Loading...
HomeMy WebLinkAboutAPPROVED, ENERGY CALCS & MANUAL J - 13929 ENCANTARDOFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST, LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Rorida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Typet1432.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft2 3. Number of units, if multiple family 7 b. Frame - Wood, Adjacent c. NIA R=11.0 208.00 ft2 R= ft2 4. Number of Bedrooms 3 d. NIA R= ft2 5. Is this a worst case? Yes 11. Ceiling Types (1783.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 T. Windows(151.4 sgft.) Description Area 12. Ducts R ft2 a. U-Factor: Sgl, U=1.02 111.36 ft2 a. Sup: Attic, Rat: Attic, AH: Attic 6 195 SHGC: SHGC=0.29 b. U-Factor: SgI, U=1.11 40.00 ft2 13. Cooling systems kBtuthr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0,285 a. Electric Heat Pump 34.8 HSPF:8.50 8, Skylights Area c. U-Factor.(AVG) NIA ft2 SHGC(AVG): NIA 15. Hot water systems 9. Floor Types (1753.0 sqft,) Insulation Area a. Electric Ca p: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features EF: 0.970 b. NIA R= ft2 None c. NIA R= ft2 16. Credits None Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49.38 PASS Total Baseline Loads: 50.69 I hereby certify that the plans and specifications covered by Review of the plans andiS this calculation are in compliance with the Florida Energy specifications covered by this ,y p Code. calculation indicates compliance ��;r'� = z,����•,r, with the Florida Energy Code. rrrr: ,.. %• :,':'_•H PREPARED BY: Before construction is completed W DATE: 1-12-2021 this building will be inspected for f �i compliance with Section 553.908 c 1 hereby certify that this building, as designed, is in compliance Florida Florida Statutes. ,� with the Energy Code., OWNEWI ENT' BUILDING OFFICIAL: DATE: t �- DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHFCKI IST RFPnRT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 W _� 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 W _— 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 fF ___ 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft' __ 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 fY __ 0 1 0 1/12/2021 1:15 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 It 0 1a0 ft2 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 588 fF 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN lift 0 209 it- _ 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft' _ 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft- 0 1 0 11Slab-On-Grade Edge Insulatio FOYER 9 It 0 92 ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft' ___ 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emift Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / tr # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Faming Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 fF 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft' 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft? 