMT OR ENT LFNC, EMT, FMT OR ENT CONDUIT RUN CONDUIT RUN L_ - - - - - - - - L------------ (3) #10 AWG THWN-2 - RED (3) #10 AWG THWN-2 - BLACK EGC #10 AWG THWN-2 IN 3/4" PVC, IMC, RMC, FMC, LFMC, HDPE, NUCC, RTRC, LFNC, EMT, FMT OR ENT CONDUIT RUN 1 1 - - - - - - - 15A/3P (4) #6 AWG THWN-2 (1) #6 AWG THWN-2 GND IN 1" PVC, IMC, RMC, FMC, LFMC, HDPE, NUCC, RTRC, LFNC, EMT, FMT, ENT CONDUIT RUN (E) 125A ENPHASE IQ COMBINER 3 (X-IQ-AM1-240-3) [WITH UPTO (4) 2-POLE BREAKERS AND ENVOY COMMUNICATION GATEWAY] ENPHASEIQ7 MICROINVERTERS PV MODULES ENPHASE: ENPHASE IQ7 A MICROINVERTERS PV MODULES (N) 200A SOLAR SUB PANEL (NEW) SOLAR ARRAY (21.060 kW -DC STC) (52) JINKO: JKM405M-72HL-V (405W) MODULES (02) BRANCHES OF 11 MODULES (03) BRANCHES OF 10 MODULES EXISTING SOLAR ARRAY (31) PV MODULES (01) BRANCH OF 11 MODULES (02) BRANCHES OF 10 MODULES NOTE: 1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEC 2017, AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURER AND MODEL NUMBER, AS APPLICABLE. 2.ALL PANELS DOWNSTREAM OF LOAD SIDE INTERCONNECTION TO BE PROTECTED BY A PRE-EXISTING OR AN ADDITIONAL OCPD SIZED PER NEC 408.36. INTERCONNECTION 120% RULE - NEC 705.12(B)(2)(3)(b) UTILITY FEED + SOLAR BACKFEED TO UTILITY GRID 200A + 150A = 350A BUSS RATING x 120% �Ll L2 L3 N 600A x 120% = 720A BI-DIRECTIONAL SERVICE POINT AND UTILITY METERING e (N) ALTERNATIVE 3-PHASE, 208V POWER SOURCE T7TT AC DISCONNECT: 208V, 200AMP RATED NEMA 3R, UL LISTED LOCKABLE & FUSIBLE L1 L2 L3 N F O c O 20A/3P 20A/2P (4) #1/0 AWG THWN-2 ENVOY (1) #6 AWG THWN-2 GND IN 1-1/2" PVC, IMC, RMC, FMC, 20A/2P LFMC, HDPE, NUCC, RTRC, LFNC, EMT, FMT, ENT CONDUIT RUN 20A/2P (3) #10 AWG THWN-2 (1) #10 AWG THWN-2 GN D 20A/2P IN 3/4" PVC, IMC, RMC, FMC, LFMC, HDPE, NUCC, RTRC, — LFNC, EMT, FMT, ENT CONDUIT RUN (E) MAIN BREAKER 200A/3P,208V Id EXISTING G GROUNDING ELECTRODE (E) MAIN SERVICE DISCONNECT/ SYSTEM MAIN DISTRIBUTION PANEL, - 600A RATED 3-PHASE, 208V 1 ELECTRICAL LINE DIAGRAM E-2.1 SCALE: NTS Castillo ((� Engineering k . SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407)289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER GOSOLAR POW F °E BAST/``o'' Di itall BEN •. ` No. s2etnaj4re wi§gnIed by: r? of :� Ermocrate E Castillo .q��pNA11 i,� Date: 2021.10.29 " ° 11-24-42 PROJECT NAME U Z w Lo U J C7 Q Q _J LL LLi QC 2 LLI G G rn cy) V CO O Z ti U SHEET NAME ELECTRICAL LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-2.1 METER O MAIN PANEL 600A AMP 3 PHASE FROM FPL NOTES: RISER DIAGRAM 120/208 VOLT 600AMP 3 PHASE (3) #10 AWG THWN-2 - RED (3) #10 AWG THWN-2 - BLACK EGC #10 AWG THWN-2 — IN 3/4" PVC, IMC, RMC, FMC, LFMC, HDPE, NUCC, RTRC, LFNC, EMT, FMT OR ENT CONDUIT RUN (4) #1/0 AWG THWN-2 (1) #6 AWG THWN-2 GND IN 1-1/2" PVC, IMC, RMC, FMC, LFMC, HDPE, NUCC, RTRC, LFNC, EMT, FMT OR ENT CONDUIT RUN (N) ALTERNATIVE POWER SOURCE AC DISCONNECT:208V, 200AMP, RATED NEMA 3R,UL LISTED LOCKABLE & FUSIBLE WITH 150A FUSES 1. BONDING & GROUNDING OF BREAKER PANELS TO BE FACTORY INSTALLED. 2. ALL CONDUCTORS TO BE COPPER, 600V, THWN-STRANDED 1 RISER DIAGRAM E-2.2 SCALE: NTS TO SOLAR TO SOLAR ARRAY ARRAY ENPHASEIQ LIL SOLAR COMBINER 3 SUBPANEL (4) #6 AWG THWN-2 (1) #6 AWG THWN-2 GND IN 1" PVC, IMC, RMC, FMC, LFMC, HDPE, NUCC, RTRC, LFNC, EMT, FMT, ENT CONDUIT RUN (3) #10 AWG THWN-2 - RED (3) #10 AWG THWN-2 - BLACK EGC #10 AWG THWN-2 IN 3/4" PVC, IMC, RMC, FMC, LFMC, HDPE, NUCC, RTRC, LFNC, EMT, FMT OR ENT CONDUIT RUN COORDINATE WITH ELECTRICAL UTILITY COMPANY PRIOR TO START OF CONSTRUCTION FOR UTILITY METER REQUIREMENTS, PLANNING AND SCHEDULING Castillo ((� Engineering k . SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER ,4SOLAR POWF No. SE��fle�l$e wi!