ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
i Low Slope Application
Prescriptive BUR-RAS 150
Asphaltic Shingles
Concrete or Clay Tile
Metal Roofs
Wood Sh ingles and
Shakes
Other
Required Sections of
the Permit Application
Form
A, B, C
A, B, C
A, B, ❑
A,5,D,E
A,B,D
A, B, D
As Applicable
Attachments Required
See List Below
ATTACHMENTS REQUIRED As Aor licahlPl-
1,2,3,4,5,6,7
2,4,5,6,7
1,2,4,5,6,7
1,2,3,4,5,6,7
I A,4,5,6,7
1,2,3,4,5,6,7
1,
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
ST. LUCIE WORKS
Section C (Low Slope Roof)
FIII in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer:
Product Approval
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': _ Zone 1: _ Zone 2: _Zone 3:
Max. Design Pressure, from the specific product approval
system:
Deck:
Gauge Thickness:
Slope:
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s):
Base Sheet Fastener/Bonding Material:
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':_"
oc @ Lap, If Rows_ ® _° co
Zone l:
oc@Lap, # Rows— ®_"oo
Zone 2:—"
oc @ Lap, # Rows— ® _ w
Zone 3:—"
oc @ Lap, # Rows_ ® _-oo
Number of Fasteners Per Insulation Board:
Zone 1':Zone 1:_Zone 2:—Zone 3
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc.,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Detailsthat
Comply with RAS 111 and Chapter 16..
+--
ST. LUC E WORKS
S
Section ❑ (Steep Slope Roof System)
Roof System Manufacturer: `A TAYLOR ROOFING EDGE-LOC 1" STANDING SEAM
Notice of Acceptance Number: NOA:18-1023.17
Minimum Design Wind Pressures, If Applicable (From RA5 127 or Calculations):
Zone 1: -57 Zone 2e:-Lr' 7 Zone 2n -9 1 Zone 2r: -9� Zone 3e: -91 Zone 3r: -128
Deck Type: I PLYWOOD
Type Underlayment: ELF ADHERED UNDERLAYMENT TO POLYGLASS MTS FL#5259.1
Root Slope:
4 12
Insulation:
Fire Barrier:
Ridge VeMi[a on7 Fastener Type & Spacing:[j�F:1E:L:D�4-ERIMETER, BID RING S NK NAILS
Adhesive Type:
Type Cap Sheet:
Mean Roof Height: �5' FT Roof Covering: METAL
Type & Size Drip 2 x 2 912'
Edge:
ST. LUCIE WORKS
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mi. If the Mr values
are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: _x)L_= _)- MU: _=Mn_ Product Approval Mi
(Zone 2e: _x7.�= -Mg:_=Mq_ Product Approval Mr
(Zone 2n: -,_x X_=-Mg_=M�_ Product Approval Mf.
(Zone 2r: _xi = _�- Mg: _=Mm_ Product Approval Mr
(Zone 3e:-x2._=-My;_=M._ Product ApprovalM
(Zone 3r: _X2.__= M9;-=Me_ Product Approval Mr
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (M,) From Table Below -Product Armmval M..
Mr required Moment Resistance*
Mean Roof Height Roof Slope
15'
20'
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39A
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
6:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
25.9
27.1
28.2
30.0
Must be used In conjunction with a list of moment based the systems
For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F'values are greater than or
equal to the F, values, for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Per RAS 12T
(Zone 1: _x L x W:=_J -W;_ cos r= F,i Product Approval F'
(Zone 2e: _x L=xW:=_W Cosr=Fa. Product Approval F'
(Zone 2n: -x L_=xW:=_�-W: cos r_ Fa" Product Approval F'
(Zone 2r. x L x W:= -W: Cos r Fa, Product Approval F'
(Zone 3e: xL =x W:= -W: Cos r=Fri._ Product Approval F'
(Zone 3r: x L= x W:= ) -W: Cos r= Fer Product Approval F'_.
Where to Obtain Information
Description
Symbol
Wheretofind
Design Pressure
Zones 1, 2e, 2n, 2, 3e, 3r
From applicable table In RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
R
Job Site
Aerodynamic Multiplier
ProductApproval
Restoring Moment due to Gravity
Ms
Product Approval
Attachment Resistance
Mr
Product Approval
Required Moment Resistance
Me
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplift Resistance
F,
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L=length W=width
Product Approval
All calculations must be submitted to the building official at the time of permit application.