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft' 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 fl' 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 8' 0.1 Wood 10 Under Attic(Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft' 0.1 Wood 13 Knee Wall (Vented) DINING/GREAT 19 Blown 30 ft' 0.11 Wood WALLS Adjacent Space Cawty Width Height Sheathing Framing Solar Below _ t NE=>SW Exterior Concrete Block- Int InsMASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.3 0 _ 2 SW=>NE Exterior Concrete Block - Int InsEAASTER BE 4.1 7 0 8 0 56.0 ft- 0 0 0.3 0 3 NW=>SE Exterior Concrete Block - Int InsapASTER BE 4.1 14 0 8 0 112.0 ft- 0 0 0.3 0 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHFCKI IRT RFPnRT WALLS Adjacent Space Cavity Width Ft In Height Ft In A- Sheathing Framing Solar Below 4 NE=>SW Exterior Concrete Block - Int InsUASTER BA 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 5 NE=>SW Exterior Concrete Block- Int Insul M. BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.3 0 6 NE=>SW Exterior Concrete Block- Int InsEKEDROOM 2 4.1 12 0 8 0 96.0 w 0 0 0.3 0 7 SW=>NE Exterior Concrete Block - Int InsiDINING/GRE 4.1 30 0 8 0 240.0 ft' 0 0 0.3 0 -8 NW=>SE Exterior Concrete Block -Int InSBIINING/GRE 4.1 20 0 8 0 160.0 ft- 0 0 0.3 0 _ 9 SW=>NE Exterior Concrete Block- Int InsulKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.3 0 10 NE=>SW Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.3 0 11 SE=>NW Exterior Concrete Block - Int Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 _12 SW=>NE Exterior Concrete Block- Int Insul FOYER 4.1 1 0 8 0 8.0 ft' 0 0 0.3 0 _ 13 NE=>SW Exterior Concrete Block - Int InsBEDROOM 3 4.1 13 0 8 0 104.0 ft- 0 0 0.3 0 _14 SW=>NE Exterior Concrete Block - Int Insl1EDROOM 3 4.1 1 0 8 0 8.0 ft' 0 0 0.3 0 15 N=>S Garage Frame - Wood BEDROOM 3 11 26 8 208.0 W 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated FOYER None .39 3 3 6 8 21.7ft- WINDOWS Orientation shown is the entered orientation => chanced to Worst Case. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.02 0.29 Y 32.4 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>SW 5 Metal Low-E Single Yes 1.02 0.29 Y 6.9 ft' 1 ft 0 in 1 ft 4 in None None 3 NE=>SW 6 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft- 1 ft 0 in 1 ft 4 in None None 4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29 Y 39.8 ft 1 ft 0 in 1 ft 4 in None None 5 NW�SE 8 Metal Low-E Single Yes 1.11 0.27 Y 40.0 ft' 8 ft 0 in 1 ft 4 in None None 6 NE=>SW 13 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ftz 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft' 806 ft 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12 120.37 .0902 5 1 /12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtu/hr cfm 0.85 1 Sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / — Supply --- -- Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 195 ft= Attic 55 W Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablfe Ceiling Fans: 1Thermostafft:l1IN Feb Heat Heating `X1 Jan fX1 Feb Venting 77 IXI Mar Apr € toot fX1 DC� May ` + Jun i 1 Jul [ ] Aug fXI I 1 Sep j L 1 Oct ff Dec I[ ]] Jan [[ ]] Feb [[XX]l Mar ` l Jun [ ] Jul I 1 Aug [ 1 Sep lxJ Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft' 0 ft 0.3 MASTER BEDROO Default(81bs/sq.ft. ft' ft 0.3 WIC Default(8 lbs/sq.ft. ft' ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft' ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 LAUDRY Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 DINING/GREAT R Default(81bs/sq.ft. ft' ft 0.3 KITCHEN 1/12/2021 1:15 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 HALL Default(8 lbs/sq.fL