HomeMy WebLinkAboutAPPROVED Plans - 4 La Paloma(1)FLOOR FL 4N
35'-0"
TYPICAL NOTES: SCALE 1/4" = 1'-0"
I. Contractor to verify ALL notes and dimensions prior to
proceeding with work.
2. Contractor to STRICTLY enforce ALL OSHA Requirements.
3. ALL Lumber to be used as Beam, Rafters, etc... to have
a minimum 1,400 P.S.I. fiber stress.
4. No dissimilar metals to touch.
5. ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
ALL Concrete used for vertical filled cells, cont. tie beams etc.. to
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
L Drywall at ceilings shall be leveled and attached to bottom chord
of trusses with screws per FBC R702.3.5.
1. ALL wood in contact with concrete shall be pressure treated.
8. ALL wall dimensions are nominal and not finished wall or stud dimensions.
9. ALL plumbing fixtures to be low flow.
10. Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11. Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements.
12. Lowest finished floor to be set by Governing Building Department
surveyor to set in field.
13. Separation between residence and garage shall be per FBC R302.6
14. Door between garage and residence shall be 1-3/4"t 20 min. rated door
15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC R302.9.1
1�. wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC R302.9.2
17. All exposed attic insulation materials installed on attic floors shall have a critical radiant
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
materials exposed on the underside of the roof deck or on the attic walls shall comply
with F.B.C. R31� - see permit info box of code edition
18. Gypsum board material shall conform to ASTM C3�, C�`l, C4-15, C514, C�30, C`l31
Ccr60, C1002, C1047,C1177, C1178, C1278, C1395, or C139and shall be installed
according to the following: (FBC R702.3.5)
Dr wall
y
Thickness
Location
Orientation
Framing
Spacinr
Max. spacing
P 9
of fasteners
Nail sizing options for
installation of drywall into
Nails
Screws
Maximum
wood framing members
2"
x min. thickness
Ceiling
Perpendicular
24"
7"
12"
13ga 1 3/8" long with 19/64" head
OR
0.098" diameter x 1 1/4" long
/2
annular -ringed or 5d cooler nail
OR
Walls
Either
I6"
8°
16"
0.080" dia. xx 1 5/8" long with
Direction
IS/IIIhead
OR
Gypsum board nail 0.086" dia.
x 15/8" with 9/32" head.
Ceiling
Perpendicular
24"
7"
12"
13ga 1 5/8" bong with 19/64" head
OR
0.098" diameter x 1 3/8" long
e
annular -ringed or 6d cooler nail
OR
Walls
Either
16"
8"
16"
0.092" dia. xx 1 7/8" long with
Direction
I/4 head
OR
Gypsum board nail 0.0915" dia.
x 17/8" with 19/64" head.
19, ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.�,
A108.1, A118.1, A118.3, A13>o.l and A131.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C1178 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall the in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanyingg smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Window
Schedule
Mark
Size
Rough Open.
Window Description
PRESSURE ZONE
I.
4'-5 �8" x 4'-2 �8"
54 �8" x 50 7/8',Single
Hung
ZONE 4
2.
6'-tis" x 5'-3 %e"
15" x III%4"
Single Hung
ZONE 4
3.
2'-2i2" x 3'-2 fie"
21 �2"x 38
Single Hung
ZONE 4
4.
3'-1 %'x 4'-2 �e"
38 %"x 50%"
Single Hung
ZONE 4
ALL
Windows to be aluminum
windows w/ tint
and mullions per
elevations.
ALL
windows to withstand
pressures in permit info box on
sheet
ALL
windows in bathrooms to
be tempered
All
rough opening
dimensions
to be verified bg contractor
with
manufacturers specs prior to construction
D oor Schedule
Mark
Size
Rough Opening
Door Description
PRESSURE ZONE
A
10'-0" X 1'-0"
120" x 84"
Overhead Garage Door
ZONE 5
B
3'-0" X 6'-8"
41 %4"x 83%4"
Fiberglass Panel - Inswing
ZONE 4
C
III X 111
tom
14 x 81 of` Byes
Sliding Glass Door
ZONE 4
D
2'-8" X C-8"
Solid Core - Wood - 6-Panel -Bi-Fold Finished 32" x 81 �2"
E
2'-8" X III
Solid Core - Wood - 6-Panel
F
2'-8" x 6'-8" x I �4"
Solid Core - Wood - 6-Panel - Pocket
G
2'-8" x 6'-8" x I %4"
Solid Core Wood, Steel, or Masonite Door (20 min rated)
H
5'-O" X 6'-8,,
Solid Core - Wood - Pocket
J
2'-V X III
Solid Core - Wood - 6-Panel - BI-FOLD
K
2'-8" X C-8"
Solid Core - Wood - 6-Panel
L
2'-0" X C-8"
Solid Core Wood, Steel, or Masonite Door (20 min rated)
M
2'-0" X IiI
Solid Core - Wood - 6-Panel - BI-FOLD
N
2'-6" X III
Solid Core - Wood - 6-Panel
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 1*1
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET 41
All rough opening dimensions to be verified bg contractor
with manufacturer s specs prior to construction
ALL wiNDows
TO HAVE
DRYWALL SILLS
AREA CALCULATIONS
Living A/C =
1,306
sq.
ft.
