Loading...
HomeMy WebLinkAboutAPPROVED jb_349407_00___acad_b_01INDEX ABBREVIATIONS VICINITY MAP JURISDICTION NOTES REV BY DATE COMMENTS REV A NAME DATE COMMENTS **** **** **** **** LICENSE GENERAL NOTES • ” • ” • ” • • ELECTRICAL NOTESELECTRICAL NOTES (E) DRIVEWAY Front Of House Pitch4/12MP1Pitch4/12MP3Pitch4/12MP4 Pitch 4/12 MP5Pitch4/12MP6Pitch4/12MP7 Pitch4/12MP8Pitch 4/12 MP10Scale: 1/8" = 1' SITE PLAN 0 1'8'16' LEGEND #SSTAMPFL #ESTAMPFL MP1 18° (4:12) 0 18° (4:12) 0 Solar Roof Two MP3 18° (4:12) 90 18° (4:12) 90 Solar Roof Two MP5 18° (4:12) 270 18° (4:12) 270 Solar Roof Two MP4 18° (4:12) 180 18° (4:12) 180 Solar Roof Two L2 L1 N EGC GND N 240V240V Product 1 EGC DC- DC+ DC- DC+ DC- DC+ C D A DC- DC+ DC- DC+ DC- DC+ DC- DC+ DC- DC+ DC- DC+ GD (5,6) MP 1: 2x30 (3,4) MP 1: 2x30 (1) MP 3: 1x23 (2)MP 5: 1x23 GD L2 L1 N EGC GND N 240V240V Product 2 EGC DC- DC+ DC- DC+ C D B DC- DC+ DC- DC+ DC- DC+ GD (7) MP 4: 1x31 (8,9) MP 4: 2x30 GD A B PV C D 1 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC1 2 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC2 3 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC3 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC4 5 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC5 6 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC6 7 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC7 8 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC8 9 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC9 10 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC10 11 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC11 12 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC12 13 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC13 14 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC14 15 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC15 16 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC16 17 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC17 18 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC18 19 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC19 20 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC20 21 Vmp = VAC Imp= AAC 21 22 Vmp = VAC Imp= AAC 22 N GEC A B GNDGND Y 24 X 23 12V W LICENSEMODULE SPECS 1 PRODUCT SPECSGENERAL NOTESMAIN PANEL SPECS 2 3 AC DCZ POI Y X W 23 24 BS MS 25 25 MS #ESTAMPFL 4 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN LB-130089-10X Per Code: NEC 690.31.G.3 Label Location: (C)(CB)(JB) LB-050081-10X Per Code: NEC 690.13.B Label Location: (DC) (INV) LB-030042-10X Per Code: NEC 690.53 Label Location: (DC) (INV) LB-070004-10X Per Code: 690.41.B Label Location: (DC) (INV) LB-010001-10X Per Code: CEC 690.13.B Label Location: (DC) (CB) LB-050082-10X Per Code: NEC 690.13.B Label Location: (AC) (POI) LB-040007-10X Per Code: NEC 690.54 Label Location: (AC) (POI) LB-070005-10X Per Code: NEC 690.13.B Label Location: (AC)(POI) LB-070039-10X Per Code: NEC 705.12.B.2.3.b Label Location: (POI) LB_040108_10X Per Code: NEC 690.56.C.3 Label Location: (INV) LB-040008-10X Per Code: NEC 690.64.B.4 Label Location: (D) (POI) LB-040009-10X Per Code: NEC 705.12.B.3 Label Location: (POI) LB-060046-10X Per Code: CEC 690.13.B Label Location: (POI) LB-070016-10X Label Location: (DC) (INV) LB-250002-34X Per Code: 690.56(C)(1)(a) Label Location: SolarEdge and,Delta M-Series and,Telsa Inverter (POI): Point of Interconnection (M): Utility Meter (LC): Load Center (INV): Inverter