ft- ft 0.3 FOYER Default 8lbs/s .ft. ft' ft 0.3 BEDROOM 3 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. x Owner: Jurisdiction: w Design Location: FL, Fort Pierce x O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped y pp ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maimain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be out neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind oininc And wirinc Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrirallphone box oi The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be d sprinklers sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voidsorinkler cover 2lates And walls or ceilmos Ire a. In aaamon, Inspenon or log wars snau De In accoraance with the provisions of ICL%40U. 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRe52020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft- 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 208.00 ft- c. N/A R= ft' 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft 6. Conditioned floor area (ft') 1753 b. Knee Wall (Vented) R=19.0 30.00 ft' 7. Windows** Description Area c. N/A R= ft' a. U-Factor. Sgl, U=1.02 111.36 ft= 12. Ducts, location & insulation level R ftz SHGC: SHGC�.29 a. Sup: Attic, Ret: Attic, AH: Attic 6 195 b. U-Factor. Sgl, U=1.11 40.00 ft' SHGC: SHGC=0.27 13. Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft' a. Central Unit 34.8 SEER15.00 SHGC: d. U-Factor. N/A tt' SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.850 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.285 8. Skylights Description Area - 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap: 40 gallons SHGC(AVG): N/A EF: 0.97 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ff' Credits (Performance method) None b. N/A R= ft= c. N/A R= ft' I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant feature Builder Signature: Date: �Q�\\ N Address of New Home: ity/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 wrightsofk® Project Summary ata: Entire House ay: QUICK CALCS, INC. 317 ST. LUCIE LN.,Fr.. PIERCE, FL 34946 PM.: 772466-6799 Fax 772466-6796 Emit: OUICKC4LCS@AOL.COM Project Information For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 Inside db 70 OF Inside db 75 F Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr4b Heating Summary Sensible Cooling Equipment Load Sizing Structure 21542 Btuh Structure 16420 Btuh Ducts 6191 Central vent (0 cfm) 0 Btuh Btuh Duds Central vent (0 cfm) 9337 0 Btuh Btuh none (none) Humidifigtion 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27734 Btuh Use manufacturers data n Infiltration Rate/swingg multiplier Equipmentload 0.95 sensible 24470 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2495 Btuh Ducts 2546 Btuh Central vent (0 cfin) 0 Btuh Heatingg Area Coolingg (none) (fl) 1753 1753 Equipment latent load 5041 Btuh Volume (fit") 16478 16478 Airchanges/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 29511 Btuh Equiv.AVF(dm) 104 55 Req. total capadtyat0.70SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536XO30 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 36 OF 8.5 HSPF 34600 Btuh@47-F 27 OF 1160 cfir 0.042 ctm/Btuh 0 in H2O Backup: Input=7kW, Output= 23009 Btuh, 100 AFUE Make Carder Trade CARRIERAIR CONDITIONING Cond 25HBC53WO30 coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Airflowfador 0.045 dm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.84 Calculations approved byACCAto meet all requirements of Manual J 8th Ed ® -F�- we ghts ft^ 2021-Jan1213:18:18 RigktSuLOUriwrsa1201919.021RSU08101 ...Drts\WngF Dft HVAC\WYNNE-THEWINDSORnp Calc=MJ6 Frok Doorfaces:N Pagel x wrightsofr Right-M) Worksheet Job., Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN.,Fr.. PIERCE, FL 34946 Phore: 772466-6799 Fax n2-466£796 Email: QUICKCALCSQAOL.COM 1 Room name Enfire House BEDROOM 2 EVosedval 207.6 It 41.0 it 3 Room height 9.4 ft d 9A ft heaV=l 4 Room dimensiore 5 Roomarea 74A z 20.0 ft 1753.0 ft2 280.0 ft- Ty Construdon U-value Or HTM Area (ft2) Load Area number (BWh%l2-°F) (BDJW or perimeter (ft) (BWh) or perimeter (ft) (BWh) Heat Cool Grass NIPS Cool Grass WP5 Heat Cool 6 13A-4= 0.143 n 4.00 2.55 649 5966 1517 66 66 263 167 1A-clom 1270 n 3556 34.77 15 03 522 0 0 0 0 4Ai2om 0.770 n 2156 19.31 38 05 730 0 0 0 0 W 13A-4= 0.143 ne 4.00 2.55 27 276 68 0 0 0 0 11 13A4= 0.143 a 4.00 2.55 141 1000 255 0 0 0 -0 �G �D IA-cl m 1270 a 3556 ST06 20 11 1741 0 0 0 0 11DO 0.390 a 10.92 11.31 27 219 238 0 0 0 0 W im fors 0.143 se 4.00 2.55 27 276 68 0 0 0 0 13A-0oa 0.743 s 4.00 2S5 536 5301 1349 1S8 188 753 479 1Acicm 1270 s 35.56 34.77 6 63 209 0 0 0 0 13A-4ors 1Actom 0.143 w 4.00 2.55320 2552 649 T 132 108 432 275 1A-ctom 1270 1270 w w 3556 35M 54.53 54.53 12 12 1 636 12 1 415 636 4A5-2om 0.770 w 21.56 45.63 41 1 20 654 18M 12 1 0 427 654 P 12C-Ow 0.091 - 2.55 128 254 2547 326 0 0 0 0 0 0 0 C F 16A-30md 22A-tpl 0.032 0.989 - 0.90 2.32 1753 17531 4067 280 280 251 650 - 27.69 0.00 1753 208 0 280 41 1135 0 6 c)AM e=moorli 397 488 Envelope loss'gain 18331 15285 3676 3349 12 a) Infilhafion 3211 905 729 205 b) Room a filation 0 0 0 0 13 Internal gains: Ompants@ 230 1 230 0 0 Applianoes/other 0 0 Subtabl(Iines6to13) 21542 16420 4405 3584 Lese>3umalioad 0 0 0 0 Lesiransfer 0 0 0 0 RedisOibufion 0 0 0 0 14 Sublotal 21542 164203554 4266 15 Dudloads 29% 57% 6791 9337 29% 57% 1266 2021 2027 Total room load 27734 25757 5671 5575 Airrequired(dm) 1160 11. 237 251 Calculations approved byACCAto meet all requirements of Manual J 8th Ed wr✓f9htsvlt' 2021-Jar+1213:18:18 RigttSut.S Urmrs1201919.021 RSU08101Aft Pager i ...DocvnertslWdgl HUAQWVNNE-THEWINDSORnp Caic=Ml8 ROrft Doorfaces:N wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN.,FT. PIERCE, FL 34946 RIM: 772-456-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC MASTER BOTH 2 Fdxall 0 ft 9.0 ft 3 Room height 9.4 ft heatlmol 9.4 ft heaV000l 4 Room dimes m 5 Room area 7.0 x 9.0 ft 7.0 x 9.0 ft 63.0 ft' 63.0 iF Ty Construction 1-1-value Or HTM Prey (T) Load number (BWhfiF-*F) (ftw) or perimeter It (Btuh) orperimeter(t) (B1uh) Heat Cool Gross N/P5 Heat Cool Gros N/P/S Heat Cool 6 VF 13A-4ors 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 I�--.GG 1A-dw 1270 n 3556 34.77 0 0 0 0 0 0 0 0 4A>2om 0.770 n 2156 1931 0 0 0 0 0 0 0 0 W 13A4ors 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 13A4= 0.143 a 4.00 2.55 0 0 0 0 0 0 D 1Ac1om 1270 a 3556 87.06 0 0 0 0 0 0 o 0 0 11DO 0.390 a 1092 11.31 0 0 0 0 0 0 0 0 W 13AA-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 85 85 339 215 1Aolom 127o s 3556 34.77 0 0 0 0 0 0 0 0 13A4c s 0.143 w 4.00 2.55 0 0 0 0 0 0 1Actwn 1270 w 35M 54M 0 0 0 