§ iy9ledby: '* c VO'. STATE OF Ermocrate 'y9O�.�; E Castillo Date: 2021.10.29 11:24:42 PROJECT NAME U z W_ U J M O Q J = U H LLi Y Lu U Q 2 Lu a_ H z ° U SHEET NAME RISER DIAGRAM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-2.2 ELECTRICAL CALCULATION Array To Combiner Box Voltage Voltage Original berated Ground Terminal Conductor Wiring Sets of Max Max Numberof Conduit Fill Height Ambient Temperature Drop Conductor Original Drop Conductor Voltage Branch Wire Run Strings Wire Rating Length Conductor Conductor Conductor OCPD Rating Material Configuration wires Current Voltage conduits Derate Above Roof Tempeture Derate Corrected Ampacity EGC Corrected Type Drop Size Ampacity Material Conductor EGC (E) Branch - 1 11 75 90 CU 35 2 1 15.81 208 1 1 Free Air 34 0.96 #10 #10 55 52.8 CU #10 #10 20 PV WIRE 0.6439% (E)Branch-2 10 75 90 CU 70 2 1 14.38 208 1 1 Free Air 34 0.96 #10 #10 55 52.8 CU #10 #10 20 PV WIRE 1.1707% (E)Branch-3 10 75 90 CU 50 2 1 14.38 208 1 1 Free Air 34 0.96 #10 #10 55 52.8 CU #10 #10 20 PV WIRE 0.8362% Branch (N) Branch - 1 11 75 90 CU 35 2 1 19.11 208 1 1 Free Air 34 0.96 #10 #10 55 52.8 CU #10 #10 20 PV WIRE 0.7783% #1 - #8 (N) Branch - 2 11 75 90 CU 70 2 1 19.11 208 1 1 Free Air 34 0.96 #10 #10 55 52.8 CU #10 #10 20 PV WIRE 1.5566% (N)Branch-3 10 75 90 CU 50 2 1 17.38 208 1 1 Free Air 34 0.96 #10 #10 55 52.8 CU #10 #10 20 PVWIRE 1.0108% (N)Branch-4 10 75 90 CU 85 2 1 17.38 208 1 1 Free Air 34 0.96 #10 #10 55 52.8 CU #10 #10 20 PV WIRE 1.7183% (N)Branch-5 10 75 90 CU 55 2 1 17.38 208 1 1 Free Air 34 0.96 #10 #10 55 52.8 CU #10 #10 20 PV WIRE 1.1118% Combiner Box to POI Voltage Voltage Original Derated Ground Terminal Conductor Wiring Sets of Max Max Numberof Conduit Fill Height Ambient Temperature Drop Conductor Original Drop Conductor Voltage Combiner Box Equipment Wire Rating Length Conductor Conductor Conductor OCPD Rating Material Configuration wires Current Voltage conduits Derate Above Roof Tempeture Derate Corrected Ampacity EGC Corrected Type Drop Size Ampacity Material Conductor EGC Combiner Box Combiner Box to POI 75 90 CU 10 3 1 134.91 208 1 1 Conduit 34 0.96 1/0 1/0 170 163.2 CU #6 #6 150 PV WIRE 0.1583% ELECTRICAL NOTES 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR 75 DEGREE C. 3. THE WIRES ARE SIZED ACCORDING TO NEC 110.14. 4. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 5. WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG. 11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE. 12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). 17. THIS SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN OF PV CONDUCTORS IN COMPLIANCE WITH NEC 690.12. 18. LABELING IN COMPLIANCE WITH NEC 690.12 AND 690.56(C) IS SHOWN ON SHEET E-03. 19. ALL CONDUITS TO BE INSTALLED A MIN OF 7/8" ABOVE THE ROOF SURFACE. I ERMOCRATES CASTILLO PE# 52590 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 107, THE NEC 2017, AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION. Castillo l( Engineering k . SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER .:SOLAR Pn\A/FP Di itall No. stet aju<e W §gnled by: :E p. STATE of Ermocrate E Castillo �q��ONAnE„ Date: 2021.10.29 11:24:43 PROJECT NAME U Z W � U � J C'7 Q Q _J = U LL � LLI W U Q 2 W O� H rn c� �O Z LL U SHEET NAME WIRING CALCULATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-3.0 GENERAL NOTES: 1. RACK TO RACK BONDING ACCOMPLISHED WITH #6 CU OR EQUIVALENT CU BRAID WITH ENOUGH LENGTH TO PROVIDE SLACK. ALL RACKS IN ROW ARE BONDED. 