0- 121,
Product Approval / 6USER:Public User St.Lucie County / ��pr (1, Pprri�lttin�
Product Approval Menu>Product or Application Search>gpolication List>Application Detail
• FL# FL25621-R1
Application Type Revision �o L U C Q RE C 0 UM,
T ,'
Code Version fu��CC
Application Status Approved 11��77
Comments RLE C®"Y
Archived W
i
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email - 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By James R Wally, PE
I Validation Checklist- Hardcopy Received
Certificate of Independence FL25621 R1 COI 26ga SnapMax Plywoo .pdf
Referenced Standard and Year(of Standard) Standard Year
TAS 100 1995
TAS 125 2003
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
N
Product Approval Method Method 1 Option D
Date Submitted 10/06/2020
Date Validated 10/16/2020
Date Pending FBC Approval 10/25/2020
Date Approved 12/16/2020
Date Revised 12/16/2020
C
Summary of Products
FL# Model, Number or Name Description
25621.1 01: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621 R1 II 26ga SnapMax plywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-97.25 Evaluation Reports
e e evaluation report FL25621 R1 AE 26ga SnapMax plywood.pdf
Created by Independent Third Party: Yes
25621.2 02: 032 Aluminum SnapMax on Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
Plywood on 15/32" (min) plywood or 3/4"wood plank
Limits of Us Installation Instructions
Approve or use in HVHZ: No FL25621 R1 II 032 SnapMax plywood.pdf
ed for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent'Third Party: Yes
Design Pressure: +N/A/-78.5 Evaluation Reports
Other: Refer to evaluation report FL25621 R1 AE 032 SnapMax plywood.pdf
Created by Independent Third Party: Yes
25621.3 j03:,,C32 Aluminum 12" SnapMax on Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
Plyood with 12" coverage on 15/32" (min) plywood or 3/4"wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621 R1 II 032 SnapMax 121n plywood.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent-Third Party: Yes
Design Pressure: +N/A/-69.25 Evaluation Reports
Other: Refer to evaluation report FL25621 R1 AE 032 SnapMax 12in plywood.pdf
Created by Independent Third Party: Yes
25621.4 04: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621 RI II 26ga SnapMax plywood D.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-121.75 Evaluation Reports
Other: Refer to evaluation report FL25621 R1 AE 269a SnapMax plywood D.pdf
Created by Independent Third Party: Yes
25621.5 05: 26ga SnapMax on Plywood HVHZ 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL25621 R1 II 26ga SnapMax plywood HVHZ.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent,Third Party: Yes
Design Pressure: +N/A/-176 Evaluation Reports
Other: Refer to evaluation report FL25621 R1 AE 269a SnapMax plywood HVHZ.pdf
Created by Independent,Third Party: Yes
25621.6 06: 24ga SnapMax on Plywood 24ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank ;
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621 R1 II 24ga SnapMax plywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-206 Evaluation Reports
Other: Refer to evaluation report FL25621 R1 AE 24ga SnapMax plywood.pdf
Created by Independent Third Party: Yes
25621.7 07: 032 Aluminum SnapMax on Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
' Plywood on 15/32" (min) plywood or 3/4"wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621 R1 II 032 SnapMax plywood d.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-168.5 Evaluation Reports
Other: Refer to evaluation report FL25621 R1 AE 032 SnapMax plywood d.pdf
Created by Independent Third Party: Yes
25621.8 08: 032 Aluminum SnapMax on Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
Plywood HVHZ on 15/32" (min) plywood;or 3/4"wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL25621 R1 II 032 SnapMax plywood HVHZ.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-175 Evaluation Reports
Other: Refer to evaluation report FL25621 R1 AE 032 SnapMax plywood HVHZ.pdf
Created by Independent Third Party: Yes
25621.9 09: 26ga 19'TopMax on Plywood 26ga (min)TopMax 1.5" nail strip with 19"coverage on 15/32"
- (min) plywood or 3/4" (min)wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621 R1 II 269a TopMax 19in &LAtood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-63.5 Evaluation Reports
Other: Refer to evaluation report FL25621 R1 AE 269a TopMax 19in P1Ywood.pdf
Created by Independent Third Party: Yes
25621.10 10: 032 Aluminum TopMax on Nominally 0.032" aluminum (or thicker)TopMax 1.5" nail strip
plywood HVHZ on 15/32" (min) plywood or 3/4"wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL25621 R1 II 032 TopMax plywood HVHZ.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-179.5 Evaluation Reports
Other: Refer to evaluation report FL25621 R1 AE 032 TopMax plywood HVHZ.pdf
Created by Independent Third Party: Yes
25621.11 11: 24ga TopMax on Plywood HVHZ 24ga (min)TopMax 1.5" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL25621 R1 II 24ga TopMax plywood HVHZ.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-153.5 Evaluation Reports
Other: Refer to evaluation report FL25621 RI AE 24ga TopMax plywood HVHZ.pdf
Created by Independent•Third Party: Yes
25621.12 12: 24ga 19"TopMax on Plywood 24ga (min)TopMax 1.5" nail strip with 19"coverage on 15/32"
HVHZ (min) plywood or 3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL25621 R1 II 24ga TopMax 19in plywood HVHZ.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-116.25 Evaluation Reports
Other: Refer to evaluation report FL25621 R1 AE 249a TopMax 19in plywood HVHZ.pdf
Created by Independent Third Party: Yes
25621.13 13: 032 Aluminum 19"TopMax on Nominally 0.032" aluminum (or thicker)TopMax 1.5" nail strip
plywood HVHZ with 19" coverage on 15/32" (min) plywood or 3/4" (min) wood
plank
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL25621 R1 II 032 TopMax 19in plywood HVHZ.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact,Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-166.75 Evaluation Reports
Other: Refer to evaluation report FL25621 R1 AE 032 TopMax 19in plywood HVHZ.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
i
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you;do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
CreditVCard
Safe
Securitymimucs-
i
i
i
i