Front Porch =
23
sq.
ft.
Rear Porch =
118
sq.
ft.
Garage =
303
sq.
ft.
Total Under Roof=
1150
sq.
ft.
Total Cubic Ft =
2• VTR
JI
I
I 2"
I
LAV-1
MASTER
BATH
2"
211
WC-1
3"
3
2' VTR
BT-1 2"
J�
3" 12"
wM-1
2"
3°
LAUNDRY
3" �
PLUMBING RiSER
2" JI 2" AAV
Lr
KTICHEN 2"
To Septic
Install doors thru buck into
block using tapcons as stated
in product appproval form on sheet I.
Exterior face Buck to be 2 x L" PT
:t approval for
i into wall req.
Detail at Door
NTS
INSTALL VULKEM BLOCK SEALANT
ON ALL JAMB, HEADER, AND
SILL BLOCK PRIOR TO BUCK
INSTALLATION
Install windows thru buck into
block using tapcons as stated
Exterior face in product approval form on sheet I.
of wall
Varies
1"x4" P.T. Buck nailed to
lock with case hardened nails
prior to window attachment
Detail at wlndowS
Metal roofing and underlayment intstalled per Product Approval
as shown on sheet I over COX decking - see roof sheeting
attachment diagram on roof plan.
Truss mfg to pprovide level
return to be I" short of wall
Aluminum Drip
Edge t Fascia
2" x 4" Sub -Fascia 12°
Kaycan full o vent vinyl soffit installed
per product approval form on sheet I.
I" x 4" nailer attached t0,J
level return with (2) 8d
ring shank nails with min. 1.5"
penetration into soffit framing
5/8" thick light textured
stucco on typical concrete \
block construction
45 bar vert. w/
30" overlap -
at each filled cell
12
4 F
Wood
Base
mL4riii
ur
NTS
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer)
\R-30 blown fiberglass
in bottom chord of trusses
I/2" drywall with smooth finish
Two rows of beam block filled with concrete
and (1) 45 bar cont. in each row. Substitute
precast lintel filled with concrete and (1) 45
bar cont. for bottom row over openings
1/2" dr wall over I" x furring
strips at IIIo.c. with R4.1 i-foil
insulation on typical 8" Block walls
All drywall to be installed per FBC R702.3.1
T and shall meet all pertaining ASTM codes.
00 Mortar to be Type "M" only proportioned per FBC R607.1
and Mortar Joints shall comply with FBC R607.2.1.
Provide Our-O-Rock at all wet areas (ex. showers, tubs etc...)
Fill cell with grout and
(I) 45 bar vert. (typical).
Max. spacing shall not exceed
481, unless otherwise noted Masonry Beam
see foundation plan notes for
spacing at openings
I" x 6" P.T. Buck nailed to
4" concrete slab with fibermesh OR block with case hardened nails
111 410/10 WWM on 6 mil Visqueen over prior to door attachment head
clean compacted termite treated fill
and iambs
Install SGD Frame thru buck into
block using tapcons as stated
in product approval form on sheet I.
17
11
IIII-
1
14"w x 18 Concrete footing
with (2) 45 bars cont. and its
transverse bars at 48" o.c.
TYPICAL SECTION
Scale : 1/2" = 1'-0"
verify sill attachment req.
with product approval on -
sheet I.
Bottom
r
Sill
0
O
0
OPTi NAL
PATI /SLAB 12
UN-
0
0
J
12'-8" 10'-10" 0
S
0
COVERED
o
DEN PORCH
N
MASTER o
-
BEDROOM
o
�Um
'r a u
� �_0 U
�a
o
o0 0 000
N
E I o
I
I
o
I
I E
6'
4" 8' 2" `�„ 18'410"
°
0 GREAT I ROOM
010
1 19
CLOSET
I
o
i
O r O I N
�
3
N
ST R7T I ClO
1
vinyl
M2„
H I
„
o
u,
5, 0„
I
O
Pll.lD_ 0 I
10.