2. RACK BONDED TO POUNDED PILE FOUNDATION OR 5/8'X10' CU PLATED STEEL GROUNDING ELECTRODE WITH #6 CU. TYPICAL FOR FIRST RACK ON EACH ROW. USE INDUSTRY BEST PRACTICES AND LISTED EQUIPMENT. 3. COMBINED DC GROUNDING ELECTRODE CONDUCTOR(GEC) AND AC EQUIPMENT GROUNDING CONDUCTOR PER 690.47(C)(3) ON EQUIPMENT GROUND BUS. TO MODULE d UL2703 CLAMPS TO UTILITY TRANSFORMER, BY OTHERS TO MODULE UL2703 CLAMPS 3/4", 10' GROUNDING ROD 1 GROUNDING DETAILS E-3.1 SCALE: NTS Castillo ((� Engineering k . SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407)289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER GOSOLAR POW F BEN Di itall No. 52��f12�lTfe wlyi"led by: of Ermocrate DP G2.E Castillo p�S/ONA�16N�0 Date: "'n.... 2021.10.29 11:24:43 PROJECT NAME U z W_ Lo � U � J C'7 Q Q J = U H LLI Lu U w Q 2 O� rn� c� z �O LL 2 SHEET NAME GROUNDING DETAILS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-3.1 AWARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.13(B)) AWARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(B)(2)(3)(b)) I ARFI I nrATlnnl- (PER CODE: NEC 690.56(C)(3)) ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.31 LABEL LOCATION: MAIN DISCONNECT (PER CODE: NFPA 11.12.2.1.5) LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.54) I ARFI I nrATInAI- POINT OF INTERCONNECTION (PER CODE: NEC 705.12(B)(2)(3)(b)) DATA PER PANEL LABEL LOCATION: COMBINER BOX (PER CODE: NEC 690.52) 0 PV SOLAR ARRAY ON ROOF SUB[ SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1) SERVICE POINT AND UTILITY METERING ALTERNATIVE POWER MAIN SERVICE DISCONNECT/ SOURCE AC DISCONNECT MAIN DISTRIBUTION PANEL 7469 COMMERCIAL CIR, FORT PIERCE, FL 34951 LABEL LOCATION: MAIN SERVICE DISCONNECT / MAIN DISTRIBUTION PANEL, PV DISCONNECT (TEXT HEIGHT SHOULD BE A MINIMUM OF 3/8") (PER CODE: NEC 690.56(B) AND NEC 705.10) PV SOLAR ARRAY SU RAFILJ ILJ%jVVw SWITCH/AC DISCONNECT POWER FROM UTILITY METER ., ,N SERVICE DISCONNECT/ MAIN DISTRIBUTION PANEL 7469 COMMERCIAL CIR, FORT PIERCE, FL 34951 LABEL LOCATION: MAIN SERVICE DISCONNECT / MAIN DISTRIBUTION PANEL, PV DISCONNECT (TEXT HEIGHT SHOULD BE A MINIMUM OF 3/8") (PER CODE: NFPA 1, 11.12.2.1) Castillo (p Engineering vw7 SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407)289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER ,4SOLAR POW F No. sz�igne_e Wl!§iy9led by: Ermocrate �6�a�,p'•�oR ;�P(y.° E Castillo p�S/ONA.. ENO` Date: a° ° 2021.10.29 11-24-44 PROJECT NAME U z W_ U J M O Q J = U LL LLi Y w U Q 2w Oa_ O z LL 2 U SHEET NAME SYSTEM LABELING SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-4.0 EAGLE 72HM 390-410 WATT • HALF CELL MONO PERC MODULE Positive power tolerance of 0-+3% • NYSE -listed since 2010, Bloomberg Tier 1 manufacturer • Best-selling module globally for last 4 years • Top performance in the strictest 3rd party labs • 99.9% on -time delivery to the installer • Automated manufacturing utilizing artificial intelligence • Vertically integrated, tight controls on quality • Premium solar panel factories in USA and Malaysia LINEAR PERFORMANCE WARRANTY 25-Year Performance Warranty 100% 115% 1 5 10 15 20 25 veers N. tlaNre: Y 11 JKM41 1c° 9 L-V C :t DS IM �� cooe coo. n coos c:,or�lnlio null Full null Normal nNl 10.0v l H Nao L Diamond v lsoov LISTED • IS09001:2008 Quality Standards OHSAS18001 Occupational • IS014001:2004 Environmental Standards Health & Safety Standards • IEC61215, IEC61730 certified products UL1703 certified products BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US KEY FEATURES ODiamond Half Cell Technology ® World -record breaking efficient mono PERC half cut solar cells deliver high power in a small footprint. ODesigned for Long Life Uses the same DuPont protective film as the Space Station, Mars Lander, and jetliners. 