0 0 0 0 0 1Aciorrl 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 0 P 12C-0sv 0.091 - 2S5 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 090 232 63 53 56 146 63 63 56 146 F 22A-fil 0.989 - 27.69 0.00 63 0 0 0 63 9 249 0 6 c)AED ex ursim -10 -28 Envelope losstgain 56 136 644 334 12 a) IMiltrafion 0 0 160 45 b) Roomeenblation 0 0 0 0 13 Intemal gains O=panls@ 230 0 0 0 0 ApPlianoadother 0 0 Subtotal (lirles6to 13) 56 136 1 804 379 load LesIransf 0 0 D 0 Lestra"rral r 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 136 804 379 15 Dud loads 29% 57% 16 77 29% 57% 231 216 Total room load 73 214 1036 595 Airrequired(dm) 3 10 43 27 Caloulabons approved bvACCAto meet all reouirements of Manual J 8th Ed wri9l+tsoTC^ 2021Jarv1213:18:18 '� PogkSutel=J Udversa1207979.027 RSU08101 Page2 ...Doa rts\Wdgttsoft HVAOWYNNE-THEWINDSORnp Calc=W8 Frort Doorfaoes N wrightsoW Right-J@ Worksheet Job: Entire House °fit QUICK CALCS, INC. By. 317 ST. LUCIE LN., FL PIERCE, FL 34946 PMre:772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name M BATH KITCHEN 2 Evomdwall 8.0 ft 8.0 ft 3 Room height 9.4 It heaVccol GA It heaVmol 4 Room dim. 7.0 x &0 ft 1.0 x 172.0 ft 5 Room area 56.0 f? 172.0 T Ty Construction U-value Or HTM Anm Load number (BluhfitkT) (BtuhffF) or perimeter (ft) (Bbuh) or�perimater (ft) (BNh) Heat Cool Gras IN/P/S Heal Cool Gros N/P/S Heat Cool 6lj�j13A4= 0.143 n 4A0 2.55 0 0 0 0 0 0 0 0 1A-dom 1270 n 3556 34.77 0 0 0 0 0 0 0 0 4A5-2on 0.770 n 2156 1931 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 re 4.00 2.55 0 0 0 0 0 0 0 0 11 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 a 3556 87.06 0 0 0 0 0 0 0 0 ������^^^ 11DO 0390 a 1092 1131 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1A/ 13Adacs 0.143 s 4.00 2.55 75 69 277 176 0 0 0 0 t-G 1Actom 1270 s 3556 34.77 6 6 213 209 0 0 - 0 0 13A-4ocs 0.143 w 4A0 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 G to-dom 1270 w 3556 54M 0 0 0 0 0 0 0 0 4A5.2om 0.770 w 21M 45.63 0 0 0 0 0 0 0 0 p 12C-Ow OA91 2S5 128 0 0 0 0 75 75 192 96 C 16A-30md 0.032 - 0.90 2.32 56 56 60 130 172 172 154 399 F 22A-tpl 0.989 - 27.69 0.00 56 8 222 0 172 8 222 0 6 c)AEDe rsioi -38 -34 Envelope losdgain 762 477 567 462 12 a) Infiltration 142 40 0 0 b) Rcomvenflabon 0 0 0 0 13 Intemalgaim Omtpants@ 230 0 0 0 0 Applianoes(other 0 0 Subtttal(linesft13) 904 517 567 462 Lesse)ftmalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Submlal 904 517 567 462 15 Dudloads 29% 57% 260 294 29% 570% 163 263 Total room load 1164 811 730 725 Air required(dm) 49 37 31 33 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. -HwrSoft sofP[' 2021-Jar✓121318:18 A A RgllSute&Uriversa1201919.021 RSU08101 Page3 ...Dod r6sWdghtsaftHVAQWYNNE-THEWINDSORnp Calc=MI6 Fror¢Doorfaces:N �11 wdghtsoit Right-J@ Worksheet Jcb: Entire House Date: QUICK CALCS, INC. By. 317 ST LUCE LN, Fr. PIERCE, FL 34946 Phoe:772-066-6799Fax772-466-6796 Email: CUrXCALCS@AOL.COM 1 Room name BATH BEDROOM2 2 5posd wall 5.0 It 4261t 3 Room height 9.4 It heaYcool 9.4 It heatlbod 4 5 Room dimensions Roomarea 9A x 5.0 ft 45.0 iF 7A x 204.0 It 204A fF Ty Coon U-value or HTM Area LoadLoad number (Bbjhhf-°F) (Bkjw or P� meer (� (BW) or PadmeVcr (ft) (BWh) H;t Cad Gross NIPS Heat Cool Gros; NIPS Heat Cod 6 Vp 13AA= 0.143 n 4A0 2,55 47 47 188 120 132 132 527 335 LAG 1Ac1an 4A5-2am 