HomeMy WebLinkAboutAPPROVED PV Plans Stamped - 110230_ Nutter, Sherry(1)PHOTOVOLTAIC ROOF MOUNT SYSTEM7603 NORTH BLVD, FORT PIERCE, FL 34951 USAREVDATEDESCRIPTIONVERSIONUR10/21/2021INITIAL RELEASESHEET NAMESHEET NUMBERPV-1 PROJECT NAMENUTTER, SHERRY
7603 NORTH BLVD,
FORT PIERCE, FL 34951 USA
APN# 130160703310009
AHJ: ST. LUCIE COUNTYSHEET SIZEANSI B 11" X 17"FREEDOM FOREVERELECTRICAL CONTRACTOR NO:JOB ID: F110230GREG ALBRIGHT43445 BUSINESS PARK DRIVESUITE110, TEMECULA CA 92590TEL: (888) 557-6431CERTIFIED ELECTRICALCONTRACTOR EC13008056CERTIFIED ROOFINGCONTRACTOR CCC1332814SYSTEM SUMMARY:HOUSE AERIAL VIEW:ARRAY LOCATIONS42 MODULES-ROOF MOUNTED - 12.18 kWDC, 10.0 kWACSITE LOCATION ANDHOUSE AERIAL VIEWTABLE OF CONTENTSPV-1SITE LOCATION AND HOUSE AERIAL VIEWPV-2SITE PLANPV-2AROOF PLAN WITH MODULES LAYOUTPV-3ROOF MOUNTING DETAILSPV-3AROOF MOUNTING DETAILSPV-4ELECTRICAL LINE DIAGRAMPV-5NOTES AND EQUIPMENT LISTPV-6WARNING LABELS & PLACARDPV-7OPTIMIZER CHARTPV-8SAFETY PLANPV-9JOB HAZARD ANALYSISTHIS PROJECT COMPLIES WITH THE FOLLOWING:2020 7TH EDITION FLORIDA BUILDING CODE: BUILDING2020 7TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL2020 7TH EDITION FLORIDA BUILDING CODE: MECHANICAL2020 7TH EDITION FLORIDA BUILDING CODE: PLUMBING2020 7TH EDITION FLORIDA BUILDING CODE: FUEL GAS2020 7TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION2020 7TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING2020 7TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY2020 7TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)2017 NATIONAL ELECTRIC CODE (NEC)AS ADOPTED BY ST. LUCIE COUNTYGOVERNING CODES:CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUMCODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING ASREQUIRED BY FIELD CONDITIONS.ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TOTHE MAXIMUM EXTENT POSSIBLE.INSTALLATION NOTES:·PV WIRE SHALL BE USED ON DC RUNS FORUNGROUNDED/TRANSFORMERLESS INVERTERS.·INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TOCOMMENCING WORK.·EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS·DIG ALERT TO BE CONTACTED AND COMPLIANCE WITHEXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACESITE LOCATION:WEATHER LOADING:WIND SPEED :152 MPHGROUND SNOW LOAD :0 PSFSYSTEM SIZE (DC) : STC: 42 X 290 = 12180.00W DC : PTC: 42 X 267.9 = 11251.80W DCSYSTEM SIZE (AC) : 10000W ACMODULES : 42 X REC SOLAR REC290TP2 (290W)OPTIMIZERS : 42 X SOLAREDGE P340INVERTER : SOLAREDGE SE10000H-USRGMROOF : COMP SHINGLETILT : 20° PITCHAZIMUTH : 91°, 181°, 01°, 271°, 91°, 91°& 181°RAFTER/TRUSS SIZE : 2"X4" TRUSSES @ 24" O.C.ATTACHMENT TYPE : UNIRAC SFM INFINITYMAIN SERVICE PANEL : (E) 150A MSP WITH (E) 150A MAIN BREAKER ON TOP FEEDINTERCONNECTION : LINE SIDE TAP IN MSPFUSE RATING : 60 AMPSUTILITY : FPL - FLORIDA POWER & LIGHTPROJECT SITE
~91.81'~151.20'~91.81'~151.20'35'-0"6'-10"53'-8"18'-6"JBMSPUMACDINVSITE PLANREVDATEDESCRIPTIONVERSIONUR10/21/2021INITIAL RELEASESHEET NAMESHEET NUMBERPV-2 PROJECT NAMENUTTER, SHERRY
7603 NORTH BLVD,
FORT PIERCE, FL 34951 USA
APN# 130160703310009