�ZR V DINING
I ROOM
Tankless WH I
O
<r
mounted above 122 3/8"
O
co
48" a.f.f. O °i
34 3/4"h
H.B
m
O
Dead wood 40"h nee wall 4" wide
and 58"h for WH - - - - - -
o3
rn
Meter
0
150 Amp
Pane
_ --� ___--__- ---_
r22" x 3G' r----
Accessl 171, vinyl I 18 T
� uVu
a
`r a )
U
1Attic
CK
ath light Was ER trash
I
D W i On
DAND ullou
RYER
O
GARAGE
4� I ZI 15-4
-
°
0
w1 W
O a
N
LAUNDRY
�_O
1 a)OI
z
a
B
O
r-------------------
i
KITCHEN o
°
I
I
N
r-
I
I
I
00
o0
0
`
O
H.B.
I
I
S
18" pantry
I
I
©
cabinet
ENTRY
O
j
5/8" dryeall I
A/C
o
>L
I
STORAGE
1
- W
I
I
Ln
`r W
O
I
I
O
O
O
O
00
00
O 00
00 O
O 00
ding door
,Typical Flooring
2'-8" 10'-O„ 6,_4 3/e„ 2'-4 %' 2'-4 %' S,a/b„ 5,_7 3/e„
T
4'-9 Y'4„ 11`2 3/e„
I" x 4" P.T. Buck nailed to
block with case hardened nails
prior to door attachment
Masonry Wall
Install SGD Frame thru buck into
block using tapcons as stated
in product approval form on sheet I.
Jamb
Sliding Door Detail
At Masonry Wall NTS
LA PALOMA
Digitally signed by
Daniel R. Braden
Date: 2021.09.21
11:13:55-04'00'
L
Q
m
U
V
tfl
[L
to
IllyLU
N
O O
W
� r
� " O
LLI
<
-1
NN U
< co 06 u
<
t<
<
#
I
Z NNo
~
O113
_
U_ Q; l _
fo
�
4J
SHEET NO:
2.
OF S.
JOB NUMBER:
21-2-41 B
J. �X
°o c
c
o° o°
O° °o AR 977770
° o�
°� °
�oO��D pQn 1l
I NN
0 IN - I I=
SCALE: 1/4„ = I'-C"
STRUCTURAL
MOTES:
I.
ANY CHANGES TO THE PLANS MUST BE SUBMITTED TO THE
ii.
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
ARCHITECT FOR APPROVAL BEFORE PROCEEDING WITH
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
CONSTRUCTION
2.
CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION
12.
CONTRACTOR TO PROVIDE SOLID FILLED CELL AND 45 BAR VERT. AT
OF ALL NOTATION AND DIMENSIONS PRIOR TO START OF
-48" O.C. MAX. PROVIDE (1) FILLED CELL ON EACH SIDE OF OPENINGS
CONSTRUCTION
UP TO 5'-11" WIDE. PROVIDE (2) FILLED CELLS ON EACH SIDE OF OPENINGS
6'—O" WIDE AND UP. VERIFY ALL FILLED CELL LOCATIONS WITH FOUNDATION
3.
ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
PLAN.
BEARING CAPACITY. IF ANY SUB —SOIL, MUCK OR NON —UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
13.
DESIGN LOADS ARE AS FOLLOWS:
PROPER ENGINEERING DATA FOR DESIGN.
SEE PERMIT INFO BOX ON SHEET I.
`�••
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
1-4.
ALL REINFORCING STEEL SHALL BE GRADE 6O, MEETING ASTM A-16, t
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 PSI OR -f,000 PSI GROUT MIX AT 28 DAYS
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A — 30-1 STEEL.
5•
POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 2-f HOURS. NO
15.
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
6.
SLAB ON GRADE TO BE A MINIMUM -4" THICK W/ 6X6 10/10
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
16.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
FOOTING: 3"
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
BEAMS: 1-1/2"
1.
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
1-1.
LAP ALL REINFORCING STEEL A MINIMUM OF -48 BAR DIAMETERS.
BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF
CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL
18.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI
PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE
STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND
19.
ALL STANDARD STRUCTURAL LUMBER SHALL BE SYP WITH A MINIMUM
COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY
SOUTHERN YELLOW PINE 42. MIN. Fb AS FOLLOWS:
PROCTOR VALUE.
2" x 4" = Fb 1,500 PSI 2" x 10" = Fb 1,000 PSI
8.
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
2" x 6"/8" = Fb 1,200 PSI 2" x 12" = Fb 9-15 PSI
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
20.
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
ATTENTION OF THE ARCHITECT.
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
q.
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
21.