25-year warranty. Q Shade Tolerant Twin array design allows continued performance even with shading by trees or debris. Power Boost in Cloudy Conditions A special film diffuses light, boosting performance even with shading by trees or debris. Protected Against All Environments Certified to withstand humidity, heat, rain, marine environments, wind, hailstorms, and packed snow. ENGINEERING DRAWINGS Front Side Back l_ s �f� Length: ±2mm W c, Width:±2mm s i�........ i 1 ! . Height:±lmm 4Ito I1I[11f:11]ANIIlNu1111IN*IIIIIuIl4►L1ill ►11:111IN9411114►[1L Current -Voltage & Power -Voltage Temperature Dependence Curves (41OW) of Isc, Voc, Pmax 1m 2 420 160 10 350 a e 200 � uo 120 6 210. a 100 140- 80 Voc 2 90 y Pmex 0 o E 6o 0 5 to 1$ 20 25 0o 35 40 45 50 40 Voltage (VI zo so -25 o 25 so )s l00 Cell Temperature (°CI ELECTRICAL CHARACTERISTICS Module Type JKM390M-72HL-V JKM395M-72HL-V STC NOCT STC NOCT Maximum Power(Pmax) 390Wp 287Wp 395Wp 291Wp Maximum Power Voltage (Vmp) 39.64V 37.OV 39.90V 37.4V Maximum Power Current (Imp) 9.84A 7.75A 9.90A 7.77A Open -circuit Voltage (Voc) 48.6V 45.8V 48.8V 46.OV Short-circuit Current (lscl 10.46A 8.45A 10.54A 8.51A Module Efficiency STC I%) 19.38 % 19.63 % IuL��l�1:1►1[�I:1��J:I;L[�1�;�6��I�� Cells Mono PERC Diamond Cell (158.75xl58.75mm) No. of Half Cells 14416x241 Dimensions 2008x1002x40mm (79.06x39.45x1.57in) Weight 22.5kg (49.61bs) Front Glass 3.2mm, Anti -Reflection Coating High Transmission, Low Iron, Tempered Glass Frame Anodized Aluminum Alloy Junction Box IP67 Rated Output Cables 12 AWG, 1400mm (55.12in) or Customized Length Fire Type Type 1 Pressure Rating 54001'a(Snow)& 240OPa(Wind) TEMPERATURE CHARACTERISTICS Temperature Coefficients of Pmax-0.35%/°C Temperature Coefficients of Voc-0.29%/°C Temperature Coefficients of Isc 0.048%/°C Nominal Operating Cell Temperature (NOCTI 45±2°C MAXIMUM RATINGS Operating Temperature (°C)-40°C--85°C Maximum System Voltage 150OVDC (UL and IECI Maximum Series Fuse Rating 20A PACKAGING CONFIGURATION (Two pallets = One stack) 27pcs/pallet, 54pcs/stack, 594pcs/40'HO Container JKM40OM-72HL-V JKM405M-72HL-V JKM41OM-72HL-V STC NOCT SCT NOCT SCT NOCT 40OWp 294Wp 405Wp 298Wp 41OWp 302Wp 40.16V 37.6V 40.42V 37.8V 40.68V 38.OV 9.96A 7.82A 10.02A 7.88A 10.08A 7.94A 49.1V 46.2V 49.4V 46.5V 49.6V 46.7V 10.61A 8.57A 10.69A 8.63A 10.76A 8.69A 20.13 % 19.88 % 20.38 % *STC: Irradiance 1000W/m2 i� Cell Temperature 25°C C�S) AM = 1.5 NOCT:Irradiance 800W/m2 Ambient Temperature 200C (fS5 AM = 1.5 =_2-0_, Wind Speed 1m/s `Power measurement tolerance: ±3% SDP The company reserves the final right for explanation on any of the information presented hereby. JKM390-4 1OM-72HL- V-A4- US $pQaT •J/n«0 BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US .J//�«Q Castillo III Engineering SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407)289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER o SOLAR POW F 4..t..' 6!" •.O . Diqitallv No. szeVgrlajarewi§"led by: +i STATE OP Ermocrate ••. '<pq��P E Castillo •�SaJONA... Date: 2021.10.29 �m� p 11:24:44 PROJECT NAME U Z W Lo U J C7 Q Q __J = U LL LLI LUJ U Q LLI O ~ q) `n Q00 vO Z ti _ U SHEET NAME DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-01 Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ 7A Microinverter 0 To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7A