AHJ: ST. LUCIE COUNTYSHEET SIZEANSI B 11" X 17"FREEDOM FOREVERELECTRICAL CONTRACTOR NO:JOB ID: F110230GREG ALBRIGHT43445 BUSINESS PARK DRIVESUITE110, TEMECULA CA 92590TEL: (888) 557-6431CERTIFIED ELECTRICALCONTRACTOR EC13008056CERTIFIED ROOFINGCONTRACTOR CCC1332814SITE PLANSCALE: 1/16" = 1'-0"ROOF AREA : 2932.08 SQ FTLEGEND- UTILITY METERMSP- MAIN SERVICE PANEL- AC DISCONNECT- JUNCTION BOX- INVERTER- VENT, ATTIC FAN(ROOF OBSTRUCTION)- CONDUITUMACDINVJB(E) 150A MAIN SERVICE PANELWITH (E) 150A MAIN BREAKER(E) UTILITY METER(N) 60A FUSED AC DISCONNECT(SQUARE DU222NRB)(N) SOLAREDGE SE10000H-USRGMINVERTER(N) JUNCTION BOX- SETTBACK24" SETTBACK
ROOF DESCRIPTIONROOF TYPECOMP SHINGLE ROOFROOFROOFTILTAZIMUTHTRUSSESSIZETRUSSESSPACING#120°91°2"x4"24" O.C.#220°181°2"x4"24" O.C.#320°01°2"x4"24" O.C.#420°271°2"x4"24" O.C.#520°91°2"x4"24" O.C.#620°91°2"x4"24" O.C.#720°181°2"x4"24" O.C.24" SETTBACK24" SETTBACK24" SETTBACK
NORTH BLVDROOF #1(05) REC SOLAR REC290TP2 (290W)MODULESROOF #2(11) REC SOLAR REC290TP2 (290W)MODULESROOF #3(12) REC SOLAR REC290TP2 (290W)MODULESROOF #4(10) REC SOLAR REC290TP2 (290W)MODULESONE- STORYHOUSEEXISTINGDRIVEWAY(E) TREES (TYP.)(E) PROPERTY LINEROOF #5(02) REC SOLAR REC290TP2 (290W)MODULESROOF #6(01) REC SOLARREC290TP2 (290W)MODULESROOF #7(01) REC SOLARREC290TP2 (290W)MODULES24" SETTBACK24" SETTBAC
K
24" SETTBACK24" SETTBACK2
4
"
SE
T
TBAC
K24" SETTBACK24" SE
T
T
B
A
C
K
24" SETTBACK24" SETTBACK24" SETTBACK
6'-3"16'-8"10'-11"18'-11"11'-4"6'-9"14'-5"22'-3"3"5'-3"6'-9"3'-2"13'-8"7"JBMSPUMACDINV
9'-8"22'-3"14'-1"
9'-9"8'-4"5'-6"7'-5"1'-0"3'-3"
5'-9"REVDATEDESCRIPTIONVERSIONUR10/21/2021INITIAL RELEASESHEET NAMESHEET NUMBERPV-2A PROJECT NAMENUTTER, SHERRY
7603 NORTH BLVD,
FORT PIERCE, FL 34951 USA
APN# 130160703310009
AHJ: ST. LUCIE COUNTYSHEET SIZEANSI B 11" X 17"FREEDOM FOREVERELECTRICAL CONTRACTOR NO:JOB ID: F110230GREG ALBRIGHT43445 BUSINESS PARK DRIVESUITE110, TEMECULA CA 92590TEL: (888) 557-6431CERTIFIED ELECTRICALCONTRACTOR EC13008056CERTIFIED ROOFINGCONTRACTOR CCC1332814ROOF PLAN WITHMODULES LAYOUTROOF PLAN WITH MODULES LAYOUTSCALE: 3/32" = 1'-0"LEGEND- UTILITY METERMSP- MAIN SERVICE PANEL- AC DISCONNECT- JUNCTION BOX- INVERTER- VENT, ATTIC FAN(ROOF OBSTRUCTION)- CONDUITUMACDINVJBNOTES:1. EMT CONDUIT ATTACHED TO THE ROOFUSING CONDUIT MOUNTS2. ATTACHED CLAMPS AT 25% FROM THEEDGE AND 50% FROM THE CENTER OF THEMODULES3. JUNCTION BOX IS MOUNTED TO THE RAIL.ROOF AREA : 2932.08 SQ FTARRAY AREA & ROOF AREA CALC'SROOF# OFMODULESARRAYAREA(Sq. Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVERED BYARRAY (%)#10589.81340.4226.38#211197.59670.7629.46#312215.55613.4235.14#410179.62481.5037.30#50235.92187.3219.18#60117.96152.7211.76#70117.96103.4817.36ROOF DESCRIPTIONROOF TYPECOMP SHINGLE ROOFROOFROOFTILTAZIMUTHTRUSSESSIZETRUSSESSPACING#120°91°2"x4"24" O.C.#220°181°2"x4"24" O.C.#320°01°2"x4"24" O.C.#420°271°2"x4"24" O.C.#520°91°2"x4"24" O.C.#620°91°2"x4"24" O.C.#720°181°2"x4"24" O.C.ZONE 3ZONE 2ZONE 1(E) 150A MAIN SERVICE PANELWITH (E) 150A MAIN BREAKER(E) UTILITY METER(N) 60A FUSED AC DISCONNECT(SQUARE DU222NRB)(N) SOLAREDGE SE10000H-USRGMINVERTER(N) JUNCTION BOXROOF #1(05) REC SOLAR REC290TP2 (290W)MODULESROOF #3(12) REC SOLAR REC290TP2 (290W)MODULESROOF #4(10) REC SOLAR REC290TP2 (290W)MODULESROOF #5(02) REC SOLAR REC290TP2 (290W)MODULESROOF #7(01) REC SOLAR REC290TP2 (290W)MODULES24" SETTBACK24" SETTBACKROOF #2(11) REC SOLAR REC290TP2 (290W)MODULESROOF #6(01) REC SOLAR REC290TP2 (290W)MODULES- SETTBACK2