With Integrated DC Disconnect (IC): Interior Run Conduit (DC): DC Disconnect (D): Distribution Panel (CB): Combiner Box (C): Conduit (AC): AC Disconnect Label Set LB-040137-10X Per Code: NEC 408.4 Label Location: (BLC) LB-040144-10X Per Code: NEC 220 Label Location: (BLC) LB-200025-10X Per Code: NEC 312.8.A(3) Label Location: (MSP) LB-030142-10X Per Code: NEC 705.12(B)(3) Label Location: (MSP) LB-040141-10X Per Code: Label Location: (MSP) LB-040139-10X Per Code: Label Location: (MSP) LB-040140-10X Per Code: Label Location: (MSP) LB-040138-10X Per Code: Label Location: (MSP) LB-200011-10X Per Code: NEC 705.12(B)(3) Label Location: (MSP) LB_200127_10X Per Code: NEC 705.12.B.2.3.c Label Location: (MSP) LB-200110-10X Per Code: Per 706.7(D) label to be marked in field Label Location: (MSP) (MSP): Main Service Panel (BLC): Backup Load Center (AC): AC Disconnect Label Set DC- DC+ 1 GD x x x x x DC1 · · · · · DC1 DC- DC+ 1 GD TESLA.COM/ENERGY BACKUP SWITCH ENVIRONMENTAL SPECIFICATIONS Operating Temperature –40°C to 50°C (–40°F to 122°F) Storage Temperature –40°C to 85°C (–40°F to 185°F) Enclosure Rating NEMA 3R Pollution Rating PD3 PERFORMANCE SPECIFICATIONS Model Number 1624171-xx-y Continuous Load Rating 200A, 120/240V Split phase Short Circuit Current Rating 10 kA with any breaker1 22 kA with minimum 22 kA breaker1 Communication CAN Product Compatibility Powerwall 2 with Backup Gateway 2, Powerwall+ Expected Service Life 21 years Warranty 10 years COMPLIANCE INFORMATION Safety Standards USA: UL 414, UL 2735, UL 916 CA Prop 65 Emissions FCC, ICES 2021-09-08 2 Manually overrides the contactor position during a service event. MECHANICAL SPECIFICATIONS Dimensions 176 mm x 205 mm x 74 mm (6.9 in x 8.1 in x 2.9 in) Weight 2.8 lbs Meter and Socket Compatibility ANSI Type 2S, ringless or ring type External Service Interface Contactor manual override2 Reset button Conduit Compatibility 1/2-inch NPT 1 See section 27.12.4 in UL 414. 175.8 204.86 74 The Tesla Backup Switch controls connection to the grid and easily installs behind the utility meter, providing whole home backup with Powerwall. The Backup Switch automatically detects grid outages, providing a seamless transition to backup power. It communicates directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app. 176 mm 205 mm 74 mm TESLA.COM/ENERGY POWERWALL+ Powerwall+ is an integrated solar battery system that stores energy from solar production. Its integrated design and streamlined installation allow for simple connection to any home, and improved surge power capability brings whole home backup in a smaller package. Smart system controls enable owners to customize system behavior to suit their renewable energy needs. KEY FEATURES • Integrated battery, inverter, and system controller for a more compact install • A suite of application modes, including self-powered, time-based control, and backup modes • Wi-Fi, Ethernet, and LTE connectivity with easy over-the-air updates NA 2021-09-08 TESLA.COM/ENERGY POWERWALL+ COMPLIANCE INFORMATION PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1998 (US), IEEE 1547, IEEE 1547.1 Battery Energy Storage System Certifications UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL 1973, UL 9540, IEEE 1547, IEEE 1547.1, UN 38.3 Grid Connection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F)5 Recommended Temperature 0°C to 30°C (32°F to 86°F) Operating Humidity (RH)Up to 100%, condensing Storage Conditions –20°C to 30°C (–4°F to 86°F) Up to 95% RH, non-condensing State of Energy (SoE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type Type 3R Noise Level @ 1 m < 40 db(A) optimal, < 50 db(A) maximum MECHANICAL SPECIFICATIONS Dimensions 1596 x 755 x 160 mm (62.8 x 29.7 x 6.3 in) Total Weight 140 kg (310 lb)4 Battery Assembly 118 kg (261 lb) Solar Assembly 22 kg (49 lb) Mounting options Floor or wall mount 1Values provided for 25°C (77°F). 