Loading...
HomeMy WebLinkAboutAPPROVED ENERGY CALCS & MANUAL J - 10 LAS CASITASFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING CCPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) I. New construction or existing New (From Plans) 10. Wall Type�1442.0 sgft.) Insulation Area 2_ Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 c. NIA R= ft2 4. Number of Bedrooms 2 d. NIA R= 5. Is this a worst case? Yes 11. Ceiling Types (1476.0 sgft.) ft2 Insulation Area 6. Conditioned floor area above grade (ft2) 1446 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 1446.00 ft2 R=19.0 Conditioned floor area below grade (ft2) 0 c. NIA 30.00 ft2 R= ft2 7. Windows(141.3 sgft.) Description Area 12. Ducts R ft2 a. U-Factor: Sgl, U=1.04 101.25 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 175 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 13. Cooling systems kStu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 3.882 ft. 14. Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 4.284 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area C. U-Factor(AVG) NIA ft2 SHGC(AVG): NIA 15. Hot water systems 9. Floor Types (1445.5 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge insulation R=0.0 1445.50 ft2 b. Conservation features EF: 0.970 b. NIA R= ft2 None c. NIA R= ft2 16. Credits None Glass/Floor Area: 0.098 Total Proposed Modified Loads: 44.57 PASS Total Baseline Loads: 45.19 I hereby certify that the plans and specifications covered by Review of the plans and'HE� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance ,, _ ,. ��� Ys• Q2V with the Florida Energy Code. tir:,. 4*;•°,"p PREPAR D Y 0 Before construction is completed m DATE: -1 this building will be inspected for 4 Ali compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. ,yS with the Florida Energy Code. OWNER/ BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope Ieakage no greater than 7.00 ACH50 (11402.4.1.2). 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY [_I4FrK1 ICT RFPART PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated i BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ___ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN t ft 0 192 ft' __ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' _- 0 1 0 _ 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' ___ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' 0 1 0 1/12/2021 12:02 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 0 _-_ 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 0 1 0 ROOF V Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 f12 Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M.BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood 10 Knee Wall (Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block- Int InsuBEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 2 SW=>NE Exterior Concrete Block - Int InsuBEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 3 NW=>SE Exterior Concrete Block - Int InsuBEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 _ 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5 NE=>SW Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 6 NE=>SW Exterior Concrete Block - Int InsaEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 7 SE=>NW Exterior Concrete Block - Int InsBIEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 8 S=>N Exterior Concrete Block - Int InsBEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 