4
"
SE
T
TBACK24" SETTBACK24" SETTBACK2
4
"
S
E
T
T
B
A
C
K24" SETTBACK24" SETTBACK24" SETTBACK24
"
S
E
T
T
B
A
C
K
24" SETTBACK
REVDATEDESCRIPTIONVERSIONUR10/21/2021INITIAL RELEASESHEET NAMESHEET NUMBERPV-3 PROJECT NAMENUTTER, SHERRY
7603 NORTH BLVD,
FORT PIERCE, FL 34951 USA
APN# 130160703310009
AHJ: ST. LUCIE COUNTYSHEET SIZEANSI B 11" X 17"FREEDOM FOREVERELECTRICAL CONTRACTOR NO:JOB ID: F110230GREG ALBRIGHT43445 BUSINESS PARK DRIVESUITE110, TEMECULA CA 92590TEL: (888) 557-6431CERTIFIED ELECTRICALCONTRACTOR EC13008056CERTIFIED ROOFINGCONTRACTOR CCC1332814MOUNTING DETAIL ROOF MOUNTING DETAILSSCALE: NTS.SFM TRIMRAIL(E) ROOF MEMBRANEUNIRAC SLIDERS ANDTRIMRAIL ROOF ATTACHMENTS(E) BUILDINGSTRUCTURE5/16" STAINLESS STEEL LAG BOLTWITH 2-1/2" MIN. EMBEDMENTAND FLAT WASHER2.5" UNIRAC TRIMRAILFLASHING(E) ROOFMEMBRANEUNIRAC SLIDERS(E) BUILDING STRUCTURE5/16" STAINLESS STEEL LAG BOLTWITH 2-1/2" MIN. EMBEDMENTAND FLAT WASHERFLASHING2.5" MIN.EMBEDMENTPV MODULEPV MODULE2.5" MIN.EMBEDMENTMAX ATTACHMENT SPAN 48" STAGGERED
ROOF#1ROOF#2ROOF#3REVDATEDESCRIPTIONVERSIONUR10/21/2021INITIAL RELEASESHEET NAMESHEET NUMBERPV-3A PROJECT NAMENUTTER, SHERRY
7603 NORTH BLVD,
FORT PIERCE, FL 34951 USA
APN# 130160703310009
AHJ: ST. LUCIE COUNTYSHEET SIZEANSI B 11" X 17"FREEDOM FOREVERELECTRICAL CONTRACTOR NO:JOB ID: F110230GREG ALBRIGHT43445 BUSINESS PARK DRIVESUITE110, TEMECULA CA 92590TEL: (888) 557-6431CERTIFIED ELECTRICALCONTRACTOR EC13008056CERTIFIED ROOFINGCONTRACTOR CCC1332814MOUNTING DETAILROOF#5ROOF#4ROOF#6ROOF#7
REVDATEDESCRIPTIONVERSIONUR10/21/2021INITIAL RELEASESHEET NAMESHEET NUMBERPV-4 PROJECT NAMENUTTER, SHERRY
7603 NORTH BLVD,
FORT PIERCE, FL 34951 USA
APN# 130160703310009
AHJ: ST. LUCIE COUNTYSHEET SIZEANSI B 11" X 17"FREEDOM FOREVERELECTRICAL CONTRACTOR NO:JOB ID: F110230GREG ALBRIGHT43445 BUSINESS PARK DRIVESUITE110, TEMECULA CA 92590TEL: (888) 557-6431CERTIFIED ELECTRICALCONTRACTOR EC13008056CERTIFIED ROOFINGCONTRACTOR CCC1332814ELECTRICAL LINEDIAGRAMELECTRICAL LINE DIAGRAMSCALE: NTSDCAC#2#1#14#2#1#143/4" EMT CONDUIT(3) #10 AWG THWN-2 + RED(3) #10 AWG THWN-2 - BLACK(1) #10 THWN-2 GND(N) JUNCTIONBOX#2#1#14(3) #10 AWG PV WIRE + RED(3) #10 AWG PV WIRE - BLACK(1) #6 BARE CU GND(N) SOLAREDGE SE10000H-USRGMOUTPUT: 42A, 240 VAC,NEMA 3R, UL LISTED, INTERNAL GFDIWITH INTEGRATED DC DISCONNECTG(14) MODULES IN STRING #1(14) MODULES IN STRING #2(14) MODULES IN STRING #3(42) REC SOLAR REC290TP2 (290W) MODULES(42) SOLAREDGE P340 POWER OPTIMIZERS(03) STRINGS OF 14 MODULES CONNECTED IN SERIES PER STRINGSYSTEM SIZE:- 42 x 290W = 12.18 kWDCSYSTEM SIZE:- 01 x 10000W = 10.0 kWACNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS- CONNECT TO PREMISES GEC SYSTEMCONDUIT RUNS 7/8" ABOVE ROOFMAX DC OPTIMIZER OUTPUT CURRENT PER STRING CIRCUIT151.2518.75FUSES SIZINGMAX CONTINOUS OUTPUT CURRENT 42A @ 240V421.2552.560A BREAKER-OKSEE 705.12(B)(2)(3)(b) OF 2017 NEC1501150A ALLOWABLE BACKFEED VIA TABCONDUCTOR AMPACITY DE-RATE