2AC to battery to AC, at beginning of life. 3Cellular connectivity subject to network service coverage and signal strength. 4The total weight does not include the Powerwall+ bracket, which weighs an additional 9 kg (20 lb). 5Performance may be de-rated at operating temperatures below 10°C (50°F) or greater than 43°C (109°F). NA 2021-09-08 PHOTOVOLTAIC (PV) AND BATTERY ENERGY STORAGE SYSTEM (BESS) SPECIFICATIONS Model Number 1850000-xx-y Nominal Battery Energy 13.5 kWh Nominal Grid Voltage (Input / Output)120/240 VAC Grid Voltage Range 211.2 - 264 VAC Frequency 60 Hz Phase 240 VAC: 2W+N+GND Maximum Continuous Power On-Grid 7.6 kW full sun / 5.8 kW no sun1 Maximum Continuous Power Off-Grid 9.6 kW full sun / 7 kW no sun1 Peak Off-Grid Power (10 s)22 kW full sun / 10 kW no sun1 Maximum Continuous Current On-Grid 32 A output Maximum Continuous Current Off-Grid 40 A output Load Start Capability 118 A LRA PV Maximum Input Voltage 600 VDC PV DC Input Voltage Range 60 - 550 VDC PV DC MPPT Voltage Range 60 - 480 VDC MPPTs 4 Input Connectors per MPPT 1-2-1-2 Maximum Current per MPPT (Imp)13 A Maximum Short Circuit Current per MPPT (Isc) 15 A Allowable DC/AC Ratio 1.7 Overcurrent Protection Device 50 A breaker Maximum Supply Fault Current 10 kA Output Power Factor Rating +/– 0.9 to 1 Round Trip Efficiency 90%2 Solar Generation CEC Efficiency 97.5% at 208 V 98.0% at 240 V Customer Interface Tesla Mobile App Internet Connectivity Wi-Fi, Ethernet, Cellular LTE/4G)3 PV AC Metering Revenue grade (+/-0.5%) Protections Integrated arc fault circuit interrupter (AFCI), PV Rapid Shutdown Warranty 10 years 160 mm 1596 mm 755 mm TESLA.COM/ENERGY SOLAR SHUTDOWN DEVICE The Tesla Solar Shutdown Device is part of the PV system rapid shutdown (RSD) function in accordance with Article 690 of the applicable NEC. When paired with Powerwall+, solar array shutdown is initiated by turning the Powerwall+ Enable switch off, or by pushing the System Shutdown Switch if one is present. 650 mm 150 mm 125 mm 250 mm M4 Screw M8 Bolt Nail / Wood Screw 22 mm NA 2021-09-08 ENVIRONMENTAL SPECIFICATIONS Ambient Temperature -40°C to 50°C (-40°F to 122°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) Enclosure Rating NEMA 4 / IP65 ELECTRICAL SPECIFICATIONS Nominal Input DC Current Rating (IMP)12 A Maximum Input Short Circuit Current (ISC)15 A Maximum System Voltage 600 V DC COMPLIANCE INFORMATION Certifications UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) RSD Initiation Method External System Shutdown Switch Compatible Equipment See Compatibility Table below MECHANICAL SPECIFICATIONS Electrical Connections MC4 Connector Housing Plastic Dimensions 125 mm x 150 mm x 22 mm (5 in x 6 in x 1 in) Weight 350 g (0.77 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw RSD MODULE PERFORMANCE Maximum Number of Devices per String 5 Control Power Line Excitation Passive State Normally open Maximum Power Consumption 7 W Warranty 25 years UL 3741 PV HAZARD CONTROL (AND