CONTRACTOR TO PROVIDE FORM BOARD SURVEY AND FURNISH
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
TO TRUSS MFG PRIOR TO TRUSS CONSTRUCTION FOR ACCURACY TO FIELD
10. CONTACTOR TO VERIFY ALL RECESS THICKNESSES AT SHOWERS
FLOOR FINISH CHANGES, SPECIALTY EQ. ETC...
45 bar vert. w/
30" overlap Fill cell with concrete and
at each filled c (1) 45 bar vert. (typical).
Max. spacing shall not exceed
Wood 48" unless otherwise noted
Base see foundation plan notes for
spacing at openings
4" concrete slab with flbermesh OR
6"x6" 410/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill C
Grade T - -�
-i 8 "d Concrete with (2)45 bars footing cont. and45
IIII � I
3„ transverse bars at 48" o.c.
3"
Ile
14" 31
% TYPICAL FOOTING DETAIL
J SCALE 1/2" = 1'-0"
4" concrete slab with fibermesh OR
6 x6 1$10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
45 bar cont.
Step per
foundation plan
#5 bars cont. bottom steel
DETAIL AT GARAGE STEPDOWN
SCALE 1/2" = 1'-0"
12" x 12" concrete column
block filled with concrete
and (2) #1 bars vert. tied
into lintels above
30"x30"xl6" concrete
column footing with (4)
1*5 bars each wag
SCALE 1/2" = 1'-0"
45 bar cont. in
Termite Protection for New
Construction as per F.B.C. R318.1
CONTRACTOR TO REFERENCE F.B.C-R
FOR FURTHER REQUIREMENTS
Thicken edge to 8"x8"
with concrete and
one #5 bar continuous
4" concrete slab with flbermesh OR
6"x6" 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
PORCH SLAB EDGE DETAIL
SCALE 1/2" = 1'-0"
45 bar vert. w/
30" overlap
I _1� at each filled cell
Curb height Wood
Verify based on Base
foundation plan
Grade :1
Fill cell with grout and
(1) 45 bar vert. (typical).
Max. spacing shall not exceed
48" unless otherwise noted
see foundation plan notes for
spacing at openings
4" concrete slab with flbermesh OR
(."x6" 410/10 WWM on 6 mil Visqueen over
/ clean compacted termite treated fill
.... .......
It ICI
14"w x 18"d Concrete footing
- Ex
with (2) 45 bars cont. and 45
transverse bars at 48" o.c.
Ile 411
90
2f=5LGARAGE CURB DETAIL
1) SCALE 1/2" = 1'-0"
CL r; A
E
0
0-)
Contractor to provide
proper foundation chairs
for proper steel installation
30 min.
2" x 6" PT wood secured with \ Corner Steel L a p
1/2"dia. x 6" expansion anchors
with 2" sq. washer at 18" o.c. overhead door track secured to wood n t S
jamb per manufacturer's product approval
Garage Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED N T S
IN PERMIT INFO BOX ON SHEET #1. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
FOOTING
SCHEDULE
Mark
Size
Description
FI
14"W
x 18"D
MONOLITHIC FOOTING
WITH 2 45 BARS CONTINUOUS
F
1211W
X 1211D
MONOLITHIC FOOTING
WITH (2) 45 BARS CONTINUOUS
30"
x a0" x 14-D
COLUMN FOOTING WITH (4) 45 BARS EACH WAY
8
8"W
x 8"D
THICKEN SLAB EDGE
WITH 1 45 BAR CONTINUOUS
F5
14"W
With
x 18"D
Curb at Garage
MONOLITHIC FOOTING
WITH 2 45 BARS CONTINUOUS - CURB 0 0'-0"
Filled Cell Masonrg Column With One
45 From Footing To Beam Each.
Grout fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
NTS
Filled Cell Masonrg Column With One
45 From Footing To Tie Beam
Grout fill To Be 3000 PSI
See Floor Plan For Location
Single Filled Cell Column
NTS
a
M
4 LA PALOMA
Digitally signed by
Daniel R. Braden
Date: 2021.09.21
11:13:46-04'00'
to
r_
0
to
v
L
z
Q
W
z
z
N
Lu
O
Ul
=
v
�zW��uo
<
NN
U
<
co OD u
0
I
<
00
#
i
Z
NN
~
aj
UULU
0
>r >r
--��
tr
_
1L
1L
uo
'
�3
SHEET NO:
2),
OF S.
JOB NUMBER:
21- 2 -41 B
o AR 977770
°
Provide 45 bars with 12" min. lap
into beam and 48 bar dia. into
Vert. filled cell.
Provide Cast -Crete
8U16-IB/IT precast -
lintel set in mortar
Min. 8" Bearing
Fill lintel solid with
grout.