CALCULATIONLOCATIONWIRELOCATIONCONDUCTORQUANTITYCIRCUITCONDUCTORSIZENEC FACTORSTABLE 310.15(B)(16)ALLOWABLEAMPACITYNEC FACTORS TABLE310.15(B)(2)(a) AMBIENTTEMPERATURECORRECTIONADJ.CONDUCTORAMPACITY @90°CCONDUIT FILLCORRECTION PER310.15(B)(3)(a)ARRAY TO JUNCTION BOX(PER STRING)ROOF/FREE-AIR210400.9638.401.00JUNCTION BOX TO INVERTERWALL610400.9630.720.8INVERTER TO POIWALL36750.9672.001.00L150AEXISTINGGROUNDINGSYSTEM UTILITY METER1-PHASE, 3-W,120V/240V, 60HzLINE SIDE TAP(E) MAIN BREAKER150A/2P, 240V (E) MAIN SERVICE PANEL,150A RATED, 120/240VGNNL2L1L2L160A FUSES (3) #6 AWG THWN-2(1) #10 AWG THWN-2 CU GND3/4" EMT CONDUITSOLAREDGE P340 POWER OPTIMIZERRATED DC INPUT POWER - 340 WATTSMAXIMUM INPUT VOLTAGE - 48 VDCMPPT RANGE - 8 TO 48 VDCMAXIMUM INPUT CURRENT - 13.75 ADCMAXIMUM OUTPUT CURRENT - 15 ADC STRINGLIMITATIONS - 8 TO 25 OPTIMIZERS,6000 WATTS STC PER STRING MAXIMUMSOLAREDGE OPTIMIZERS HAVE INTEGRATEDRAPID SHUT DOWN(N) AC DISCONNECT 60AFUSED,VISIBLE LOCKABLELABELED, WITH 60A FUSES,240 VAC
REVDATEDESCRIPTIONVERSIONUR10/21/2021INITIAL RELEASESHEET NAMESHEET NUMBERPV-5 PROJECT NAMENUTTER, SHERRY
7603 NORTH BLVD,
FORT PIERCE, FL 34951 USA
APN# 130160703310009
AHJ: ST. LUCIE COUNTYSHEET SIZEANSI B 11" X 17"FREEDOM FOREVERELECTRICAL CONTRACTOR NO:JOB ID: F110230GREG ALBRIGHT43445 BUSINESS PARK DRIVESUITE110, TEMECULA CA 92590TEL: (888) 557-6431CERTIFIED ELECTRICALCONTRACTOR EC13008056CERTIFIED ROOFINGCONTRACTOR CCC1332814NOTES ANDEQUIPMENT LIST GENERAL NOTES :1. (42) REC SOLAR REC290TP2, (290W) WIRED AND LISTED TO UL1703 STANDARDS2. THE SOLAREDGE SE10000H-USRGM INVERTER WITH INTEGRATED DC DISCONNECT AND ARCFAULT PROTECTION. ATTACHED WITH SYSTEM ELECTRICAL SPECIFICATIONS, GROUND FAULTPROTECTION & LISTED TO UL 1741 STANDARDS.3. PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICEAS PER NEC SEC. 250.166(A).4. SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITHREQUIREMENTS OF ART. 690 OF THE NEC.5. CONDUIT ABOVE ROOF SHALL BE NO LESS THAN 1" FROM TOP OF THE ROOF TO BOTTOM OFRACEWAY. TABLE NEC 310.15(B)(3)(C).6. PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED INMETALLIC RACEWAY AND SHALL BE IDENTIFIED EVERY 10 FEET -- AND WITHIN 1 FOOT ABOVEAND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS, OR BARRIERS -- WITHMINIMUM 3/8-INCH-HIGH WHITE LETTERING ON RED BACKGROUND READING: “WARNING:PHOTOVOLTAIC POWER SOURCE7. SYSTEM GROUNDING ELECTRODE CONDUCTOR FOR PV SYSTEM TO BE SIZED TO MEET THEREQUIREMENTS OF NEC TABLE 250.66.8. THE EXISTING MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER.9. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM.10. TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION.11. SOLAREDGE INVERTERS ARE LISTED TO UL 1741 AND UL 1699B STANDARDS12. SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741STANDARDSMATERIAL LISTQTYEQUIPMENTDESCRIPTION42REC SOLAR REC290TP2,(290W)OPEN CIRCUIT VOLTAGE (Voc) : 38.8VMAX. POWER VOLTAGE (Vmp) : 32.1VSHORT CIRCUIT CURRENT (Isc) : 9.71AMAX. POWER CURRENT (Imp) : 9.05APTC RATING : 267.9W01SOLAREDGESE10000H-USRGMDC MAX SYSTEM VOLTAGE : 480VAC OUTPUT VOLTAGE RANGE : 211-240VMAX. AC OUTPUT CURRENT : 42AMAX. AC POWER OUPUT : 10000WWEIGHTED EFFICIENCY : 99%42SOLAREDGE P340OPTIMIZERS1FUSES60A1JUNCTION BOX600VDC, NEMA 3R, UL LISTED1AC DISCONNECT60A FUSED RATED, 240VAC, NEMA 3R UL LISTED60 FTCONDUIT3/4" OR LARGER EMT CONDUITRATED DC INPUT POWER : 340WMAXIMUM INPUT VOLTAGE : 48VDCMPPT RANGE : 8-48VDCMAX. INPUT CURRENT : 13.75ADCMAX. OUTPUT CURRENT : 15ADC