Micro'" dramatically simplifies the installation process while achieving the highest system efficiency for systems with 60-cell and 72-cell modules. Part of the Enphase IQ System, the IQ 7A Micro integrates with the Enphase IQ Envoy'", Enphase IQ Battery-, and the Enphase Enlighten'"' monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. High Power • Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Easy to Install Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Efficient and Reliable Optimized for high powered 60-cell and 72-cell modules Highest CEC efficiency of 97% More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride - through requirements Envoy and Internet connection required Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) n ENPHASE Enphase IQ 7A Microinverter INPUT (DC) IQ7A-72-2-US Commonly used module pairings' 295 W-460 W + Module compatibility 60-cell, 66-cell, and 72-cell PV modules Maximum input DC voltage 58 V Power point tracking voltage range 18 V-58 V Min/Max start voltage 30 V / 58 V Max DC short circuit current (module Isc)3 15 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT (AC) @ 240 VAC @ 208 VAC Peak output power 366 VA 295 VA Maximum continuous output power 349 VA 290 VA Nominal (L-L) voltage/range4 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.45 A (240 VAC) 1.39 A (208 VAC) Nominal frequency 60 Hz Extended frequency range 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A (L-L) branch circuits 11 (240 VAC) 11 (208 VAC) Overvoltage class AC port III AC port backfeed current 18 mA Power factor setting 1.0 Power factor (adjustable) 0.85 leading ... 0.85 lagging EFFICIENCY @240 VAC @208 VAC CEC weighted efficiency 97.0 % 96.5% MECHANICAL Ambient temperature range -400C to +600C Relative humidity range 4% to 100 i (condensing) Connector type: DC (IQ7A-72-2-US) MC4 Dimensions (WxHxD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 Ibs) Cooling Natural convection — No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double -insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatobi lity. 2. CEC peak power tracking voltage range is 38 V to 43 V. 3. Maximum continuous input DC current is 10.2A. 4. Voltage range can be extended beyond nominal if required by the utility. 5. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2019 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ `' E N P H A S E Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2019-11-07 Castillo ((� Engineering k . SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407)289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER GO50I_AR POW F BEN Digitally No. 52� yf12�Ltfe wl§gnIed by: p, E of Ermocrate ETA 1�F3 •,<oe��P G2.`•` E Castillo i,�S/ONA�16N.0 Date: 2021.10.29 11:24:45 PROJECT NAME U Z W Lo U J C) Q Q J = U LL I LI W U Q W_ O� r� q �.J C.0 0 Z ti U SHEET NAME DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-02 Data Sheet Enphase Networking Enphase IQ Commercial Envoy U� LISTED To learn more about Enphase offerings, visit enphase.com The Enphase IQ Commercial Envoy'" gateway delivers solar production and energy consumption data to Enphase Enlighten'" monitoring and analysis software for comprehensive, remote maintenance and management of three-phase Enphase IQ Systems. With integrated production metering and optional consumption monitoring, the Envoy IQ is the platform for total energy management and integrates with the IQ Microinverters" and Enphase IQ Battery'". Smart Enables web -based monitoring and control Bidirectional communications for remote upgrades Supports power export limiting and zero - export applications Simple Easy system configuration using Enphase Installer Toolkit'" mobile app Flexible networking with Wi-Fi, Ethernet, or cellular Reliable Designed for installation indoors or outdoors in an enclosure Five-year warranty � ENPHASE Enphase IQ Commercial Envoy MODEL NUMBERS Enphase IQ Commercial Envoy" Three-phase communications gateway with integrated PV production metering (+/- 0.5%) ENV-IQ-AM3-3P and optional consumption monitoring (+/- 2.5%). Includes three 200A continuous rated production CTs. ACCESSORIES (order separately) Enphase Mobile Connect'" Plug and play industrial grade cellular modem with five-year data plan (expandable to CELLMODEM-M1 (413 LTE Category M1) 12 years) for systems up to 60 microinverters (expandable). Available in the US, Canada, CELLMODEM-MI-B (413 LTE Category M1) Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area. Consumption Monitoring CTs Split -core current transformers enable consumption metering. CT-200-SPLIT (order three or six, as needed) POWER REQUIREMENTS Power requirements 208Y/120 VAC three-phase 220Y/127 VAC three-phase Max 20 A overcurrent protection required Typical Power Consumption 5W CAPACITY Number of microinverters polled Up to 300 MECHANICAL & ELECTRICAL DATA Dimensions (WxHxD) 21.3 x 12.6 x 4.5 cm (8.4" x 5" x 1.8") Weight 17.6 oz (498 g) Ambient temperature range -400 to 65° C (-400 to 149° F) -400 to 46° C (-400 to 115° F) if installed in an enclosure Environmental rating IP30. For installation indoors or in an NRTL-certified, NEMA type 3R enclosure. Altitude To 2000 meters (6,560 feet) Production CTs Are limited to 200A of continuous current / 250A OCPD — 72kW AC Allow for parallel connected CTs for up to 500A — 144kW AC (if possible) Internal aperture measures 19.36mm to support 250MCM THWN conductors (max) Accuracy of +/-0.5% for revenue grade production metering (ANSI C12.20 certified) Consumption CTs For electrical services to 250A with parallel runs up to 500A Internal aperture measures 0.84" x 0.96" (21.33mm x 24.38mm) to support 3/0 THWN conductor CT wire insulation rating of 600V Accuracy of +/-2.5% for consumption monitoring INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet 802.3, Cat5E (or Cat 6) UTP Ethernet cable, not included Mobile Optional, CELLMODEM-M1 (LTE), CELLMODEM-01 (3G), or CELLMODEM-03 (413), not included COMPLIANCE Compliance UL 916 CAN/CSA C22.2 No. 61010-1 47 CFR, Part 15, Class B, ICES 003 IEC/EN 61010-1:2010, EN50065-1, EN61000-4-5, EN61000-6-1, EN61000-6-2 To learn more about Enphase offerings, visit enphase.com © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Commercial Envoy, and other trademarks or service names are the E N P H A S E trademarks of Enphase Energy, Inc. Data subject to change. 28-APR-2021 `/ Castillo Engineering SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407)289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER GOSOLAR POW F BEN Di itall No. s2�k�na�4re wiyi"led by: *' p , STATE Ermocrate =,F*.<.oA;e."•G?.'' E Castillo p�S/ON..... Date: "'n.... 2021.10.29 11:24:45 PROJECT NAME U z w 0 LSD U J C) Q Q J = U ILL. LLI W U Q W_ r� q) 1' O z LL SHEET NAME DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-03 A/ IRONRIDGE Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. Force -Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs XR Rails are IronRidge offers compatible with a range of tilt leg FlashFoot and options for flat other pitched roof ■■■ roof mounting attachments. applications. XR Rail Family Corrosion -Resistant Materials All XR Rails are made of 6000-series aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing . a more attractive appearance. XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. i XR10 XR10 is a sleek, low -profile mounting rail, designed for regions with light or no snow. It achieves spans up to 6 feet, while remaining light and economical. 6'spanning capability Moderate load capability Clear & black anodized finish Internal splices available Rail Selection i FP- XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 10 feet. 10' spanning capability Heavy load capability Clear & black anodized finish Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans up to 12 feet for commercial applications. 12' spanning capability Extreme load capability Clear anodized finish Internal splices available The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria: ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. 90 120 None 140 XR10 160 90 120 20 140 160 90 30 160 90 40 160 80 160 Rail Span 5' 4" 6' 8' in XR100 XR1000 120 I 160 I *Table is meant to be a simplified span chart for conveying general rail capabilities. Use approved certification letters for actual design guidance. © 2020 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.20 Castillo p Engineering SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER SOLAR No52sfgng,11ew1!§iY9Ied by: o:. STATE OF ; Ermocrate �•• •ASS ONAIE�G `�`�. E Castillo Date: 2021.10.29 _m.a.•m,•ao 11:24:46 PROJECT NAME U Z W U J M O Q J = U LL Y w U Q 2w a_ ~ O� Z ti LL U SHEET NAME DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-04 NEW \J ProteaBracketTM is compatible with common metal roofing materials and comes with a pre -applied EPDM gasket on the base. Note: All four pre -punched holes must be used to achieve tested strength. Fasteners are provided. For design assistance, ask your distributor, or visit www.S-S.com for the independent lab test data that can be used for load -critical designs and applications. Also, please visit our website for more information including metallurgical compatibilities and specifications. 5-5je holding strength is unmatched in the industry. Multiple Attachment Options: ug Side Mount Rail Bottom Mount Rail w/ S-5! PVKITTM (rail -less) ProteaBracketTM ProleaBracket' is still available in stainless steel. O� 0.35" x 1.00" Slotted ProteaBracketfits profiles up to 3 inches 'Q` `N07/ No surface preparation needed. (1) Wipe away excess oil and debris. (2) Peel off adhesive release paper. (3) Align and mount bracket directly onto crown of panel. (4) Secure ProteaBracket through pre -punched holes, using piercing -point S-5! screws. 5-5!1Warning! Please use this product responsibly! Distributed by products are protected by multiple U.S. and foreign patents. For published data regarding holding strength, bolt torque, patents, and trademarks, visit the 5-51 website at www.S-5.com. Copyright 2019, Metal Roof Innovations, Ltd. S-51 products are patent protected.S-5I aggressively protects its patents, trademarks, and copyrights, Version 07089. Castillo ((� Engineering k . SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407)289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER GOSOLAR POW F BEN •. � Digitally No. 's2et3 ajar Wlyignled by: ri �= STATE OErmocrate F .T�SS<Oq�0NG2p E Castillo Date: 2021.10.29 " 11:24:46 PROJECT NAME 0 z w Lo U J C7 0 aJ = U LL LLI Lu U w Q 2 0� ~ rn c0 0 z �O LL 2 SHEET NAME DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-05