CBS WALL
Concrete
/ Lintel
Column to
US cont. beam steel to run
through lintel and tie to
down rods in jamb cells.
Provide PT Buck
attached per jamb
letails into filled c
4" Pre -cast
Sill
Verify with Plan
rout Filled Cell
Provide 45 bars with 12" min. lap
into footing and 48 bar dia. into
vert. filled cell.
Scale: 1/2" = 1'-0"
12 "x 12"
Column Block
Rebar
Rebar 4s Bar Dia.
Min. Overlap
Lintel /4ttachment
BEAM SCHEDULE
Mark Size and Description
Two rows of beam block filled with concrete and 1 #5 bar
BI continuous in each row. Hook vert. bar over top bar with
#5 90° bend bar with a 10" min. lap at top bar.
Additional Precast Lintel „ „ „ „
45 bars Lintel Bar Clear A B
CLEAR Length Length Span Bars Bars
' ► =.' ► 2'-10" 2'-8" I'-6" 2,u3 none
3'-6" 3'-4" 2'-2" 2,u3 none
8F8—OBAT 8F8—IBAT 8F8—IB/2T
Additional 4"-O 3'-10" 2'-8" 2,1t3 none
45 bars
CLEA B....
4'-6" 4'-4" 3'-2" 2,u3 none
ne Row of
Block Abov5'-2" 4'-O" 2,3 none
none
Precast LinAdditiona6-66-45'-4" 2,U4 none
us bars
T-0" 6'-2" 2,1t5 none
BFIL-IB/IT BFIL-IB/2T �'-10" 7'-O" 2,5 none
NOTES:
I. min, coverage of steel=1.5"
2. min. bearing required i ea. end=8" ALL reinforcing steel is grade 60_
3. standard for reinf. steel=ASTM A6G
TYPICAL LINTEL SECTION
PRECAST CONCRETE )
LINTEL SCHEDULE
Mark
Window
or D
Unit
5ZWidt
Lintel
Size
Specification
Rows of
"H" Block
Above
" "
Bottom
steel
Size
Top
Steel
Size
Max.
Gravity
Load
(PLF)
Max.
Uplift
Load
(PLF)
Max.
Lateral
Load
(PLF)
L22
X-2"
3'-L"
BFIL-IBAT
ONE
1
85
1
a5
L113
3541
2854
L31
2'-(V
3'-I"
4'-O"
BFIL-IBAT
ONE
1
85
1
a5
2431
3019
2128
L45
4'-5"
V-10"
BFIL-IBAT
ONE
I
a5
1
a5
43LO
2093
44L
L50
V-0"
V-0
BFIL-IBAT
ONE
1
a5
1
a5
3480
1880
1204
LLO
V-8"
T-0
Oft-IBAT
ONE
1
a5
1
a5
2441
1634
891
L80
8'-0'
T-4"
BFIL-IBAT
ONE
I
a5
I
a5
1843
1133
139
L40
T-O"
10'-L"
BFIL-IBAT
ONE
1
85
1 1
a5
1 1533
914
519
L9015
T-Ow
10'-6"
BFIL-IBAT
ONE
1
85
1
a5
1539
914
519
LI00
10'-O"
W-4"
BFIL-IBAT
ONE
1
85
1
a5
13LL
198
6,04
LIOOB
10'-O"
W-4"
BFIL-IBAT
ONE
I
a5
1
a5
13LL
198
604
L120
12'-0"
13'-4'
BFIL-IBAT
ONE
I
a5
1
a5
1015
LOL
433
L120B
12'-O"
13'-4'
BFIL-IB/IT
ONE
I
1 a5
1
a5
1015
LOL
433
L140
14'-0"
15'-4"
BFIL-IBAT
ONE
1
a5
1
a5
1250
485
S41
LILO
Ifs' -Ow
IT-4"
8F8-IB/IT
ONE
1
85
1
85
950
1 404
251
LILOB
IL' -Ow
I1'-4"
BFIL-IBAT
ONE
1
85
I
1 a5
950
404
251
- ALL LINTELS SHALL BE MADE BY CAST-CRETE OR LOTTS LINTELS
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING: INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-O" LONG ARE TO BE PRESTRESSED.
HIP R 0 0 F SHEETING
ATTACHMENT DETAIL
I. Minimum Nail Size = 8d angular ring shank (min. 2.5" long)
2. Minimum Screw Size = ##8 x 2.5"
3. Minimum Sheathing Thickness 19/32" CDX PI wood
4. Use nails or screws based on pressure for roof stated
in zpermit info box on these plans for appropraite roof
ones.