REVDATEDESCRIPTIONVERSIONUR10/21/2021INITIAL RELEASESHEET NAMESHEET NUMBERPV-6 PROJECT NAMENUTTER, SHERRY
7603 NORTH BLVD,
FORT PIERCE, FL 34951 USA
APN# 130160703310009
AHJ: ST. LUCIE COUNTYSHEET SIZEANSI B 11" X 17"FREEDOM FOREVERELECTRICAL CONTRACTOR NO:JOB ID: F110230GREG ALBRIGHT43445 BUSINESS PARK DRIVESUITE110, TEMECULA CA 92590TEL: (888) 557-6431CERTIFIED ELECTRICALCONTRACTOR EC13008056CERTIFIED ROOFINGCONTRACTOR CCC1332814WARNING LABELS &PLACARD CAUTION !POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THEFOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWNAT:MAIN SERVICE PANEL & UTILITY METER,SUB PANEL AC DISCONNECT & INVERTER7603 NORTH BLVDWARNINGPOWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICE!WARNINGELECTRIC SHOCK HAZARDIF GROUND FAULT IS INDICATEDALL NORMALLY GROUNDEDCONDUCTORS MAY BEUNGROUNDED AND ENERGIZEDLABEL LOCATION:AC DISCONNECT & INVERTER(PER CODE: NEC690.54)PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 42 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSLABEL LOCATION:SERVICE PANEL IF SUM OF BREAKERS EXCEEDSPANEL RATING(PER CODE: NEC 705.12 (B)(2)(3)(b)LABEL LOCATION:AC & DC DISCONNECT AND SUB PANEL(PER CODE: NEC 690.13(B))WARNING:PHOTOVOLTAICPOWER SOURCELABEL LOCATION:CONDUIT, COMBINER BOX(PER CODE: NEC 690.31(G)(3)LABEL LOCATION:AC & DC DISCONNECT AND SUB PANEL(PER CODE: NEC 690.41(B))TERMINALS ON THE LINE AND LOADSIDES MAY BE ENERGIZED IN THEOPEN POSITIONWARNINGELECTRIC SHOCK HAZARD!RAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMLABEL LOCATION:RAPID SHUTDOWN(PER CODE: NEC 690.56(C)(3)LABEL LOCATION:MAIN SERVICE PANEL & NET METER(PER CODE: NEC 705.12(D)(3), NEC705.12(B)(3-4) & NEC 690.59)WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENT!LABEL LOCATION:INVERTER(PER CODE: NEC 690.31(I)LABEL LOCATION:MSP(PER CODE: NEC 690.13 (F), NEC705.12(B)(3-4) & NEC 690.59)CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED!MAIN PHOTOVOLTAICSYSTEM DISCONNECTLABEL LOCATION:MAIN SERVICE DISCONNECT / UTILITY METER(PER CODE: NEC 690.13(B))WARNINGELECTRIC SHOCK HAZARDTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULES AREEXPOSED TO SUNLIGHTLABEL LOCATION:DC DISCONNECT, POINT OFINTERCONNECTION(PER CODE: NEC 690.13(B))! WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!PHOTOVOLTAICAC DISCONNECTLABEL LOCATION:AC DISCONNECTNEC 690.13(B)LABEL LOCATION:DC DISCONNECT, INVERTER(PER CODE: NEC690.53)RATED MAXIMUM POWER- .POINT CURRENT (Imp) .RATED MAXIMUM POWER- .POINT VOLTAGE (Vmp) .MAXIMUM SYSTEM .VOLTAGE (VOC) .MAXIMUM CIRCUIT .CURRENT (Isc) .AVVA30.4540048045DC DISCONNECT / RAPID SHUTDOWN SYSTEMIFC 605.11.3.1(2) & 690.56(C)(1)(b)LABEL LOCATIONSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUT DOWNCONDUCTORS OUTSIDETHE ARRAY. CONDUCTORSWITHIN THE ARRAYREMAIN ENERGIZED INSUNLIGHT.SOLAR ELECTRICPV PANELS(N) AC FUSEDDISCONNECT(E) INVERTER(E) 150A MAIN SERVICE PANELWITH (E) 150A MAIN BREAKER(E) UTILITY METER(N) PV MODULESINVERTER #1
