HomeMy WebLinkAboutFL17401_R5_II_MSA17001.2 2020 FBC Eval QUIK-Stick final3 iYl 0`2 _
Professional ' . � d
r
BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge I Stats&Facts Publications Contact Us BCIS Site Map Links Search
bpr
Product Approval` USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
OFFICE OF THE FL# FL17401-R5
SFCRETARY
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Mid-States Asphalt&Cant Strip, Inc.
Address/Phone/Email 1637 51st Ave
Tuscaloosa,AL 35401
(205) 394-3078
moises@msaroof.com
Authorized Signature Moises Rached
moises@msaroof.com
Technical Representative Moises Rached
Address/Phone/Email 1637 51st Ave
Tuscaloosa,AL 35401
(205)469-2101
moises@msaroof.com
Quality Assurance Representative Moises Rached
Address/Phone/Email 1637 51st Ave
Tuscaloosa,AL 35401
(205)469-2101
moises@msaroof.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2024
Validated By Steven M. Urich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL17401 R5 COI MSA17001.2 2020 FBC Eval QUIK-Stick final3.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D 1970 2015
TAS 103 2020
TAS 110 2000
UL1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 02/14/2019
Date Validated 10/31/2020
Date Pending FBC Approval 11/02/2020
Date Approved 12/15/2020
Date Revised 03/31/2021
Summary of Products
FL# Model,Number or Name Description
17401.1 QUIK-Stick Ice&Water Granular, Self-Adhered Underlayments
QUIK-Stick Ice&Water Sand,QUIK-
Stick HT Smooth,QUIK-Stick HT Pro,
QUIK-Stick FS
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17401 R5 II MSA17001.2 2020 FBC Eval QUIK-Stick
Approved for use outside HVHZ:Yes final3.pdf
Impact Resistant: No Verified By: Zachary R. Priest PE-74021
Design Pressure: +0/-52.5 Created by Independent Third Party: Yes
Other: Refer to Evaluation Report for Limitations of Use. Wind Evaluation Reports
uplift applicable to QUIK-Stick HT only. FL17401 R5 AE MSA17001.2 2020 FBC Eval QUIK-Stick
final3.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
Credit Card
Safe
CREEK Certificate of Authorization bur 29824
17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,7T"EDITION (2020)
Manufacturer: MID-STATES ASPHALT AND CANT STRIP, INC. Issued October 16, 2020
1637 51 st Street
Tuscaloosa,AL 35401
(800)489-2391
www.msaroof.com
Manufacturing Location: Tuscaloosa,AL
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1504.3.1, 1507.1.1
Properties: Physical properties
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST5878) BWR-514-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST5878) BWR-522-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST5878) BWR-534-02-01 ASTM D 1970 2015a
ASTM D 4798 2011(2016)
PRI Construction Materials Technologies(TST5878) BWR-543-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST5878) WRMI-011-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST5878) MSA-004-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) MSA-007-02-01 UL 1897 2012
PRI Construction Materials Technologies(TST6049) MSA-026-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) MSA-047-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) MSA-048-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) MSA-054-02-01.1 TAS 103 2020
TAS 110 2000
PRI Construction Materials Technologies(TST6049) MSA-056-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) MSA-057-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) MSA-060-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) MSA-060-02-02 TAS 110 2000
PRI Construction Materials Technologies(TST6049) MSA-062-02-01 ASTM D 1623 2017
PRI Construction Materials Technologies(TST6049) 1085T0002 TAS 110 2000
PRI Construction Materials Technologies(TST6049) 1085T0007 ASTM D 1623 2017
PRI Construction Materials Technologies(TST6049) 1085T0011 ASTM D 1623 2017
TAS 103 2020
MSA17001.2 FL17401-R5 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK MID-STATES ASPHALT AND CANT STRIP, INC
Self-Adhering Underlayments
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
QUIK-Stick Ice&Water QUIK-Stick Ice & Water Granular is an ASTM D 1970 self-adhesive underlayment
Granular constructed from SBS modified asphalt, a fiberglass mat reinforcement and surfaced
with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x
66.8-ft and has a nominal thickness of 50 mils.