9 SW=>NE Exterior Concrete Block - Int InsBIEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block - Int Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 11 SW=>NE Exterior Concrete Block - Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 12 SW=>NE Exterior Concrete Block- Int InsULAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 13 NE=>SW Exterior Concrete Block- Int InstBREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block - Int InstBREAT/DINT 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY rHFrK1 IST aFPnRT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below Ah�0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.4 0 DOORS # Omt Door Type Space Stones U-Value Ft Width Height In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6ft- WINDOWS Orientation shown is the entered orientation => than ed to Worst Case. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Yes 1.04 0.29 Y 32.9 ft' 1 It 0 in Low-E Single Yes 1.04 0.29 Y 6.9 ft' 1 It 0 in Low-E Single Yes 1.04 0.29 Y 24.0 fN 6 It 0 in Low-E Single Yes 1.04 0.29 Y 37.5 ft' 1 ft 0 in Low-E Single Yes 1.11 0.27 Y 40.0 ft' 8 it 0 in 1 ft 5 in Drapes/blinds 1 ft 5 in None 1 it 5 in None 1 It 5 in None 1 ft 5 in Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 fP 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM So ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.04 139.01 .1263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kStu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitt Split Singi SEER: 15 34.8 kBtu/hr cfrn 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None 1/12/2021 12:02 PM EnergyGauge(D USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 IMP[ IT RI IMMARV cucrlrt ICY 000noY SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / ---- Supply — V — Return-- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handier TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling an Feb Venting Jan Feb [jJCj�Mar Mar A r € Ma ay May Jun (jXjj Jul Jun Augj[XjI Se [ ] Oct r) Nov [) Dec Dec [ ]X Apr [ ] Jul Aug [ ] Sep [[x]I Oct [[XX11 Nov [[XI] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft- Oft 0.3 BEDROOM Default(8 lbs/sq.ft. fi' ft 0.3 WIC Default(8 Ibs/sq.ft. ft. ft 0.3 M. BATH Default(81bs/sq.ft. ft' ft 0.3 KITCHEN Default(81bs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft- ft 0.3 BEDROOM2 Default(8 lbs/sq.ft. W ft 0.3 ENTRY Default(8 lbs/sq.ft. ft. ft 0.3 LAUNDRY Default 81bs/s .ft. ft' ft 0.3 GREAT/DINING 1/12/2021 12:02 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce = U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. The insulation in any dropped ceiling/soffit Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. Knee walls shall be sealed. with a material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors (including The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to above -garage maintain permanent contact with the underside of and cantilevered subfloor decking, or floor framing cavity insulation floors) shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. v, ,vy w na auai uc in awomanoe Wlln the prDVI$]Qn5 or JU P UU. 