REVDATEDESCRIPTIONVERSIONUR10/21/2021INITIAL RELEASESHEET NAMESHEET NUMBERPV-7 PROJECT NAMENUTTER, SHERRY
7603 NORTH BLVD,
FORT PIERCE, FL 34951 USA
APN# 130160703310009
AHJ: ST. LUCIE COUNTYSHEET SIZEANSI B 11" X 17"FREEDOM FOREVERELECTRICAL CONTRACTOR NO:JOB ID: F110230GREG ALBRIGHT43445 BUSINESS PARK DRIVESUITE110, TEMECULA CA 92590TEL: (888) 557-6431CERTIFIED ELECTRICALCONTRACTOR EC13008056CERTIFIED ROOFINGCONTRACTOR CCC1332814OPTIMIZER CHART1-10123411-2021-3031-4041-5051-605678910POWER OPTIMIZER CHARTNORTH BLVD
REVDATEDESCRIPTIONVERSIONUR10/21/2021INITIAL RELEASESHEET NAMESHEET NUMBERPV-8 PROJECT NAMENUTTER, SHERRY
7603 NORTH BLVD,
FORT PIERCE, FL 34951 USA
APN# 130160703310009
AHJ: ST. LUCIE COUNTYSHEET SIZEANSI B 11" X 17"FREEDOM FOREVERELECTRICAL CONTRACTOR NO:JOB ID: F110230GREG ALBRIGHT43445 BUSINESS PARK DRIVESUITE110, TEMECULA CA 92590TEL: (888) 557-6431CERTIFIED ELECTRICALCONTRACTOR EC13008056CERTIFIED ROOFINGCONTRACTOR CCC1332814SAFETY PLANSAFETY PLANMARK UP KEYINSTRUCTIONS:1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET.2.SAFETY PLAN MUST BE MARKED BEFORE JOBSTARTS AS PART OF THE PRE-PLAN3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE& MAKE NOTES ON THE JHA SHEETIN CASE OF EMERGENCYNEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINICNAME: _______________________________________________ADDRESS: ___________________________________________SAFETY COACH CONTACT INFORMATIONNAME: _______________________________________________ADDRESS: ___________________________________________ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THESAFETY PLAN AND SIGN INDICATING THAT THEY AREAWARE OF THE HAZARDS ON-SITE AND THE PLAN FORWORKING SAFELY.__________ __________________________ __________________________ __________________________ __________________________ ________________DATE: ______________ TIME:___________________________PERMANENT ANCHORTEMPORARY ANCHORINSTALLER LADDERJUNCTION / COMBINER BOXSTUB-OUTSKYLIGHTNO LADDER ACCESS (STEEP GRADEOR GROUND LEVEL OBSTRUCTIONS)RESTRICTED ACCESSCONDUITGAS SHUT OFFWATER SHUT OFFSERVICE DROPPOWER LINESPTILBS7ZGASH2O
REVDATEDESCRIPTIONVERSIONUR10/21/2021INITIAL RELEASESHEET NAMESHEET NUMBERPV-9 PROJECT NAMENUTTER, SHERRY
7603 NORTH BLVD,
FORT PIERCE, FL 34951 USA
APN# 130160703310009
AHJ: ST. LUCIE COUNTYSHEET SIZEANSI B 11" X 17"FREEDOM FOREVERELECTRICAL CONTRACTOR NO:JOB ID: F110230GREG ALBRIGHT43445 BUSINESS PARK DRIVESUITE110, TEMECULA CA 92590TEL: (888) 557-6431CERTIFIED ELECTRICALCONTRACTOR EC13008056CERTIFIED ROOFINGCONTRACTOR CCC1332814JOB HAZARD ANALYSISJOB HAZARD ANALYSISCrew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site CaptureLadder Access·Ladders must be inspected before each use.·Extension ladders must be set up on a firm and level surface ata 4-to-1 rise to run angle (or 75 degrees) and the top must besecured to the structure. Extension style ladders placed onuneven, loose or slippery surfaces must additionally have thebase firmly anchored or lashed so the base will not slip out.·Extension ladders must be used with walk-through devices orthe ladder must extend 36" above the stepping off point.