Ke
Area
Ede
Field
Fastener
Pressure
Zone I
6"
6"
8d x 2.5" ring shank
45 psf
Zone 2E 2R 2N
6"
8d x 2.5" ring shank
16 psf
Zone 3E/3R
4"
4"
Sd x 2.5" ring shank
84 psf
ANY ZONE
6"
6"8
x 2.5" Screw
263 ps
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blocking to Vert. leg of
truss with IOd x 1.5 nails at 4" o.c.
Install Simpson MGT into wall using
5/8" dia. threaded rod set min. 12"
into wet beam and (22) IOd nails into truss
R-19 batt
3LOCKING DETAIL
DER STRAPPING
TER BEARINGS POINT
1/8" thick light textured stucco installed per
ASTM C 926 over ASTM O type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D T' pe 2 felt paper using 8d nails. Substrate
to be 19/32 COX Plywood nailed at 4" o.c, in field
and edges with IOd ring shank nails into studs.
Metal roofing and underlsyment intstalled per Product Approval
as shown on sheet I over COX decking — see roof sheeting
attachment diagram on roof plan. \
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 1 1/2" nails
( 24" o.c.) supporting Max.
1810lbs, uplift
Truss mfg to provide level
return to be I" short of wall
Aluminum Drip
Edge t Fascia
2" x 4" Sub -Fascia 12"
Kagcan full o vent vinyl soffit installed
per product approval form on sheet I.
I" x 4" nailer attached to
level return with (2) 8d
ring shank nails with min. 1.5"
penetration into soffit framing
12" x 12" concrete column
block filled with concrete
and (2) 41 bars vert. tied -------
into lintels above
thicken edge to 8"x8"
with concrete and
one :95 bar continuous
BEYOND
Top of footer
16" below finished floor
12
4
Aluminum Drip
Edge t Fascia
Flash and Counter
flash
Nail ledger to
gable end truss
with (2) IOd " �ils
at each web \
5/8" thick stucco on 3/8" hi —rib lath
attached to horizontal and vertical wood
framing with nails or staples to provide
no less than 1-3/4" penetration into
horizontal wood framing and 3/4" penetration
into vertical wood framing members
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
45 bar vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Step
per
foundation
plan
Slope
per
foundation
plan °p
I
Wood
Base
Trusses at 24" o.c.
see shop drawings
by others
R-30 Batts
-19 batts
"Frame ceiling transition
as needed using metal studs
field verify exact configuration
and sizes
Drywall ceiling
see typical section
Celling transition Insulation D(-etaII
nts
Brace Gable end
with 2" x 4" SYP 42
8ft back nailed to bottom
of top chords using (2) IOd
nails at each truss
PRE-ENGINEER-ED WOOD TRUSSES
>s 24"o.c. TYPICAL
( shop drawings bg manufacturer )
\R-30 blown fiberglass
in bottom chord of trusses
I/2" drywall with smooth finish
Two rows of beam block filled with concrete
and (1) U5 bar cont. in each row. Substitute
precast lintel filled with concrete and (1) 45
bar cont. for bottom row over openings
1/2" drywall„ over I" x furring
strips at 16 o.c. with R4.1 i-foil
insulation on typical 8" Block walls
All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
OD Mortar to be Type "M" onl proportioned er FBC R601.1
and Mortar joints shall coinp54 with FBC R401.2.1.
Provide Dur-O-Rock at all wet areas (ex, showers, tubs etc...)
Fill cell with Grout and
() bar Vert. ( ROOF
Max. not ex spacing shall not exceed
8" I d
Mete
Strap Girder truss to wall using Simpson
MGT strapp with (1) 5/8" dia. ATR
embeded 12" min. in concrete and
"0 AMN
Panel 122" x 30 12
I taih light SLOPE ,4
PLAN
HETA 20
HETA 20
4 un ess otherwise note
see foundation plan notes for spacing at openings — OVERHANGS AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET
4" concrete slab with fibermesh OR — ROOF PITCH AT -f:12 UNLESS OTHERWISE NOTED ON THIS SHEET
6"x6" 410/10 WWM on 6 mil Visqueen over — TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER
clean compacted termite treated fill — ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE
ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION.
A 1 h1� 1111—
'
1111
- III FI III- 14
T 4plcal Section at Front Porch
Scale : 1/2" = I'-O"
0
W
z
— ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER `f LA PALOMA
ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR
TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION Digitally signed by
— CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO Daniel R. Braden
PROVIDE FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO Date:2021.09.21
TRUSS CONSTRUCTION 11:13:37-04100,
to
O
E
v
L
z
�
a
�
�
0
m
u
Z
Z
UJ
N
o O
W
'zW���o
<
� v
>
<
Op 03 u 0
t �
<
#
I
Z NN
�
aj
~
U
O rLU r� a-
U
_
1L Q; 1L
mN
fo
�
=
4J
cn
SHEET NO:
4 .