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. , FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 c N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling Type and insulation level Insulation Area 6. Conditioned floor area (ft2) 1446 a. Under Attic (Vented) b. Knee Wall R=30.0 1446.00 ft2 (Vented) R=19.0 30.00 ft2 7. Windows" Description Afea c. N/A R= ft2 a. U-Factor: S91, U=1.04 101.25 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.29 a. Sup: Attic, Ret: Attic, AH: Attic 6 175 b. U-Factor: Sgl, U=1.11 40.00 ft2 SHGC: SHGC=0.27 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ft2 SHGC: 14. Heating systems kStu/hr Efficiency Area Weighted Average Overhang Depth: 3.832 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.284 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap: 50 gallons SHGC(AVG): N/A EF: 0.97 9. FloorT es YP Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft= None b. N/A R= ft2 Credits (Performance method) None c. N/A R= ft' I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. - Builder Signature: Date: � C Address of New Home: \ O �L_Q S y/FL Zip: �� �� �V-L *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 . . Wrightsofte Project Summary o . Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Plnre: 772466-67N Fax T72466-6796 Email: QUICKCALCS chi OL.COM Proiect Information For: WYNNE DEVELOPMENT CARLTON III, FT. PIERCE, FL Notes: Desiqn Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 Inside db 70 OF OF Outside db Inside db 90 °F Design TD 28 OF Design TD 75 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19691 Duds Btuh Structure 16785 Bluh 5900 Central vent (0 clim) 0 Btuh Btuh Duds Central vent (0 cim) 8919 0 Btuh Btuh (none) Humidification 0 Btuh (none) Blower 0 Btuh Piping Equipmentload 25591 BStuh Use manufacturers data n Infiltration Rate/swingg multipplier Equipmentsensibleload 0.95 24418 Btuh Method Simplified Construction quality Average Latent Coolie Equipment 9 q pmerrt Load Sizing Fireplaces 0 Structure 2065 Btuh Duds 2429 Btuh Central vent (0 crm) 0 Btuh Heatingg Area (�) 1602 Coolingg 1602 (none) Volume (fP) 14827 14827 Equipment latent load 4493 Btuh Air changes/hour 0.38 Equiv AVF (cfm) 94 0.20 Equipment Total Load (Sen+Lat) 28912 Btuh 49 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536KO30 AHRI ref 7914585 Efficiency Healing input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 34 OF Backup: 8.5 HSPF 34600 Btuh@47°F 27 1160dm 0.045 dm/Btuh 0 in H2O Input=7kW, Output=23009Btuh,100AFUE Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensible cooling 24360 Btuh Latent000ling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfin Air flow, factor 0.045 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.85 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 00 wri tsoft° RigkSuteVDUnversa1201919.021 RSU08101 2021-Jarv12129436 Page 1 ...ris\WngltwflHVACIWYNNE-THE GRAND DARLTQNnp Caic=MJB Frork Ccorfaoes N wrighbow Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Pros: 772A66-6799 Fax 772466-6796 Email: QUICKCALC3@AOL.COM 1 Room name Entire House BEDROOM 2 Eposedmll 1762 ft 41.0 ft 3 Room height 93 ft d 8A ft heaVmol 4 Room dimensons 5 Room area 14.0 x 18.D It 16015 fl, 252.0 fl' Ty Construction U-value Or HTM Area Load Load number (BNh&-,F) (BWhW) or perimeter (1t) (Btuh) orperimeter(t) (BWh) Heat Cool Gross WP/S Heat Cool Gros N/P/S Heat Cool 6 W �G 13AA= tAttan 0.143 ne 4.00 2.55 551 513 2055 1306 72 72 286 183 13A-4= 127C 0.143 m se 3556 4.00 70.43 255 38 128 87 0 1344 2662 0 0 0 0 toclom 1270 se 3556 70.95 20 348 0 711 221 1419 0 0 0 0 0 0 11 11DO 0.390 w 10.92 1131 21 21 229 238 