·A-frame ladders must only be climbed with the ladder spreaderbars locked in the open position; A-frame ladders shall not beclimbed while in the closed position (ex, closed and used whileleaned against a structure).Additional notes:Mobile Equipment·Only Qualified operators will operate equipment; operators mustmaintain a certification on their person for the equipment beingoperated.·Type(s) of mobile equipment (Type/Make/Model):·Qualified operator(s):Material Handling and Storage·Materials will be staged/stored in a way that does not present ahazard to client, personnel or public. Materials stored on theroof will be physically protect from failing or sliding off.Fall Protection·A site-specific plan for fall prevention and protection is requiredprior to starting work and must remain onsite at all times untilwork is complete; a fall rescue plan must be outlined anddiscussed among the crew prior to work start.First-person-Up (FPU) must install their anchor and connectbefore any other task, including installing other anchors. TheLast-Person-Down (LPD) must be the only person on a roofuninstalling fall protection.·FPCP (name and title):FPU and LPD (name and title):Electrical Safety·The Electrical Qualified Person (EQP) is required onsite toperform electrical work.·All electrical work will be performed with equipment in anelectrically safe condition (de-energized) unless approval hasbeen granted prior to work.·Service drops and overhead electrical hazards will beindentified and protected from contact, as neccessary.·EQP (name and tile):Public Protection·The safety of the Client and the Public must be maintained at alltimes.·The Client and the Public shall be prevented from entering thework zone through the use of barriers and/or signage, asrequired.·Company, Client and Public property shall be protect fromfalling objects.·Pets (including dogs) shall be secured by their owners prior towork start.·The client should not leave pets, family members, or others inthe charge or care of Employees, Contractors, or TemporaryWorkers.·Crew leader responsible for communication with the client:·Client and public is excluded from work area by barricades (N/A,Yes, No):Training and Pre-Job Safety Briefing·All employees onsite shall be made aware of the specifichazards of this project and review this HJA during a pre-jobbriefing, and their signature indicates awareness of siteconditions and the plan to eliminate any hazards identified priorto and during the project.·Crew leader (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):Crew member (name/title):Airborne Contaminants:Asbestos-containing (Transite) piping (ACP) - Do not disturb(move, drill, cut fracture, etc.)Asbestos-containing thermal insulation (ACI) andAsbestos-containing duct wrapping (ACW) - do not disturb, noattic or crawlspace access is allowed if work to be performedcould cause exposure to personnel, client or public.If yes, list specific tasks and protection in place:Weather and Environment·The site supervisor shall forecast the weather conditions at thejob site, prior to crew arrival, in order to mitigate any hazardsassociated with inclement weather (heat, cold, wind, rain, etc.)