OF S.
JOB NUMBER:
21-2-4 IS,
r,°° ° o0c
°o
0V_ R. OR4D4
® .0
AR 977770 °0
00Q�0 G°anf]
PANEL
"A"
Poles
BR
Load
Wire
Description
circa
circa
Description
Wire
Load
BR
Poles
1
20
1.2 kw
912
Refrigerator
I
Range
U.
12.0 kw
50
2
1
20
1.2 kw
u12
Clothes Washer
3
1
20
1.5 kw
912
Kitchen S.A.C.
5
6
Dr er
u10
5.0 kw
30
2
1
20
1.5 kw
u12
Kitchen S.A.C.
I
8
1
20
912
Bathroom Recepts
9
10
Air Cond sor
#10
5.0 kw
30
2
1
20
1.2 kw
u12
Dishwasher
11
12
1
20
1.2 kw
u12
Microwave
13
14
Air Handl r
u10
5.0 kw
30
2
1
15
u14
General Lighting
15
16
I
15
u14
General Lighting
IT
IS
WH
#10
5.0 kw
25
2
1
15
914
General Lighting
19
20
I
15
914
General Lighting
21
22
Goo
u12
0.81 KW
20
I
I
15
u14
General Lighting
23
24
Spare
Spare
25
26
Spare
Spare
21
28
Spare
Spare
29
30
Spare
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qt .
Watts
Total(Watts)
General Lighting (3 watts sq. ft.)
Small Appliance Circuit(s)
Range
Refrigerator
Microwave
Dish Washer
Clothes Washer
Clothes Dryer
Water Heater
Garage Door Opener
1400
3
4.200
2
1,500
3.000
1
12,000
12,000
1
1,200
1,200
1
1,500
1,500
1
1,200
1,200
1
1,200
1,200
1
5,000
5,000
1
15,200
15,200
1
810
810
Total Watts
45.310
First 10000 Watts e100%
1
10.000
10,000
Remainder 35.310 940%
1
O
14.124
Electric Heat or A/C 10,000 065%
1
10,000
10,000
Calculated Load
Watts
34.124
Voltage
240
Calculated Wattage Divided bg Voltage = Total Amps 142.18
Panel Size Required = 150 Amps
Electrical Symbol Legend
S
Single Pole Switch
®
Recessed Can Light
53
Double Pole Switch
®
Egeball Recessed
P
Push Button Switch
Exhaust Fan
Duplex Outlet
Ceiling Mounted Light
_0
Special Receptacle
Wall Mounted Light
*9
Waterproof ground fault circuit
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
0
Carbon Monoxide Detector
"&
Flood Light
Q
Thermostat
m
Electrical Panel
®
Central Vac
8
Electrical Meter
®
Smoke Detector
Ceiling Pan
®
Television Jack
Telephone Jack
AC c
A/C Disconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
®
Speaker Hook -Up
FB = JUNCTION BOX TO SUPPORT A FAN
O = THERMOSTAT LOCATION
B/A = BALANCED AIR
FIELD VERIFY SERVICE LOCATION RESPECIVE TO PANEL LOCATION AND USE APPROPRIATE RISER BELOW
2.5ton 5k
A/C disc.
A/C disc.
42/0 AL SER Cable
(3) #1 THHN Copper
With UI Grnd
2" PVC Schedule
40 conduit
2" PVC Schedule
IMP
40 conduit sleeve
ISO
So-
MCB
into attic
AMP
MCB
PANEL AHU
PANEL AHU
200a rated
200a rated
meter can O
meter can O
METER
METER
Intersystem bonding
Intersystem bonding
2" PVC ( F P L ��
Termination point
2" PVC ( FPL
Termination point
schedule 80
schedule 80
2" rigid service FPL
2" rigid service FPL
GEC
Bare ub co per wire
to (2) 8'-0 Galvanzied
GEC
Bare u6 co per wire
to l2> 8'-C� Galvanzied
ground rods
ground rods
ELECTRICAL RISER
ALTERNATE SERVICE ELECT. RISER
- Contractor shall use AL-CU
Landing lugs. NTS
- Contractor shall use AL-CU
Landing lugs. NTS
- Contractor shall torque lugs I.A.W.
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
manufacturers recommendations which
shall be verified prior to
construction
shall be verified prior to
construction
- Verify AIC/KIC Rating
prior to ordering equipment
- Verify AIC/KIC Rating
prior to ordering equipment
ELECTRIC NOTES:
I. Use copper wire only from panel to devices
2. Provide and wire all required smoke & Carbon
Monoxide detectors.