0 0 0 0 0 0 w 13A4ors 0.143 s 4.00 2.55 34 34 136 86 0 0 i--G 13AAa 1A'clom 0.143 w 4.00 2.55 416 390 1562 993 144 144 5T7 361 �G 1270 m 35.56 70.95 6 0 213 426 0 0 0 0 1Aclom 1270 w 35.56 70.95 20 0 711 1419 0 0 0 13A4oc5 0.143 nw 4.00 2.55 352 288 1151 732 112 88 354 0 225 1Aclom to-ctom 1270 nw 3556 4524, 12 0 415 528 12 0 415 526 4A5-2omd 1270 0.770 nw nw 35S6 21.56 4524 36,90 12 0 427 543 12 0 427 543 P 12C-Ow 0.091 - 2.55 128 41 120 720 0 880 306 1505 154 0 0 0 0 0 C F 16A30md 22A-fol 0.032 - 0.90 2.32 1602 1602 1435 3715 252 252 0 0 226 0 585 0989 - 27.69 0.00 1602 176 4878 0 252 41 1135 0 6 c)AEDe=rsion 23 197 Envelope loWgain 15970 3421 2627 12 a) Infiltration b) Roomsentilabon 875 640 180 0 0 0 13 Intemalgaim Omtpar&s@ 230 0 p Appliancs/otherp 0 #30'%530/o 0 Subtotal (lines6b 13) 167115 4"1 2107 Les external load 0 0 0 Lestransrer 0 0 0 Redistibuton 0 0 0 14 Subtotal 16785 4061 2807 15 DuCloads 8979 30°/, 1491 149t Total room load 25591 25704 5278 4298 Air required (Cm) 1160 11. 239 194 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed wrtghLsoT[ AC�A 2021-JarF1272:0476 RiGFtANDCAR-7O .rLp C19.021 RSW8101 Pagel -.rise\WrigYlsoR FNACIWYNNE-THE GRAND GQRLTON.nq CaIc=M18 FrorE�orfarPSN rL wdghtsoiiw RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE UN, Fr. PIERCE, FL 34946 Ptnre: 772-466-6799 Fax 772466-6796 Email: QUICKCAL035AOLOOM 1 2 Room name Fposadmll WIC K45STER BATH 3 Room height 0 ft 8.0 ft heaVcool 17.0 ft 8.0 ft heaVmol 4 5 Roomdimensionsons Room area 7.0 x 9.0 ft ZO x 17.0 ft 630 fF 119.0 ft' Con�ucfon number U-value (Bh1hMr--F) Or HTM (BUhfit') Area or ft Load Area (et Load perimeter () (BWh) or perimefzr (ft) (BWh) Heat Cool Gross NIPS Heat Cool Gros NIPS Heat Cool 6 A-0as 0.143 ne A.00 2.55 0 0 0 cNan 7270 ne 3556 70.43 0 0 0 0 0 0 0 0 0 0 0 A-0ors Q143 u 4.00 2.55 0 0 0 0 0 0 0 clom 1270 se 3556 70.95 0 0 0 0 0 0 0 D0 0.390 10.92 11.31 0 0 0 0 0 0 0A-0ors s 4.00 2.55 0 0 0 0 0 0 0 00.143 A-0ocs 722A-t)1 0.743 sw 4.00 2.55 036 0 0 clom 1270 sx 70.95 0 0 0 0 730 6 $21 33� ctom 1270 sx WM 3400 70.95 0 0 0 0 0 213 426 A-0ors 0.143 nw 4.00 2.55 00 0 0 0 0 -clom 1270 nw WM 4524 0 0 0 0 0 0 0 -ciom 1270 nw 35M 4524 0 0 0 0 0 0 0 5-2omd 0.770 nw 21.56 36.90 00 0 0 0 0 -0sx 0.091 2S5 128 0 0 0 0 0 0 0 A30mtl A-tr)1 0.032 0.90 2.32 63 63 56 146 719 0 779 0 107 0 0 276 0.989 - 27.69 0.00 63 0 0 0 119 17 471 0 6 c)AED ex m.w -13 55 Envelope loss/gain 56 133 1311 7087 12 a) Infiltration 0 0 b) Roomventlabon 265 75 0 0 0 0 13 Internal gains Omtparm@ 230 0 0 0 Appliano:s/other 0 0 0 Subtote (lini 66 133 1577 1162 Les et3emal load 0 0 Less s 0 0 0 D Redistribution 0 0 0 0 14 Subh�41 56 133 0 1577 0 1162 15 Dualoads 30% 53% 17 71 3W, 53% 472 618 Tofal room load Air required (dm) 73 204 20 1780 3 9 93 93 80 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed W� t', � 2021-Jan12129436 i GA EGRA ut CkRLErsa1 CalC.=h RS,Art 01 Do Paget ...nS1WdgF6oft HVAC\WYNNE-THE GRAND G4RLTONrW CsIc=MI6 Frog Coortao:s N +wri-oftow RighW@ Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN.,Fr. PIERCE. FL 34946 Plane: 772-466-6799 Fa 772-4666796 Email: QUICKCALCS@AOL.COM Job: Date: By. 1 1 Room name KTCHEN BATH 2 Bposidwell 0 It 5.0 It 3 Room height 8.0 1t heatl000l 9A ft heaV000l 4 Room dimensors 1.0 x 192.0 ft 9.0 x 5.0 ft 5 Room area ,ern it Ty Construction U-Value Or HTM Area Load Load number (BtuhM'--q (Stutm) or perimeter (ft) (8Wh) oo ocenmeter (ft) (Bhfi) Heat Cool Gros N/P5 Heat Cool Gross NIPS Heat Cool 6 W la44= 0.143 m 4.00 2S5 0 0 0 40 �G IA-clom 1270 ne 3556 70.43 0 0 0 0 40 188 120 13A-4ors 0.143 se 4.00 2.55 0 0 0 0 0 0 tAclom 1270 se 3556 70.85 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W 13A-0as 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 Vy 13A� 0.143 sN 4.00 255 0 0 0 0 0 0 0 1Ac1om 1270 sw 3556 70.95 0 0 0 0 0 II---GG tActom 1270 1270 sw 5,56 35.56 70.95 0.95 0 0 0 0 0 0 0 0 0 13A-flocs nw 0 0 0 0 0 0 0 tActom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 0 1Ac1om 1270 nw 3556 4524 0 0 0 0 0 0 0 4Ai2omd 0.770 nw 2156 36,90 0 0 0 0 0 0 0 P 12C-Ow 0.091 2.55 128 0 0 0 0 0 0 0 0 C 16A30mtl 0.032 - 0.90 2.32 192 192 172 445 45 0 45 0 40 0 0 104 F 22A-¢tl 0.989 - 2749 0.00 192 0 0 0 45 5 138 0 6 0) AED exo M.M -39 -22 Envelope loss/gain 1 172 406 367 202 12 a) Infiltration 0 b) Roomvenfilation 0 92 26 0 0 0 0 13 Intemal gains: O=pants@ 230 0 0 ApplianczJother 0 0 0 0 Subtotal(lines6to13) 172 406 45g 228 I-Mextomal load 0 0 Less transfer 0 0 0 0 Redistribulion 0 0 0 0 14 15 Subtotal Dursloads 172 406 0 459 0 228 30% 53% 52 216 30% 53% 137 121 Total room load Airrequired (dm) 224 622 596 349 10 10 28 27 16 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed AG�L- wrl9h>tso}'e� 2021Jarf1212:04:36 A RigRANDCte& RLMN.rLpsal Calc=l\&RSUOSWI Page3 rigYLsoft FNACIWVNNE-THE GRAND G4RL10N.n.p CaIc=M18 FroNDoorfaces: N wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN, Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax M/ 166-6796 E.i1: 0UICKCALCSAAOLCOM 1 Room name BEDROCM2 ENTRY 2 EVwstlwall 302 ft 6.0 ft 3 Room height 8.0 ft heaV000l 8.0 It heaV000l 4 Room dimensions 1.0 x 1905 ft 6.0 x 70.0 ft 5 Room area 1905 ft' 60.0 IF Ty Consbuc6on U-value Or HTM Area Load Load number I (BWhd2--q (BWhgF) or perimeter (ft) (Btm) oorperimeter (ft) Hea[ Cool Gross N/PS Heat Cool Gross NIP/8 Heat Cool 6 T 13A-4= 0.143 ne 4.00 2.55 120 120 480 305 0 0 _C 1Aciom 1270 ne 35.56 70.43 0 0 0 0 0 0 0 0 0 0 13A-0ors 0.143 se 4.00 2.55 80 60 240 163 48 27 108 69 1AcIcm 1270 se 3556 7095 20 0 711 1419 0 0 0 0 11 11DO 0290 se 10.92 11.31 0 0 0 0 21 21 229 238 W 13A4o s 0.143 s 4.00 2,55 34 34 136, 86 0 0 0 1� 13A4oc; 0.143 sx 4.00 2S5 8 8 32 20 0 0 0 0 �—G 1AcIom 1270 sv 3556 7095 0 0 0 0 0 0 0 1Aclom 1270 sv 35.56 70.95 0 0 0 0 0 0 0 13A-4ors 0.143 nw 4.00 2S5 0 0 0 0 0 0 0 0 1Actom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 1A-clom 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 4A5.2omd 0.770 nw 27.56 36.90 0 0 0 0 0 0 0 P 12C-0sx OA91 2S5 128 0 0 0 0 0 0 0 0 0 C 16A30md OA32 - 090 232 191 191 171 442 60 60 0 54 0 139 F 22A-tpl 0.989 - 27.69 0.00 191 30 835 0 60 6 166 0 6 c)AED emurion 09 �1 Envelopeloss/gain 2606 ]2635 557 404 12 a) Infiltration 472 133 94 26 b) Room ventilation 0 0 0 0 13 Internal gains O=pa=@ 230 0 0 0 Applianoesother 0 0 Subbtal(lines6tn13) 3078 2768 651 430 Lese#emalload 0 0 0 0 Lestransler 0 0 0 0 Redistibution 0 0 0 0 14 Sub�61 3078 2768 651 430 15 Duct loads 30% 53% 922 1471 30% 530% 195 229 Total room load 4000 4239 8 6 Airrequired(dm) 181 191 38 30 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed wrigh sore- 2021Jan1212:0436 A&k RigNSute@Lliv .1201919.021 RSU08101 Page ...rtslWngtftoft WAC\W NE-THEGPANDCARLTON,up Calc=MJ8 FrorRDoorfarnx N wrightsoW Right-M Worksheet jw: Entire House Dare: QUICK CALCS, INC. ay. 317 ST. LUCIE LN., FL PIERCE, FL 