PVRSA) COMPATIBILITY Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with the Powerwall+ and Solar Shutdown Devices. See the Powerwall+ Installation Manual for detailed instructions and for guidance on installing Powerwall+ and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Tesla Tesla TxxxS (where xxx = 405 to 450 W, increments of 5) 1 Solar Shutdown Device per 3 modules 1 Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules 1Exception: Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to two modules between MCIs. TESLA.COM/ENERGY SYSTEM LAYOUTS Powerwall+ with Backup Switch for Whole Home Backup Powerwall+ with Backup Gateway 2 for Whole Home Backup Powerwall+ with Backup Gateway 2 for Partial Home Backup NA 2021-09-08 SOLAR ROOF (TEAR-OFF AND OVERLAY) DATASHEET 1TESR-DS-0275-21 SOLAR ROOF DATASHEET FOR FULL TEAR-OFF AND OVERLAY INSTALLATIONS SOLAR ROOF (TEAR-OFF AND OVERLAY) DATASHEET 2TESR-DS-0275-21 These electrical characteristics are within ± 5% of the indicated values of Isc, Voc, and Pmax under standard test conditions (irradiance of 1000 W/m2, AM 1.5 spectrum, and a cell temperature of 25 °C or 77 °F). Irradiance (W/m2) Temp. (Celsius) Voc (V) Vmp (V) Isc (A) Imp (A) Pmax (W) 1000 25 14.20 11.34 6.80 6.32 71.67 MECHANICAL SPECIFICATIONS Dimensions: 430 mm x 1140 mm Thickness: Appx. 5 mm module thickness with 35.3 mm maximum height from deck Principal Materials: Glass, Polymers, Fiberglass and Silicon Installed System Weight: Textured Glass: 15 kg/m² or 3.1 psf (Installed weights include all components of system above roof sheathing). CERTIFICATIONS UL 61730 (UL Listed); UL 9703 (UL Listed); UL 1741 (UL Listed) UL 790 Class A (ETL Listed); ASTM D3161 Class F (ETL Listed); TAS100 (ETL Listed) ELECTRICAL SPECIFICATIONS Maximum open circuit voltage rating of connected branch circuits per diode (at STC): 14.2 V Maximum series fuse rating: 10 A Maximum system voltage: 600 V ROOF PITCH RANGE 2:12 - 24:12 Certain features can be installed up to 62:12 14-CELL PV MODULE MODEL #: SR72T1 SOLAR ROOF (TEAR-OFF AND OVERLAY) DATASHEET 3TESR-DS-0275-21 PV MODULE Model #SR60T1 Listed to UL 61730 UL 790 Class A ASTM D3161 Class F TAS100 DIODE HARNESS Model #SRDTH UL 9703 Listed (ZKLA) ”PV Wire” Short and long lead variants interchangeable PASS THROUGH BOX Model #SRPTB-4 UL 1741, File #E318357 6RODU5RRIZLOOEHLQVWDOOHGRYHUEDUHVROLGRUFORVHO\¿WWHGVKHDWKLQJDVIROORZV • DOC PS-1 compliant / exterior grade plywood: minimum 15/32” (11.9 mm) thick or • DOC POS-2 OSB sheathing: minimum 7/16” thick (11.1 mm) or ‡ &ORVHO\¿WWHGVKHDWKLQJERDUGVPLQLPXPRI´ PP WKLFN Solar Roof can also be installed over compatible existing roofs, as follows: • Three-tab composition shingle, single layer • Architectural composition shingle, single layer Solar Roof will not be installed over raised presidential-style composition shingle, roofs with more than one layer of composition shingle, or existing non-composition shingle roof types like tiled roofs. ROOFING MODULES, FULL AND PARTIAL Model #SRNFT1/6, #SRNFT1/3, #SRNFT1/2, #SRNFT2/3, #SRNFT5/6 and #SRNFT1 Listed to UL 61730 Listed to UL 790 Class A ASTM D3161 Class F TAS100 UNDERLAYMENT Model #SR-SAUL-1 or FT Cobalt FR ASTM D1970/ICC AC48 ICC AC188 ASTM E108 Class -A METAL TILES, FULL AND PARTIAL Model #SRMTT1/6, #SRMTT1/3, #SRMTT1/2, #SRMTT2/3, #SRMTT5/6, #SRMTT1 Listed to UL 1897 Listed to UL 790 Class A ASTM D3161 Class F TAS100 SHEATHING SPECIFICATIONS