3. Contractor to verify location of electrical
service and provider.
4. ALL bath and kitchen receptacles to be GFCI protected.
S. ALL exterior outlets to be WP/GFCI protected.
6. Recessed cans to be installed per NFPA requirements.
1. Tamper resistant AFCI receptacles are required in
ALL rooms.
8. A/C Return Air Balance Must comply w/ FBC RM1602
9. A/C Refricierant lines that are run thru slabs must be
sleeved in -'PVC
10. ALL A/C Equipment shall comply with energy calculation
11. All work shall be performed bg a licensed electrical
contractor, the completed system shall be fully operative.
12. Contractor shall pay for all fees, permits, testing, and
inspections including blower testing where required.
13. All work shall be coordinated with other trades to avoid
interference with the progress of construction.
14. All required insurance shall be provided for protection
against the public liability and property damage for the
duration of the work.
AiC
Meter
H.B.
15. Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two years from
the date of acceptance or certificate of occupancy, or one
year from closing sale of house.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
other phase of Installation that may have been damaged.
16. It is not the intent of these plans to show every minor detail
of construction. The contractor shall furnish and install
all items for a complete electrical system and provide all
the requirements necessary for the equipment to be placed in
proper working order.
1-1. All work shall be done in accordance with the N.E.C. and
shall comply with all local codes and ordinances, and shall
meet all standard requirements of the local electric utility
and telephone company.
18. The electrical system shall be completely and effectively
grounded as required bg the latest edition of the N.E.C.
19. All material shall be new and shall bear underwriters'
labels where applicable.
OPTIONAL
PATIO/SLAB
124 CFM
IOxIOx1
B/A
COVERED
DEN PORCH
MAST
r -1BEDR
M
T
I
I
I
144 CFM
I
I
12x&x1
124 CFM
I
I
IOxlOx1
I I
I
13
CFM
I I
I
8x4x4
I
I'f A 4
I
r-a
ria
I
5 CFM
J
12x12x10 8x4x4
I
B/A
112 CFM 112 CFM
°
IOxlOxl8 I IOxlOxl8
C L 0 T
oo°n
GREAT ROOM
19 CFM
8x4x4
I
0
BATHR
s R
2 CFM
I
EN LO R
II��II
P W D
8x4x4
I
I2"
cuing
I DI INCx
I R OM
20x20
Tankless WH
1 �'
mounted above
48" a.f.f.
01 V-- i
150
Amp
--� I
-----------
anel
22" x ',I
y�►ttic AcceWp
II with light I
STACK
WASHER
is"
D W D O trash
AND
UIIOU
DRYER
r
GARAGE
I �I Q�
3 CFM
L - �� -
- 1l1 CFM
8x4x4
12xbxl
ro
L,�UN
Y
r------------------- i
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
DUCT
38 CFM
8x4x4 I ENTRY
STRIFeLAGF-
L AYOUT
20. All equipment and panel sizes shall be verified before
ordering. The contractor shall provide circuit routings to
suit the job conditions.
21. Furnish and install all fixtures as called for on the plans
or as selected bg others.
22. All raceways and pipes placed in or through any concrete
slab shall be spaced a minimum of three diameters of the
largest conduit or pipe from any other service.
23. All exposed wire below 9'-1" shall be installed in metal EMT
conduit.
24. Dryer Vents to be installed per
FBC RM1502
KITCHEN
SCALE: 1/4" = I'-0"
Install
under c
not she
clarity
Exhaust Duct
Thru Soffit
H.B.
Attic Ventin Calculations FSC 2309.1
Total Attic Space = 1,924 sq. ft.
Venting Ratio I/ISO = 12.82 sq, ft. required
Provide A Continuous Vented Soffit
-I.B.
e For
int Post
it
4 LA PALOMA
Digitally signed
by Daniel R.
Braden
Date: 2021.09.21
11:13:27-04'00'
d)
O
d)
93
Oc•��U
I
�
'
4-3
Cr
`
U
Z
Q
W
Z
Z
D
W
Q
Q
N
(Y
UlJ
o
O
W
=5
"
O
�
z
UJ
LO OD
>
C4N
U
-
00 W u
0
F
�t
<
#
I
Z
C4 "
aj
UULU
--��
a-
tr
_
1L Q;
1L
(�
uo
cn
SHEET NO:
E-1
OF S.
JOB NUMBER:
21-2-41B
0 0��
°o
��L R. 8% %
4���
o° .0
AR 9770
CZn,-