34946 Phone: 772-466-6799 Faz 772456-6796 Emil: QUICKC4LCS@40LCOM 1 Room name LAUNDRY GREAMNING wall 6.0 ft 46.0 46.0 ft 3 Room height 8.0 ft heatlmol 12.0 ft heaVowl 4 Room dimensions 7.0 x 610 It 1.0 x 488.0 It 5 Room area 42.0 ff 488A ft' Ty ConsaucAon U-value Or HTM Area (ft=) I Load Area number (BWhX2-19 (Biulaw) or perimeter (ft) (Btuh) or perimeter (ft) (BWh) Heat Cool Gros N/PS Heat Cool Gross NIPS Heat Cool 6 Vmil' 13A4= 0.143 ne 4.00 2.55 0 0 0 0 312 274 1098 698 IA-clom 13A4ocs 1270 0.143 ne se 35.56 4.00 70.43 255 0 0 0 0 0 0 0 38 0 1344 2662 1Ac1om 1270 se 35.56 70.95 0 0 0 0 0 0 0 0 0 0 0 0 0 11 11DO 0.390 sa 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4ots 0.143 s 4.00 255 0 0 0 0 0 0 0 0 y/ 13A4ors 0.143 av a.00 2.55 as 48 lsz 1Y2 0 0 0 0 I�—GC 1Aa1om 1270 w 3556 70.95 0 0 0 0 0 0 0 0 tAclom 1270 w 35.56 70.95 0 0 0 0 0 0 0 0 13A4ocs 0.143 nw 4.00 2.55 0 0 0 0 240 190 798 507 1A-ciom 1270 my 3556 4524 0 0 0 0 0 0 0 0 1Ac1om 1270 nw 3556 4524 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.66 36.90 0 0 0 0 41 0 880 1-905 P 12C-09a 0.091 255 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 ox 2.32 42 42 38 97 486 488 437 1132 F 224-01 0.989 - 27.69 0.00 42 6 166 0 488 46 1274 0 6 c)AED excursion -2 -597 Envelope loss(gain 396 198 5830 sloe 12 a) Infiltration 94 26 t077 304 b) Roomventilation 0 0 0 0 13 Intamalgains: Ocxvpanls@ 230 0 0 0 Applamoes/other 0 1 0 0 Subbtal(lines6to13) 490 224 6907 6212 Lesex$malload 0 0 0 0 Lestransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 490 224 6907 6212 15 Dud loads 30% 53% 147 119 30% 53% 2070 3301 Total room load 636 344 8977 9512 Air required(cfm) 29 16 407 429 Calculations approved byACCAto meet all reouirements of Manual J 8th Ed ...rRN9.021 RS 2021-Jan-121274:36 6Wdgtsoft HVAgWYNNE-THEGRADCARLION.W Calc=MB FrontDoorfacesN Page wrmightsof% RighW@ Worksheet Job. Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE. FL W46 PWw: 772-466-6799 Fax T72466.6796 Email: QUICKCALCS(&AOL.COM 1 Room name BEDROOM3 2 E1posedwall 25.0 it 3 Room height 80 It heat000l 4 Room dimensions 15.0 x 10.0 ft 5 Room area 1500 fF Ty Construction U-value Or HTM Area (fF) Load Area Load number (BWhfiF°F) (Btjw) or perimeter (ft) (BWh) or perimeter Heat Cool Gross NIP/9 Heat Cool Gras NIPS Heat Cool 6 lq/ 13A-0as 0.143 ne a.00 2S5 0 0 0 0 LC 1Ac1om 1270 m 3556 70.43 0 0 0 0 13A-4ors 0.143 se 4.00 255 0 0 0 0 1Aclom 1270 se 3556 70.95 0 0 0 0 11 11D0 0.390 se 10.92 11.31 0 0 0 0 W 13A•os 0.143 s 400 255 0 0 0 0 13A-4or_s 0.143 sm 4.00 2.55 80 60 240 153 Ixelom 1270 six 3556 70.96 0 0 0 0 1Ac1om 1270 sv 35.56 7095 20 0 711 1419 0.143 nw 4.00 2S5 0 0 0 0 TE�13AAocs 1Ac1om 1270 nw 35M 4524 0 0 0 0 1Ac1om 1270 nw 35.56 4524 0 0 0 0 4A5-2omd 0.770 nw 2156 36.90 0 0 0 0 P 12C-Ow 0.091 255 1.2 120 120 306 154 C 16Aa0md 0.032 - 0.90 2.32 150 150 134 348 F 22A-tI 0.989 - 27.69 0.00 150 25 692 0 6 o)AED imurim 296 Ernelope losstgain 2084 2369 12 a) Irdiltation 156 44 b) Roomsentilation 0 0 13 Intamal gains: Occupants@ 230 0 0 Applianossrolher 10 Subtotal(lines W3) 2240 2413 Lesselcemal load 0 0 Lestansfer 0 0 Redistibution 0 0 14 Sub=[ 2240 2413 15 Duct loads 300/, 530/t 671 1282 Total room load 2911 3695 Air required (rim) 1321 167 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed 202Warv1212O4:36 RiGRANDCA LION1p Calc.021 RSU08101 �� ...r�lWdgtvsoft HVAC1WMINE-THE GRAND GARL1ONnp Calc=M18 FronlDoorfaces: N Page