1270 0.770 n n 35.56 2156 34.77 1931 0 0 0 0 0 0 0 a 0 0 0 0 -a 0 0 0 W Yy 11 13AAM 13440cs 0.143 0.143 ne a 4A0 4A0 255 255 0 0 0 0 0 0 0 0 27 85 27 65 106 259 68 164 IF--DG 1Aclom 11DO 13A4ocs 1270 0390 0.143 e a se 3556 1092 410 87.06 - 1131 255 0 0 0 0 0 0 0 0 0 0 0 0 20 0 27 1 -0 27 711 - 0 106 1741 0 - 68 w t—G 13A4ats 0.143 5 4Ao 255 0 0 0 0 132 132 627 335 1Ac1an 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13AAM 1A41om 1A-Gl= 0.143 1270 12M w w w 4A0 35M 35.56 255 54.63 54M 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 0 0 0 P 4A52om 12C-0sx 0.770 OA91 w - 2156 255 45.63 128 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16A30md ODM - 090 232 45 45 40 104 204 204 183 473 F 22A4pI 0989 - 27.E 0.00 45 5 138 0 204 43 1179 0 6 c)AED excursion -17 -99 Envelope loss/gain 367 207 3599 3085 12 a) Infiltrafion 89 25 758 214 b) Room erdlafion 0 0 0 0 13 Intemmal gains Ooupants@ 230 0 0 0 0 Appliances/ottw 0 0 Subtotal(Iines6to13) 456 232 4357 3:w Lese)damd load 0 0 0 0 Lestarlsfer 0 0 0 0 Redistibutlon 0 0 0 0 14 Subtotal 456 232 4357 3299 15 Dudloads 29% 57% 131 132 29% 57% 1252 1876 Tad room load 587 364 5609 5175 Atrequired(&n) 25 16 235 233 Calculations aDDroved bvACCAto meet all requirements of Manual J 8th Ed wrigtitsot^C' 2021Ja 1213:18:18 Mgft-SLite@LhiWM1201919.021RSLWIOI Pa984 ...DoamertAW69Wti ftFNAQWYNNE-THEWINDSORItp Calc=M1B Front Doorfaces:N wrightsoft- Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Rona: 772-466-6799 Fax 772-466£796 Email: QUICKCALCS@AOL.COM 1 Room name ENTRY LAUNDRY 2 EtPosadwall 18.0 R 13.0 it 3 Room height 9.4 Itheatbool 9.4 itheaVbool 4 Room dimensions 1.0 x 92.0 R 7.0 x 6.0 It 5 Room area 92.0 ff 42.0 fF Ty Construction U-va7-27JB9 Or HTM Area number (SUKn Pulle) or perimeter (1t) (Btuh) oorperime� (ft) (Bluh) Heat Cool Gross NP5 Heat Cool Gross N/P/S Heat Ccol 6 Y)/ 13A-4= 43 n 4.00 2.55 0 0 0 0 0 IA-clom 70 n 3556 34.77 0 0 0 0 0 0 0 0 0 0 1�----GG 4A5-2om 70 n 21.56 19.31 0 0 0 0 0 0 0 W 13A4.ois 43 ne 4.00 2.55 0 0 0 0 0 p p 11 13A4os 43 a 4.00 2S5 56 35 142 90 0 0 � 1AClcm 70 a 3556 87.06 0 0 0 0 0 0 0 0 11DO 90 a 10.92 11.31 21 21 229 238 0 0 0 0 0 0 w 13A4o s 3 se 4.00 2.55 0 0 0 0 0 0 0 13A4ors 3 s 4.00 2.55 0 0 0 0 0 1Ac1om o a as.ss 34.n o 0 0 56 0 0 0 �0 1 0 13A-0ocs 3 w 4.00 2.55 0 0 0 0 0 1Aclom 0 w 35.55 54.53 0 0 0 0 0 0 0 1A-clom 0 w 3556 5453 0 0 0 0 0 0 a 0 4A5-2om 0 w 21.56 45.63 0 0 0 0 0 0 0 P 12C-0sv 1 - 2.55 128 113 113 280 145 66 66 168 0 84 C 16ASOmd 2 - 0.90 2.32 92 92 82 213 42 42 38 97 F 22ltyl 9 - 27.69 0.00 92 18 498 0 42 13 360 0 6 c)AED e>musion -24 Envelope los4gain 1239 637 1 791 301 12 a) Infiltraton 107 30 107 30 b) Roomeenfilation 0 0 0 0 13 Internal gains: Ocupants@ 230 0 D 0 0 Applianordother 0 0 Subtotai(lines6to13) 1346 667 1 898 331 Lessedemalload 0 0 0 0 Le tnmsrer 0 0 0 0 Rediskibuton 0 0 0 0 14 SubhFal 1346 667 898 331 15 Ductioads 29% 57% 387 379 29% 57% 258 188 Total room load 1733 1047 1156 920 Airrequired(dm) 72 47 48 23 Calculations approved byACCAto meet all requirements of Manual J 8th Ed wr�gh�o7'e- 2021-JaM213:18:18 Ri9FtSutc-0Uriversal 201919.021 RSU08101 ...Doa rOWngtZoftHUACWYNNE-THEWINDSORnMI p Caic=6 Fror¢Doorfaces N Page 5 > wrightsoft- RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE UN., FL PIERCE, FL 34946 Plnre: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AQL.COM 1 Room name GREATiDINWG Room7 2 Bposadwall 50A It 13.0 It 3 Room height 9.4 It heaV000l 9A It heaVmol 4 Room dimensons 1.0 x 567.0 It 13.0 x 13D ft 5 Room area 567.0 ft' 169.0 it, Ty Constuction U-value Or HTM Area (fF) Load Area Load number (BWh4F-°F) (BWhAM or perimeter (ft) (Btuh) or perimeter (ft) (Bbih) Heat Cool Gros N/P/S Heat Cool Gross NIPS Heat Cool 6 VII 13A4= 0.143 n 4.00 255 282 244 978 622 122 107 429 273 tAcicm 1270 n 35.56 34.77 0 0 0 0 15 0 533 522 `ECG' 4A52om 0.770 n 21.56 19.31 38 0 815 730 0 0 0 0 W 13A4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 13A4o s 0.143 a 4.00 2,55 0 0 0 0 0 0 0 0 1Aclom 1270 a 3556 87.06 0 0 0 0 0 0 0 0 D 11DO 0.390 a 10.92 1131 0 0 0 0 0 0 0 0 W 13A4o s 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 W 13AA= 0.143 s 4A0 255 0 0 0 0 0 0 0 0 --a 1Aclom 1270 5 3556 34.77 0 0 0 0 0 0 0- 0 13A4= 0.143 w 4.00 2.55 188 147 589 375 0 0 0 0 1A,1om 1270 w 3556 5453 0 0 0 0 0 0 0 0 1Aclom 1270 w 3556 54.63 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 41 2 880 1862 0 0 0 0 P 12C-Ow OA91 - 2.55 128 0 0 0 0 0 0 0 0 C 16Aa0md 0.032 - 0.90 2.32 567 567 508 1315 169 169 151 392 F 22A-tpl 0.989 - 27.69 0.00 567 50 1395 0 169 13 360 0 6 c)AED exarrsion - 307 -100 Envelope loslgain 51541 521C 1474 1086 12 a) Infiltration 889 251 231 65 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 1 230 Applianceslother 0 0 Subtotal(lines6 to 13) 6043 5461 1705 1381 Les eMemal load 0 0 0 0 Lestransrer 0 0 0 0 Redishibuton 0 0 0 0 14 Subtotal 6043 5461 1705 1381 15 Dud loads 29% 57% 1737 3105 29% 57% 490 785 Total room load 7780 8566 2195 2167 Airrequired(dm) 325 386 92 98 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. wrl9MssoR` ...RgH9.021 RS2021-Jarv1213:18:18 Ak Dowr5\WngOoftHVAQWYNNE-THEWINDSOPnp Calc=M8 FrortDoorfareS:N Page - wrightsof� Duct System Summary Job: _ Entire House Sy. QUICK CALCS, INC. 317 ST. LUCIE LN, FT. PIERCE, FL 34945 Phone:772-46"799 Fax 772-46"796 Email: QUICKCALCS a�i OL.COM For: WYNNE DEVELOPMENT THE WIN DSOR, FT. PIERCE, FL External static pressure Pressurelosses Available stalic pressure Supply/ return available pressure Lowestfl iction rate Actual airflow Total effective length (TEL) Heating 0 in H2O 0 in H2O 0 in H2O 0.00010.000 in H2O 0 in/100ft 1160 cfm Oft Cooling 0 in H2O 0 in H2O 0 in H2O 0.00010,000 in H2O 0 in/100ft 1160 clirl Name Design (13tuh) Htg (cfm) Clg (dm) Design FR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 364 25 16 0 0 Ox 0 ShMt 0 0 BEDROOM c 2788 119 126 0 0 Ox 0 ShMt 0 0 BEDROOM2 h 2587 117 117 0 0 Ox0 ShMt 0 0 BEDROOM2-A h 2587 117 117 0 0 Ox0 ShMt 0 0 BEDROOM -A c 2788 119 126 0 0 Ox 0 ShMt 0 0 ENTRY h 1047 72 47 0 0 Ox 0 ShMt 0 0 GREATIDINING c 2855 108 129 0 0 Ox 0 ShMt 0 0 GREATIDINING-A C 28555 108 129 0 0 OX 0 ShMt 0 0 GREATlDINING-B C 2855 108 129 0 0 OX 0 ShMt 0 0 KrrCHEN c 725 31 33 0 0 Ox 0 ShMt 0 0 LAUNDRY h 620 48 23 0 0 Ox 0 ShMt 0 0 M. BATH h 811 49 37 0 0 Ox 0 ShMt 0 0 MASTERBATH h 595 43 27 0 0 Ox0 ShMt 0 0 Room? c 2167 92 98 0 0 Ox 0 ShMt 0 0 WIG C 214 3 10 0 0 Ox0 ShMt 0 0 Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 ShMt %- Ad- wrj Jhtsoft- 2021-Jarr1213:18:19 A_ •w�- +� wA- 4� R Right -Sate® Universal 201919.021 RSU08101 page 1 ACM ...DoamertslWrigFtsoftHVACIWYNNE-THEWINDSOR.rnp Calo=MJ8 Frorl Doorfams: N