QUIK-Stick Ice &Water Granular is permitted to be used as prescribed in FBC Section
1507.1.1 and Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure
on the roof deck shall be limited to a maximum 30 days.
QUIK-Stick Ice&Water QUIK-Stick Ice & Water Sand is an ASTM D 1970 self-adhesive underlayment
Sand constructed from SBS modified asphalt with a fiberglass mat reinforcement and surfaced
with sand. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft
and has a nominal thickness of 50 mils.
QUIK-Stick Ice & Water Sand is permitted to be used as prescribed in FBC Section
1507.1.1 and Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure
on the roof deck shall be limited to a maximum 30 days.
QUIK-Stick HT Smooth QUIK-Stick HT Smooth is an ASTM D 1970, TAS 103, and FRSA/TRI Florida High Wind
Concrete and Clay Tile Installation Manual, Sixth Edition compliant self-adhesive
underlayment constructed from SBS modified asphalt with a fiberglass mat
reinforcement and woven poly-fabric surface. The product is supplied in 2-sq. rolls with
nominal dimensions of 3-ft x 66.8-ft or 3-ft 3-in x 61-ft and has a nominal thickness of 60
mils.
QUIK-Stick HT Smooth (Woven Facer) is to be used as prescribed in FBC Section
1507.1.1 and Table 1507.1.1.1. QUIK-Stick HT is permitted to be used with
mechanically attached or adhered clay or concrete tile roofing using either DAP Touch 'n
Seal° Storm Bond Roof Tile Adhesive or DuPontTm TILE BONDTm Roof Tile Adhesive.
Exposure on the roof deck shall be limited to a maximum 180 days.
The maximum roof slope shall be 6:12 when used with clay or concrete tile installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
QUIK-Stick HT Pro QUIK-Stick HT Pro is an ASTM D 1970 self-adhesive underlayment constructed from
SBS modified asphalt with a fiberglass mat reinforcement and poly-fabric surface. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a
nominal thickness of 60 mils.
QUIK-Stick HT Pro is permitted to be used as prescribed in FBC Section 1507.1.1 and
Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure on the roof
deck shall be limited to a maximum 30 days.
QUIK-Stick FS QUIK-Stick FS is an ASTM D 1970 self-adhesive underlayment constructed from SBS
modified asphalt with a fiberglass mat reinforcement and textured film surface. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a
nominal thickness of 45 mils.
QUIK-Stick FS is permitted to be used as prescribed in FBC Section 1507.1.1 and Table
1507.1.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall
be limited to a maximum 30 days.
MSA17001.2 FL17401-R5 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK MID-STATES ASPHALT AND CANT STRIP, INC
Self-Adhering Underlayments
TECHNICAL SERVICES, LLC
PRODUCT APPLICATION
Min. Roof Slope: 2:12 or in accordance in with the FBC
Application: All underlayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the underlayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum 3" side
laps and minimum 6"end laps staggered min. 6-ft.from preceding course.
It is permissible to back nail the underlayment 12-inches on-center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment).
Min.Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underlayment System No.1 —QUIK-Stick HT Smooth only
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c.
Underlayment: QUIK-Stick HT Smooth shall be fully adhered to the optionally primed plywood deck.
Maximum Design -52.5 psf
Pressure:
MSA17001.2 FL17401-R5 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK MID-STATES ASPHALT AND CANT STRIP, INC
Self-Adhering Underlayments
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
1) This evaluation report is not for use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7th Edition (2020)as evidenced in the referenced documents submitted by the named manufacturer.
111111
�% Y R. 2020.10.16
�`��P•••�,�C'•E NSF.
No 74021
14:26:19
= ogmm•9ea er zaonery e.en:.a
= �= -0400'
STATE OF
!"bT••.A, O Zachary R. Priest, P.E.
R , C?N Florida Registration No. 74021
S�O(�A�� ���
Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
MSA17001.2 FL17401-R5 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.