·The site supervisor will utilized a portable wind meter(anemometer) to verify actual onsite wind conditions, bychecking at the ground and on any elevated work surface (ex,rooftop) prior to work start, at midday and prior to solar panelstaging on a roof.·Elevated work involving the moving or maneuvering of solarpanels shall cease at 25mph (sustained wind) until windsubsides.Forecasted weather maximum temp (degrees F):Heat Related Illness PreventionEmployees shall have access to potable drinking water that isfresh, pure, and suitably cool. The water shall be located asclose as practicable to the areas where employees are working.Water shall be supplied in sufficient quantity at the beginning ofthe work shift to provide at least one quart per employee perhour for drinking for the entire shift. Employees may begin theshift with smaller quantities of water if they identify the locationand have effective means for replenishment during the shift toallow employees to drink on quart or more per hour. Thefrequent drinking of water shall be encouraged.Shade shall be present when temperature exceeds 80 degreesFahrenheit. When the outdoor temperature in the work exceeds80 degrees Fahrenheit, employees shall have and maintain oneor more areas with shade at all times.·New employees must be acclimatized. New employees will bemonitored by their Crew Leader (site supervisor) for the first two(2) weeks of employment or longer when necessary.·Employees will be allowed and encouraged to implementscheduled breaks during each shift. Employees must takecool-down breaks in the shade any time they feel the need to doso to protect them from overheating. Supervisors areREQUIRED to allow employees any break period they needduring high heat conditions.·Cool Vests are encouraged for all employees at all times duringperiods of high heat.·Identify the location of the closet Occupational/Industrial Clinicor Hospital in case a crew member becomes ill.What is the specific plan to provide and replenish sufficient water forall employees on site?·If offsite replenish is necessary, where will you go to replenishwater (location/address):·Who will replenish the drinking water (name):Restroom facilitiesEmployees shall have access to restroom facilities withhand-washing stations. Use of onsite restroom is at the client'sdiscretion (location is annotated below). If client does not givepermission, location of suitable restroom facilities withhand-washing stations offsite will be provided. The onsitesupervisor will identify location and make arrangements toensure all employees have access at any point.·Restroom facilities will be (circle one): Onsite - Offsite·If Offsite, add location name and address:Incident Reporting Procedure·Contact your Site SupervisorName:Phone:·Contact your ManagerName:Phone:·Contact your Site SupervisorName:Phone:With: Your full name, phone number, office location, brief descriptionof what happen and when.NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE(add as many as necessary by using additional sheets)Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident: