Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY CALCS & MANUAL J - 10 NOGALES(1)
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number. Owner. Jurisdiction: Design Location: FL, Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type�1432,0 sgft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1224.00 W b.Frame-Wood,Adjacent R=11.0 208.00€t2 3. Number of units,if multiple family 1 c.NIA R= ft2 4. Number of Bedrooms 3 d.NIA R= ft2 5. Is this a worst case? Yes 11.Ceiling Types (1783.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1753.00 ff2 6. Conditioned floor area above grade(W) 1753 b.Knee Waif(Vented) R=19.0 30.00 f12 Conditioned floor area below grade(W) 0 c.NIA R= ft2 7. Windows(l51.4 sgfL) Description Area 12.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 195 a. U-Factor. Sgi,U=1.02 111.36 fr SHGC: SHGC=0.29 b. U-Factor: Sgl,U=1.11 40.00 ff2 13.Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 a.Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ft2 SHGC: 14,Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.850 ft. a.Electric Heat Pump 34.$ HSPF:8.50 Area Weighted Average SHGC: 0.285 8. Skylights Area G. U-Factor:(AVG) NIA ft2 15.Hot water systems SHGC(AVG): NIA a.Electric Cap:40 gallons 9. Floor Types (1753.0 sgft.) Insulation Area EF:0.970 a.Slab-On-Grade Edge Insulation R=Q.O 1753.00 ft2 b. Conservation features b. NIA R= ft2 None c.NIA R= ft2 15.Credits None Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49.38 PASS Total Baseline Loads: 50.69 1 hereby certify that the plans and specifications covered by Review of the plans and C~ T this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. rr,+,:,.."H ✓.;°°fir 4 PREPARED BY., Before construction is completed w F v DATE. 1-12-2021 this building will be inspected for A. compliance with Section 553.908 hereby certify that this building,as designed,is in compliance Florida Statutes. 1 with the Florida Energy Code. Q WE'� OWNERI ENT• BUILDING OFFICIAL: - DATE: N \.k\ DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE W INDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner Name: Total Stories: 1 BIocldSubdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE W INDSOR Permit Office: ST,LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Detached FL, New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp J Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 M24 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil lD Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREATR 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft2 -- 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' _—_ 0 1 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' _—_ 0 1 0 4 Slab-On-Grade Edge Insulatio M.BATH 7 ft 0 61 ft2 _—_ 0 1 0 5 Slab-On-Grade Edge Insulatio LAUDRY 1 ft 0 36 112 — 0 1 0 1/12/2021 1:15 PM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Pedmeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 _— 0 1 0 7 Slab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 _— 0 1 0 8 Slab-On-Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 _—_ 0 1 0 9 Slab-On-Grade Edge Insulatio BATH 5 ft 0 50 ft2 ____ 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 _ 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 ___ 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 ___ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1947 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 / ATTIC t� # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic(Vented) M.BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic(Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic(Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic(Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic(Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic(Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 13 Knee Wall(Vented) DINING/GREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below it Omt T� Wall Type _ 1 NE=>SW Exterior Concrete Block-Int InsMASTER BE 4.1 16 0 8 0 128.0 ft- 0 0 0.3 0 — 2 SW=>NE Exterior Concrete Block-int InsWASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 3 NW=>SE Exterior Concrete Block-Int lns&nASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 -4 NE=>SW Exterior Concrete Block-Int InsWASTER SA 4.1 8 0 8 0 64.0 ft2 0 0.3 0 -5 NE=>SW Exterior Concrete Block-Int Insul M.BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 - 6 NE=>SW Exterior Concrete Block-Int InsBIEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 - 7 SW=>NE Exterior Concrete Block-Int InS011NING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.3 0 _8 NW=>SE Exterior Concrete Block-Int lnsalNING/GRE 4.1 20 0 8 0 160.08' 0 0 0.3 0 9 SW=>NE Exterior Concrete Block-Int InsulKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 _10 NE=>SW Exterior Concrete Block-Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 _11 SE=>NW Exterior Concrete Block-Int Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 12 SW=>NE Exterior Concrete Block-Int Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 13 NE=>SW Exterior Concrete Block-Int InsEEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 _14 SW=>NE Exterior Concrete Block-Int InsBEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 15 N=>S Garage Frame-Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.3 0 DOORS # Omt Door Type Space Stones U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated FOYER None .39 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => chanced to Worst Case. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.02 0.29 Y 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>SW 5 Metal Low-E Single Yes 1.02 0.29 Y 6.9 ft2 1 It 0 in 1 It 4 in None None 3 NE�SW 6 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft2 1 It 0 in 1 It 4 in None None 4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29 Y 39.8 ft2 1 It 0 in 1 It 4 in None None 5 NW=>SE 8 Metal Low-E Single Yes 1.11 0.27 Y 40.0 ft2 8 ft 0 in 1 ft 4 in None None 6 NE=>SW 13 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft2 1 It 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EcILA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12 120.37 .0902 5 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER:15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft' DUCTS —Supply— —Return— Air CFM 25 OFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Coot 1 Attic 6 195 ft' Attic 55 ft- Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[ling (e ThermostatJan : 'IN [Feb [X]] CMar Apr [[eiilling Fans:May ([X7� Jul[JunDCt]Jul Aug [X]J [[ Nov[rX,]NovrX)� Dec Vven venting [ ]Jaann [ ]Febeb N Mar Apr [ ]May [ ]Jun [ }Jul Aug [ ]Seep Oct [X]Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. OW Oft 0.3 MASTER BEDROO Default(8 lbs/sq.fL ftz ft 0.3 WIC Default(8 lbs/sq.ft. ft' ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft' ft 0.3 M.BATH Default(8 lbs/sq.ft. ft' ft 0.3 LAUDRY Default(8 lbs/sq.ft. ft' ft 0-3 BEDROOM 2 Defautt(B Ii ft' ft 0.3 DINING/GREAT R Default(81bs/sq.fL ft' ft 0.3 KITCHEN 1/12/2021 1:15 PM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 HALL Default(B lbs/sq.ft. W ft 0.3 FOYER Default 8lbs/s .ft. ft' ft 0.3 BEDROOM 3 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 6 of 6 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number. Y Owner: Jurisdiction: w x Design Location: FL,Fort Pierce V COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealingmaterial. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic y dropped The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an soffit pp ceiling/soffit g/ the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity g insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind pin no an w!Hnn Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box oi The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index,the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1224.00 ft' b. Frame-Wood,Adjacent R=11.0 208.00 ft' 3. Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 3 d.NA R= 11.Ceiling Type and insulation level Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1753.00 ft' 6. Conditioned floor area(W) 1753 b.Knee Wall(Vented) R=19.0 30.00 ft' c.NIA R= ftz 7. Windows" Description Area a. U-Factor: Sgl,U=1.02 111.36 ft' 12. Ducts,location&insulation level R a.Sup:Attic,Ret:Attic,AH:Attic 6 19595 SHGC: SHGC=0.29 b. U-Factor: Sgl,U=1.11 40.00 ft° SHGC: SHGC=0.27 13.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a.Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor. N/A ft' 14.Heating systems kBtuWhr Efficiency SHGC: a.Electnc Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.285 8. Skylights Description Area 15.Hot water systems Cap:40 gallons a. U-Factor(AVG): N/A ft, a. Electric EF:0.97 SHGC(AVG): NIA b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft' Credits(Performance method) None b.N/A R= ft' c.N/A R= ft' 1 certify that this home has complied with the Florida Energy Efficiency Code for Building 049 Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant feature Builder Signature: Date: r� l Address of New Home: N v ` Q City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida Energy Rating, For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 WrightsoftProject Summary Job: . Entire House 8y QUICK CALCS, INC. 317 ST.LUCIE UN,FT.PIERCE,FL 34946 Phm :772-466-6799 Fax 7r2466-6796 Email:QUICKCALCS@AOL.COM Project • • For. WYNNE DEVELOPMENT THE WINDSOR,FT.PIERCE,FL Notes: Design Information Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 Insidedb 70 OF Insidedb 75 °F Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 21542 Btuh Structure 16420 Btuh Duds 6191 Btuh Duds 9337 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 Clint) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27734 Btuh Use manufacturer's data n Rate/swingg multiplier 0.95 Infiltration Equipment sensible load 24470 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2495 Btuh Central vent(0 cfin) 2 0 Btuh Heatingg cool, (none) Area(fP) 1753 1753 Equipment latent load 5041 Btuh Volume(ft') 16478 16478 Airchanges/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 29511 Btuh Equiv.AVF(dln) 104 55 Req.total capacity at0.70SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A 030 Cond 25HBC536A 030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating Input Sensible cooling 24360 Btuh Heating output 34600 Btuh@47°F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual air flow 1160 Cirri Actual airflow 1160 cfin Airflow factor 0.042 cfm/Btuh Airflow factor 0.045 chvBtuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point=36 OF Backup: Input=7kW, Output=23009 Btuh,100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrights ft- 2021-Jao-1213:18:18 Ri91tSuL-OUriversa1201919.021 RSU08101 Page 1 ...Doamer6AWdgft�4M/AMWVNNE-THEWINDSOPrp Calc=M18 FrorRDo rfaces:N wrightsott° Right-M Worksheet Dom' Dat Entire House By. QUICK CALCS, INC. 317 ST.LUCIE LN.,Fr.PIERCE,FL 34946 Prnre:772466-6799 Fax T246 796 Email:QUICKCF.LCSQAOL.COM 1 Room name Entire House BEDROOM 2 E)posed wall 207.6 It 41.0 t 3 Room height 9.4 A d 9.4 ft hegold 4 Room dimensions 14.0 z 20.0 ft 5 Room area 1753.0 IF 280.0 ft' 7y number BluhdLI-value Or HTM Area (n Load Area (n Load number (BWhHF-°� (BWW) or pedmeter (ft) (BWh) or perimeter (ft) (BWh) Hea[ Cool Gros NIPS Heat Cool Gros WPS Heat Cool 6 Vy 13A4acs 0.143 n 4.00 2.55 649 596 23N 1517 66 66 263 167 1Aa1an 1270 n 3556 34.77 15 0 533 522 0 0 0 0 4A5-2om 0.770 n 21.56 19.31 38 0 815 730 0 0 0 0 W 13A-0ors 0.143 ne 4.00 2S5 27 27 106 68 0 0 0 0 11 4U 13A4ocs 0.143 a 4.00 2.55 141 100 400 255 0 0 0 0 1A-clom 1270 e 3556 6706 20 1 711 1741 0 0 0 0 D 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A-4c s 0.143 se 4.00 2.55 27 27 106 68 0 0 0 0 W 13AAos 0.143 s 4.00 255 536 530 2121 1349 188 188 753 479 I--l' 1A-dom 1270 s 3556 34.77 6 6 213 209 0 0 0 0 Vy 13A-4= 0.143 w 4.00 2.55 320 255 1022 649 132 108 432 275 IIL----GGG tAttan 127D w 3556 54.53 12 1 415 636 12 1 415 635 1Actctn 1270 w 35.56 5453 12 1 427 654 12 1 427 654 4AS2om 0.770 w 2156 45.63 41 2 880 1862 0 0 0 0 P 12C-09N 0.091 2,55 128 254 254 647 326 0 0 0 0 C 16A-30md OA32 0.90 2.32 1753 1753 1571 4067 280 280 251 650 F 22A-Ipl 0.989 - 27.69 0.00 1753 208 5748 0 280 41 1135 0 6 c)AED emersion 397 48B Envelope loss/gain 18331 15285 3676 3349 12 a) Infiltration tltration 3211 90 0 2 0 b) Rcomvenfiiation 0 13 Internal gains: Ooalpants@ 230 1 230 0 0 Appliances/other 0 0 Subtols(lirlm;ft13) 21542 16420 4405 3554 Lessetlemalload 0 0 0 0 Lestrznsfer 0 0 0 0 Redr&buWn 0 0 0 0 14 Subblal 26191 19337 1266 3551 15 Dud loads 29% 57% 6191 9337 29% 57% 1266 2021 Total room load 27734 25757 5671 5575 Air required(dm) 1160 "An 237 251 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. � Isto'm 2021 Jarv121 Pagel rti9kSute®UdYEnsal2p19 t9.o21 RSU0810M1 Page 1 A&k ...DoO rlslWdgtioft HUAQWVNNE-THEWINDSOR� calc=MlB Fror¢Doorfaces:N wrightsofr Right-J@ Worksheet Job: . Entire House By QUICK CALCS, INC. 317 ST.LUCIE LN.,Fr..PIERCE,FL 34946 Phone:772466-6799 Fax 772466-6796 Email:QUICKCALCS@IOL.COM Toom name WIC MASTER BATH Vosecivall 0 ft 9.0 ft own hegM 94 tt heatlmol 94 ft heattod oom dime—'* 7A x 9.0 R 7.0 X 9A R oom area 63.0 ff 63.0 1F Ty Condrumon U-value Or HTM Area (R) Load Area (fl� Load number (BNt+JF-q (BNhAF) or penmeer (t) (fth) or perimeter (ft) (BWh) Heat Cool Gras N/P/S Heat Cool Gros N/PS Heat Cool 6 V�/ 13AAors 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 I—C 1A-dw 1270 n 3556 34.77 0 0 0 0 0 0 0 0 I—G 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 W 13A4o1s 0.143 ne 4AD 2.55 0 0 0 0 0 0 0 0 11 VL 13A4ors 0.143 e - 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 a 35.56 87.06 0 0 0 0 0 0 0 0 ���------..DDD 11DO MW a 1092 11.31 0 0 0 0 0 0 0 0 W 13A400s 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 t13A40rs 0.143 s 4.00 2S5 0 0 0 0 85 85 339 215 —G 1Aclom 1270 s 3556 34.77 0 0 0 0 0 0 0 0 Vfl 13A4as 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 I—G 1Mctan 1270 w 35S6 54M 0 0 0 0 0 0 0 0 1Ac1cm 1270 w 3556 54.53 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 p 12C-OUN 0.091 - 2S5 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2,32 63 63 56 146 63 63 56 146 F 224-tpl 0.989 - 27B9 0.00 63 0 0 0 63 9 249 0 6 c)AED emurson •10 -28 Envelope losstgain 56 136 644 334 12 a) Infiltration 0 0 160 45 b) RoomverNlation 0 0 0 0 13 Allemal gains: Oavpar&@ 230 0 0 0 0 Applianoe9otner 0 0 Subtotal(lines 6 to 13) 56 136 804 379 Lessexemalload 0 0 0 0 Lesstansfer 0 0 0 0 Redistributm 0 0 0 0 btotal 56 136 804 379 ctloa 14 Su 15 Dubt0bJ 29% 57% 16 77 29% 57% 231 216 Total room load 73 214 1036 595 Air required(dn) 3 10 43 27 Calculations approved b ACCAto meet all recuirementS of Manual J 0 Ed. -►*wrigMtsolt� 2021-Jan�1213:18:18 PogFtSute®Uriversa{201919.021 RSU08101 Page2 ..Doa rtr\Wrigtfsoft HVAC\WYNNE-THEWINDSORnp Calc=M18 FradDoorfaces:N wrighttsoft Right-JO Worksheet Job: Entire House Dom: QUICK CALCS, INC. 8y. 317 ST.LUCIE UN.,Fr.PIERCE,FL 34946 Phom:772-466.6799 Fax 772-466-6796 Email:QUICKCALCS @t AOL.COM 1 Room name MBATH KrrCHEN 2 EVosedwall 8A ft 8.0 ft 3 Room height 9.4 It heatlmol 9.4 ft heaV=l 4 Room dimensions 7.0 x 8.0 ft 1A x 172.0 It 5 Room area 56.0 1F 172.0 W Ty Construction U-value Or HTM Any Load number (BtrlhAF-'9 (Btuh(P) or perimeter (ft) (BWh) oorperimeter (ft) (Bluh) Heat Cool Gros NrPiS Heat Cool Gros NIPS Heat Cool 6 Y}/`�(G' 113A-4= 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 n 35M 34.77 0 0 0 0 0 0 0 0 4AS2om 0.770 n 2156 19.31 0 0 0 0 0 0 0 0 w 13A-4= 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 � 13A-4= 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1Actom 1270 a 35.56 87.06 0 0 0 0 0 0 0 0 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 w 13A4os 0.143 se 4.00 2M 0 0 0 0 0 0 0 0 V�1 13A-4= 0.143 s 4.00 255 75 69 277 176 0 0 0 0 I-G 1At1@m 1270 s 35.56 34.77 6 6 213 209 0 0 0 0 13A4ors 0.143 w 4.00 2.65 0 0 0 0 0 0 0 0 IA-dom 1270 w 3556 54M 0 0 0 0 0 0 0 0 1Actom 1270 w 3556 5453 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C O w 0.091 - 2.55 128 0 0 0 0 75 75 192 96 C 16A30md 0.032 - 0.90 2.32 56 56 50 130 172 172 154 399 F 22A-tpl 0.989 - 27.69 0.00 56 8 222 0 172 8 222 0 6 c)AED e=rsion 38 -34 Envelope loss/gain 762 477 567 462 12 a) Infiltration 142 40 0 0 b) Rcomventilation 0 0 0 0 13 Intemalgains: Oaupants@ 230 0 0 0 0 Appliancesrother 1p 0 Submhal(lines6to13) 904 517 567 462 Lesememalload 0 0 0 0 Less transfer 0 0 0 0 Redis4ibution 0 0 0 0 14 Subtotal 904 517 567 462 15 Dudloads 29% 571 260 294 29h 57% 163 263 Total room load 1164 811 730 725 Air required(dm) 49 37 31 33 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. AG -►�r►wrl9btsol'[-... Rgtt rve 9.021 RS 2021JarN213:18:18 A D@mrtslWdgtsotHACWYNNE-THEWINDSORnp Calc=NB FrortDoortaos:N Page wrightsoft° Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LN,Fr.PIERCE.FL 34946 PhO.:772-468-6799 Fax:772-466-6796 Emil:QUrKCALCS@AOLCOM 1 Room name BATH BEDROOM2 2 Evosedulall 5D ft 426 It 3 Room height 9A it heatlmd 9.4 It heakml 4 Room dimensions 90 x 5D It 1.0 x 204D ft 5 Room area 45D If 204D IF Ty Construction U-value Or HTM Area (IF) Load Area (ftF) Load number (BWhrlln (BIL]w or Penmeter (it) (Bluh) or perimeter M puh) Heat Cool Gros N/P/S Heat Cad Gross NIPS Heat Cool 6 Vd 1344as Q143 n 4.00 255 47 47 188 120 132 132 527 335 �LGG IAciarn 12M n 3556 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.T70 n 2156 1931 0 0 0 0 0 0 0 0 W 13A4= 0.143 ne 4A0 2.55 0 0 0 0 27 27 106 68 11 4y 13A4= 0.143 a 4D0 255 0 0 0 0 85 65 259 164 II .G 1Actom 1270 a 3556 87D6 0 0 0 0 20 1 711 1741 11DO 0390 a 1092 1131 0 0 0 0 0 -0 0 0 W 13A4= 0.143 se 4DO 255 0 0 0 0 27 27 106 68 W 13A4= 0.143 s 4DO 255 0 0 - 0 0 132 132 - -527 335 L-G 1Aclw 1270 s 35M 34.77 0 0 0 0 0 0 0 0 13A4= 0.143 w 4.00 255 0 0 0 0 0 0 0 0 1Aatom 1270 w 35M 54.53 0 0 0 0 0 0 0 0 1Aclorn 1270 w 35,56 54M 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21M 45.63 0 0 0 0 0 0 0 0 P 12C-Ow OD91 - 255 128 0 0 0 0 0 0 0 - 0 C 16A-30md aim - 090 232 45 45 40 104 204 204 183 473 F 22A4111 0989 - 27.69 aim 45 5 138 0 204 43 1179 0 6 c)AEDeuursIw -17 -99 Emelope loss/gain 367 207 35991 3W5 12 a) Infikh-A n 89 25 758 214 b) Rcomsentilation 0 0 0 0 13 Intemalgaim O=pants@ 230 0 0 0 0 Applianoesbfw 0 0 Subotal(lin to 13) 466 232 4357 3299 LesoMmalload 0 0 0 0 s Letransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 456 232 4357 3299 15 Dudioads 29% 57% 131 29% 57% 1252 1876 TOCil rooml0ad 587 364 5609 5175 Airrequired(ofi) 25 16 1 1 235 233 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. +�1- wri9h>tsvf'C' 2021.Hm1213:18:18 ACCA RigkTHEWINDS Rztp 919.021B FUort Dt Paga4 ...DcamerPslWngh�ofl HUAgWYNNE-THE WINDSORn.p Calc=M18 ROk OeorfacesN I wrightsoft° Right.J®Worksheet Date: Entire House Date: By. QUICK CALCS, INC. 317 ST.LLME LN.,FT.PIERCE,FL 34946 Plane:772-466-6799 Fax 772-466-6796 Emil:OUICKC4LCS@AOL.COM 1 Room name ENTRY LAUNDRY 2 Fed Vail 18.0 ft 13.0 ft 3 Room height 9.4 It heaVcool 9.4 ft heaVMOt 4 Room dimenaone 1.0 x 92.0 ft 7.0 x 6.0 ft 5 Room area 920 1F 42.0 fF Ty I COnSbUdIDn U-value Or HTM Area (fl0 Load Area (fM Load number (BluKV--T) (BWhfiF) or perimeter (ft) (BWh) or penmeler (ft) (BWh) Heat Cool Grins NIPS Heat Cool Gross NIPS Heat Cool 6 VI/ 13AA= 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1Aciom 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 2156 19.31 0 0 0 0 0 0 0 0 W 13AA= 0.143 re 4.00 2.55 0 0 0 0 0 0 0 0 11 Y)/ 13A-4= 0.143 a 4A0 2.55 56 35 142 90 0 0 0 0 IL---DG 1Aclom 1270 a 3556 87.06 0 0 0 0 0 0 0 0 NDO 0.39D a 10.92 11.31 21 21 229 238 0 0 0 0 w 13A4ots 0.143 se 4A0 2.55 0 0 0 0 0 0 0 0 t13A4ocs 0.143 s 4.00 2.55 0 0 0 0 56 56 226 144 -C IAttom 1270 5 3556 3477 0 0 0 0 0 0 0 0 13AAoas 0.143 w 4.00 Z55 0 0 0 0 0 0 0 0 I---G 1Atlom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 IL----GG 1Actom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 4A5.2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C-0aN 0.091 - 2.55 126 113 11$ 287 145 66 66 168 84 C 16A-30md 0.032 - 0.90 2.32 92 92 82 213 42 42 38 97 F 22A-tpl 0.989 - 27.69 0.00 92 18 498 0 42 13 360 0 L 1 6 c)Ameuu M 49 -24 Envelope loWgain 1 1239 637 7911 301 12 a) Infiltralion 107 30 t107 b) Roomwnlilation 0 0 13 intemalgaim: O=pants@ 230 0 0 0Applianoes(other 0 SubtoW(line l5b313) 1346 667 Lesse)�malload 0 0 Lmtransfer 0 0 Redisfribubon 0 0 14 Subtotal 1346 667 15 Dud loads 29% 57% 387 379 29% 57%Total room load 1733 1047 Airrequired(cfrn) 72 47 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. 2021-Jan1213:18:18 %^ Ri9H-Sute®Uriversa4201919.02tfiSU08t01 A Page5 ..Doa r41Wn9HSoft HVAQWYNNE-THEWINDSORAP calc=lws Front Doorfaces:N F�F wrightsoft° Right-M)Worksheet icw Entire House Date: By. QUICK CALCS, INC. 317ST.LL)aELN.,Fr.PIERCE,FL34946Ptom:772-466-M9 F=7724665796 Email:QUICKCALCS@ AOL.COM 1 Rcom re GREATIDNNG Rcan7 2 5posedwall 50D a 130 it 3 Rcom height 9.4 ft heatlmol 9.4 it hedbod 4 Room d'anensiom 1.0 x 567D ft 13D x 13D ft 5 Rcomaw 567D 12 169.0 ft Ty Construclim U-value Or HTM Area (fF) Load Ana (n Load number (Btohr-°n a penmen (tt) (Mh) a perimeter (it) (Bbih) Heat Cool Gms NIPS Heat Cool Gros NIPS Heat Cod 6 13A-4= 0.143 n 4.00 255 282 244 978 622 122 107 429- 273 1Ao1an 1270 n 35.56 34.77 0 0 0 0 15 - 0 - 533 522 4A5-2om 0.770 n 2156 1931 38 0 815 730 0 - 0 0. 0. w M Ims 0.143 ne 4.00 255 0 0 0 0 0 0 0 0 11 14f 13A4a 0.143 a 4.00 255 0 0 0 0 0 0 0 _ 0 {L—DG 1A-dw 1270 a 3556 87.06 0 0 0 0 0 0 - 0 0 11DO 0" a 1092 1131 0 0 0 0 0 0 0 -0 W 13A4a 0.143 se 4DO 255 0 0 0 0 0 0 0 0 VL—C 13A4= 0.143 s 4DO 255 0 0 0 0 0 - 0 - ' -0 - - 0 IA-clm 1270- s -3556 34.77 0 0 0 0 0 0 0 0 13A-4= 0.143 w 4D0 255 188 147 589 375 0 0 0 0 1Ac1an 1270 w 3556 5453 0 0 0 0 0 0 0 0 1Ac1an 1270 w 3556 5453 0 0 0 0 0 0 0 0 4AS2om 0.770 w 21M 45.63 41 2 880 1862 0 0 0 0 P 12C-Osv 0D91 255 128 0 0 0 0 - 0 0 0 -0 C 16AJOmd OD32 - 090 2.32 567 567 508 1315 169 169 151 392 F - 22A4p1 0989 - 27.69 0.00 567 50 1385 0 169 13 -360 0 6 c)Ame>saison - 307 -100 2melopeloslgain 5154 5210 1474 1086 12 a) Imilt-4on 889 251 231 65 b) Roanvenblatlon 0 0 0 0 13 Inknal gains: O=pants@ 230 0 0 1 230 Applianoeslother 0 0 Subbml(11rws6to13) 6043 5461 1705 1381 LesseWemalload 0 01 0 0 s Leransfer 0 0 0 0 Redisiibufion 0 0 0 0 14 Subtotal 6043 5461 1705 7381 15 Dudbads 29% 57% 1737 3105 29%1 5N.1 490 785 Total roan load 7% 8566 2195 2167 Air required(dm) 325 386 92 98 Calculations approved byACCA to meet all requirements of Manual J ft Ed. T�wri9hLsof'!' 2021Jar 1213:18:18 A LA RigHSUfe®LSiwmal201919.021 RSU08101 Page ...Downers\WrigrmItWAgWYNNE-THEWINDSORnp Calc=W8 F=11)oorfams N - wrightsoft. Duct System Summary o : Entire House sY QUICK CALCS, INC. 317 ST..LUCIE LN.,Fr.PIERCE,FL 34946 PIore:772-466-6799 Fax 772466-6796 ErreiL OUICKC4LCS@AOL.COM Project • For. WYNNE DEVELOPMENT THE W INDSOR,FT.PIERCE,FL Heating Cooling External static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.00010.000 in H2O 0.000/0.000 in H2O Lowestftiction rate 0 in/100ft 0 in/100ft Actual airflow, 1160 elm 1160 cfm Total effective length(TEL) 0 ft SupplyDetail Table Htg CIg Design Diam H x W Dud Actual Ftg.Egv Name (Bluh) (dm) (cfm) FR (in) (in) mat Ln(ft) Ln(ft) Trunk BATH h 364 25 16 0 0 Ox 0 ShMt 0 0 BEDROOM C 2788 119 126 0 0 Ox0 ShMt 0 0 BEDROOM2 h 2587 117 117 0 0 Ox0 ShMt 0 0 BEDROOM 2-A h 2587 117 117 0 0 Ox0 ShMt 0 0 BEDROOM-A c 2788 119 126 0 0 Ox0 ShMt 0 0 ENTRY h 1047 72 47 0 0 Ox0 ShMt 0 0 GREAVDINING C 2855 108 129 0 0 Ox 0 ShMt 0 0 GREATIDINING-A c 2855 108 129 0 0 Ox 0 ShMt 0 0 GREAT(DINING-B C 2855 108 129 0 0 OXO ShMt 0 0 KrrCHEN C 725 31 33 0 0 OxO ShMt 0 0 LAUNDRY h 520 48 23 0 0 Ox 0 ShMt 0 0 M.BATH h 811 49 37 0 0 Ox 0 ShMt 0 0 MASTERBATH h 595 43 27 0 0 Ox0 ShMt 0 0 Ro M7 C 2167 92 98 0 0 Ox0 ShMt 0 0 WIC c 214 3 10 0 0 Ox0 ShMt 0 0 Return Branch Detail Table Htg CIg TEL Design Veloc Diam HxW Stud/Joist Dud Name Size(in) (cfm) (ckn) (ft) FR (fpm) (in) (in) Opening(in) Mad T unk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 ShMt wrightsofY 2021-Iarv1213:18:19 "C • -� -w,-..v...�, Rigf4Sute®LYiversa1201919.021 RSU08101 Pagel A ...Doamerts\WrigF�oft HVALiWYNNE-THE WINDSOR.np GIc=MJB Frorrt Doorhces:N